Loading...
HomeMy WebLinkAboutWQ0004972_Monitoring - 09-2023_20231030Monitoring Report Submittal ................................................... Permit Number#* WQ0004972 Name of Facility:* Forest Lake RV WWTP Month: * September Year: * 2023 Report Information Type* Upload Document* NDMR, NDAR-1, NDAR-2, NDMLR 2023_September_Monthly Report_WQ0004972 1.58MB complete.pdf PDF Only Please upload one PDF containing all applicable monitoring reports (i.e., NDMR, NDAR-1, NDAR-2, NDMLR, GW-59). Confirmation Email Address: * agrenier@greenerehssolutions.com Name of Submitter: * Amanda Grenier Signature: 0501W- KIt<ll (I' W;r 'f Date of submittal: 10/30/2023 This will be filled in automatically Initial Review Reviewer: Wanda.Gerald Is the project number correct?* W00004972 Is the monitoring report accepted?* Yes NO Regional Office* Winston-Salem Reviewer: _anonymous Review Date: 11/1/2023 DocuSign Envelope ID: 1AC346DE-6112-480C-AF72-160AB0096CED niON-DISCHARGE APPLICATION REPORT (NDAR-1) Page of Permit No.: Q1114972 Facility Name: Forest Lake D.vie Month: September1 irrigation • occur this facility'? Coverat .. . .. . .. . .. ■ NO Hourly Rate (in): Hourly Rate I .: Annual Rate (in): Annual Rate (in): Field Irrigated? Field Irrigated? oil M111,M111. Monthly ... . 1 .•���j�����j����j���j�% 12 Month Floating Total (irs ���®�, DocuSign Envelope ID: 1AC346DE-6112-480C-AF72-160AB0096CED Did the application rates exceed the limits in Attachment B of your permit? O Compliant ❑ Non -Compliant Were adequate measures taken to prevent effluent ponding in or runoff from the sites? O Compliant ❑ Non -Compliant Was a suitable vegetative cover maintained on all sites as specified in your permit? O Compliant ❑ Non -Compliant Were all setbacks listed in your permit maintained for every application to each permitted site? O Compliant ❑ Non -Compliant Were all freeboards maintained in accordance with the specified freeboard heights in your permit? O Compliant ❑ Non -Compliant If the facility is non -compliant, please explain in the space below the reason(s) the facility was not in compliance. Provide in your explanation the date(s) of the non-compliance and describe the corrective action(s) taken. Attach additional sheets if necessary. Operator in Responsible Charge (ORC) Certification Permittee Certification ORC: Sam Perry Permittee: MHC TT, LP Certification No.: 1014038 Signing Official: George Gudgeon Grade: SI Phone Number: 919-548-2381 Signing Officials Title: Sr. Vice President Has the ORC changed since the previous NDAR-1? ❑ Yes ❑ No Phone Number: 312-279-1400 Permit Exp.: 10/31/27 10 29 2023 al2l"d rem DocuSigned by: 10/29/2023 Samuel Perry (Oct 29, 2023 1 27 EDT) Boseanosi=zcaaco Signature Date Signature Date By this signature, I certify that this report is accurrate and complete to the best of my knowledge. I certify, under penalty of law, that this document and all attachments were prepared under my direction or supervision in accordance with a system designed to assure that all qualified personnel properly gathered and evaluated the information submitted. Based on my inquiry of the person or persons who manage the system, or those persons directly responsible for gathering the information, the information submitted is, to the best of my knowledge and belief, true, accurate, and complete. I am aware that there are significant penalties for submitting false information, including the possibility of fines and imprisonment for knowing violations. Mail Original and Two Copies to: Division of Water Resources Information Processing Unit 1617 Mail Service Center Raleigh, North Carolina 27699-1617 DocuSign Envelope ID: 1AC346DE-6112-480C-AF72-160AB0096CED Permit No.: WQ0004972 Facility Name: Forest Lake Preserve ELS County: Davie Month: September Year: 2023 PPI: 001 Flow Measuring Point: El Influent 0 Effluent ❑ No flow generated parameter Monitoring Point: ❑ Influent ❑Effluent ❑Groundwater Lowering El Surface Water Parameter Code 0 50050 00400 50060 1 70300 00530 00310 31616 00600 00610 00625 00630 00620 00615 00665 00940 U O C O O O Q O". 