Loading...
HomeMy WebLinkAboutSW3221101_Supplement-EZ Form_20231024 INFILTRATION SYSTEM 1 Drainage area number 1 2 1 Minimum required treatment volume cu ft c GENERAL MDC FROM 02H.1050 3 Is the SCM sized to treat the SW from all surfaces at build-out? No 4 Is the SCM located away from contaminated soils? Yes 5 What are the side slopes of the SCM(H:V or enter"Vertical"for trenches)? 3:1 6 Does the SCM have retaining walls,gabion walls or other engineered side slopes? No 7 Are the inlets,outlets,and receiving stream protected from erosion 10- ear storm)? Yes 8 Is there an overflow or bypass for inflow volume in excess of the design volume? Yes 9 lWhat is the method for dewatering the SCM for maintenance? Pump(preferred) 10 If applicable,will the SCM be cleaned out after construction? Yes 11 Does the maintenance access comply with General MDC 8? Yes 12 Does the drainage easement comply with General MDC(9)? Yes 13 If the SCM is on a single family lot,does(will?)the plat comply with General MDC 10? N/A 14 Is there an O&M Agreement that complies with General MDC(11)? Yes 15 Is there an O&M Plan that complies with General MDC 12? Yes 16 IDoes the SCM follow the device specific MDC? Yes 17 lWas the SCM designed by an NC licensedprofessional? Te-sll INFILTRATION SYSTEM MDC FROM 02H.1051 18 Proposed slope of the subgrade surface(%) 6% 19 jAre terraces or baffles provided? No 20 IType ofpretreatment: I Forebay Soils Data 21 Was the soil investigated in the footprint and at the elevation of the infiltrations stem? Yes 22 SHWT elevation(fmsl) 651.80 23 Depth to SHWT per soils report in 38.00 24 Ground elevation at boring in soils report(fmsl) 655.00 25 Is a detailed hydrogeologic study attached if the separation is between 1 and 2 feet? N/A 26 ISoil infiltration rate(in/hr) 0.14 27 1 Factor of safety FS 2 is recommended): 2.00 Elevations 29 Bottom elevation fmsl 654 ft 30 IStorage elevation(fmsl) 654.36 ft 31 1 Bypass elevation fmsl 654.36 For Basins Only 32 113ottom surface area(ft) 24900 ft 33 IStorage elevation surface area(ft) 27125.ft For Trenches Only 34 Length(ft) 35 Width ft 36 Perforated pipe diameter,if applicable(inches) 37 Number of laterals 38 Total length of perforated piping 39 Stone type,if applicable 40 IStone porosity(%) 41 Is stone free of fines? 42 11sthe stone wrapped in geotextile fabric? 43 1 Has at least one inspection port beenprovided? Volumes/Drawdown 44 IDesign volume of SCM cu ft 10092 cf 45 ITime to draw down hours rs ADDITIONAL INFORMATION 46 Please use this space to provide any additional information about the infiltration system(s): Forebay excluded from infiltration basin surface area. Total infiltration surface area =24,900 sf,Forebay area= 2,160 sf Desi n Volume=Basin Volume @ Elevation 654.36' low level drain invert Infiltration 1 12:30 PM 10/24/2023