Loading...
HomeMy WebLinkAboutWV0700173_More Information (Received)_20231018 (4)PAGE 4 of 4 —Traub Variance Request The proposed geothermal aqueous closed loop system for the address listed on page 1 is in need of a distance requirement variance. The location of the proposed residential structures and the onsite operational & reserve drain fields are impeding the location of the geothermal closed loop field to be located within the residential and septic system setback distance respectively. We are proposing to locate the vertical bores towards the center of the property. In this manner we can obtain maximum safety distance from the septic system and achieve a very high degree of human health and environmental protection. The vertical bores will be grouted from top to bottom with high quality, low permeability grout using the tremie method to assure the bore hole will be a solid plug of environmental protection. The bore holes we construct will be the safest points of ground water intrusion on the property when compared to the native geology. We will construct triangulated borehole construction maps for each hole for permanent locating and install metal detection tape in all of the horizontal connecting trenches to facilitate easy bore hole locating if ever needed for any reason. Due to the fact a geothermal vertical closed loop is constructed in the same manner as an abandoned well and does not move water, does not contain well screens or casing and is not an actual water well, future service will not be required.