'a N '0 O. Um O N U O LL � a L C Z H Z Z R Z .0 Z~sZ Vl 7 L (n a UO 24-hr hrs GPD su mg/L mg/L mg/L mg/L #/100 mL mg/L mg/L mg/L mg/L mg/L mg/L mg/L mg/L 1 08:00 5 36,538 5.9 2.7 2 27,617 3 35,177 4 HOLIDAY HOLIDAY 34,194 5 08:00 5 33,691 6.4 0.2 6 08:00 5 24,552 6.6 4.2 246 16 3.4 440 8.9 3.7 6.8 2.1 2.1 <0.04 7.9 7 08:00 5 36,548 6.5 4.6 8 08:00 5 31,074 6.7 0.6 9 29,057 10 37,598 11 08:00 5 77,127 6.3 0.1 12 08:00 5 39,089 6.1 4.5 13 08:00 5 64,970 6.2 4.3 14 08:00 5 28,412 6.2 4.5 15 08:00 5 24,145 6.1 4.1 16 22,753 17 23,329 18 08:00 5 39,913 7 19 08:00 5 26,707 6.3 4.3 20 08:00 5 27,648 6.2 4.4 21 08:00 5 31,040 6 4.5 22 08:00 5 29,354 6.5 4.4 23 29,214 24 27,276 25 08:00 5 35,478 6.2 0.7 26 08:00 5 27,055 6.8 3.9 27 08:00 5 18,728 6.3 4.1 28 08:00 5 24,245 6 3.4 29 08:00 5 31,497 6.1 4.6 30 30,325 31 Average: 32,812 3.37 246.00 16.00 3.40 440.00 8.90 3.70 6.80 2.10 2.10 0.00 7.90 Daily Maximum: 77,127 7.00 4.60 246.00 16.00 3.40 440.00 8.90 3.70 6.80 2.10 2.10 0.04 7.90 Daily Minimum: 18,728 5.90 0.10 246.00 16.00 3.40 440.00 8.90 3.70 6.80 2.10 2.10 0.04 7.90 Sampling Type: Monthly Avg. Limit: Daily Limit: LSample Frequency: Continuous 5x/Week 5X/Week Monthly Monthly Monthly Monthly Monthly Monthly Monthly Monthly Monthly Monthly Monthly 3X/year DocuSign Envelope ID: 1AC346DE-6112-480C-AF72-160AB0096CED Sampling Person(s) Certified Laboratories Name: Sam Perry Name: Name: Greener EHS Solutions, LLC Name: Pace Analytical Does all monitoring data and sampling frequencies meet the requirements in Attachment A of your permit? ❑ Compliant O Non -Compliant If the facility is non -compliant, please explain in the space below the reason(s) the facility was not in compliance. Provide in your explanation the date(s) of the non-compliance and describe the corrective action(s) taken. Attach additional sheets if necessary. The Monthly average flow exceeded the permitted flow of 24,400 gpd. The permitted application rate was not exceeded. The flow meter was calibrated on June 27, 2023 and the meter was reading significantly low before the calibration. This was noted on the June 2023 NDMR. The plant is in the process of an upgrade to increase the capacity as well as investigating extraneous flow for 1/1 and leaking fixtures. Lab Qualifiers, September 6, 2023 - BOD, B2 - Oxygen usage is less than 2.0 for all dilutions set. The reported value is an estimated less than value and is calculated for the dilution using the most amount of sample. Phosphorus and TKN, M1 - Matrix spike recovery exceeded QC limits. Batch accepted based on laboratory control sample (LCS) recovery and R1 - RPD value was outside control limits. Operator in Responsible Charge (ORC) Certification Permittee Certification ORC: Sam Perry Permittee: MHC TT, LP Certification No.: 1014038 Signing Official: George Gudgeon Grade: SI Phone Number: 919-548-2381 Signing Officials Title: Sr. Vice President Has the ORC changed since the previous NDMR? ❑ Yes ❑ No Phone Number: 312-279-1400 Permit Expiration: 10/31/2027 sawar Tem 10/29/2023 uSigned by: Lcr�t,jvu10/29/2023 Samuel Perry (Oct 29, 2023 1 27 EDT)v Signature Date Signature Date By this signature, I certify that this report is accurrate and complete to the best of my knowledge. I certify, under penalty of law, that this document and all attachments were prepared under my direction or supervision in accordance with a system designed to assure that all qualified personnel properly gathered and evaluated the information submitted. Based on my inquiry of the person or persons who manage the system, or those persons directly responsible for gathering the information, the information submitted is, to the best of my knowledge and belief, true, accurate, and complete. I am aware that there are significant penalties for submitting false information, including the possibility of fines and imprisonment for knowing violations. Mail Original and Two Copies to: Division of Water Resources Information Processing Unit 1617 Mail Service Center Raleigh, North Carolina 27699-1617 DocuSign Envelope ID: 1AC346DE-6112-480C-AF72-160AB0096CED aceo Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 September 19, 2023 Amanda D. Grenier Greener EHS Solutions 21 Selby Ct. Holly