Loading...
HomeMy WebLinkAboutWQ0044809_Application_20231012State of North Carolina Department of Environmental Quality DWR Division of Water Resources FAST TRACK SEWER SYSTEM EXTENSION APPLICATION Dlvlslon of Water Resources FTA 06-21 & SIJPPORTING DOCUMENTATION NCDept OfEnvironmental ttaiity Application Number: 004q P,0'j (Io be completed by DWR) All items must be completed or the application will be returned OCT 12 M3 1. APPLICANT INFORMATION: RWeigh Regiouai Orifice 1. Applicant's name: Charthouse Holdings, LLC (company, municipality, HOA, utility, etc.) 2. Applicant type: ❑ Individual ® Corporation ❑ General Partnership ❑ Privately -Owned Public Utility ❑ Federal ❑ State/County ❑ Municipal ❑ Other 3. Signature authority's name: Brian D. Gower per 15A NCAC 02T .0106(b) Title: Chief Executive Officer 4. Applicant's mailing address: 8771-B Cleveland Road City: Clayton State: NC Zip: 27520- 5. Applicant's contact information: Phone number: ( 919 ) 291-2135 Email Address: briandgowera[,pmail.com 11. PROJECT INFORMATION: 1. Project name: 8771 Cleveland Road PS & FM 2. Application/Project status: ® Proposed (New Permit) ❑ Existing Permit/Project If a modification, provide the existing permit number: WQ00 and issued date: , For modifications, also attach a detailed narrative description as described in Item G of the checklist. If new construction, but part of a master plan, provide the existing permit number: WQ00 3. County where project is located: Johnston 4. Approximate Coordinates (Decimal Degrees): Latitude: 33.566103 Longitude:-78.525837 5. Parcel ID (if applicable): 164600-01 ..9133 (or Parcel ID to closest downstream sewer) III. CONSULTANT INFORMATION: 1. Professional Engineer: Gary J. McCabe PE License Number: 032614 Firm: Red Line Engineering, PC Mailing address: 123 Raleigh Street City: Fuquay-Varina State: North Carolina Zip: 27526 -_ Phone number: (9J_9) 779-6851 Email Address: ga1y.mccabe0,rlenc.com IV. WASTEWATER TREATMENT FACILITY (WWTF) INFORMATION: I. Facility Name: Central Johnston County Regional Wastewater Facility Permit Number: NCO030716 Owner Name: Johnston County V. RECEIVING DOWNSTREAM SEWER INFORMATION: I. Permit Number(s): WQ0024081 2. Downstream (Receiving) Sewer Information: 2 inch Gravity ® Force Main 3. System Wide Collection System Permit Number(s) (if applicable): WQCS00060 Owner Name(s): Johnston County FORM: FTA 06-21 Page I of 5 VI. GENERAL REQUIREMENTS 1. If the Applicant is a Privately -Owned Public Utility, has a Certificate of Public Convenience and Necessity been attached? ❑ Yes ❑ No ® N:'A 2. If the Applicant is a Developer of lots to be sold, has a Developer's operational Agreement (FORM: DEV} been attached? ❑ Yes ❑ No ® N;'A 3. If the Applicant is a Home/Property Owners' Association, has an HOA.'POA Or, erational AL,reement (FORM: H0A) and supplementary documentation as required by 15A NCAC 02T.0115(c) been attached? ❑ Yes ❑ No ® N.:A 4. Origin of wastewater: (check all that apply): ❑ Residential (Individually Owned) ❑ Retail (stores, centers, malls) ❑ Car Wash ❑ Residential (Leased) ❑ Retail with food preparation/service ❑ Hotel andior Motels ❑ School preschool / day care ❑ Medical l dental i veterinary facilities ❑ Swimming Pool.!Clubhouse ❑ Food and drink facilities ❑ Church ❑ Swimming Poo1/Filter Backwash ® Businesses offices 1 factories ❑ Nursing Home ❑ Other (Explain in Attachment) 5. Nature of wastewater : 100 % Domestic % Commercial °.o Industrial (See 15A NCAC 02T .0103(20)) If Industrial, is there a Pretreatment Program in effect? ❑ Yes® No 6. Hasa flow reduction been approved under 15A NCAC 02T .01 14(f)? [:]Yes ®No ➢ If yes, provide a coov of flow reduction approval letter with this application 7. Summarize wastewater generated by project: Establishment Type (see 02T.0114(f)) Daily Design Flow" No. of Units Flow Business - General Business and Office Facilities 25 gal/Employees/shift 10 250 GPD gall GPD gall GPD gall GPD gall GPD gall GPD Total 250 GPD a See 15A NCAC 02T .01 14(b). fdr, fel(1 i and (e)(2) for caveats to wastewater design flow rates (i.e., minimum flow per dwelling; proposed unknown non-residential development uses; public access facilities located near high public use areas; and residential property located south or east of the Atlantic Intracoastal Waterway to be used as vacation rentals as defined in G.S. 42A-4). b Per I SA NCAC 02T .0114(c), design flow rates for establishments not identified [in table 15A NCAC 02T.01141 shall be determined using available flow data, water using fixtures, occupancy or operation patterns, and other measured data. 8. Wastewater generated by project: 250 GPD (per 1 SA NCAC 02T .0114) ➢ Do not include future flows or previously permitted allocation, If permitted flow is zero, please indicate why: ❑ Pump Station/Force Main or Gravity Sewer where flow will be permitted in subsequent