Loading...
HomeMy WebLinkAboutGW1--06358_Well Construction - GW1_20230927 WELL CONSTRUCTION RECORD(GW-1) For Internal Use Only: 1.Well Contractor Information: . Chris C Russell 14.WATERZONES Well Contractor Name FROM TO DESCRIPTION 3254 A 70 ft. 525 ft, 1 It. ft. NC Well Contractor Certification Number 15.OUTER CASING(for multi-cased wells)OR LINER(if ap licable) Russell Well Drilling, Inc. FROM TO DIAMETER THICKNESS MATERIAL 0 ft. 43 ft. 6.25 ; in* SDR21 PVC Company Name W P 953 16.INNER CASING OR TUBING(geothermal closed-loop) 2.Well Construction Permit#: FROM TO DIAMETER THICKNESS MATERIAL List all applicable well construction permits(i.e.UIC,County,State,Variance,etc.) ft. ft. in. 3.Well Use(check well use): ft. ft. in. 17.SC Water Supply Well: FROM REE TO DIAMETER SLOT SIZE THICKNESS MATERIAL ❑Agricultural ❑Municipal/Public ft. ft. in. ❑Geothermal(Heating/Cooling Supply) OResidential Water Supply(single) ft. ft. in. ❑Industrial/Commercial ❑Residential Water Supply(shared) 18.GROUT ❑Irrigation ❑Wells>100,000 GPD FROM , TO MATERIAL EMPLACEMENT METHOD&AMOUNT Non-Water Supply Well: 0 it' 20 ft, Grout Poured ❑Monitoring ❑Recovery ft. ft. Injection Well: ft. ft. ❑Aquifer Recharge ❑Groundwater Remediation 19.SAND/GRAVEL PACK(if applicable) ❑Aquifer Storage and Recovery ❑Salinity Barrier FROM TO MATERIAL EMPLACEMENT METHOD ❑Aquifer Test ❑Stormwater Drainage ft. ft. ❑Experimental Technology ❑Subsidence Control ft. ft. OGeothermal(Closed Loop) ❑Tracer 20.DRILLING LOG(attach additional sheets if necessary) ❑Geothermal(Heating/Cooling Return) ❑Other(explain under#21 Remarks) FROM TO DESCRIPTION(color,hardness soi0rocktype,grata size etc) 0 ft. 38 fr. Dirt 4.Date Well(s)Completed: 9-19-23 Well ID# 38 ft• 525 ft. Rock 5a.Well Location: ft. ft. Andrea & Martina Bueshnoy John Sprinkle ft. ft. ft. ft. --, r i, ,l y k r....s ) Facility/Owner Name Facility ID#(if applicable) t;-.'�t-:( -- ��' , 5417 Cedar Cove Way, Lenoir NC 28645 ft. ft. Physical Address,City,and Zip ft ft. S E P r 2023 Caldwell 21.REMARKS, ,.__: ,., In,'�;,' r.,..;a :';•gin•=, 711 ? . County Parcel Identification No.(PIN) r� ='f' 5b.Latitude and longitude in degrees/minutes/seconds or decimal degrees: (if well field,one lat/long is sufficient) 22.Ce tification: 35. 905.34' N 81 .671 .32' W �'�' • • 9/26/2023 6.Is(are)the well(s): OPermanent or ❑Temporary Signature of Certified Well Contractor Date By signing this form,I hereby certifii that the well(s)was(were)constructed in accordance with 7.Is this a repair to an existing well: ❑Yes or ONo ISA NCAC 02C.0100 or ISA NCAC 02C.0200 Well Construction Standards and that a copy If this is a repair,fill out known well construction information and explain the nature of the of this record has been provided to the well owner. repair under#21 remarks section or on the back of this form. 23.Site diagram or additional well details: 8.For Geoprobe/DPT or Closed-Loop Geothermal Wells having the same You may use the back of this page to provide additional well construction info construction,only 1 GW-1 is needed. Indicate TOTAL NUMBER of wells (add'See Over'in Remarks Box).You may also attach additional pages if necessary. drilled: 24.SUBMITTAL INSTRUCTIONS 9.Total well depth below land surface: 525 (ft) Submit this GW-1 within 30 days of well completion per the following: For multiple wells list all depths if different(example-3@200'and 2@100') 70 24a. For All Wells: Original form to Division of Water Resources (DWR), 10.Static water level below top of casing: (ft.) Information Processing Unit,1617:MSC,Raleigh,NC 27699-1617 If water level is above casing,use"+" 24b.For Injection Wells:Copy to DWR,Underground Injection Control(IUC) 11.Borehole diameter: 6.25 (in.) Program,1636 MSC,Raleigh,NC 27699-1636 12.Well construction method:Air Drilled 24c.For Water Supply and Open-Loop Geothermal Return Wells:Copy to the (i.e.auger,rotary,cable,direct push,etc.) county environmental health department of the county where installed FOR WATER SUPPLY WELLS ONLY: 24d.For Water Wells producing over 100,000 GPD:Copy to DWR,CCPCUA 13a.Yield m 4 Method of test Air Permit Program,1611 MSC,Raleigh;NC 27699-1611 (gP ) HTC Disinfection type: H I C Amount: 1 1/2 cup Form GW-1 North Carolina Department of Environmental Quality-Division of Water Resources Revised 6-6-2018