Springs, NC 27540 RE: Project: FOREST LAKE -MONTHLY Pace Project No.: 92686316 Dear Amanda Grenier: Enclosed are the analytical results for sample(s) received by the laboratory on September 06, 2023. The results relate only to the samples included in this report. Results reported herein conform to the applicable TNI/NELAC Standards and the laboratory's Quality Manual, where applicable, unless otherwise noted in the body of the report. The test results provided in this final report were generated by each of the following laboratories within the Pace Network: • Pace Analytical Services - Asheville • Pace Analytical Services - Charlotte If you have any questions concerning this report, please feel free to contact me. Sincerely, Matthew Brainard matthew.brainard@pacelabs.com (704)875-9092 Project Manager Enclosures REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, LLC. Page 1 of 17 DocuSign Envelope ID: 1AC346DE-6112-480C-AF72-160AB0096CED aceo Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 Project: FOREST LAKE -MONTHLY Pace Project No.: 92686316 Pace Analytical Services Charlotte South Carolina Laboratory ID: 99006 9800 Kincey Ave. Ste 100, Huntersville, NC 28078 North Carolina Drinking Water Certification #: 37706 North Carolina Field Services Certification #: 5342 North Carolina Wastewater Certification #: 12 South Carolina Laboratory ID: 99006 Pace Analytical Services Asheville 2225 Riverside Drive, Asheville, NC 28804 Florida/NELAP Certification #: E87648 North Carolina Drinking Water Certification #: 37712 North Carolina Wastewater Certification #: 40 CERTIFICATIONS South Carolina Certification #: 99006001 South Carolina Drinking Water Cert. #: 99006003 Florida/NELAP Certification #: E87627 Kentucky UST Certification #: 84 Louisiana DoH Drinking Water #: LA029 VirginiaNELAP Certification #: 460221 South Carolina Laboratory ID: 99030 South Carolina Certification #: 99030001 VirginiaNELAP Certification #: 460222 REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, LLC. Page 2 of 17 DocuSign Envelope ID: 1AC346DE-6112-480C-AF72-160AB0096CED Pace Analytical Services, LLC �aceo 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 SAMPLE ANALYTE COUNT Project: FOREST LAKE -MONTHLY Pace Project No.: 92686316 Analytes Lab ID Sample ID Method Analysts Reported Laboratory 92686316001 EFFLUENT GRAB SM 9222D-2015 KDF 1 PASI-C SM 2540C-2015 JMH1 1 PASI-A SM 2540D-2015 JMH1 1 PASI-A SM 521OB-2016 MDM 1 PASI-A TKN+NO3+NO2 Calculation MDW 1 PASI-A EPA 350.1 Rev 2.0 1993 ARJ 1 PASI-A EPA 351.2 Rev 2.0 1993 MDW 1 PASI-A EPA 353.2 Rev 2.0 1993 NCF 1 PASI-A EPA 365.1 Rev 2.0 1993 Zip 1 PASI-A PASI-A = Pace Analytical Services - Asheville PASI-C = Pace Analytical Services - Charlotte REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, LLC. Page 3 of 17 DocuSign Envelope ID: 1AC346DE-6112-480C-AF72-160AB0096CED aceo Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 ANALYTICAL RESULTS Project: FOREST LAKE -MONTHLY Pace Project No.: 92686316 Sample: EFFLUENT GRAB Lab ID: 92686316001 Collected: 09/06/23 11:00 Received: 09/06/23 14:48 Matrix: Water Parameters Results Units Report Limit DF Prepared Analyzed CAS No. Qual MBIO 9222D Fecal Coliform CHT Analytical Method: SM 9222D-2015 Preparation Method: SM 9222D-2015 Pace Analytical Services - Charlotte Fecal Coliforms 440 CFU/100 mL 1.0 1 09/06/23 15:35 09/07/23 14:13 2540C Total Dissolved Solids Analytical Method: SM 2540C-2015 Pace Analytical Services -Asheville Total Dissolved Solids 246 mg/L 25.0 1 09/07/23 12:49 2540D Total Suspended Solids Analytical Method: SM 2540D-2015 Pace Analytical Services -Asheville Total Suspended Solids 16.0 mg/L 5.9 1 09/07/23 12:39 5210B BOD, 5 day Analytical Method: SM 521OB-2016 Pace Analytical Services -Asheville BOD, 5 day 3.4 mg/L 2.0 1 09/08/23 03:30 09/13/23 00:53 Total Nitrogen Calculation Analytical Method: TKN+NO3+NO2 Calculation Pace Analytical Services -Asheville Total Nitrogen 8.9 mg/L 0.040 1 09/19/23 16:04 350.1 Ammonia Analytical Method: EPA 350.1 Rev 2.0 1993 Pace Analytical Services -Asheville Nitrogen, Ammonia 3.7 mg/L 0.10 1 09/16/23 12:08 7664-41-7 351.2 Total Kjeldahl Nitrogen Analytical