permits that connect to this line. Please provide supplementary information indicating the approximate timeframe for permitting upstream sewers with flow. ❑ Flow has already been allocated in Permit Number: Issuance Date: ❑ Rehabilitation or replacement of existing sewers with no new flow expected ❑ Other (Explain): FORM: FTA 06-21 Page 2 of 5 VI1. GRAVITY SEWER DESIGN CRITERIA (If Applicable) - 02T .0305 & MDC (Gravi4 Sewers): 1. Summarize gravity sewer to be permitted: Size (inches) Length (feet) Material NIA ➢ Section II & III of the MDC for Permitting of Gravity Sewers contains information related to design criteria ➢ Section Ill contains information related to minimum slopes for gravity sewer(s) ➢ Oversizing lines to meet minimum slope requirements is not allowed and a violation of the MDC VIII. PUMP STATION DESIGN CRITERIA (If Applicable) — 02T .0305 & MDC (Pump StationsiForce Mains): PROVIDE A SEPARATE COPY OF THIS PAGE FOR EACH PUMP STATION INCLUDED IN THIS PROJECT 1. Pump station number or name: 8771 Cleveland Road 2. Approximate Coordinates (Decimal Degrees): Latitude: 33.566103 - Longitude:-78.525837" 3. Total number of pumps at the pump station: 1 3. Design flow of the pump station: 0.000250 millions gallons per day (firm capacity) ➢ This should reflect the total GPM for the pump station with the largest pump out of service. 4. Operational point(s) per pump(s): 46 gallons per minute (GPM) at 49 feet total dynamic head (TDH) 5. Summarize the force main to be permitted (for this Pump Station): Size (inches) Length (feet) Material 2 120 PVC If any portion of the force main is less than 4-inches in diameter, please identify the method of solids reduction per MDCPSFM Section 2.01C.1.b. ® Grinder Pump ❑ Mechanical Bar Screen ❑ Other (please specify) 6. Power reliability in accordance with 13A.NCAC 02T .0305(h)( l ): ❑ Standby power source or ❑ Standby pump ➢ Must have automatic activation and telemetry - 15A NCAC 02T.0305(h)(1)(B)_ ➢ Required for all pump stations with an average daily flow greater than or equal to 15,000 gallons per day ➢ Must be permanent to facility and may not be portable Or if the pump station has an average daily flow less than 15,000 gallons per day 15A NCACO2T.0305(h)(1)(C): ❑ Portable power source with manual activation, quick -connection receptacle and telemetry - or ❑ Portable pumping unit with plugged emergency pump connection and telemetry: ➢ Include documentation that the portable source is owned or contracted by the applicant and is compatible with the station. ➢ If the portable power source or pump is dedicated to multiple pump stations, an evaluation of all the pump stations' storage capacities and the rotation schedule of the portable power source or pump, including travel timeframes, shall be provided as part of this permit application in the case of a multiple station power outage. FORM: FTA 06-21 Page 3 of 5 IX. SETBACKS & SEPARATIONS — (02B .0200 & 15A NCAC 02T .0305(f)): 1. Does the project comply with all separations/alternatives found in 15A NCAC 02T .0305M & (g)? ® Yes ❑ No 15A NCAC 02T.0305(f) contains minimum separations that shall be provided for sewer systems: Setback Parameter* Separation Required Storm sewers and other utilities not listed below (vertical) 18 inches '--Water mains (vertical - water over sewer preferred, including in benched trenches) 18 inches 2Water mains (horizontal) 10 feet Reclaimed water lines (vertical - reclaimed over sewer) 18 inches Reclaimed water lines (horizontal - reclaimed over sewer) 2 feet **Any private or public water supply source, including any wells, WS-I waters of Class I or Class 1I impounded reservoirs used as a source of drinking water, and associated wetlands. 100 feet **Waters classified WS (except WS-I or WS-V), B, SA, ORW, HQW, or SB from normal high water (or tide elevation) and wetlands associated with these waters (see item IX.2) 50 feet **Any other stream, lake, impoundment, or ground water lowering and surface drainage ditches, as well as wetlands associated with these waters or classified as WL. 10 feet Any building foundation (horizontal) 5 feet Any basement (horizontal) 10 feet Top slope of embankment or cuts of 2 feet or more vertical height 10 feet Drainage systems and interceptor drains 5 feet Any swimming pools 10 feet Final earth grade (vertical) 36 inches ➢ If noncompliance with 02T.0305M or (g}. see Section X.I of this application * 15A NCAC 02T.0305(Ql contains alternatives where separations in 02T.0305(t cannot be achieved. Please check "yes" above if these alternatives are used and provide narrative information to explain. **Stream classifications can be identified using the Division's NC Surface Water Classifications webipne 2. Does this project comply with the minimum separation requirements for water mains? ®Yes ❑ No ❑ NIA ➢ If no, please refer to 15A NCAC 18C.0906(0 for documentation requirements and submit a separate document, signed/sealed by an NC licensed PE, verifying the criteria outlined in that Rule. 3. Does the project comply with separation requirements for wetlands? ® Yes ❑ No ❑ N.'A ➢ Please provide supplementary information identifying the areas of non-conformance. ➢ See the Division's draft separation reuuirements for situations where separation cannot be met. ➢ No variance is required if the alternative design criteria specified is utilized in design and construction. 