Loading...
HomeMy WebLinkAboutWQ0029945_Compliance Evaluation Inspection_20230928DocuSign Envelope ID: 9Bl700AC-606A-4B48-854A-44CFECBOB918 ROY COOPER Governor ELIZABETH S. BISER Secretary RICHARD E. ROGERS, JR. Director Edward M Caron Onslow Water and Sewer Authority 228 Georgetown Rd Jacksonville, NC 28540 NORTH CAROLINA Environmental Quality October 11, 2023 SUBJECT: Compliance Inspection Report Summerhouse WWTF Non -discharge Permit No. WQ0029945 Onslow County Dear Permittee: The North Carolina Division of Water Resources conducted an inspection of the Summerhouse WWTF on 9/28/2023. This inspection was conducted to verify that the facility is operating in compliance with the conditions and limitations specified in Non -discharge Permit No. WQ0029945. The findings and comments noted during this inspection are provided in the enclosed copy of the inspection report entitled "Compliance Inspection Report". There were no significant issues or findings noted during the inspection and therefore, a response to this inspection report is not required. If you should have any questions, please do not hesitate to contact Geoff Kegley with the Water Quality Regional Operations Section in the Wilmington Regional Office at 910-796-7215 or via email at geoff.kegley@deq.nc.gov. ATTACHMENTS Cc: DWR files — Laserfiche Sincerely, EDocuSigned by: T,,, �mn5�on for COAFC8EC8FCD446_. Morelia Sanchez -King, Regional Supervisor Water Quality Regional Operations Section Wilmington Regional Office Division of Water Resources, NCDEQ D North Carolina Department of Environmental quality I Division of Water Resources ,./ Wiimington Regional office 1127 Cardinal Drive Extension I Wilmington. North Carolina 26405 910.796,7215 DocuSign Envelope ID: 9Bl700AC-606A-4B48-854A-44CFECBOB918 Compliance Inspection Report Permit: WQ0029945 Effective: 05/01/20 Expiration: 12/31/25 Owner: Onslow Water and Sewer Authority SOC: Effective: Expiration: Facility: Summerhouse WWTF County: Onslow 85 Holly Rdg Rd Region: Wilmington Holly Ridge NC 28445 Contact Person: Edward M Caron Title: Directions to Facility: Phone: 910-937-7523 Follow NC Hwy 17 north to Holly Ridge, approx. 0.1 mile past the insterection of Hwy 17 and 50, turn R onto Morris Landing Rd. Travel approx. 1.7 miles to Holly Ridge Rd. on the left follow this road for approx. 1.6 miles to Kings Creek Crossing on the R System Classifications: WW3., Primary ORC: Kary Alexander Herndon Certification: 1012918 Phone: 910-937-7575 Secondary ORC(s): On -Site Representative(s): Related Permits: WQ0034067 Onslow Water and Sewer Authority - Stump Sound Wastewater Infrastructure Improvements Sewer WQCS00249 Onslow Water and Sewer Authority - ONWASA Collection System WQ0019907 Onslow Water and Sewer Authority - Holly Ridge WWTF Inspection Date: 09/28/2023 Entry Time 10:OOAM Exit Time: 12:15PM DocuSigned by: Primary Inspector: Geoff Kegley Phone: Secondary Inspector(s): 515D3B417_ Reason for Inspection: Routine Inspection Type: Compliance Evaluation Permit Inspection Type: High Rate Infiltration Facility Status: 0 Compliant ❑ Not Compliant Question Areas: Treatment Flow Measurement -Effluent Treatment Flow Measurement -Water Use Records Treatment Filters Treatment Sludge Storage/Treatment Treatment Flow Measurement (See attachment summary) Treatment Flow Measurement -Influent Miscellaneous Questions Treatment Treatment Barscreen Record Keeping Treatment Activated Sludge Treatment Disinfection End Use -Infiltration Treatment Return pumps Standby Power Page 1 of 6 DocuSign Envelope ID: 9Bl700AC-606A-4B48-854A-44CFECBOB918 Permit: WQ0029945 Owner - Facility:Onslow Water and Sewer Authority Inspection Date: 09/28/2023 Inspection Type: Compliance Evaluation Reason for Visit: Routine Inspection Summary: A routine compliance inspection of the Summerhouse WWTF was conducted on September28, 2023. The purpose of the evaluation was to verify that the facility is operating in compliance with the conditions and limitations specified in Permit WQ0029945, along with review of the proposed modifications to the treatment plant in the recent permit modification request. Kary Herndon from ONWASA is the ORC and was present during the inspection. The Division appreciates Mr. Herndon for his assistance during the inspection. The Summerhouse WWTF is permitted for 341,409 GPD and consists of: • two 5mm fine screens and an auxiliary manually cleaned bar screen • 2.4 MGD grit removal and dewatering system • influent flowmeter that measures flow from the Jenkins Street Pump Station • 184,373 gallon flow equalization basin • four 2-mm drum screens • four 44,000 gallon Membrane Bio-Reactor (MBR) basins each consisting of a 13,000 gallon anoxic basin, 27,000 gallon fine -bubble aeration basin, a 4,000 gallon membrane tank, and four racks of ten 15 gallon per day per square foot microfiltration modules, with chemical clean -in -place system • two 129,400 gallon aerobic sludge digesters • four UV disinfection chambers and a backup sodium hypochlorite system • Standby generator, odor control facility, turbidimeter, effluent flow meter • 2.54 MG synthetically -lined upset basin Disposal via: • 10.71 MG infiltration basin (Basin # 1) • 4. 74 MG infiltration basin ( Basin #2) • Groundwater control pump station and a 36-acre constructed groundwater lowering effluent discharge pond(Spicer Lake) ONWASA has the ability to divert flow from the Jenkins Street Pump Station in Holly Ridge to the Summerhouse WWTF for treatment when needed. In 2022 and 2023, the facility had 5 limit exceedance violations for total nitrogen and 2 limit exceedance violations of phosphorus. Effluent is currently sent to infiltration basin #2. In July 2021, infiltration basin #1 was certified for use but has not received flow yet. While the facility has the total disposal capacity of 341,409 GPD, the flow is limited by the functionality of the membranes and only two units are in operation. Average flows are around 72,000 GPD. The freeboard in the 5 day upset pond was less than 2 feet due to the recent heavy rainfalls/tropical events. Prior to these storms the freeboard in August was at 4 feet. They have been having to utilize a pump and haul permit to manage this high level. Upon installation of proposed modifications (new membranes), the plant should be able to handle higher flows through the membranes and this issue should be alleviated. Staff keeps organized records to include daily/weekly task check sheets, monthly data computer spreadsheets and a detailed operation/maintenance log book to monitor plant operations. The facility is compliant with non -discharge permit WQ0029945. Please review the comment sections of the inspection report for more details. Page 2 of 6 DocuSign Envelope ID: 9Bl700AC-606A-4B48-854A-44CFECBOB918 Permit: WQ0029945 Inspection Date: 09/28/2023 Owner - Facility:Onslow Water and Sewer Authority Inspection Type: Compliance Evaluation Reason for Visit: Routine Type Yes No NA NE Reuse (Quality) ❑ Single Family Spray, LR ❑ Lagoon Spray, LR ❑ Activated Sludge Spray, LR ❑ Activated Sludge Spray, HR ❑ Activated Sludge Drip, LR ❑ Recycle/Reuse ❑ Single Family Drip ❑ Infiltration System Treatment Yes No NA NE Are Treatment facilities consistent with those outlined in the current permit? 