Method: EPA 351.2 Rev 2.0 1993 Preparation Method: EPA 351.2 Rev 2.0 1993 Pace Analytical Services -Asheville Nitrogen, Kjeldahl, Total 6.8 mg/L 0.50 1 09/18/23 16:09 09/19/23 04:54 7727-37-9 353.2 Nitrogen, NO2/NO3 unpres Analytical Method: EPA 353.2 Rev 2.0 1993 Pace Analytical Services -Asheville Nitrogen, Nitrate 2.1 mg/L 0.040 1 09/07/23 00:56 14797-55-8 365.1 Phosphorus, Total Analytical Method: EPA 365.1 Rev 2.0 1993 Preparation Method: EPA 365.1 Rev 2.0 1993 Pace Analytical Services -Asheville Phosphorus 7.9 mg/L 0.15 3 09/15/2318:14 09/18/2313:41 7723-14-0 Date: 09/19/2023 04:06 PM REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, LLC. B2 Page 4 of 17 DocuSign Envelope ID: 1AC346DE-6112-480C-AF72-160AB0096CED Pace Analytical Services, LLC �aceo 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 QUALITY CONTROL DATA Project: FOREST LAKE -MONTHLY Pace Project No.: 92686316 QC Batch: 798130 Analysis Method: SM 9222D-2015 QC Batch Method: SM 9222D-2015 Analysis Description: 9222D Fecal Coliform(MF) - CHT Laboratory: Pace Analytical Services - Charlotte Associated Lab Samples: 92686316001 METHOD BLANK: 4134028 Matrix: Water Associated Lab Samples: 92686316001 Blank Reporting Parameter Units Result Limit Analyzed Qualifiers Fecal Coliforms CFU/100 mL ND 1.0 09/07/23 14:13 SAMPLE DUPLICATE: 4134029 Parameter Fecal Coliforms 92686248005 Dup Units Result Result RPD Qualifiers CFU/100 mL ND ND Results presented on this page are in the units indicated by the "Units" column except where an alternate unit is presented to the right of the result. REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, Date: 09/19/2023 04:06 PM without the written consent of Pace Analytical Services, LLC. Page 5 of 17 DocuSign Envelope ID: 1AC346DE-6112-480C-AF72-160AB0096CED Pace Analytical Services, LLC �aceo 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 QUALITY CONTROL DATA Project: FOREST LAKE -MONTHLY Pace Project No.: 92686316 QC Batch: 798255 Analysis Method: SM 2540C-2015 QC Batch Method: SM 2540C-2015 Analysis Description: 2540C Total Dissolved Solids Laboratory: Pace Analytical Services -Asheville Associated Lab Samples: 92686316001 METHOD BLANK: 4134451 Associated Lab Samples: 92686316001 Parameter Units Total Dissolved Solids mg/L LABORATORY CONTROL SAMPLE: 4134452 Parameter Units Total Dissolved Solids mg/L SAMPLE DUPLICATE: 4134453 Parameter Units Total Dissolved Solids mg/L Matrix: Water Blank Reporting Result Limit Analyzed Qualifiers ND 25.0 09/07/23 12:47 Spike LCS LCS % Rec Conc. Result % Rec Limits Qualifiers 250 266 106 90-110 92686339001 Dup Result Result RPD Qualifiers 33.0 33.0 0 SAMPLE DUPLICATE: 4135298 92686469001 Dup Parameter Units Result Result Total Dissolved Solids mg/L 744 723 RPD Qualifiers 3 Results presented on this page are in the units indicated by the "Units" column except where an alternate unit is presented to the right of the result. REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, Date: 09/19/2023 04:06 PM without the written consent of Pace Analytical Services, LLC. Page 6 of 17 DocuSign Envelope ID: 1AC346DE-6112-480C-AF72-160AB0096CED Pace Analytical Services, LLC �aceo 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 QUALITY CONTROL DATA Project: FOREST LAKE -MONTHLY Pace Project No.: 92686316 QC Batch: 798259 Analysis Method: SM 2540D-2015 QC Batch Method: SM 2540D-2015 Analysis Description: 2540D Total Suspended Solids Laboratory: Pace Analytical Services -Asheville Associated Lab Samples: 92686316001 METHOD BLANK: 4134460 Associated Lab Samples: 92686316001 Parameter Units Total Suspended Solids mg/L LABORATORY CONTROL SAMPLE: 4134461 Parameter Units Total Suspended Solids mg/L SAMPLE DUPLICATE: 4134690 Parameter Units Total Suspended Solids mg/L Matrix: Water Blank Reporting Result Limit Analyzed Qualifiers ND 2.5 09/07/23 12:36 Spike LCS LCS % Rec Conc. Result % Rec Limits Qualifiers 250 250 100 90-110 92686307003 Dup Result Result RPD Qualifiers 7900 7500 5 SAMPLE DUPLICATE: 4134691 92686394003 Dup Parameter Units Result Result Total Suspended Solids mg/L 75.0 78.0 RPD Qualifiers 4 Results presented on this page are in the units