HomeMy WebLinkAboutNC0025348_Compliance Evaluation Inspection_20231019 ROY COOPER Governor �3T - � , ELIZABETH S.BISER ^ten Secretary RICHARD E.ROGERS,JR. NORTH CAROLINA Director Environmental Quality October 19, 2023 Jordan Hughes, Director of Water Resources City of New Bern PO Box 1129 New Bern, NC 28563-1129 SUBJECT: Compliance Inspection Report New Bern WWTP NPDES WW Permit No. NCO025348 Craven County Dear Permittee: The North Carolina Division of Water Resources conducted an inspection of the New Bern WWTP on 9/19/2023. This inspection was conducted to verify that the facility is operating in compliance with the conditions and limitations specified in NPDES WW Permit No. NC0025348. The findings and comments noted during this inspection are provided in the enclosed copy of the inspection report entitled "Compliance Inspection Report". There were no significant issues or findings noted during the inspection and therefore, a response to this inspection report is not required. If you should have any questions, please do not hesitate to contact me at the Water Quality Regional Operations Section, in the Washington Regional Office at 252-946-6481 or via email at scott.vinson@deq.nc.gov. Sincerely, --- Scott Vinson, Environmental Engineer Water Quality Regional Operations Section Washington Regional Office Division of Water Resources, NCDEQ ATTACHMENTS —Water Compliance Inspection Report-09192023, NCO025348 Cc: Tony Hawkins, ORC NCDWR Central Files, Laserfiche v(i&N ��a'�J Nwth C.rWllw Dclartmrnl ul F.M nmcnld t]uullyl nlrixY.,ut W.I.�ca `�` \'ash:np:an Regbrol UfRa I931\4shtrgtm Squu<Mall Wuhlfptat NortA CaroArx 7/889 752946M81 United States Environmental Protection Agency Form Approved. EPA Washington,D.C.20460 OMB No.2040-0057 Water Compliance Inspection Report Approval expires 8-31-98 Section A: National Data System Coding (i.e., PCS) Transaction Code NPDES yr/molday Inspection Type Inspector Fac Type 1 Iti I 2 15 I 3 1 NCO025348 I11 12 23/09/19 j 17 18I C I 19 I c I 201 I 21L1 1 1 1 1 1 1 1 1 11 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 11 1 1 1 1 1 f6 Inspection Work Days Facility Self-Monitoring Evaluation Rating B1 QA ----------------------Reserved------------------- 671 70I I 711 I 72 73�74 71 1 1 1 1 1 1 180 LJ ty Section B: Facility Data l-J Name and Location of Facility Inspected(For Industrial Users discharging to POTW,also include Entry Time/Date Permit Effective Date POTW name and NPDES permit Number) 09:45AM 23/09/19 23l01l01 New Bern WWTP 307 Glenburnie Dr Exit Time/Date Permit Expiration Date New Bern NC 28560 12:15PM 23/09/19 27/06/30 Name(s)of Onsite Representative(s)Mtles(s)/Phone and Fax Number(s) Other Facility Data 111 Tony Randall Hawkins/ORC/252-639-7556/ Name,Address of Responsible Official/Title/Phone and Fax Number Contacted Walter B Hartman,PO Box 1129 New Bern NC 285631129/City Manager/252-636-4014/2526361848 No Section C:Areas Evaluated During Inspection(Check only those areas evaluated) Permit 0 Flow Measurement Operations&Maintenar Records/Reports Self-Monitoring Progran E Sludge Handling Dispo: Facility Site Review Effluent/Receiving Wate Laboratory Section D: Summary of Finding/Comments(Attach additional sheets of narrative and checklists as necessary) (See attachment summary) Name(s)and Signature(s)of Inspector(s) Agency/Office/Phone and Fax Numbers Date ScottA mson DWRNVARO WQ/919-791-4252/ Signature of Management Q A Reviewer Agency/Office/Phone and Fax Numbers Date Raw TAIF." DWR/WQROS/WARD 252-948-3921 10/20/2023 EPA Form 3560-3(Rev 