0 ❑ ❑ ❑ Do all treatment units appear to be operational? (if no, note below.) ❑ 0 ❑ ❑ Comment: Only two of four Membrane Bio-Reactors (MBR) are in operation, the other two are scavenged for parts. Proposed modification plans for replacing all MBRs. Treatment Flow Measurement -Influent Is flowmeter calibrated annually? Is flowmeter operating properly? Does flowmeter monitor continuously? Does flowmeter record flow? Does flowmeter appear to monitor accurately? Comment: Treatment Flow Measurement -Water Use Records Is water use metered? Are the daily average values properly calculated? Comment: Treatment Flow Measurement -Effluent Is flowmeter calibrated annually? Is flowmeter operating properly? Does flowmeter monitor continuously? Does flowmeter record flow? Does flowmeter appear to monitor accurately? Comment: Flowmeters were calibrated on 12/5/2022, turbidity meter was calibrated on 9/21/2023. Yes No NA NE • ❑ ❑ ❑ • ❑ ❑ ❑ • ❑ ❑ ❑ • ❑ ❑ ❑ • ❑ ❑ ❑ Yes No NA NE ❑❑❑■ ❑❑❑■ Yes No NA NE Standby Power Yes No NA NE Page 3 of 6 DocuSign Envelope ID: 9Bl700AC-606A-4B48-854A-44CFECBOB918 Permit: WQ0029945 Owner - Facility:Onslow Water and Sewer Authority Inspection Date: 09/28/2023 Inspection Type: Compliance Evaluation Reason for Visit: Routine Is automatically activated standby power available? 0 ❑ ❑ ❑ Is generator tested weekly by interrupting primary power source? 0 ❑ ❑ ❑ Is generator operable? ❑ ❑ ❑ Does generator have adequate fuel? ❑ ❑ ❑ Comment: The generator is automatically load tested weekly. Treatment Barscreen Yes No NA NE Is it free of excessive debris? ❑ ❑ ❑ Is disposal of screenings in compliance? ❑ ❑ ❑ Are the bars spaced properly? ❑ ❑ ❑ Is the unit in good condition? 0 ❑ ❑ ❑ Comment: Treatment Activated Sludge Yes No NA NE Is the aeration mechanism operable? 0 ❑ ❑ ❑ Is the aeration basin thoroughly mixed? ❑ ❑ ❑ Is the aeration equipment easily accessed? 0 ❑ ❑ ❑ Is Dissolved Oxygen adequate? ❑ ❑ ❑ Are Settleometer results acceptable? ❑ ❑ ❑ Is activated sludge an acceptable color? ❑ ❑ ❑ Comment: Micro-C is added in the anoxic basin Treatment Return pumps Yes No NA NE Are they in place? 0 ❑ ❑ ❑ Are they operational? 0 ❑ ❑ ❑ Comment: Treatment Filters Yes No NA NE Is the filter media present? 0 ❑ ❑ ❑ Is the filter media the correct size and type? 0 ❑ ❑ ❑ Is the air scour operational? ❑ ❑ ❑ Is the scouring acceptable? ❑ ❑ ❑ Is the clear well free of excessive solids? ❑ ❑ ❑ Is the mud well free of excessive solids and filter media? ❑ ❑ ❑ Does backwashing frequency appear adequate? ❑ ❑ ❑ Comment: The membranes are periodically cleaned with sodium hypochlorite and citric acid Treatment Sludge Storage/Treatment Yes No NA NE Is the aeration operational? ❑ ❑ ❑ Is the aeration pattern even? ❑ ❑ ❑ Page 4 of 6 DocuSign Envelope ID: 9Bl700AC-606A-4B48-854A-44CFECBOB918 Permit: WQ0029945 Owner - Facility:Onslow Water and Sewer Authority Inspection Date: 09/28/2023 Inspection Type: Compliance Evaluation Reason for Visit: Routine If required, are Sanitary "Ts" present in tankage? ❑ ❑ ❑ Comment: The aerobic digester solids are contracted for removal by Triple S Farms Treatment Disinfection Yes No NA NE Is the system working? 0 ❑ ❑ ❑ Do the fecal coliform results indicate proper disinfection? 