indicated by the "Units" column except where an alternate unit is presented to the right of the result. REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, Date: 09/19/2023 04:06 PM without the written consent of Pace Analytical Services, LLC. Page 7 of 17 DocuSign Envelope ID: 1AC346DE-6112-480C-AF72-160AB0096CED Pace Analytical Services, LLC �aceo 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 QUALITY CONTROL DATA Project: FOREST LAKE -MONTHLY Pace Project No.: 92686316 QC Batch: 798313 Analysis Method: SM 521 OB-2016 QC Batch Method: SM 521OB-2016 Analysis Description: 5210E BOD, 5 day Laboratory: Pace Analytical Services -Asheville Associated Lab Samples: 92686316001 METHOD BLANK: 4134876 Associated Lab Samples: 92686316001 Parameter Units BOD, 5 day mg/L LABORATORY CONTROL SAMPLE: 4134878 Parameter Units BOD, 5 day mg/L SAMPLE DUPLICATE: 4134879 Parameter Units BOD, 5 day mg/L Matrix: Water Blank Reporting Result Limit Analyzed Qualifiers ND 2.0 09/12/23 23:33 Spike LCS LCS % Rec Conc. Result % Rec Limits Qualifiers 198 189 96 84.6-115 92686373001 Dup Result Result RPD Qualifiers 199 188 6 Results presented on this page are in the units indicated by the "Units" column except where an alternate unit is presented to the right of the result. REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, Date: 09/19/2023 04:06 PM without the written consent of Pace Analytical Services, LLC. Page 8 of 17 DocuSign Envelope ID: 1AC346DE-6112-480C-AF72-160AB0096CED Pace Analytical Services, LLC �aceo 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 QUALITY CONTROL DATA Project: FOREST LAKE -MONTHLY Pace Project No.: 92686316 QC Batch: 799900 Analysis Method: EPA 350.1 Rev 2.0 1993 QC Batch Method: EPA 350.1 Rev 2.0 1993 Analysis Description: 350.1 Ammonia Laboratory: Pace Analytical Services -Asheville Associated Lab Samples: 92686316001 METHOD BLANK: 4143292 Associated Lab Samples: 92686316001 Parameter Units Nitrogen, Ammonia mg/L LABORATORY CONTROL SAMPLE: 4143293 Parameter Units Nitrogen, Ammonia mg/L Matrix: Water Blank Reporting Result Limit Analyzed Qualifiers ND 0.10 09/16/2311:57 Spike LCS LCS % Rec Conc. Result % Rec Limits Qualifiers 5 5.0 101 90-110 MATRIX SPIKE & MATRIX SPIKE DUPLICATE: 4143294 4143295 MS MSD 92686582002 Spike Spike MS MSD MS MSD % Rec Parameter Units Result Conc. Conc. Result Result % Rec % Rec Limits RPD Qual Nitrogen, Ammonia mg/L ND 5 5 5.1 5.2 103 103 90-110 0 MATRIX SPIKE & MATRIX SPIKE DUPLICATE: 4143296 4143297 MS MSD 92686582003 Spike Spike MS MSD MS MSD % Rec Parameter Units Result Conc. Conc. Result Result % Rec % Rec Limits RPD Qual Nitrogen, Ammonia mg/L 4.0 5 5 9.0 9.1 100 102 90-110 1 Results presented on this page are in the units indicated by the "Units" column except where an alternate unit is presented to the right of the result. REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, Date: 09/19/2023 04:06 PM without the written consent of Pace Analytical Services, LLC. Page 9 of 17 DocuSign Envelope ID: 1AC346DE-6112-480C-AF72-160AB0096CED Pace Analytical Services, LLC �aceo 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 QUALITY CONTROL DATA Project: FOREST LAKE -MONTHLY Pace Project No.: 92686316 QC Batch: 799689 Analysis Method: EPA 351.2 Rev 2.0 1993 QC Batch Method: EPA 351.2 Rev 2.0 1993 Analysis Description: 351.2 TKN Laboratory: Pace Analytical Services -Asheville Associated Lab Samples: 92686316001 METHOD BLANK: 4141962 Associated Lab Samples: 92686316001 Parameter Units Nitrogen, Kjeldahl, Total mg/L LABORATORY CONTROL SAMPLE: 4141963 Parameter Units Nitrogen, Kjeldahl, Total mg/L Matrix: Water Blank Reporting Result Limit Analyzed Qualifiers ND 0.50 09/19/23 04:40 Spike LCS LCS % Rec Conc. Result % Rec Limits Qualifiers 10 10.3 103 90-110 MATRIX SPIKE & MATRIX SPIKE DUPLICATE: 4145494 4145495 MS MSD 92686373001 Spike Spike MS MSD MS MSD % Rec Parameter Units Result Conc. Conc. Result Result % Rec % Rec Limits RPD Qual Nitrogen, Kjeldahl, Total mg/L 26.0 10 10 34.6 36.1 86 101 90-110 4 M1 MATRIX SPIKE & MATRIX SPIKE DUPLICATE: 4145496 4145497 MS MSD 92686380001 Spike Spike MS MSD MS MSD % Rec Parameter Units Result