Water Compliance Inspection Report
Approval expires 8-31-98
Section A: National Data System Coding (i.e., PCS)
Transaction Code NPDES yr/mo/day Inspection Type Inspector Fac Type
1 IN 2 u 3 I NCO061204 111 121 23/09/28 I17 18 L� ] 19 I s I 201
211IIIII 111111III II III III1 I I IIIII IIIIIIIII II r6
Inspection
Work Days Facility Self -Monitoring Evaluation Rating B1 QA ---------------------- Reserved -------------------
67
I 72 I ni I 73 � I 74 79 I I I I I I I80
70 I I 71 I LL -1 I I
LJ
Section B: Facility Data
Name and Location of Facility Inspected (For Industrial Users discharging to POTW, also include
Entry Time/Date
Permit Effective Date
POTW name and NPDES Dermit Number)
12:30PM 23/09/28
21/05/01
Scarlett Acres MHP WWTP
5528 Sherene Ln
Exit Time/Date
Permit Expiration Date
Walkertown NC 27051
01:30PM 23/09/28
24/06/30
Name(s) of Onsite Representative(s)/Titles(s)/Phone and Fax Number(s)
Other Facility Data
Randall Keith Bel 1/0RC/336-373-7514/
Name, Address of Responsible Official/Title/Phone and Fax Number
Contacted
Thomas M Alphin,PO Box 5 Walkertown NC 270510005//336-655-8287/
No
Section C: Areas Evaluated During Inspection (Check only those areas evaluated)
Permit 0 Operations & Maintenar 0 Records/Reports Facility Site Review
Effluent/Receiving Wate
Section D: Summary of Finding/Comments (Attach additional sheets of narrative and checklists as necessary)
(See attachment summary)
DocuSigned by:
Rdsbt& 10/2 5/202 3
Name s)BA'&tV0A1b?e(s) of Inspector(s) Agency/Office/Phone and Fax Numbers Date
Gary Hudson DWR/Division of Water Qua Iity/336-776-9694/
Signature of Management Q A Reviewer Agency/Office/Phone and Fax Numbers Date
DocuSigned by: 10/31/2023
FL' -T. 5,,d r
EA-F-5 h-ARR fW 9-94) Previous editions are obsolete.
Page#
NPDES yr/mo/day Inspection Type
NCO061204 I11 12I 23/09/28 117 18 i c i
(Cont.)
Section D: Summary of Finding/Comments (Attach additional sheets of narrative and checklists as necessary)
On September 21, 2023, Division of Water Resources staff Gary Hudson conducted a routine
compliance inspection at the Scarlet Acres WWTP. Randy Bell was present during the inspection. A
review of the July 2023, and February 2023 eDMR were compared to laboratory bench sheets. No
discrepancies were noted. During the inspection, the following violation and areas of concern were
noted:
Violations: The #2 blower has been inoperable for over six months. Also, two diffuser drop pipes were
inoperable in the A train and one diffuser drop pipe was inoperable in the B train.
Areas of Concern: The flow equalization basin contained excessive amounts of grease and debris
and needs to be cleaned out. Also, there was debris spread across the ground from when the flow
equalization basin had run over in the past.
The following treatment components and documents were inspected:
Permit
The permit became effective on May 31, 2021, and expires on June 30, 2024.
Preliminary Treatment:
Preliminary treatment consists of a bar screen and a splitter box.
Primary Treatment:
Primary treatment consists of one large flow equalization basin. The unit was operating properly
during the inspection.
Secondary Treatment:
Secondary treatment consists of a dual train activated sludge basin (ASB), and a secondary clarifier.
Except for the three inoperable diffusers both units were operating properly during the inspection.
Final Effluent:
A tablet chlorinator with 3 tablet tubes is used for disinfection, and a tablet de -chlorinator with 3 tablet
tubes is used for de -chlorination. The effluent flow meter was calibrated on July 29, 2023.
Sludge Digestion:
Sludge digestion consists of one aerobic digester.
Page#
Permit: NCO061204
Inspection Date: 09/28/2023
Owner -Facility: Scarlett Acres MHP WWTP
Inspection Type: Compliance Evaluation
Operations & Maintenance Yes No NA NE
Is the plant generally clean with acceptable housekeeping? ❑ ■ ❑ ❑
Does the facility analyze process control parameters, for ex: MLSS, MCRT, Settleable ■ ❑ ❑ ❑
Solids, pH, DO, Sludge Judge, and other that are applicable?
Comment: Violation: The #2 blower has been inoperable for over six months. Also, two diffuser
drop pipes were inoperable in the A train and one diffuser drop pipe was inoperable in
the B train.
Areas of Concern: The flow equalization basin contained excessive amounts of grease
and debris and needs to be cleaned out. Also, there was debris spread across the
ground from when the flow equalization basin had run over in the past.
Permit
Yes
No
NA
NE
(If the present permit expires in 6 months or less). Has the permittee submitted a new
❑
❑
■
❑
application?
Is the facility as described in the permit?
■
❑
❑
❑
# Are there any special conditions for the permit?
❑
■
❑
❑
Is access to the plant site restricted to the general public?
■
❑
❑
❑
Is the inspector granted access to all areas for inspection?
■
❑
❑
❑
Comment: The permit became effective on May 31, 2021, and expires on June 30, 2024.
Record Keeping
Yes
No
NA
NE
Are records kept and maintained as required by the permit?
■
❑
❑
❑
Is all required information readily available, complete and current?
■
❑
❑
❑
Are all records maintained for 3 years (lab. reg. required 5 years)?
■
❑
❑
❑
Are analytical results consistent with data reported on DMRs?
■
❑
❑
❑
Is the chain -of -custody complete?
■
❑
❑
❑
Dates, times and location of sampling
■
Name of individual performing the sampling
■
Results of analysis and calibration
■
Dates of analysis
■
Name of person performing analyses
■
Transported COCs
■
Are DMRs complete: do they include all permit parameters?
■
❑
❑
❑
Has the facility submitted its annual compliance report to users and DWQ?
❑
❑
■
❑
(If the facility is = or > 5 MGD permitted flow) Do they operate 24/7 with a certified
❑
❑
■
❑
operator on each shift?
Is the ORC visitation log available and current?
■
❑
❑
❑
Page# 3
Permit: NCO061204
Inspection Date: 09/28/2023
Record Keeping
Owner -Facility: Scarlett Acres MHP WWTP
Inspection Type: Compliance Evaluation
Is the CIRC certified at grade equal to or higher than the facility classification?
Is the backup operator certified at one grade less or greater than the facility
classification?
Is a copy of the current NPDES permit available on site?
Facility has copy of previous year's Annual Report on file for review?
Yes No NA NE
■ ❑ ❑ ❑
■ ❑ ❑ ❑
■ ❑ ❑ ❑
❑ ❑ ■ ❑
Comment: . A review of the July 2023, and February 2023 eDMR were compared to laboratory
bench sheets. No discrepancies were noted.
Page# 4