HomeMy WebLinkAboutWQ0017443_Compliance Evaluation Inspection_20230224ROY COOPER
Governor
ELUABETH S. BISER
Secretary
RICHARD E. ROGERS, JR.
Director
David R. and Casandra B. Seed
47 Birnamwood Drive
Chapel Hill, NC 27516
NORTH CAROLINA
Envtronmental Quattty
April 28, 2023
Subject: Compliance Evaluation Inspection
Single Family Wastewater Treatment System
Non -Discharge Permit # WQ0017443
Facility: 47 Birnamwood Drive SFR
Chatham County
Dear Mr, and Mrs. Seed,
On February 24, 2023, Curtis Tyree from the Raleigh Regional Office visited your single-family
residence (SFR) wastewater treatment system to evaluate compliance with the subject Non -
Discharge Permit WQ0017443. Mr. Seed's assistance during the inspection was greatly
appreciated.
Our records indicate the treatment system consists of, a 1,200 gallon baffled septic tank; a 450
Square foot subsurface sand filter; a tablet chlorinator; two 1,500 gallon interconnected
storage/pump tanks with audible/visual high-water alarms; a 0.31 acre spray irrigation area with
nine full circle sprinklers; and all associated piping, valves, controls, and appurtenances.
Non -Discharge Permit WQ0017443 authorizes the continued operation up to 480 gallons per day
(gpd). The authorized irrigation is in accordance with the effluent limits and monitoring
requirements established within the non -discharge permit. The items below show what
conditions were noted at your facility:
Findings during the inspection were as follows:
1. Treatment system operation: The wastewater treatment system shall be
effectively maintained and operated at all times so there is no discharge to surface
waters, nor any contravention of groundwater or surface water standards. At the
North Carolina Department of Environmental Quality I Division of Water Resources
Raleigh Regional Office 13800 Barrett Dnve I Raleigh, North Carolina 27609
919 791 4200
time of this inspection, the facility appears to be effectively maintained. There
were no signs of runoff or ponding in the irrigation field. Mr. Seed informed
me that he checks the system on a regular basis.
2. Pumping the septic tank: You are required to inspect the septic tank at least
once a year to determine if solids must be removed or if other maintenance is
necessary. Septic tanks should be pumped out every five years or when the solids
level is found to be more than 1/3 of the liquid depth in the septic tank
compartment, whichever is greater. A pumping company can check the status
periodically and determine when pumping is required. Mr. Seed informed me
that he checks his septic tank at least once a year, he also informed me that the
tank had last been pumped out in March of 2020 by Scotty's Septic Tank
Service.
3. Chlorine tablets in the chlorinator; The permittee is to inspect the tablet
chlorinator weekly to insure there is an adequate supply of chlorine tablets for
continuous and proper operation. At the time of the inspection, the chlorinator
had an adequate amount of chlorine tablets, and the correct type of chlorine
tablets were being used. Mr. Seed checks the chlorinator once per week.
4. Proper Operation and maintenance: The system shall be inspected monthly to
make certain of the proper operation of the spray heads, that the system is free of
leaks, that the vegetative growth allows a proper spray pattern, that the soil is
assimilating the disposed treated wastewater with no surface run off, and that no
objectional odors are being generated. Any visible signs of a malfunctioning
system shall be documented, and steps taken to correct the problem. On the day
of this inspection, the spray field appeared to be assimilating the waste and no
ponding/runoff was observed. The pumps and audible/visual alarms were
working properly and the spray nozzles were spraying evenly. The system
appeared to be well maintained.
S. Field conditions: Public access to the irrigation sites and wastewater treatment
facilities shall be prohibited. Fencing shall be provided to prevent access to the
irrigation site. The irrigation field was well maintained, and no leaks or broken
lines were found. The fencing was more than adequate, and the system was in
great shape.
North Carolina Department of Environmental Quality I Division of Water Resources
Raleigh Regional Office 13800 Barrett Drive I Raleigh_ North Carolina 27609
919 791 4200
Non -discharge Permit WQ0010061 requires the permittee pay the annual fee within 30 days after
being billed by the division, and that the permittee must apply for a permit renewal 180 days
prior to the expiration of the permit. There are no overdue fees for the subject permit.
Please continue to periodically inspect the wastewater treatment facility in accordance with your
Operation and Maintenance agreement to ensure the treatment components are always
maintained and in good operating order. You are also reminded to maintain associated
maintenance records (permit required inspection log) onsite for a minimum of five years and
available for inspection.
If you have questions or comments about this inspection or the requirements to take corrective
action (if applicable), then please contact Curtis Tyree at 919-791-4239 or by email-
curtis.tyree ncdenr. ov .