4. Is the project located in a river basin subject to any State buffer rules? ® Yes Basin name: Nuese River ❑ No If yes, does the project comply with setbacks found in the river basin rules per 15A NCAC 02B .0200? ® Yes ❑ No ➢ This includes Trout Buffered Streams per 15A NCAC 213.0202 5. Does the project require coverage/authorization under a 404 Nationwideiindividual permits ❑ Yes ® No or 401 Water Quality Certifications? ➢ Please provide the permit number.'permitting status in the cover letter if coverage/authorization is required. 6. Does project comply with 15A NCAC 02T.0 I 05(c)J6) (additional permitsfcertifications)? ® Yes ❑ No Per 15A NCAC 02T.0 I 05(c)(6), directly related environmental permits or certification applications must be being prepared, have been applied for, or have been obtained. Issuance of this permit is contingent on issuance of dependent permits (erosion and sedimentation control plans, stormwater management plans, etc.). 7. Does this project include any sewer collection lines that are deemed "high -priority?" ❑ Yes ® No Per 1 SA NCAC 02T.0402, "high -priority sewer" means any aerial sewer, sewer contacting surface waters, siphon, or sewers positioned parallel to streambanks that are subject to erosion that undermines or deteriorates the sewer. Siphons and sewers suspended through interference/conflict boxes require a variance approval. ➢ If yes, include an attachment with details for each line, including type (aerial line, size, material, and location). High priority lines shall be inspected by the permittee or its representative at least once every six -months and inspections documented per 15A NCAC 02T.0403(a)(5) or the permittee's individual System -Wide Collection permit. FORM: FTA 06-21 Page 4 of 5 X. CERTIFICATIONS: 1. Does the submitted system comply with 15A NCAC 02T, the Minimum Designn _ Criteria for the Permitting of Pump Statios and Force Mains t latest version), and the Gravity Sewer Minimum Design_Criteria (latest version) as applicable? ® Yes ❑ No If no, for projects requiring a single variance, complete and submit the VariancefAlternative Design Request application (VADC 10-14) and supporting documents for review to the Central Office. Approval of the request will be issued concurrently with the approval of the permit, and projects requiring a variance approval may be subject to longer review times. For projects requiring two or more variances or where the variance is determined by the Division to be a_ significant portion of the project, the full technical review is required. 2. Professional Engineer's Certification: I, _Gary J. McCabe, PE _ , attest that this application for 8817 Cleveland Road PS & FM (Professional Engineer's name from Application Item Ili.)_) (Project Name from Application Item Il.l ) has been reviewed by me and is accurate, complete and consistent with the information supplied in the plans, specifications, engineering calculations, and all other supporting documentation to the best of my knowledge. I further attest that to the best of my knowledge the proposed design has been prepared in accordance with the applicable regulations, Minimum Design Criteria for Gravity Sewers (latest version), and the MinimumDesign Criteria for the Fast -Track Permitting of Pumn Stations and Force Mains (latest version). Although other professionals may have developed certain portions of this submittal package, inclusion of these materials under my signature and seal signifies that I have reviewed this material and have judged it to be consistent with the proposed design. NOTE — In accordance with General Statutes 143-215.6A and 143-215.613, any person who knowingly makes any false statement, representation, or certification in any application package shall be guilty of a Class 2 misdemeanor, which may include a fine not to exceed $10,000, as well as civil penalties up to $25,000 per violation. Misrepresentation of the application information, including failure to disclose any design non-compliance with the applicable Rules and design criteria, may subject the North Carolina -licensed Professional Engineer to referral to the licensing board. (21 NCC 56.07t) North Carolina Professional Engineer's seal, signature, and date: '•., a� S� 032614 V1 It 3. Applicant's Certification per 15A NCAC 02T .0106(b): 10/11/2023 