Conc. Conc. Result Result % Rec % Rec Limits RPD Qual Nitrogen, Kjeldahl, Total mg/L 19.6 10 10 29.5 29.9 98 103 90-110 1 Results presented on this page are in the units indicated by the "Units" column except where an alternate unit is presented to the right of the result. REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, Date: 09/19/2023 04:06 PM without the written consent of Pace Analytical Services, LLC. Page 10 of 17 DocuSign Envelope ID: 1AC346DE-6112-480C-AF72-160AB0096CED Pace Analytical Services, LLC �aceo 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 QUALITY CONTROL DATA Project: FOREST LAKE -MONTHLY Pace Project No.: 92686316 QC Batch: 798162 Analysis Method: EPA 353.2 Rev 2.0 1993 QC Batch Method: EPA 353.2 Rev 2.0 1993 Analysis Description: 353.2 Nitrate + Nitrite, Unpres. Laboratory: Pace Analytical Services -Asheville Associated Lab Samples: 92686316001 METHOD BLANK: 4134153 Associated Lab Samples: 92686316001 Parameter Units Nitrogen, Nitrate mg/L LABORATORY CONTROL SAMPLE: 4134154 Parameter Units Nitrogen, Nitrate mg/L Matrix: Water Blank Reporting Result Limit Analyzed Qualifiers ND 0.040 09/07/23 00:43 Spike LCS LCS % Rec Conc. Result % Rec Limits Qualifiers 1.5 1.5 98 90-110 MATRIX SPIKE & MATRIX SPIKE DUPLICATE: 4134155 4134156 MS MSD 92686303001 Spike Spike MS MSD MS MSD % Rec Parameter Units Result Conc. Conc. Result Result % Rec % Rec Limits RPD Qual Nitrogen, Nitrate mg/L ND 1.5 1.5 1.5 1.5 98 98 90-110 1 Results presented on this page are in the units indicated by the "Units" column except where an alternate unit is presented to the right of the result. REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, Date: 09/19/2023 04:06 PM without the written consent of Pace Analytical Services, LLC. Page 11 of 17 DocuSign Envelope ID: 1AC346DE-6112-480C-AF72-160AB0096CED Pace Analytical Services, LLC �aceo 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 QUALITY CONTROL DATA Project: FOREST LAKE -MONTHLY Pace Project No.: 92686316 QC Batch: 799958 Analysis Method: EPA 365.1 Rev 2.0 1993 QC Batch Method: EPA 365.1 Rev 2.0 1993 Analysis Description: 365.1 Phosphorus, Total Laboratory: Pace Analytical Services -Asheville Associated Lab Samples: 92686316001 METHOD BLANK: 4143496 Associated Lab Samples: 92686316001 Parameter Units Phosphorus mg/L LABORATORY CONTROL SAMPLE: 4143497 Parameter Units Phosphorus mg/L Matrix: Water Blank Reporting Result Limit Analyzed Qualifiers ND 0.050 09/18/2313:30 Spike LCS LCS % Rec Conc. Result % Rec Limits Qualifiers 2.5 2.4 96 90-110 MATRIX SPIKE & MATRIX SPIKE DUPLICATE: 4143498 4143499 MS MSD 92686244001 Spike Spike MS MSD MS MSD % Rec Parameter Units Result Conc. Conc. Result Result % Rec % Rec Limits RPD Qual Phosphorus mg/L 5.6 2.5 2.5 7.7 5.4 84 -8 90-110 35 M1,R1 MATRIX SPIKE & MATRIX SPIKE DUPLICATE: 4143500 4143501 MS MSD 92686296003 Spike Spike MS MSD MS MSD % Rec Parameter Units Result Conc. Conc. Result Result % Rec % Rec Limits RPD Qual Phosphorus mg/L 0.037J 2.5 2.5 2.6 2.4 101 96 90-110 5 Results presented on this page are in the units indicated by the "Units" column except where an alternate unit is presented to the right of the result. REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, Date: 09/19/2023 04:06 PM without the written consent of Pace Analytical Services, LLC. Page 12 of 17 DocuSign Envelope ID: 1AC346DE-6112-480C-AF72-160AB0096CED Pace Analytical Services, LLC �aceo 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 QUALIFIERS Project: FOREST LAKE -MONTHLY Pace Project No.: 92686316 DEFINITIONS DF - Dilution Factor, if reported, represents the factor applied to the reported data due to dilution of the sample aliquot. ND - Not Detected at or above adjusted reporting limit. TNTC - Too Numerous To Count J - Estimated concentration above the adjusted method detection limit and below the adjusted reporting limit. MDL -Adjusted Method Detection Limit. PQL - Practical Quantitation Limit. RL - Reporting Limit - The lowest concentration value that meets project requirements for quantitative data with known precision and bias for a specific analyte in a specific matrix. S - Surrogate 1,2-Diphenylhydrazine