Sincerely,
Vanessa E. Manuel, Assistant Regional Supervisor
Water Quality Regional Operations Section
Raleigh Regional Office
Division of Water Resources, NCDEQ
Attachment(s):
Cc: Laserfiche
05 North Carolina Department of Environmental Quality I Division of Water Resources
Raleigh Regional Office 13800 Barren Drive I Raleigh, North Carolina 27609
�� 919.791 4200
Compliance Ins ection Report
Permit: WQ0017443 Effective: 10/01/18 Expiration: 09/30/23 Owner: David R Seed
SOC: Effective: Expiration: Facility: 47 Bimamwood Dr. SFR
County: Chatham 47 Bimamwood Dr
Region: Raleigh
Chapel HIII NC 275164510
Contact Person: David R Seed Title: Phone:
Directions to Facility:
From Raleigh, 1-40W to exit 273A, NC 54W, 7.1 mi, Left on Jones Ferry Rd, 0.9 mi.. RT on Old Greensboro Rd, 5.3 mi, Left on White
Cross Rd, 2.5mi. Left on 2nd entrance to Bimamwood Dr, 1st house on left,
System Classifications:
Primary ORC: Certification: Phone:
Secondary ORC(s):
On -Site Representative(s):
Related Permits:
Inspection Date: 02124/2023 Entry Time 1 O:OOAM Exit Time: 10:35AM
Primary Inspector: Curtis R Tyree Phone: 919-791-4239
Secondary Inspector(s):
Reason for Inspection: Routine Inspection Type: Compliance Evaluation
Permit Inspection Type: Single -Family Residence Wastewater Irrigation
Facility Status: 0 Compliant ❑ Not Compliant
Question Areas,
Miscellaneous Questions Permit Status Septic Tank
Sand Filter/Treatment Pods Disinfection Tablets Pump Tank
Drip or Irrigation General
(See attachment summary)
Page 1 of 4
permit: W00017443 Owner - Facility: David R Seed
Inspection Date: 02/24/2023 Inspection Type: Compliance Evaluation Reason for Visit: Routine
Inspection Summary:
Page 2 of 4
Permit: W00017443 Owner - Facility: David R Seed
Inspection Date: 02t2412023 Inspection Type: Compliance Evaluation Reason for Visit: Routine
Permit Status Yes No NA NE
# Is the current resident in the home the Permittee? ME][--][]
# If not, does the resident rent from the Permittee?
Change of Ownership form needed? (Mail the form with the inspection letter)
# Is there an inspection and maintenance agreement with a contractor?
If YES, who is the contractor (include contact info)?
Mr. Seed inspects his system on a weekly basis.
Comment:
Septic Tank Yes No NA NE
`** The septic tank and filters should be checked annually and pumped/cleaned as needed. "*
Is all wastewater from the home connected to the septic tank? 0111311
# Does the permittee/resident know where the septic tank is located? M ❑ El 1:1
Has the septic tank been pumped in the last 5 years? M ❑ ❑ ❑
If YES, describe if known and proof (include date pumped):
The permittee checks the septic tank annually and Scotty's Septic Tank Service pumped the septic tank out
and cleaned the filter in March 2020.
# Does the septic tank have an EFFLUENT FILTER or SANITARY T?
If FILTER, when was the filter cleaned and by who? 2022 by permittee
Comment: The permittee checks the septic tank level annually and cleans the filter annually.
Sand Filter/Treatment Pods
Yes No NA NE
*** Accessible sand filter surfaces shall be raked/leveled every 6 months and vegetative growth shall be
removed manually. ***
# Is system something other than a sand filter?
# If YES, what kind? (examples - Peat, Textile or brand name - Advantex, etc.)
# Does the permittee know where the sandfilter is located?
Does the sandfilter require maintenance?
130110
If maintenace is required, explain:
Comment: The sand filter appears to be working as designed.
Disinfection Tablets
Yes No NA NE
*** Tablet chlorinator unit shall be checked weekly to ensure continuous and proper operation.
Does the permittee have the correct chlorine tablets? (If none, mark No)
0 ❑ 11 ❑
# Does the Permittee know the location of the chlorinator?
0 1:11111
Were chlorine tablets observed in the chlorinator?
Are tablets contacting water? (If possible, poke them to determine.)
[]
Comment: The permittee checks the chlorinator week)
Page 3 of 4
Permit: w00017443 Owner - Facility: David R Seed
Inspection Date: 02/24/2023 Inspection Type: Compliance Evaluation 4
Reason for Visit: Routine
Pump Tank
Yes No NA NE
*** All pump and alarm sytems shall be inspected monthly. (Non -Discharge) "*
Is the pump working?
M ❑ 1111
Is the audible and visual high water alarm operational?
M ❑ ❑ ❑
# Does the permittee know how to check the pump & high water alarm?
M ❑ 1111
# Last functional test:
January 2023
Comment: The permitte checks the alarms monthl
Drip or Irriyiation
Yes No NA NE
*** Irrigation sysetm shall be inspected monthly to ensure system is free of leaks and equipment is operating
as designed. ***
# Type of system (DRIP or IRRIGATION): Spray irrigation
# If IRRIGATION, number of sprinkler heads: 9
Are buffers and setbacks adequate? s ❑ ❑ ❑
Is the site free of ponding and runoff? M 110 ❑
Does the application equipment appear to be working properly? ❑ ❑ ❑
Is there a minimum two wire fence surrounding the entire irrigation area? ❑ ❑ ❑
Comment: There were noleaks or Dondina. the spray -field was well maintained and the fencing was more
than adacivate.
General Yes No NA NE
# Are the treatment units locked and/or secured? 0 ❑ ❑ ❑
# Has resident had any sewage problems? ❑ ❑ ❑
If YES, explain:
Does the system match the permit description? 0111111
If NO, explain:
Is the system compliant? ❑ ❑ ❑
Is the system failing? (If yes, take pictures if possible) ❑ ❑ ❑
If system is failing, describe any exposures to people/animals or environmental risks.
Comment: The system is well maintained and looks to be in great shape.