Loading...
HomeMy WebLinkAbout20221496 Ver 3_More Info Requested_20231101Doc 1" Envelope ID: CDC4EOCF-A52D-46ED-8154-EE7FD3FA36F? ROY COOPER Governor ELIZABETH S. BISER Secretary RICHARD E. ROGERS, JR. Director NORTH CAROLINA Environmental Quality November 1, 2023 DWR # 20221496 v3 Chatham County BIN-AGP, LLC Attn: Mr. Jon Morris 500 Morehead St, Suite 200 Charlotte NC 28202 Delivered via email to: jon@beacondevelopment.com Subject: REQUEST FOR ADDITIONAL INFORMATION Apex Gateway Industrial Center Dear Mr. Morris: On September 22, 2023, the Division of Water Resources (Division) received your application requesting a 401 Individual Water Quality Certification from the Division for the subject project. The Division has determined that your application is incomplete and cannot be processed. Upon review of the below requested information, subsequent requests for additional information may be necessary. The application is on -hold until all of the following information is received: 1. If the U.S. Army Corps of Engineers requests a response to any comments received as a result of the Public Notice, please provide the Division with a copy of your response to the USACE. [15A NCAC 02H .0502(c)] 2. The Division is unable to complete a review of the application until features identified as non - jurisdictional / isolated has been confirmed by the USACE. Please submit a copy of the Approved Jurisdictional Determination when available. 3. Please provide a DWR stream identification form for all intermittent channels. If any intermittent channel becomes perennial at any point within the project limits, please clearly indicate that location on plan sheets and provide a separate DWR stream identification form for the perennial section. Upon receipt of this information the Division may choose to conduct a site visit to confirm the proposed stream classifications. 4. Please be aware that isolated streams will require authorization under 15A NCAC 02H .1300. 5. It appears that further avoidance and minimization is feasible for the proposed project. Specifically, the application indicates that the buildings proposed are speculative in nature. The Division acknowledges the discussion provided in the application regarding the need for speculative development. The application states that industrial buildings are proposed which include sizes ranging from 27,000 to 375,000 square feet. While the Division commends the � North Carolina Department of Environmental Quality I Division of Water Resources 512 North Salisbury Street 1 1617 Mail Service Center I Raleigh, North Carolina 27699-1617 NORTH CAROLINA oaa..m.mof�runn,aM,lOual\ /� 919.707.9000 DocuSign Envelope ID: CDC4EOCF-A52D-46ED-8154-EE7FD3FA36F2 Apex Gateway DWR# 20221496 v2 Page 2 of 3 applicant for the efforts made so far to avoid and minimize to the maximum extent practical, the building size range provided would indicate that various building sizes and configurations are feasible and therefore that additional avoidance and minimization could still be possible. Please provide additional information to support the current proposal of building sizes and configurations. If the information provided to support the proposed configuration is dependent on financial aspects of the project, please provide more specific information than the current statement that the proposed facilities are "extremely valuable and having more of each is beneficial". 6. A significant portion of proposed impacts include impacts to streams and wetlands for stormwater control measures (SCMs). While the Division understands the need for adequate stormwater management, and that typically SCMs are installed at the low point in the landscape, it appears that further avoidance and minimization could be accomplished by utilizing various stormwater control measures that take up less area, dividing stormwater management into smaller drainage areas with smaller SCMs that could be located in smaller upland areas, or a combination of both. Please provide additional information to support the current proposal of SCMs locations and sizes. 7. Pursuant to 15A NCAC 02H.0506(b) "a 401 Water Quality Certification may only be issued upon determining that the proposed activity will comply with state water quality standards which includes designated uses, numeric criteria, narrative criteria and the state's antidegradation policy, as defined in rules of 15A NCAC 02B .0200... In assessing whether the proposed activity will comply with water quality standards, the Division shall evaluate if the proposed activity: (2) would cause or contribute to a violation of water quality standards; (3) would result in secondary or cumulative impacts that cause or contribute to, or will cause or contribute to, a violation of water quality standards;" Based on the current proposed plan the Division believes there is potential for indirect impacts to: a. the upper portion of CH100, CH400 and the upper portion of WL1400 as all surface flow to this channel appears to be routed to two SCMs which would discharge within the middle portion of WL1400 and into WL1300. b. CH800 and WL2900 as all surface flow to this channel appears to be routed to two SCMs which would discharge within the middle portion of CH800. Please either, include indirect impacts to these features within the impact table and provide mitigation as appropriate, provide hydrologic calculations to document that surface flow will continue to support the existing function of the unimpacted features, or provide a monitoring plan that will document existing conditions and post construction conditions of these features. 8. The plan sheets provided appear to show grading limits to the very edge of some jurisdictional features and in some locations grading limits appear to be left off the details in areas adjacent to jurisdictional features. For example, please see Impact Detail 2 & 3. The Division is unable to conduct an adequate review of the project based on the information provided. Please provide clear engineering drawings that show ALL limits of disturbance within the site, particularly immediately adjacent to any jurisdictional features. 9. The application proposes on -site preservation to satisfy a portion of the mitigation requirements. The Division has significant reservations about the proposal to provide preservation of onsite features when these features will be surrounded by future high - density development. The Division requires that a site visit be conducted with Division staff D E Q�� North Carolina Department of Environmental Quality I Division of Water Resources NORTH CAROL NA ��` !!!/// 512 North Salisbury Street 1 1617 Mail Service Center I Raleigh, North Carolina 27699-1617 oeprUm tofEmlmMIB�IOwI 919.707.9000 DocuSign Envelope ID: CDC4EOCF-A52D-46ED-8154-EE7FD3FA36F2 Apex Gateway DWR# 20221496 v2 Page 3 of 3 and the Interagency Review Team to evaluate the proposed preservation site in order to ensure consistency between all mitigation proposals and mitigation providers. Pursuant to Title 15A NCAC 02H .0502(e), the applicant shall furnish all of the above requested information for the proper consideration of the application. Please respond in writing within 30 calendar days of receipt of this letter by sending one (1) copy of all of the above requested information to the 401 & Buffer Permitting Branch, 1617 Mail Service Center, Raleigh, NC 27699-1617 OR by submitting all of the above requested information through this link: https://edocs.deg.nc.gov/Forms/Supplemental-Information-Form (note the DWR# requested on the link is referenced above). If all of the requested information is not received within 30 calendar days of receipt of this letter, the Division will be unable to approve the application and it will be denied as incomplete. The denial of this project will necessitate reapplication to the Division for approval, including a complete application package and the appropriate fee. Please be aware that you have no authorization under the Section 401 of the Clean Water Act for this activity and any work done within waters of the state may be a violation of North Carolina General Statutes and Administrative Code. Please contact Sue Homewood at 336-813-1863 or sue.homewood@ncdenr.gov if you have any questions or concerns. Sincerely, Stephanie Goss, Supervisor 401 & Buffer Permitting Branch Electronic cc: Jennifer Robertson, ATLAS Environmental Rachel Capito, USACE Raleigh Regulatory Field Office DWR 401 & Buffer Permitting Branch Electronic file Filename: 20221496v3_Apex Gateway_Chatham_addinfo.docx D � � � North Carolina Department of Environmental Quality I Division of Water Resources 512 North Salisbury Street 1 1617 Mail Service Center I Raleigh, North Carolina 27699-1617 NORTH CAROLINA 04patneMbfE I,—U10-Ift /� 919.707.9000