9-94)Previous editions are obsolete. Page# 1 NPDES yrlmo/day Inspection Type (Cont.) 1 31 NG0025348 I11 1 23/09/19 117 18 I r'E Section D: Summary of Finding/Comments (Attach additional sheets of narrative and checklists as necessary) On September 19, 2023 Scott Vinson with the Division of Water Resources from the Washington Regional Offie conducted a compliance evaluation of New Bern WWTP. Plant ORC's Tony Hawkins and Art Hough and Head Lab chemsist Cheryl King were present during the inspection and were helpful by answering all questions and by providing access to the entire site. Thanks and appreciation goes out these staff members for their assistance. Records Review: July 2022 and February 2023 eDMRs and corresponding lab data was throughly reviewed and compared to lab data and field bench sheets with no descrepacies. The 2021 &2022 annual reports were available as well as the ORC Visitation & Operation and Maintenance logs. All were complete and met records requirements. All other required documents such as the Flow meter calibrations, lab certifications, etc. were made available for review. Lab chemist, Ms. King, was available to assist with providing lab records. Lab chemist, Ms. King, was available to assist with providing lab records. A contract lab is used for metals whie the on-site New Bern WWTP lab performs the majority of the parameter analysis. Lord & Company provides the flow meter calibrations. Influent Flow meter calibrated on 8/22/2023 at 99.96% Accuracy by Dan Griffin. Effluent Flow meter calibrated on 8/22/2023 at 99,96%Accuracy by Dan Griffin. Efffluent to Quarry flow meter calibrated on 8/22/2023 at 99,97%Accuracy by Thomas Jones. Efluent sampler is flow proportional and samples are 450mL per sample. The thermometer within the sampler read 4 degrees Celsius. Influent sampler is flow proportional and samples obtained are 450mL per sample. The thermometer within the sampler read 5 degrees Celsius. The collected debris, sand, grit, etc. is hauled to a lined landfill on Mondays, Wednesdays and Fridays each week. Both clarifiers#1 &#2 were in good working condition, free of excessive algae and grease. There was very minor pin floc present. ORC, Tony Hawkins performed a sludge measurement (w/sludge judge) on both Clarfiers resulting in: Clarifier#1 = 3.00 feet of sludge Blanket Clarifier#2 = 1.50 feet of sludge Blanket The tertiary filters are typically backwashed twice a day around 11:OOam & 3:00pm. The high-water alarms for the filter functions thrugh the plant's SCADA system. At the time of this inspections the sludge press and storage areas were temporarily shut down for maintenance. The whole shelter area was being painted. The solids were temporarily being stored in the digesters until painting is finished. Pleanty of room available. Site looks clean and well kept. Grade A solids are mainly haued daily to the City's landfill for topping material. Generators are tested weekly under load and the facility has a monithly maintenance checklist that it uses to maintain them. The fuel tanks for the generators were around 70%+ full. Page# 2 Permit: NCO025348 Owner-Facility: New Bern MWID Inspection Rate: 0 911 91202 3 Inspection Type: Compliance Evaluation Permit Yes No NA NE (If the present permit expires in 6 months or less). Has the permittee submitted a new ■ ❑ ❑ ❑ application? Is the facility as described in the permit? ■ ❑ ❑ ❑ #Are there any special conditions for the permit? ■ ❑ ❑ ❑ Is access to the plant site restricted to the general public? ■ ❑ ❑ ❑ Is