I, Brian D. Gower , attest that this application for 8771 Cleveland Road PS & FM (Signature Authority Name from Application Item I.3.) (Project Name from Application Item 11. I i attest that this application has been reviewed by me and is accurate and complete to the best of my knowledge. I understand that if all required parts of this application are not completed and that if all required supporting documentation and attachments are not included, this application package is subject to being returned as incomplete. I understand that any discharge of wastewater from this non -discharge system to surface waters or the land will result in an immediate enforcement action that may include civil penalties, injunctive relief, and/or criminal prosecution. I will make no claim against the Division of Water Resources should a condition of this permit be violated. I also understand that if all required parts of this application package are not completed and that if all required supporting information and attachments are not included, this application package will be returned to me as incomplete. NOTE — In accordance with General Statutes 143-215.6A and 143-215.6% any person who knowingly makes any false statement, representation, or certification in any application package shall be guilty of a Class 2 misdemeanor, which may include a fine not to exceed $10,000 as well as civil penalties up to $25,000 per violation. Signature: Date: FORM: FTA 06-21 Page 5 of 5 State of North Carolina Department of Environmental Quality DWR Division of Water Resources FAST TRACK SEWER SYSTEM EXTENSION APPLICATION Division of Water Resources INSTRUCTIONS FOR FORM: FTA 06-21 & SUPPORTING DOCUMENTATION This application is for sewer extensions involving gravity sewers, pump stations and force mains, or any combination that has been certified by a professional engineer and the applicant that the project meets the requirements of 15A NCAC 02T and the Division's Minimum Design Criteria (Gravity Sewer & Pump Stations,`F'orce Mains) and that plans, specifications and supporting documents have been prepared in accordance with 15A NCAC 02T, 15A NCAC 02T .0300, Division policies, and t_ood engineering aractices. While no upfront engineering design documents are required for submittal, in accordance with 15A NCAC 02T .0305(b), design documents must be prepared prior to submittal of a fast track permit application to the Division. This would include plans, design calculations, and project specifications referenced in 15A NCAC 02T .0305 and the applicable minimum design criteria. These documents shall be immediately available upon request by the Division. Projects that are deemed permitted (do not require a permit from the Division) are explained in 15A N{'AC 02T.0303. Projects not eligible for review via the fast track process (must be submitted for full technical review): ➢ Projects that do not meet any part of the minimum design criteria (MDC) documents; ➢ Projects that involve more than one variance from the requirements of 15A NCAC 02T; ➢ Pressure sewer systems utilizing simplex septic tank -effluent pumps (STEPS) or simplex grinder pumps; ➢ Simplex STEP or simplex grinder pumps connecting to pressurized systems (e.g. force mains); ➢ Vacuum sewer systems. General - When submitting an application, please use the following instructions as a checklist in order to ensure all required items are submitted. Adherence to these instructions and checking the provided boxes will help produce a quicker review time and reduce the amount of requested additional information. Failure to submit all required items will necessitate additional processing and review time, and may result in return of the application. Unless otherwise noted, the Applicant shall submit one original and one copy of the application and supporting documentation. A. One Original and One Copy (second copy may be digital) of Application and Supporting Documents ® Required unless otherwise noted. Signatures on original must be "wet ink" or secure digital signatures. Please do not submit engineering design plans with the application unless specifically requested. B. Cover Letter/Narrative Description (Required for All Application Packages): El List all items included in the application package, as well as a brief description of the requested permitting action. ➢ Be specific as to the system type, number of homes served, flow allocation required, etc. ➢ Include the permit numbenstatus of any other required sewer permits (downstream/upstream) ➢ If necessary for clarity, include attachments to the application form. C. Application Fee (All New and Modification Application Packages): ® Submit a check or money order in the amount of $480.00, dated no more than 90 days prior to application submittal. ➢ Payable to North Carolina Department of Environmental Quality (NCDEQ) D. Fast Track Application (Required for All Application Packages, Form FTA 05-21): ® Submit the completed and appropriately executed application. ➢ If necessary for clarity or due to space restrictions, attachments to the application may be made. ® If the Applicant Type in Item 1.2 is a corporation or company, provide documentation it is registered for business with the North Carolina Secretary of State. ❑ If the Applicant Type in Item I.2 is a partnership or d/bia, enclose a copy of the certificate filed with the Register of Deeds in the county of business. ® The Project Name in Item It.I shall be consistent with the project name on the flow acceptance letters, agreements, etc. ® The Professional Engineer's Certification on Page 5 of the application shall be signed, sealed and dated by a North Carolina licensed Professional Engineer. ® The Applicant's Certification on Page 5 of the application shall be signed in accordance with .15A NCAC 02T .0106(b1. Per 15A NCAC 02T .0106(c), an alternate person may be designated as the signing official if a delegation letter is provided from a person who meets the criteria in 15A NCAC 02T .0106(b). INSTRUCTIONS FOR FORM: FTA 06-21 & SUPPORTING DOCUMENTATION Page] of 3 E. Flow Tracking/Acceptance Form (Form: FTSE 04-16) (If Applicable): ® Submit the completed and executed FTSE form from the owners of the downstream sewers and treatment facility, ➢ Multiple forms maybe required where the downstream sewer owner and wastewater treatment facility are different. ➢ The flow acceptance indicated in form FTSE must not expire prior to permit issuance and must be dated less than one year prior to the application date. ➢ Submittal of this application and form FTSE indicates that owner has adequate capacity and will not violate. I43-215.67{al. ➢ Intergovernmental agreements or other contracts will not be accepted in lieu of a project -specific FTSE. F. Site Maps (All Application Packages): ® Submit an 8.5-inch x 1 1-inch color copy of a USGS Topographic Map of sufficient scale to identify the entire project area, including the closest surface waters. ➢ General location of the project components (gravity sewer, pump stations, & force main) ➢ Downstream connection points and permit number (if known) for the receiving sewer ® Include an aerial location map showing general project area (such as street names or latitude/longitude) so that Division staff can easily locate it in the field. G. Existing Permit (Application Packages for Modifications to an Existing Permit): ❑ Submit a copy of the most recently issued existing permit. ❑ Include a descriptive and clear narrative identifying the previously permitted items to remain in the permit, items to be added, and/or items to be modified (the application form itself should include only include items to be added/modified). The narrative should also include whether any previously permitted items have been certified. ❑ The narrative should clearly identify the requested permitting action and accurately describe the sewers to be listed in the final permit. H. Power Reliability Plan (Required if portable reliability option utilized for Pump Station): ❑ Per 15A NCAC 02T .0305(h)(1), submit documentation of power reliability for pumping stations. ➢ This alternative is only available for average daily flows less than 15,000 gallons per day ➢ It shall be demonstrated to the Division that the portable source is owned or contracted by the applicant and is compatible with the station. The Division will accept a letter signed by the applicant (see 15A NCAC 02T .0106(b)) or proposed contractor, stating that "the portable power generation unit or portable, independently -powered pumping units, associated appurtenances and personnel are available for distribution and operation of this pump station." ➢ If the portable power source or pump is dedicated to multiple pump stations, an evaluation of all the pump stations' storage capacities and the rotation schedule of the portable power source or pump, including travel timeframes, shall be provided in the case of a multiple station power outage. (Required at time of certification) 1. Certificate of Public Convenience and Necessity (All Application Packages for Privately -Owned Public Utilities): ❑ Per II5A NCAC 02T .0l 15(a)(1) provide the Certificate of Public Convenience and Necessity from the North Carolina Utilities Commission demonstrating the Applicant is authorized to hold the utility franchise for the area to be served by the sewer extension, or ❑ Provide a letter from the North Carolina Commission's Water and Sewer Division Public Staff stating an application for a franchise has been received and that the service area is contiguous to an existing franchised area or that franchise approval is expected. Operational Agreements (Applications from HOA/POA and Developers for