decomposes to and cannot be separated from Azobenzene using Method 8270. The result for each analyte is a combined concentration. Consistent with EPA guidelines, unrounded data are displayed and have been used to calculate % recovery and RPD values. LCS(D) - Laboratory Control Sample (Duplicate) MS(D) - Matrix Spike (Duplicate) DUP - Sample Duplicate RPD - Relative Percent Difference NC - Not Calculable. SG - Silica Gel - Clean -Up U - Indicates the compound was analyzed for, but not detected. Acid preservation may not be appropriate for 2 Chloroethylvinyl ether. A separate vial preserved to a pH of 4-5 is recommended in SW846 Chapter 4 for the analysis of Acrolein and Acrylonitrile by EPA Method 8260. N-Nitrosodiphenylamine decomposes and cannot be separated from Diphenylamine using Method 8270. The result reported for each analyte is a combined concentration. Reported results are not rounded until the final step prior to reporting. Therefore, calculated parameters that are typically reported as "Total" may vary slightly from the sum of the reported component parameters. Pace Analytical is TNI accredited. Contact your Pace PM for the current list of accredited analytes. TN -The NELAC Institute. ANALYTE QUALIFIERS B2 Oxygen usage is less than 2.0 for all dilutions set. The reported value is an estimated less than value and is calculated for the dilution using the most amount of sample. M1 Matrix spike recovery exceeded QC limits. Batch accepted based on laboratory control sample (LCS) recovery. R1 RPD value was outside control limits. REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, Date: 09/19/2023 04:06 PM without the written consent of Pace Analytical Services, LLC. Page 13 of 17 DocuSign Envelope ID: 1AC346DE-6112-480C-AF72-160AB0096CED aceo Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 QUALITY CONTROL DATA CROSS REFERENCE TABLE Project: Pace Project No.: FOREST LAKE -MONTHLY 92686316 Analytical Lab ID Sample ID QC Batch Method QC Batch Analytical Method Batch 92686316001 EFFLUENT GRAB SM 9222D-2015 798130 SM 9222D-2015 798131 92686316001 EFFLUENT GRAB SM 254OC-2015 798255 92686316001 EFFLUENT GRAB SM 2540D-2015 798259 92686316001 EFFLUENT GRAB SM 521 OB-2016 798313 SM 521 OB-2016 798456 92686316001 EFFLUENT GRAB TKN+NO3+NO2 800571 Calculation 92686316001 EFFLUENT GRAB EPA 350.1 Rev 2.0 1993 799900 92686316001 EFFLUENT GRAB EPA 351.2 Rev 2.0 1993 799689 EPA 351.2 Rev 2.0 1993 800538 92686316001 EFFLUENT GRAB EPA 353.2 Rev 2.0 1993 798162 92686316001 EFFLUENT GRAB EPA 365.1 Rev 2.0 1993 799958 EPA 365.1 Rev 2.0 1993 800235 Date: 09/19/2023 04:06 PM REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, LLC. Page 14 of 17 I .-,W _ _ I u%.ff i ttie: r_trv-rmm nun, t uutss vuz ,Jampfe uonattion upon Kecelpt DocuSign Envelope ID: 1AC346DE-6112-480C-AF72-160AB0096CED Effective Date: 11/14/2022 1 Laboratory receiving samples: — Asheville ❑ Eden❑ Greenwood ❑ Huntersvill�Raleigh❑ Mechanicsvillen Atlant- 71 SampleClient Name: 16 Upon Receipt � L� � 1l,t Project "/�o;s tt:Wo#:926863 Courier: ❑Fed Ex ❑UPS ❑USPS []Client I IIIII I IIIII IIIIII I III ❑ Commercial ,Pace ❑Other: 316 82686 J Custody Seal Present? ❑Yes _P - Seals Intact? ❑Yes 0-No T / Date/Initials Person Examining Contents: Packing Material: [-]Bubble Wrap ❑Bubble Bags JLAicrne ❑ Other Biological Tissue F oxen? Thermometer: ❑Yes ❑No �9 RGun ID: t'V N Type of Ice: �t ❑Blue ❑None Cooler Temp: A, Correction Factor: U Add/Subtract (°C) Temp should be above freezing to 6°C ❑Samples out of temp criteria. Samples on ice, cooling process Cooler Temp Corrected (°C): has begun USDA Regulated Soil (J2N/A, water sample) Did samples originate in a quarantine zone .vithm the United States: CA, NY, or SC Did samples originate from a foreign source (interna . nally, (check maosl? MYes No ��� •d �e u,,,,,ii � 4 D,,, "_ o , w rlv-. .._ Comments/Discrepancy: —� Chain of Custody Present? Ycs ❑No ❑N/A 1. Samples Arrived within Hold Time? es ONO ❑N/A 2. Short Hold Time Analysis (02 hr.)