the inspector granted access to all areas for inspection? ■ ❑ ❑ ❑ Comment: Operations & Maintenance Yes No NA NE Is the plant generally clean with acceptable housekeeping? ■ ❑ ❑ ❑ Does the facility analyze process control parameters, for ex: MLSS, MCRT, Settleable ■ ❑ ❑ ❑ Solids, pH, DO, Sludge Judge, and other that are applicable? Comment: Record Keeping Yes No NA NE Are records kept and maintained as required by the permit? ■ ❑ ❑ ❑ Is all required information readily available, complete and current? ■ ❑ ❑ ❑ Are all records maintained for 3 years (lab. reg. required 5 years)? ■ ❑ ❑ ❑ Are analytical results consistent with data reported on DMRs? ■ ❑ ❑ ❑ Is the chain-of-custody complete? ■ ❑ ❑ ❑ Dates, times and location of sampling ■ Name of individual performing the sampling ■ Results of analysis and calibration ■ Dates of analysis ■ Name of person performing analyses ■ Transported COCs ■ Are DMRs complete: do they include all permit parameters? ■ ❑ ❑ ❑ Has the facility submitted its annual compliance report to users and DWQ? ■ ❑ ❑ ❑ (if the facility is = or > 5 MGD permitted flow) Do they operate 24/7 with a certified ■ ❑ ❑ ❑ operator on each shift? Is the ORC visitation log available and current? ■ ❑ ❑ ❑ Is the ORC certified at grade equal to or higher than the facility classification? ■ ❑ ❑ ❑ Is the backup operator certified at one grade less or greater than the facility ■ ❑ ❑ ❑ classification? Page# 3 Permit: NCO025348 Owner-Facility: New Bern VVVvTP Inspection Date: 0911912023 Inspection Typo: Compliance Evaluation Record Keeping Yes No NA NE Is a copy of the current NPDES permit available on site? ■ ❑ ❑ ❑ Facility has copy of previous year's Annual Report on file for review? ■ ❑ ❑ ❑ Comment; July 2022 and February 2023 eDMRs and corresponding lab data was throughly reviewed and compared_to lab data and field bench sheets with no descrepacies. The 2021 & 2022 annual_reports were available as well as the ORC Visitation &Operation and Maintenance logs. All were complete and met records requirements. All other required documents such as the Flow meter calibrations, lab certifications, etc. were made available for review. Lab chemist, Ms. Kinq, was available to assist with providing lab records. Laboratory Yes No NA NE Are field parameters performed by certified personnel or laboratory? M ❑ ❑ ❑ Are all other parameters(excluding field parameters) performed by a certified lab? M ❑ ❑ ❑ # Is the facility using a contract lab? N ❑ ❑ ❑ # Is proper temperature set for sample storage (kept at less than or equal to 6.0 ■ ❑ ❑ ❑ degrees Celsius)? Incubator(Fecal Coliform) set to 44.5 degrees Celsius+/- 0.2 degrees? ■ ❑ ❑ ❑ Incubator(BOD) set to 20.0 degrees Celsius +/- 1.0 degrees? 0 ❑ ❑ ❑ Comment: Lab chemist, Ms. King, was available to assist with providing lab records. A contract lab is used for metals whie the on-site New Bern WWTP lab performs the maiority of the parameter analysis. Flow Measurement - Influent Yes No NA NE # Is flow meter used for reporting? ❑ ■ ❑ ❑ Is flow meter calibrated annually? N ❑ ❑ ❑ Is the flow meter operational? M ❑ ❑ ❑ (If units are separated) Does the chart recorder match the flow meter? ❑ ❑ 0 ❑ Comment: Lord & Company provides the flow meter calibrations. Influent Flow meter calibrated on 8/22/2023 at 99,96%Accuracy by Dan Griffin. Influent sampler is flow proportional and samples obtained are 450ml-per sample. The thermometer within the sampler read 5 degrees Celsius. Pump Station - Influent Yes No NA NE Is the pump wet well free of bypass lines or structures? ■ ❑ ❑ ❑ Is the wet well free of excessive grease? 