lots to be sold): ❑ Home/Property Owners' Associations ❑ Per 15A NCAC 02T .0115(cj, submit the properly executed Operational Agreement ( FORM: 140A). ❑ Per 15A NCAC 02T .01 15(c), submit a copy of the Articles of Incorporation, Declarations and By-laws. ❑ Developers of lots to be sold ❑ Per.15A. N('AC 02T .01 1 *lb), submit the properly executed Operational Agreement (FORM: DEV). For more information, visit the Division's collection systems website INSTRUCTIONS FOR FORM: FTA 05-21 & SUPPORTING DOCUMENTATION Page 2 of 3 THE COMPLETED APPLICATION PACKAGE INCLDING ALL SUPPORTING INFORMATION AND MATERIALS, SHOULD BE SENT TO THE APPROPRIATE REGIONAL OFFICE: REGIONAL OFFICE ADDRESS COUNTIES SERVED Asheville Regional Office 2090 US Highway 70 Avery, Buncombe, Burke, Caldwell, Cherokee, Water Quality Section Swannanoa, North Carolina 28778-8211 Clay, Graham, Haywood, Henderson, Jackson, (828) 296-4500 Macon, Madison, McDowell, Mitchell, Polk, (828) 299-7043 Fax Rutherford, Swain, Transylvania, Yancey Fayetteville Regional Office 225 Green Street Suite 714 Anson, Bladen, Cumberland, Harnett, Hoke, Water Quality Section Fayetteville, North Carolina 28301-5095 Montgomery, Moore, Robeson, Richmond, (910) 433-3300 Sampson, Scotland (910) 486-0707 Fax Mooresville Regional Office 610 E. Center Avenue Alexander, Cabarrus, Catawba, Cleveland, Water Quality Section Mooresville, North Carolina 28115 Gaston, Iredell, Lincoln, Mecklenburg, Rowan, (704) 663-1699 Stanly, Union (704) 663-6040 Fax j Raleigh Regional Office 3800 Barrett Drive Chatham, Durham, Edgecombe, Franklin, j Water Quality Section Raleigh, North Carolina 27609 Granville, Halifax, Johnston, Lee, Nash, (919) 7914200 Northampton, Orange, Person, Vance, Wake, (919) 571-4718 Fax Warren, Wilson Washington Regional Office 943 Washington Square Mall Beaufort, Bertie, Camden, Chowan, Craven, Water Quality Section Washington, North Carolina 27889 Currituck, Dare, Gates, Greene, Hertford, Hyde, (252) 946-6481 Jones, Lenoir, Martin, Pamlico, Pasquotank, (252) 975-3716 Fax Perquimans, Pitt, Tyrrell, Washington, Wayne Wilmington Regional Office 127 Cardinal Drive Extension Brunswick, Carteret, Columbus, Duplin, New Water Quality Section Wilmington, North Carolina 28405 Hanover, Onslow, Pender (910) 796-7215 (910) 350-2004 Fax Winston-Salem Regional Office 450 W. Hanes Mill Road Alamance, Alleghany, Ashe, Caswell, Davidson, Water Quality Section Suite 300 Davie, Forsyth, Guilford, Rockingham, Randolph, Winston-Salem, North Carolina 27105 Stokes, Surry, Watauga, Wilkes, Yadkin (336) 776-9800 (336) 776-9797 Fax INSTRUCTIONS FOR FORM: FTA 05-21 & SUPPORTING DOCUMENTATION Page 3 of 3 State of North Carolina Department of Environmental Quality Division of Water Resources Division of Water Resources Flow Tracking for Sewer Extension Applications (FTSE 10-18) .Mity Requesting Allocation: Charthouse Holdings, LLC 'ro'ect Name for which flow is being requested 8771 Cleveland Road PS & FM More than are FTSE may be requiredfor a single project if tlne owner of the WWTP Is not responsible for all punrp stations along the route of the proposed wastewater j1ay. I. Complete this section only if you are the owner of the wastewater treatment plant. a. WWTP Facility Name: I Central Johnston County WWTP b. WWTP Facility Permit #: I NCO030716 All o;vs are in MGD c. WWTP facility's permitted flow 9.5 d. Estimated obligated flow not yet tributary to the WWTP 2.087 e. WWTP facility's actual avg. flow 5.507 f. Total flow for this specific request 0.00025 g. Total actual and obligated flows to the facility 7.638 h. Percent of ermitted flow used 58 actual, 80 w/ a er71 II. Complete this section for each pump station you are responsible for along the route of this proposed wastewater flow. List pump stations located between the project connection point and the WWTP: A B C = B+C E= A-D Design Average Obligated, Total Pump Pump Daily Approx. Not Yet Current Station Station Firm Flow** Current Avg. Tributary Flow Plus (Name or Permit Capacity, * (Firm / pf), Daily Flow, Daily Flow, Obligated Available Number) No. MGD MGD MGD MGD Flow Capacity*** Josephine Rd. 28867mod 3.3840 1.3536 0.8271 0.4020 1.229 0.1245 Landfill EQ 20340 1.930 1.672 1.113 0.619 1.732 0.060 * The Firm Capacity (desien flow) of anv sumo station is defined as the maximum Dumped flow that can be achieved with the largest pump taken out of service. ** Design Average Daily Flow is the firm capacity of the pump station divided by a peaking factor (pf) not less than 2.5, per Section 2.02(A)(4)(c) of the Minimum Design Criteria. *** A Planning Assessment Addendum shall be attached for each pump station located between the project connection point and the WWTP where the Available Capacity is < 0. Downstream Facility Name Sewer : Cleveland Road Forcemain Downstream Permit Number: TBD Page l of 6 FTSE 10-18 III. Certification