Loading...
HomeMy WebLinkAboutNC0073539_Draft_FactSheet_20231020 Fact Sheet for Permit Renewal Oct 2023 - NPDES Permit NC0073539 - Page 1 NCDEQ / DWR / NPDES EXPEDITED FACT SHEET - NPDES PERMIT RENEWAL NPDES Permit NC0073539 Caroline Robinson / Compliance & Expedited Permitting Unit / caroline.robinson@deq.nc.gov / Oct 2023 FACILITY INFORMATION Applicant/Facility Name Aqua North Carolina, Inc. (Joe Pearce and Robyn Lambeth) Willowbrook Subdivision WWTP Applicant Address 202 MacKenan Court, Cary, NC 27511 Facility Physical Address/Mailing Address 12309 Ramah Creek Court, Huntersville, NC 28078 Permitted Flow (MGD) 0.048 MGD Type of Waste 100% Domestic, < 1 MGD Facility Class WW-2 County Mecklenburg Permit Status Renewal Regional Office MRO STREAM CHARACTERISTICS Receiving Stream Ramah Creek Stream Classification C Stream Segment 13-17-4-4 Outfall Lat. 35° 26' 38" N 7Q10 - Summer (cfs) 0.075 Outfall Long. 80° 49' 09" W 7Q10 - Winter (cfs) 0.15 Drainage basin Yadkin-Pee Dee River Basin 30Q2 (cfs) 0.15 Subbasin 03-07-11 Average Flow (cfs) 1.5 HUC 030401050101 IWC (%) 49.80% (summer) / 33.16% (winter) 303(d) List No BASIC INFO FOR EXPEDITED PERMIT RENEWAL Does permit need Daily Max NH3 limits? Already present in permit; however, revised ammonia limits, based on the IWC calculations and 2016 NH3 guidance document, will take effect on 1/1/2028. These revised limits include, a monthly summer limit of 2 mg/L, a daily summer limit of 10 mg/L, a monthly winter limit of 5 mg/L, and a daily winter limit of 25 mg/L. Does permit need TRC limits/footnote? No – Already present in permit. Does permit have toxicity testing? No – not a complex wastestream Does permit have any Special Conditions? No Does permit have instream monitoring? Yes – U & D for Temperature and Dissolved Oxygen New expiration date: Nov 30, 2028 FACILITY SUMMARY Aqua North Carolina, Inc. operates a wastewater treatment plant for an estimated 249 residents. Willowbrook Subdivision WWTP is a minor 100% domestic facility (flow < 1 MGD) with a design capacity and permitted wastewater discharge of 0.048 MGD. The original NPDES permit for this facility was issued in September 1988. This facility utilizes the following treatment components: ⬧ Bar screen ⬧ Aeration basin ⬧ Clarifier ⬧ Tablet chlorination w/contact tank Fact Sheet for Permit Renewal Oct 2023 - NPDES Permit NC0073539 - Page 2 ⬧ Dechlorination ⬧ Aerated sludge holding tank ⬧ Continuous flow measurement ⬧ Composite sampler ⬧ Auxillary power back up w/ automatic transfer switch ⬧ Aerated flow equalization tank RENEWAL SUMMARY This renewal contains the following changes: • Updated the Supplement to Permit Cover Sheet by adding the aerated flow equalization tank to the treatment components section. • Added revised ammonia limits, based on the IWC calculations and 2016 NH3 guidance document, that will take effect on 1/1/2028. These revised limits include, a monthly summer limit of 2 mg/L, a daily summer limit of 10 mg/L, a monthly winter limit of 5 mg/L, and a daily winter limit of 25 mg/L. This change is shown in the table in Part I. A. (1). • Updated eDMR language for electronic data submission in Part I. A. (2) COMPLIANCE HISTORY Willowbrook Subdivision WWTP has had no enforcements since July 2016. The facility has had no NOVs or NODs since the last permit was issued in February 2019. Most recent inspection (November 2021) showed the facility to be in compliance.