0 ❑ ❑ ❑ Is there adequate detention time (>=30 minutes)? ❑ ❑ ❑ Is the system properly maintained? ❑ ❑ ❑ If gas, does the cylinder storage appear safe? ❑ ❑ ❑ Is the fan in the chlorine feed room and storage area operable? ❑ ❑ ❑ Is the chlorinator accessible? ❑ ❑ ❑ If tablets, are tablets present? ❑ ❑ ❑ Are the tablets the proper size and type? ❑ ❑ ❑ Is contact chamber free of sludge, solids, and growth? ❑ ❑ ❑ If UV, are extra UV bulbs available? ❑ ❑ ❑ If UV, is the UV intensity adequate? ❑ ❑ ❑ # Is it a dual feed system? ❑ ❑ ❑ Does the Stationary Source have more than 2500 Ibs of Chlorine (CAS No. 7782-50-5)? ❑ ❑ ❑ If yes, then is there a Risk Management Plan on site? ❑ ❑ ❑ If yes, then what is the EPA twelve digit ID Number? (1000- - ) If yes, then when was the RMP last updated? Comment: Each MBR train has an UV unit. Bulb hours are monitored. UV lights are cleaned with automatic wipers and occasionally cleaned with a hypochlorite solution. Record Keeping Yes No NA NE Is a copy of current permit available? ❑ ❑ ❑ Are monitoring reports present: NDMR? ❑ ❑ ❑ NDAR? ❑ ❑ ❑ Are flow rates less than of permitted flow? ❑ ❑ ❑ Are flow rates less than of permitted flow? ❑ ❑ ❑ Are application rates adhered to? ❑ ❑ ❑ Is GW monitoring being conducted, if required (GW-59s submitted)? ❑ ❑ ❑ Are all samples analyzed for all required parameters? ❑ ❑ ❑ Are there any 2L GW quality violations? ❑ ❑ ❑ Is GW-59A certification form completed for facility? ❑ ❑ ❑ Is effluent sampled for same parameters as GW? ❑ ❑ ❑ Do effluent concentrations exceed GW standards? ❑ ❑ ❑ Are annual soil reports available? ❑ ❑ ❑ Page 5 of 6 DocuSign Envelope ID: 9Bl700AC-606A-4B48-854A-44CFECBOB918 Permit: WQ0029945 Owner - Facility:Onslow Water and Sewer Authority Inspection Date: 09/28/2023 Inspection Type: Compliance Evaluation Reason for Visit: Routine # Are PAN records required? ❑ ❑ 0 ❑ # Did last soil report indicate a need for lime? ❑ ❑ 0 ❑ If so, has it been applied? ❑ ❑ 0 ❑ Are operational logs present? 0 ❑ ❑ ❑ Are lab sheets available for review? 0 ❑ ❑ ❑ Do lab sheets support data reported on NDMR? 0 ❑ ❑ ❑ Do lab sheets support data reported on GW-59s? ❑ ❑ 0 ❑ Are Operational and Maintenance records present? 0 ❑ ❑ ❑ Were Operational and Maintenance records complete? 0 ❑ ❑ ❑ Has permittee been free of public complaints in last 12 months? 0 ❑ ❑ ❑ Is a copy of the SOC readily available? ❑ ❑ 0 ❑ No treatment units bypassed since last inspection? ❑ ❑ 0 ❑ Comment: Records and operational and maintenance logs were organized and complete. A high water alarm was activated and functionina DroDerIv. SCADA and ORC's Dhone was notified. End Use -Infiltration Yes No NA NE # Is the application High Rate or Low Rate? High Rate Are buffers maintained? 0 ❑ ❑ ❑ Are any supply wells within the CB? ❑ ❑ ❑ Are any supply wells within 250' of the CB? ❑ ❑ ❑ Is municipal water available in the area? ❑ ❑ ❑ Are GW monitoring wells required? ❑ ❑ 0 ❑ Are GW monitoring wells located properly w/ respect to RB and CB? ❑ ❑ 0 ❑ Are GW monitoring wells properly constructed, including screened interval? ❑ ❑ 0 ❑ Is a usable green area maintained? ❑ ❑ 0 ❑ Is the disposal site acceptable? 0 ❑ ❑ ❑ Is the distribution equipment acceptable? 0 ❑ ❑ ❑ Is the disposal site free of ponding? ❑ ❑ 0 ❑ Is the disposal site free of breakout? 0 ❑ ❑ ❑ Are the disposal sites free of solids, algae, etc.? 0 ❑ ❑ ❑ Do the records show that the fields are properly maintained? 0 ❑ ❑ ❑ Are the disposal sites free of vegetation? 0 ❑ ❑ ❑ Do any surface water features appear to be adversely impacted by GW discharge? ❑ 0 ❑ ❑ No chemicals or rototiller used to eliminate vegetation, solids, algae, etc.? ❑ ❑ 0 ❑ Comment: Infiltration basin #2 is well maintained, Infiltration basin #1 water level maintained with well water for aesthetic purposes, has not received effluent flow yet. Freeboards: 4' in infiltration basin # 1, 2.6' in infiltration basin # 2, 1.8' in the 5 day upset pond. Page 6 of 6