HomeMy WebLinkAboutNC0061204_Compliance Evaluation Inspection_20231031 (2)United States Environmental Protection Agency Form Approved. EPA Washington, D.C. 20460 OMB No. 2040-0057 Water Compliance Inspection Report Approval expires 8-31-98 Section A: National Data System Coding (i.e., PCS) Transaction Code NPDES yr/mo/day Inspection Type Inspector Fac Type 1 IN 2 u 3 I NCO061204 111 121 23/09/28 I17 18 L� ] 19 I s I 201 211IIIII 111111III II III III1 I I IIIII IIIIIIIII II r6 Inspection Work Days Facility Self -Monitoring Evaluation Rating B1 QA ---------------------- Reserved ------------------- 67 I 72 I ni I 73 � I 74 79 I I I I I I I80 70 I I 71 I LL -1 I I LJ Section B: Facility Data Name and Location of Facility Inspected (For Industrial Users discharging to POTW, also include Entry Time/Date Permit Effective Date POTW name and NPDES Dermit Number) 12:30PM 23/09/28 21/05/01 Scarlett Acres MHP WWTP 5528 Sherene Ln Exit Time/Date Permit Expiration Date Walkertown NC 27051 01:30PM 23/09/28 24/06/30 Name(s) of Onsite Representative(s)/Titles(s)/Phone and Fax Number(s) Other Facility Data Randall Keith Bel 1/0RC/336-373-7514/ Name, Address of Responsible Official/Title/Phone and Fax Number Contacted Thomas M Alphin,PO Box 5 Walkertown NC 270510005//336-655-8287/ No Section C: Areas Evaluated During Inspection (Check only those areas evaluated) Permit 0 Operations & Maintenar 0 Records/Reports Facility Site Review Effluent/Receiving Wate Section D: Summary of Finding/Comments (Attach additional sheets of narrative and checklists as necessary) (See attachment summary) DocuSigned by: Rdsbt& 10/2 5/202 3 Name s)BA'&tV0A1b?e(s) of Inspector(s) Agency/Office/Phone and Fax Numbers Date Gary Hudson DWR/Division of Water Qua Iity/336-776-9694/ Signature of Management Q A Reviewer Agency/Office/Phone and Fax Numbers Date DocuSigned by: 10/31/2023 FL' -T. 5,,d r EA-F-5 h-ARR fW 9-94) Previous editions are obsolete. Page# NPDES yr/mo/day Inspection Type NCO061204 I11 12I 23/09/28 117 18 i c i (Cont.) Section D: Summary of Finding/Comments (Attach additional sheets of narrative and checklists as necessary) On September 21, 2023, Division of Water Resources staff Gary Hudson conducted a routine compliance inspection at the Scarlet Acres WWTP. Randy Bell was present during the inspection. A review of the July 2023, and February 2023 eDMR were compared to laboratory bench sheets. No discrepancies were noted. During the inspection, the following violation and areas of concern were noted: Violations: The #2 blower has been inoperable for over six months. Also, two diffuser drop pipes were inoperable in the A train and one diffuser drop pipe was inoperable in the B train. Areas of Concern: The flow equalization basin contained excessive amounts of grease and debris and needs to be cleaned out. Also, there was debris spread across the ground from when the flow equalization basin had run over in the past. The following treatment components and documents were inspected: Permit The permit became effective on May 31, 2021, and expires on June 30, 2024. Preliminary Treatment: Preliminary treatment consists of a bar screen and a splitter box. Primary Treatment: Primary treatment consists of one large flow equalization basin. The unit was operating properly during the inspection. Secondary Treatment: Secondary treatment consists of a dual train activated sludge basin (ASB), and a secondary clarifier. Except for the three inoperable diffusers both units were operating properly during the inspection. Final Effluent: A tablet chlorinator with 3 tablet tubes is used for disinfection, and a tablet de -chlorinator with 3 tablet tubes is used for de -chlorination. The effluent flow meter was calibrated on July 29, 2023. Sludge Digestion: Sludge digestion consists of one aerobic digester. Page# Permit: NCO061204 Inspection Date: 09/28/2023 Owner -Facility: Scarlett Acres MHP WWTP Inspection Type: Compliance Evaluation Operations & Maintenance Yes No NA NE Is the plant generally clean with acceptable housekeeping? ❑ ■ ❑ ❑ Does the facility analyze process control parameters, for ex: MLSS, MCRT, Settleable ■ ❑ ❑ ❑ Solids, pH, DO, Sludge Judge, and other that are applicable? Comment: Violation: The #2 blower has been inoperable for over six months. Also, two diffuser drop pipes were inoperable in the A train and one diffuser drop pipe was inoperable in the B train. Areas of Concern: The flow equalization basin contained excessive amounts of grease and debris and needs to be cleaned out. Also, there was debris spread across the ground from when the flow equalization basin had run over in the past. Permit Yes No NA NE (If the present permit expires in 6 months or less). Has the permittee submitted a new ❑ ❑ ■ ❑ application? Is the facility as described in the permit? ■ ❑ ❑ ❑ # Are there any special conditions for the permit? ❑ ■ ❑ ❑ Is access to the plant site restricted to the general public? ■ ❑ ❑ ❑ Is the inspector granted access to all areas for inspection? ■ ❑ ❑ ❑ Comment: The permit became effective on May 31, 2021, and expires on June 30, 2024. Record Keeping Yes No NA NE Are records kept and maintained as required by the permit? ■ ❑ ❑ ❑ Is all required information readily available, complete and current? ■ ❑ ❑ ❑ Are all records maintained for 3 years (lab. reg. required 5 years)? ■ ❑ ❑ ❑ Are analytical results consistent with data reported on DMRs? ■ ❑ ❑ ❑ Is the chain -of -custody complete? ■ ❑ ❑ ❑ Dates, times and location of sampling ■ Name of individual performing the sampling ■ Results of analysis and calibration ■ Dates of analysis ■ Name of person performing analyses ■ Transported COCs ■ Are DMRs complete: do they include all permit parameters? ■ ❑ ❑ ❑ Has the facility submitted its annual compliance report to users and DWQ? ❑ ❑ ■ ❑ (If the facility is = or > 5 MGD permitted flow) Do they operate 24/7 with a certified ❑ ❑ ■ ❑ operator on each shift? Is the ORC visitation log available and current? ■ ❑ ❑ ❑ Page# 3 Permit: NCO061204 Inspection Date: 09/28/2023 Record Keeping Owner -Facility: Scarlett Acres MHP WWTP Inspection Type: Compliance Evaluation Is the CIRC certified at grade equal to or higher than the facility classification? Is the backup operator certified at one grade less or greater than the facility classification? Is a copy of the current NPDES permit available on site? Facility has copy of previous year's Annual Report on file for review? Yes No NA NE ■ ❑ ❑ ❑ ■ ❑ ❑ ❑ ■ ❑ ❑ ❑ ❑ ❑ ■ ❑ Comment: . A review of the July 2023, and February 2023 eDMR were compared to laboratory bench sheets. No discrepancies were noted. Page# 4