0 ❑ ❑ ❑ Are all pumps present? ■ ❑ ❑ ❑ Are all pumps operable? ■ ❑ ❑ ❑ Are Float controls operable? ❑ ❑ ■ ❑ Page# 4 Permit: NCO025348 Owner-Facility: New Bern VJWTP Inspection Date: 09/1 91202 3 Inspection Type: Compliance Evaluation Pump Station - Influent Yes No NA NE Is SCADA telemetry available and operational? ■ ❑ ❑ ❑ Is audible and visual alarm available and operational? ❑ ❑ ❑ ■ Comment: Bar Screens Yes No NA NE Type of bar screen a.Manual ■ b.Mechanical ■ Are the bars adequately screening debris? ■ ❑ ❑ ❑ Is the screen free of excessive debris? ■ ❑ ❑ ❑ Is disposal of screening in compliance? ■ ❑ ❑ ❑ Is the unit in good condition? ■ ❑ ❑ ❑ Comment: The collected debris, sand, grit, etc, is hauled to a lined landfill on Mondays. Wednesdays and Fridays each week. Grit Removal Yes No NA NE Type of grit removal a.Manual ■ b.Mechanical ■ Is the grit free of excessive organic matter? ■ ❑ ❑ ❑ Is the grit free of excessive odor? ■ ❑ ❑ ❑ # Is disposal of grit in compliance? ■ ❑ ❑ ❑ Comment: The collected debris, sand, grit, etc. is hauled to a lined landfill on Mondays, Wednesdays and Fridays each week. Oxidation Ditches Yes No NA NE Are the aerators operational? ■ ❑ ❑ ❑ Are the aerators free of excessive solids build up? ■ ❑ ❑ ❑ # Is the foam the proper color for the treatment process? ■ ❑ ❑ ❑ Does the foam cover less than 25% of the basin's surface? ■ ❑ ❑ ❑ Is the DO level acceptable? ■ ❑ ❑ ❑ Are settleometer results acceptable (> 30 minutes)? ❑ ❑ ❑ ■ Is the DO level acceptable?(1.0 to 3.0 mg/I) ■ ❑ ❑ ❑ Are settelometer results acceptable?(400 to 800 ml/l in 30 minutes) ❑ ❑ ❑ ■ Page# 5 Permit: NCO025348 Owner-Facility: New Bern VVVVTP Inspection Date: 09/19/2023 Inspection Type: Compliance Evaluation Oxidation Ditches Yes No NA NE Comment: Secondary Clarifier Yes No NA NE Is the clarifier free of black and odorous wastewater? 0 ❑ ❑ ❑ Is the site free of excessive buildup of solids in center well of circular clarifier? E ❑ ❑ ❑ Are weirs level? 0 ❑ ❑ ❑ Is the site free of weir blockage? 0 ❑ ❑ ❑ Is the site free of evidence of short-circuiting? E ❑ ❑ ❑ Is scum removal adequate? 0 ❑ ❑ ❑ Is the site free of excessive floating sludge? 0 ❑ ❑ ❑ Is the drive unit operational? ■ ❑ ❑ ❑ Is the return rate acceptable (low turbulence)? ■ ❑ ❑ ❑ Is the overflow clear of excessive solids/pin floc? ■ ❑ ❑ ❑ Is the sludge blanket level acceptable? (Approximately Y4 of the sidewall depth) 0 ❑ ❑ ❑ Comment: Both clarifiers#1 &#2 were in good working condition free of excessive algae and grease. There was very minor pin floc present. ORC, Tony Hawkins performed a sludge measurement w/sludge 'ud e on both Clarfiers resulting in: Clarifier#1 = 3.00 feet of sludge Blanket Clarifier_#2_= 1.50 feet_of_sludge Blanket Pumps-RAS-WAS Yes No NA NE Are pumps in place? ■ ❑ ❑ ❑ Are pumps operational? ■ ❑ ❑ ❑ Are there adequate spare parts and supplies on site? M ❑ ❑ ❑ Comment: Sand Filters (Low rate) Yes No NA NE (If pumps are used) Is an audible and visible alarm Present and operational? 0 ❑ ❑ ❑ Is the distribution box level and watertight? 0 ❑ ❑ ❑ Is sand filter free of ponding? ❑ ❑ 0 ❑ Is the sand filter effluent re-circulated at a valid ratio? ❑ ❑ ■ ❑ # Is the sand filter surface free of algae or excessive vegetation? 