? . —Yes []No ❑N/A 3. Rush Turn Around Time Requested? ❑Yes ❑No -2tq-/A 4. Sufficient Volume? es ❑No ❑N/A S. Correct Containers Used? -Pace Containers Used? -In-yes es ❑Na ❑No ❑N/A ❑N/A 6. Containers Intact? ,,E5Yes []No ❑N/A 7. Dissolved analysis: Samples Field Filtered? ❑Yes [:)No I�ntA B. Sample Labels Match COC? -Includes Date/Time/ID/Analysis Matrix: Yes W—T ❑No ❑N/A 9. in VOA Vials (>S-6mm)? []Yes[-]NoIQry1A 10. rHeadspace Trip Blank Present? Trip Blank Custody Seals Present? ❑Yes ❑Yes []No []No N/A /n 11. COMMENTS/SAMPLE DISCREPANCY CLIENT NOTIFICATION/RESOLUTION Person contacted: Project Manager SCURF Review: Project Manager SRF Review: Qualtrax ID: 69614 Lot ID of split containers: Date/Time. Field Data Required? ❑Yes ❑No Date: Date: Page 1 of 2 Page 15 of 17 1 /fry _ _ I "`'ff—i itte: Ctvv-rmm-nury i-uuo3 vuc_zi,ample conaltfon upon Kecelpt DocuSign Envelope ID: 1AC346DE-6112-480C-AF72-160AB0096CED Effective Date: 11/14/2022 `Check mark top half of box if pH and/or dechlorination is verified and within the acceptance range for preservation samples. Exceptions: VOA, Coliform, TOC, Oil and Grease, DRO/8015 (water) DOC. LLHg "Bottom half of box is to list number of bottles ***Check all unpreserved Nitrates for chlorine Project t# ^ WO# : 92686316 PM: MWB Due Date: 09/21/23 CLIENT: 92-Greener z 2 Z 2 Z z ¢ -o or 7- v N v v = O z .3 -1 u ry ^ a v 2 W v n U — ¢ z v a _ v ¢ z moo, ;; Q. ° `—' Z z z y < a ? Q = M l Z t Z iz o; Q1 O a v v z N v 2 M c v a c y n c u a a U N = O z ¢ z u O ° v L ° O S n 2 n O r = v ON z _ '? Z Z U p N 2 r c 2 p m . v a O t3 M M ._. « s a 5 o a ry N = ? a c _� > o v c O a J E In rH ."� a J E o ,n N a - E o O In in a o, - .••, —° J E n r� a J E o In N J E u� ry E v1 r� O E °_' E Q li y 'ti E Q v _ — r1 ¢ - E o 'n N E ° — E J p n E Q J E O O > - E O V Q > J E p O > J E O 7 0 O J E O FL - E O m a LI m en NI J E u1 N ; N E O In 2 a E O InXC E ¢ J of O c U J E O E E J E O E 01 _ V a m M a Co N a co �•1 a a a co13 M n. ti Q a m .ti C a co3 LL r-1 to Q r1 to Q M to ¢ .-I -1 0 Q N M U Q 7 M t7 o 01 (D o O Q1 0 > OI V• > Q 01 Q o d sc \ > ,••1 0. 0 tV ry LA M m O a = In > ON W 3 4NN \ \ — -- 5 6 7 i 3 N I I \ I \ 9 I I 10 I1 i 12 pH Adjustment Log for Preserved Samples Sample ID Type of Preservative pH upon receipt Date preservation adjusted Time preservation adjusted Amount of Preservative added lot # >• �N�• �x o ,c�uug n�, u1 a1 Vnno cvnlpndnce 5dmples, d copy or cnls Corm will oe sent to the North Carolina DENR Certification Office (i.e. Out of hold, incorrect preservative, out of temp, incorrect containers. Qualtrax ID. 69614 Page 2 of 2 Page 16 of 17 CHAIN -OF -CUSTODY 1 Analytical Request Document ace The Chain -of -Custody is a LEGAL DOCUMENT. All relevant fields must be completed accurately. Submitting a sample via this chain of custody constitutes acknowledgment and acceptance of the Pace Terms and Conditions found at https://info.pacclabs-com/hubfs/pas-standard-terms.pdf, Section A Section B Section C Required Client Information: Required Project Information: Invoice Information: Page : 1 Of 1 Company: Greener EHS Solutions Report To: Amanda Grenier Attention: Address: 338 Pea Ridge Road Copy To: Company Name: New Hill. NC 27562 Address: Regulatory Agency Email: agrenier@greenerehssolulions.com Purchase Order k: Pace Quote: Phone: (919)356-6509 JFax Project Name: Forest Lake- Monthly Pace Project Manager: matthew.brainard@pacelabs.com, State! Location Requested Due Date: Project #: Pace Profile It: 14849-8 NC Requested Anal sis Filtered Y(N o a Z MATRIX CODE _ COLLECTED Z Preservatives >- Dt.M,nq Watu DW b D 0 0 F W.I. VW Q U U Ylosie Ylalw W1V Pr M.1 P o.SL SAMPLE ID Sus _ OK OJ N aalm z Y T od OL O_ START END One Character per box. %V'W WP w w a z E D- _o (A-Z, 0-9 / -j Ai, AR olhw OT Sample Ids must be unique Tissuo Ts 0 0 0 x r w TIATETl.1 w < Z O N Z �' o c� Ln _� to m u; O '- c� M1 m o t U Wa H a a a a O n OU Z U m v E 'o `° n DATE TIME _ _ = z z :,EO m u- ¢ r Z IU- fY 2 3 4 i Lu v co 0 0 0 ao 0 0 o N r� — LL Q U — CD W V — N ADDITIONAL COMMENTS RELINQU16htED8Yt AFFILIATION DATE TIME ACCEPTED BY I AFFILIATION DATE TIME SAMPLE CONDITIONS —C) / Q -o Q O SAMPLER NAME AND SIGNATURE O w O o PRINT Name of SAMPLER: C RJR✓� 1 C'i►\ a v o m n_, SIGNATURE of SAMPLER:^y DATE Signed: �-, z_ �} o z_ } E z_ yU In c?