Loading...
HomeMy WebLinkAboutNC0078158_Compliance Evaluation Inspection_20231031 (2)United States Environmental Protection Agency Form Approved. EPA Washington, D.C. 20460 OMB No. 2040-0057 Water Compliance Inspection Report Approval expires 8-31-98 Section A: National Data System Coding (i.e., PCS) Transaction Code NPDES yr/mo/day Inspection Type Inspector Fac Type 1 IN 2 u 3 I NCO078158 111 121 23/09/15 I17 18 LC] I 19 I s I 20L] 21111I I I I I I I II I I I I I I I I I I I I I I I I I I I I I I I II I I I I I r6 Inspection Work Days Facility Self -Monitoring Evaluation Rating B1 QA ---------------------- Reserved ------------------- 67 I 72 I ni I 73 � I 74 79 I I I I I I I80 70 I I 71 I LL -1 I I LJ Section B: Facility Data Name and Location of Facility Inspected (For Industrial Users discharging to POTW, also include Entry Time/Date Permit Effective Date POTW name and NPDES Dermit Number) 11:30AM 23/09/15 22/11/01 Olde Beau Golf Club WWTP County Downs Ave Exit Time/Date Permit Expiration Date Roaring Gap NC 28668 12:30PM 23/09/15 26/03/31 Name(s) of Onsite Representative(s)/Titles(s)/Phone and Fax Number(s) Other Facility Data William Tyson Young/ORC/336-406-6224/ Name, Address of Responsible Official/Title/Phone and Fax Number Contacted Shannon V Becker,202 Mackenan Dr Cary NC 27511/President/919-653-5570/ No Section C: Areas Evaluated During Inspection (Check only those areas evaluated) Permit 0 Operations & Maintenar 0 Records/Reports Facility Site Review Effluent/Receiving Wate Section D: Summary of Finding/Comments (Attach additional sheets of narrative and checklists as necessary) (See attachment summary) DocuSigned by: (�U�Sbin 10/24/2023 Name BWd' A10e(s) of Inspector(s) Agency/Office/Phone and Fax Numbers Date Gary Hudson DWR/Division of Water Qua Iity/336-776-9694/ Signature of Management Q A Reviewer Agency/Office/Phone and Fax Numbers Date by: 10/31/2023 FLD�ocuSigned _ T. 5,,o r 145B49E225C94EA... EPA Form 3560-3 (Rev 9-94) Previous editions are obsolete. Page# NPDES yr/mo/day Inspection Type NCO078158 I11 12I 23/09/15 117 18 i c i (Cont.) Section D: Summary of Finding/Comments (Attach additional sheets of narrative and checklists as necessary) On September 15, 2023, Division of Water Resources staff Gary Hudson conducted a routine compliance inspection at the Olde Beau WWTP. William Young was present during the inspection. A review of the May 2023, and August 2023 eDMR were compared to laboratory bench sheets. No discrepancies were noted. During the inspection, the following violation and areas of concern were noted: Violation: During the inspection it was noted that the flow meter had not been calibrated since October 28, 2021. Mr. Young has since provided proof that the flow meter was calibrated on October 2, 2023. Areas of Concern: Upon examining the aeration basin the mixed liquor suspended solids (MLSS) appeared to be extremely diluted. Mr. Young said that the settleability test was around 200 SSV, and his MLSS handheld meter was reading 1200 mg/I. The influent flow varies greatly from 1400 gallons per day to 23,000 gallons per day. The following treatment components and documents were inspected: Permit The permit became effective on November 1, 2022, and expires on March 31, 2026. Preliminary Treatment: Preliminary treatment consists of a bar screen. Primary Treatment: Primary treatment consists of one large flow equalization basin. The unit was operating properly during the inspection. Secondary Treatment: Secondary treatment consists of an activated sludge basin (ASB), and a secondary clarifier. Both units were operating properly during the inspection. Final Effluent: A tablet chlorinator with 3 tablet tubes is used for disinfection, and a tablet de -chlorinator with 3 tablet tubes is used for de -chlorination. The effluent flow meter was calibrated on October 2, 2023. Sludge Digestion: Sludge digestion consists of one aerobic digester. Except for the flow meter not being calibrated, the inspection of the facility was satisfactory. If you have any questions regarding the inspection or this report, please contact Gary Hudson or me at (336) 776-9800 or by email at gary.hudson@deq.nc.gov or lon.snider@deq.nc.gov. Page# Permit: NCO078158 Inspection Date: 09/15/2023 Owner -Facility: Olde Beau Golf Club WWTP Inspection Type: Compliance Evaluation Operations & Maintenance Yes No NA NE Is the plant generally clean with acceptable housekeeping? ■ ❑ ❑ ❑ Does the facility analyze process control parameters, for ex: MLSS, MCRT, Settleable ■ ❑ ❑ ❑ Solids, pH, DO, Sludge Judge, and other that are applicable? Comment: The Grade 2 WWTP apeared clean and well maintained. Process control consists of a settleometer test and a hand held MLSS meter. Permit Yes No NA NE (If the present permit expires in 6 months or less). Has the permittee submitted a new ❑ ❑ ■ ❑ application? Is the facility as described in the permit? ■ ❑ ❑ ❑ # Are there any special conditions for the permit? ❑ ■ ❑ ❑ Is access to the plant site restricted to the general public? ■ ❑ ❑ ❑ Is the inspector granted access to all areas for inspection? ■ ❑ ❑ ❑ Comment: The permit became effective on November 1, 2022, and expires on March 31, 2026. Record Keeping Yes No NA NE Are records kept and maintained as required by the permit? ■ ❑ ❑ ❑ Is all required information readily available, complete and current? ■ ❑ ❑ ❑ Are all records maintained for 3 years (lab. reg. required 5 years)? ■ ❑ ❑ ❑ Are analytical results consistent with data reported on DMRs? ■ ❑ ❑ ❑ Is the chain -of -custody complete? ■ ❑ ❑ ❑ Dates, times and location of sampling ■ Name of individual performing the sampling ■ Results of analysis and calibration ■ Dates of analysis ■ Name of person performing analyses ■ Transported COCs ■ Are DMRs complete: do they include all permit parameters? ■ ❑ ❑ ❑ Has the facility submitted its annual compliance report to users and DWQ? ❑ ❑ ■ ❑ (If the facility is = or > 5 MGD permitted flow) Do they operate 24/7 with a certified ❑ ❑ ■ ❑ operator on each shift? Is the ORC visitation log available and current? ■ ❑ ❑ ❑ Is the ORC certified at grade equal to or higher than the facility classification? ■ ❑ ❑ ❑ Is the backup operator certified at one grade less or greater than the facility ■ ❑ ❑ ❑ classification? Page# 3 Permit: NCO078158 Owner -Facility: Olde Beau Golf Club WWTP Inspection Date: 09/15/2023 Inspection Type: Compliance Evaluation Record Keeping Yes No NA NE Is a copy of the current NPDES permit available on site? 0 ❑ ❑ ❑ Facility has copy of previous year's Annual Report on file for review? ❑ ❑ ■ ❑ Comment: A review of the May 2023, and August 2023 eDMR were compared to laboratory bench sheets. No discrepancies were noted. Page#