Statement: I I Chandra C. Farmer, PE I certify to the best of my knowledge that the addition of the volume of wastewater to be permitted in this project has been evaluated along the route to the receiving wastewater treatment facility and that the flow from this project is not anticipated to cause any capacity related sanitary sewer overflows or overburden any downstream pump station en route to the receiving treatment plant under normal circumstances, given the implementation of the planned improvements identified in the planning assessment where applicable. This analysis has been performed in accordance with local established policies and procedures using the best available data. This certification applies to those items listed above in Sections I and II plus all attached planning assessment addendums for which I am the responsible party. Signature of this form certifies that the receiving collection system or treatment works has adequate capacity to transport and treat the proposed new wastewater. VC(i c� l 111 �3 Page 2 of 6 FTSE 10-18 PLANK NG ASSESSMENT ADDENDUM (PAA) Submit a planning assessment addendum for each pump station listed in Section 11 where Available Capacity is 0. Pump Station (Name or Number): Given that: a. Tlie proportion and amount of Obligated. Not Yet Tributary Daily Flow C accounts for MGD of the Available Capacity (E) in Pump Station 37 and 0.619 Landfill E ; and that b. The rate of activation of this obligated, not yet tributary 0.2 MGD per year; and that c. A funded Capital Project that will provide the required Landfill Sewa a Pump Station FM is in de: planned completion in early 2024 ; and/or d. The followiniz aryvlies: is currently aonroximate or under construction with The Landfill EQ facilivy is being upgraded to 8.75 MGD in capacity. The station will be able to pump to both the CJRW WTF and the 210 WWTF. The station will have girt removal units and 5.1 MG of storage forequalization. The ma'ori of the flow will be received at the County new 210 WWTF when it is placed on-line in late 2024, Therefore: Given reasonably expected conditions and planning information, there is sufficient justification to allow this flow to be permitted, without a significant likelihood of over -allocating capacity in the system infrastructure. I understand that this does not relieve the collection system owner from complying with G.S. 143- 215.67(a) which prohibits the introduction of any waste in excess of the capacity of the waste disposal system. Page 3 of 6 FTSE 10-18 rED LINE ENGINEENING October 24, 2023 Mr. Michael Hall NC Department of Environmental Quality Division of Water Resources 3800 Barrett Drive Raleigh, North Carolina 27609 Re: 8771 Cleveland Road, Fast -Track Sewer System Extension Application Dear Mr. Hall, hope this letter finds you well. Enclosed is the Fast -Track Sewer System Extension Application for the existing Charthouse Commercial Building, located at 8771 Cleveland Road, Clayton, North Carolina. As discussed on the phone, this project was designed, permitted and constructed in 2016. In reviewing the adjacent project (8817 Cleveland Road), Johnston County determined that the project had not been permitted through NCDEQ. To correct this oversight, the County has requested that we permit the existing simplex grinder pump system and forcemain, after the fact. The existing 8771 Cleveland Road building is served by the a private simplex grinder pump station and approximately 120 If of 2" PVC forcemain, which connects to an existing 2" PVC public sewer forcemain at the southern right of way line of Cleveland Road (SR1010). Please find enclosed two copies of the application and all supporting documents. Thank you for your assistance with this FTA Sewer Extension Permit Application. If you have any questions, or need any further information, please feel free to contact me directly at (919) 606-4560 or email me at oarv.mccabeD-rlenc.com. Regards, Gary �/cCe, P.E. Red Line Engineering, P.C. 123 Raleigh Street 10 Fuquay-Varina, NC 27526 9 Office: (919)779-6851 0 www.rienc.com J Q)z CY 0 rrl ►1 0 Barber Shop 400 ft MMMM 9/7/23, 8:48 AM North Carolina Secretary of State Search Results • File an Annual Report/Amend an Annual Report • Upload a PDF Filing • Order a Document Online • Add Entity to My Email Notification List • View Filings • Print a Pre -Populated Annual Report form • Print an Amended a Annual Report form Limited Liability Company Legal Name Charthouse Holdings LLC Information Sosld: 1488556 Status: Current -Active O Date Formed: 12/29/2015 Citizenship: Domestic Annual Report Due Date: April 15th Currentgnnual Report Status: Registered Agent: Gower, Brian Dee, Addresses Mailing 8771-B Cleveland rd Clayton, NC 27520 Principal Office 8771-B Cleveland Rd Clayton, NC 27520 Company Officials Reg Office 8771-B Cleveland Rd Clayton, NC 27520 All LLCs are managed by their managers pursuant to N.C.G.S. 57D-3-20. Chief Executive Officer Brian D. Gower 33 Pale Stone Dr. Garner NC 27529 Reg Mailing 8771-B Cleveland Rd Clayton, NC 27520 https://www.sosnc.gov/onIine_services/search/Business_Registration_ResuIts 1/1 SOSID: 1488556 Date Filed: 12/29/2015 12:25:00 PM Elaine F. Marshall State of North Carolina North Carolina Secretary of State Department of the Secretary of State C2015 355 00778 Limited Liability Company ARTICLES OF ORGANIZATION Pursuant to §5713-2-20 of the General Statutes of North Carolina, the undersigned does hereby submit these Articles of Organization for the purpose of forming a limited liability company. 