0 ❑ ❑ ❑ # Is the sand filter effluent re-circulated at a valid ratio? (Approximately 3 to 1) ❑ ❑ 0 ❑ Comment: The tertiary filters are typically backwashed twice a day around 11:00am & 3:00pm. The high-water alarms for the filter functions thrugh the plant's SCADA system. Page# 6 Permit: NCO025348 Owner.Facility: New Bern VdWTP Inspection Date: 0 911 9/2 0 2 3 Inspection Type: Compliance Evaluation Disinfection-Liquid Yes No NA NE Is there adequate reserve supply of disinfectant? ■ ❑ ❑ ❑ (Sodium Hypochlorite) Is pump feed system operational? M ❑ ❑ ❑ Is bulk storage tank containment area adequate? (free of leaks/open drains) M ❑ ❑ ❑ Is the level of chlorine residual acceptable? M ❑ ❑ ❑ Is the contact chamber free of growth, or sludge buildup? M ❑ ❑ ❑ Is there chlorine residual prior to de-chlorination? ❑ ❑ ❑ Comment: De-chlorination Yes No NA NE Type of system ? Liquid Is the feed ratio proportional to chlorine amount(1 to 1)? ■ ❑ ❑ ❑ Is storage appropriate for cylinders? ■ ❑ ❑ ❑ # Is de-chlorination substance stored away from chlorine containers? ■ ❑ ❑ ❑ Comment: Are the tablets the proper size and type? ❑ ❑ ■ ❑ Are tablet de-chlorinators operational? ❑ ❑ ■ ❑ Number of tubes in use? Comment: Flow Measurement - Effluent Yes No NA NE # Is flow meter used for reporting? ■ ❑ ❑ ❑ Is flow meter calibrated annually? ■ ❑ ❑ ❑ Is the flow meter operational? 0 ❑ ❑ ❑ (If units are separated) Does the chart recorder match the flow meter? ❑ ❑ ■ ❑ Comment: Lord & Company provides the flow meter calibrations. Effluent Flow meter calibrated on 8/22/2023 at 99.96%Accuracy by Dan Griffin. Efffluent to Quarry flow meter calibrated on 8/22/2023 at 99.97%Accuracy by Thomas Jones. Efluent sampler is flow proportional and samples are 450mL per sample. The thermometer within the sampler read 4 degrees Celsius. Aerobic Digester Yes No NA NE Is the capacity adequate? 0 ❑ ❑ ❑ Is the mixing adequate? ■ ❑ ❑ ❑ Is the site free of excessive foaming in the tank? M ❑ ❑ ❑ Page# 7 Permit: NCO025348 Owner-Facility: New 8ern WWfP Inspection Date: 0911912023 Inspection Type: Compliance Evaluation Aerobic Digester Yes No NA NE # Is the odor acceptable? 0 ❑ ❑ ❑ # Is tankage available for properly waste sludge? M ❑ ❑ ❑ Comment: Solids Handling Equipment Yes No NA NE Is the equipment operational? 0 ❑ ❑ ❑ Is the chemical feed equipment operational? ■ ❑ ❑ ❑ Is storage adequate? M ❑ ❑ ❑ Is the site free of high level of solids in filtrate from filter presses or vacuum filters? ■ ❑ ❑ ❑ Is the site free of sludge buildup on belts and/or rollers of filter press? ❑ ❑ ❑ ■ Is the site free of excessive moisture in belt filter press sludge cake? ❑ ❑ ❑ ■ The facility has an approved sludge management plan? ■ ❑ ❑ ❑ Comment: At the time of this inspections the sludge press and storage areas were temporarily shut down for maintenance. The whole shelter area was being painted. The solids were temporarily being stored in the digesters until painting is finished. Pleanty of room available. Site looks clean and well kept. Grade A solids are mainly haued daily to the City's landfill for topping material. Standby Power Yes No NA NE Is automatically activated standby power available? ■ ❑ ❑ ❑ Is the generator tested by interrupting primary power source? ■ ❑ ❑ ❑ Is the generator tested under load? ■ ❑ ❑ ❑ Was generator tested & operational during the inspection? ❑ ❑ ❑ ■ Do the generator(s) have adequate capacity to operate the entire wastewater site? 0 ❑ ❑ ❑ Is there an emergency agreement with a fuel vendor for extended run on back-up ■ ❑ ❑ ❑ power? Is the generator fuel level monitored? ■ ❑ ❑ ❑ Comment: Generators are tested weekly under load and the facility has a monithly maintenance checklist that it uses to maintain them. The fuel tanks for the generators were around 70%+ full. Page# 8