Loading...
HomeMy WebLinkAbout580033_Inspection_20000302I O Division of Water Quality I Division of Soil and Water Conservation O Other Agency (Type of Visit O Compliance Inspection O Operation Review OO Lagoon Evaluation I Reason for Visit O Routine O Complaint O Follow up O Emergency Notification O Other ❑ Denied Access Facility Number SS 33 E3 Permitted 1] Certified 0 Conditionally Certified E Registered Date of Visit 3 z-z000 Not Operational Q Below Threshold 1 Date Last Operated or Above Threshold: 1J...95 ............ Farm Name: Laois....Wyf>.oe.l.aaan....... _...................... _....... _._........................... _........... County: Max:tm................................... _........ _ .W.e1.i.Q........ OwnerName: Laois ....................................... WWixe ........................................................ Phone No: 2,42-.7.9.2-45,37............................. _........................... Facility Contact: Title: Phone No: Mailing Address: 1f47.W=.Rd...................................................................................... W..illiatttstan.xC................................................... 27.892 ............. Onsite Representative: Louis..Wy=........................ _.......... _................................... ..... Integrator: ..................... .._.................... _ ... _........................... Location of Farm: 2.xuiles..Satxtlt.af.> xeGetts.au.YY9txtfe.Rx1 SR.11�i.I!IArth.side.u£the.r.Qad................................................................................................................... N Swine []Poultry ❑ Cattle ❑ Horse Design Current Swine Capacity Population ❑ Wean to Feeder ❑ Feeder to Finish ❑ Farrow to Wean N Farrow to Feeder 106 0 ❑ Farrow to Finish ❑ Gilts ❑ Boars Design Current Design Current Poultry Capacity Population Cattle Capacity Population ❑ Layer I I ❑Dairy ❑ Nan -Layer I 1 10 Non -Dairy ❑ Other Total Design Capacity 106 Total SSLW 55,332 Number of Lagoons Holding Ponds / Solid Traps E:::� I Discharges & Stream Impacts 1. Is any discharge observed from any part of the operation? Discharge originated at: ❑ Lagoon ❑ Spray Field ❑ Other a. If discharge is observed, was the conveyance man-made? b. If discharge is observed, did it reach Water of the State? (If yes, notify DWQ) c. If discharge is observed, what is the estimated flow in gal/min? 2. Is there evidence of past discharge from any part of the operation? 3. Is storage capacity (freeboard plus storm storage) less than adequate? ❑ Spillway Waste Collection & Treatment Please see attached Lagoon Field Data Sheets Reviewer/Inspector Name Martin Mclawhorn Reviewer/Inspector Signature: Date: ❑ Yes N No ❑ Yes ❑ No ❑ Yes ❑ No ❑ Yes N No ❑ Yes N No Printed on: 5/12/2000 Facility Number 58 — 33 Lagoon Number A. Lagoon Identifier pri.many.................................................... ' O Active (* Inactive Latitude 135 49 07 Waste Last Added,1..9-a5........................................... Longitude 77 09 41 Determined by: ® Owner ❑ Estimated Surface Area (acres): Q,Q......................... Embankment Height (feet): Q,,Q........................... By GPS or Map? "S ❑ Map GPS file number: IL030215A Distance to Stream: #<250feet O 250 feet - 1000 feet O >1000 feet By measurement or Map? ® Field Measurement ❑ Map Down gradient well within 250 feet? O Yes* No Intervening Stream? O Yes# No Distance to WS or HQW (miles): O < 5 O 5 - 10O > 10 Overtopping from Outside Waters? O Yes # No O Unknown Spillway O Yes O No Adequate Marker O Yes O No Freeboard & Storm Storage Requirement (inches): inspection date 3-2-2000 appearance of O Sludge Near Surface lagoon liquid 0 Lagoon Liquid Dark, Discolored O Lagoon Liquid Clear O Lagoon Empty Freeboard (inches): 20.0 embankment condition O Poorly Built, Large Trees, Erosion, Burrows, Slumping, Seepage, Tile Drains, Etc. p Construction Specification Unknown But Dam Appears in Good Condition O Constructed and Maintained to Current NRCS Standards outside drainage# Poorly Maintained Diversions or Large Drainage Area not Addressed in Design O Has Drainage Area Which is Addressed in Lagoon Design O No Drainage Area or Diversions Well Maintained liner status O High Potential for Leaking, No Liner, Sandy Soil, Rock Outcrops Present, Etc. O No Liner, Soil Appears to Have Low Permeability O Meets NRCS Liner Requirements cation equipment fail to make contact and/or Sprayfield O Yes # No O Unknown with representative O Yes O@ No unavailable comments Horses are allowed to drink from lagoon causing errosion on inner lagon walls. Mr. Wynn stated he would fence animals off of lagoon.