Loading...
HomeMy WebLinkAboutWQ0033589_Notice of Violation_20231019ROY COOPER Governor ELIZABETH S. BISER Secretary RICHARD E. ROGERS, JR. Director Certified Mail 7022 1670 0000 9974 8228 Return Receipt Reauested NORTH CAROLINA Environmental Quality October 19, 2023 Michael P. Remige, General Manager North Carolina Department of Natural and Cultural Resources P.O. Box 1445 Nags Head, NC 27959 SUBJECT: NOTICE OF VIOLATION Tracking Number: NOV-2023-LM-0078 Permit No. WQ0033589 Jennette's Pier WWTP Dare County Dear Mr. Remige: A review of the August 2023 Non -Discharge Monitoring Report (NDMR) for the subject facility revealed the violation(s) indicated below: Limit Exceedance Violation(s): Sample Limit Reported Location Parameter Date Value Value Type of Violation 001 BOD, 5-Day (20 Deg. C) 8/9/2023 15 28 Daily Maximum Exceeded (00310) 001 BOD, 5-Day (20 Deg. C) 8/14/2023 15 16 Daily Maximum Exceeded (00310) 001 BOD, 5-Day (20 Deg. C) 8/22/2023 15 60 Daily Maximum Exceeded (00310) 001 Nitrogen, Ammonia Total (as 8/22/2023 6 12.6 Daily Maximum Exceeded N) (00610) 001 BOD, 5-Day (20 Deg. C) 8/31/2023 10 20.8 Monthly Average Exceeded (00310) 001 Nitrogen, Total (as N) (00600) 8/31/2023 7 12.84 Monthly Average Exceeded North Carolina Department of Environmental Quality I Division of Water Resources D_EQ� Washington Regional Office 1 943 Washington Square Mall I Washington. North Carolina 27889 252.946.6483 Monitorina Violationlsl: Sample Monitoring Location Parameter Date Frequency Type of Violation 001 Turbidity, HCH Turbidimiter (00076) 8/5/2023 Continuous Frequency Violation 001 Turbidity, HCH Turbidimiter (00076) 8/6/2023 Continuous Frequency Violation 001 Turbidity, HCH Turbidimiter (00076) 8/12/2023 Continuous Frequency Violation 001 Turbidity, HCH Turbidimiter (00076) 8/13/2023 Continuous Frequency Violation 001 Turbidity, HCH Turbidimiter (00076) 8/19/2023 Continuous Frequency Violation 001 Turbidity, HCH Turbidimiter (00076) 8/20/2023 Continuous Frequency Violation 001 Turbidity, HCH Turbidimiter (00076) 8/26/2023 Continuous Frequency Violation 001 Turbidity, HCH Turbidimiter (00076) 8/27/2023 Continuous Frequency Violation Remedial actions, if not already implemented, should be taken to correct any noted problems. The Division of Water Resources may pursue enforcement actions for this and any additional violations. If the violations are of a continuing nature, not related to operation and/or maintenance problems, and you anticipate remedial construction activities, then you may wish to consider applying for a Special Order by Consent (SOC). If you have any questions regarding this Notice or need additional information, you may contact Robert Tankard at (252) 948-3921 or Randy Sipe at (252) 948-3849. Sincerely, ROW TOW." Robert Tankard, Assistant Regional Supervisor Water Quality Regional Operations Section Washington Regional Office Division of Water Resources, NCDEQ Cc: Dave Robertson (ORC) — Atlantic OBX (electronic copy) Laserfiche North Carolina Department of Environmental Quality I Division of Water Resources D_E Q Washington Regional Office 1 943 Washington Square Mall I Washington. North Carolina 27889 252.946.6483