Loading...
HomeMy WebLinkAboutGW1--06370_Well Construction - GW1_20230927 WELL CONSTRUCTION RECORD(GW-1) For Internal Use Only: 1.Well Contractor Information: Chris C Russell 14.WATER ZONES Well Contractor Name FROM TO DESCRIPTION 3254 A 100 ft 1025 ft• ft. ft. NC Well Contractor Certification Number 15.OUTER CASING(for multi-cased wells)OR LINER(if applicable) Russell Well Drilling, Inc. FROM TO DIAMETER THICKNESS MATERIAL Company Name 0 ft. 59 ft. 6.25 , 'in' SDR21 PVC WELL 12-2022-185887 16.INNER CASING OR TUBING(geothermal closed-loop) 2.Well Construction Permit#: FROM TO DIAMETER , THICKNESS MATERIAL List all applicable well construction permits(i.e.UIC,County,State.Variance,etc.) ft. ft. in. 3.Well Use(check well use): ft. ft. in. Water Supply Well: 17.SCREEN FROM TO DIAMETER SLOT SIZE THICKNESS MATERIAL ❑Agricultural ❑Municipal/Public ft ft. in. ❑Geothermal(Heating/Cooling Supply) I1Residential Water Supply(single) ft. ft. in. ❑Industrial/Commercial ❑Residential Water Supply(shared) 18.GROUT ❑Irrigation ❑Wells>100,000 GPD FROM TO MATERIAL 4 EMPLACEMENT METHOD&AMOUNT Non-Water Supply Well: 0 ft. 20 ft. Grout Poured ❑Monitoring ❑Recovery ft. ft. Injection Well: ft. ft. ❑Aquifer Recharge ❑Groundwater Remediation 19.SAND/GRAVEL PACK(if applicable) ❑Aquifer Storage and Recovery ❑Salinity Barrier FROM TO MATERIAL , EMPLACEMENT METHOD ❑Aquifer Test 0 Stormwater Drainage ft. ft ❑Experimental Technology ❑Subsidence Control ft. ft. ❑Geothermal(Closed Loop) ❑Tracer 20.DRILLING LOG(attach additional sheets if necessary) FROM TO DESCRIPTION(color,hardness,soil/rock type,grain size,etc.) ❑Geothermal(Heating/Cooling Return) 0 Other(explain under#21 Remarks) 0 ft. 54 ft Dirt 4.Date Well(s)Completed: 9-2-2023 Well ID# 54 ft- _1025 ft. Rock 5a.Well Location: ft. ft. C'-- d.f w Y� °' Gregory Smyre, II ft. ft. • (} Facility/Owner Name Facility ID#(if applicable) ft ft SE f _ 207:3 5476 Whitner Rd, Hickory NC 28602 ft. ft. _,.*.-,,;L_, lin% Physical Address,City,and Zip ft. ft. tn��' C..J •{� S`�%� Catawba 21.REMARKS • County Parcel Identification No.(PIN) 5b.Latitude and longitude in degrees/minutes/seconds or decimal degrees: (if well field,one lat/long is sufficient) 22. ertifrcation: 35.674.73' N 81 .403.42' W 44.4..e.ie., 9/13/2023 ,i�J 6.Is(are)the well(s): OPermanent or ❑Temporary nature of Certified Well Contractor• Date By signing this form,I hereby certify that the well(s)was(were)constructed in accordance with 7.Is this a repair to an existing well: ❑Yes or lNo ISA NCAC 02C.0100 or ISA NCAC 02C.0200 Well Construction Standards and that a copy If this is a repair,fill out known well construction information and explain the nature of the of this record has been provided to the well owner. repair under#21 remarks section or on the back of this form. 23.Site diagram or additional well details: 8.For Geoprobe/DPT or Closed-Loop Geothermal Wells having the same You may use the back of this page to provide additional well construction info construction,only 1 GW-1 is needed. Indicate TOTAL NUMBER of wells (add'See Over'in Remarks Box).You may also attach additional pages if necessary. drilled: 24.SUBMITTAL INSTRUCTIONS 9.Total well depth below land surface: 1025 (ft.) For multiple wells list all depths if different(example-3@200'and 2@I00') Submit this GW-1 within 30 days of well completion per the following: 100 24a. For All Wells: Original form to Division of Water Resources (DWR), 10.Static water level below top of casing: (ft.) Information Processing Unit,1617,MSC,Raleigh,NC 27699-1617 If water level is above casing,use"+" 11.Borehole diameter: 6.25 (in.) 24b.For Injection Wells:Copy to DWR,Underground Injection Control(IUC) Program,1636 MSC,Raleigh,NC27699-1636 12.Well construction method:Air Drilled 24c.For Water Supply and Open-Loop Geothermal Return Wells:Copy to the (i.e.auger,rotary,cable,direct push,etc.) county environmental health department of the county where installed ; FOR WATER SUPPLY WELLS ONLY: 24d.For Water Wells producing over 100,000 GPD:Copy to DWR,CCPCUA 13a.Yield(gpm) 2 Method of test:Air Permit Program,1611 MSC,Raleigh;NC 27699-1611 13b.Disinfection type: HTC Amount: 3 Cups Form GW-I North Carolina Department of Environmental Quality-Division of Water Resources Revised 6-6-2018 {