1. The name of the limited liability company is: Charthouse Holdings LLC (See Item I of the Instructions for appropriate entity designation) 2. The name and address of each person executing these articles of organization is as follows: (State whether each person is executing these articles of organization in the capacity of a member, organizer or both. Note: This document must be signed by all persons listed.) George N. Hamrick, Organizer 7048 Knightdale Blvd. Knightdale, NC 27545 3. The name of the initial registered agent is: Brian Gower 4. The street address and county of the initial registered agent office of the limited liability company is: Number and Street 33 Pale Stone Drive city Garner State: NC Zip Code: 27529 county: Johnston 5. The mailing address, if different from the street address, of the initial registered agent office is: Number and Street City State: NC Zip Code: County: 6. Principal office information: (Select either a or b.) a. ❑ The limited liability company has a principal office. The principal office telephone number: The street address and county of the principal office of the limited liability company is: Number and Street City, State: Zip Code: County: CORPORATIONS DIVISION P.O. Box 29622 RALEIGH, NC 27626-0622 (Revised January 2014) 1 (Form L-01) The mailing address, if different from the street address, of the principal office of the company is: Number and Street City State: Zip Code: County: b.❑ The limited liability company does not have a principal office. 7. Any other provisions which the limited liability company elects to include (e.g., the purpose of the entity) are attached. 8. (Optional): Please provide a business e-mail address: The Secretary of State's Office will e-mail the business automatically at the address provided above at no cost when a document is filed. The e-mail provided will not be viewable on the website. For more information on why this service is offered, please see the instructions for this document. 9. These articles will be effective upon filing, unless a future date is specified: This is the 17th day of December 20 15 Signature George N. Hamrick, Organizer Type or Print Name and Title The below space to be used if more than one organizer or member is listed in Item #2 above. Signature Signature Type and Print Name and Title Type and Print Name and Title Signature Signature Type and Print Name and Title Type and Print Name and Title NOTES: 1. Filing fee is $125. This document must be filed with the Secretary of State. CORPORATIONS DIVISION P.O. Box 29622 RALEIGH, NC 27626-0622 (Revised January 2014) 2 (Form L-01) DEPARTMENT OF PUBLIC UTILITIES PO BOX 2263 SMITHFIELD, NC 27577 (919) 989-5075 October 11, 2023 Mr. Gary McCabe, PE Red Line Engineering, P.C. Re: Sewer Collection Facilities to Serve Brian Gower Commercial Building (Private System) JC Project No: 23-023-P Approved Connection Dear Mr. McCabe: This letter is to confirm that Johnston County Public Utilities has reviewed the plans for the private sewer system to serve Brian Gower Commercial Building (JC Project No. 23-023 P). The proposed connection to the County's existing public sewer system has been approved with the following conditions: • Please provide a copy of the approved sewer permit (NCDEQ) for the private system to Johnston County Public Utilities prior to construction. • The private sewer system shall be vacuum tested (manholes) and air tested (sewer mains) in accordance with County standards prior to connection to the County's public system. • As -built drawings (sealed by the engineer) should be maintained by the property owner after the completion of construction. • The utility contractor must schedule a pre -construction conference with Johnston County Public Utilities prior to installation of the sewer collection facilities. Please find enclosed the "Flow Tracking for Sewer Extension Applications" executed by Johnston County for your submittal to NCDEQ with the permit for the private sewer system extension. Please contact me at (919) 209-8334 or rudy.wells@johnstonnc.com if you have any questions or need additional information. Sincerely, Rudy Wells, PE Civil Engineer