Loading...
HomeMy WebLinkAboutNCG551366_2023 Inspection Letter_20231010 North Carolina Department of Environmental Quality Division of Water Resources Raleigh Regional Office 3800 Barrett Drive Raleigh, North Carolina 27609 919.791.4200 October 16th, 2023 Kevin Hayden 314 Sandlewood Drive Durham, NC 27712 Subject: Compliance Evaluation Inspection Single Family Wastewater Treatment System General NPDES Permit NCG550000 Certificate of Coverage NCG551366 Facility: 314 Sandlewood Drive Durham County Dear Mr. Hayden: On September 26th, Kevin Fowler from the Raleigh Regional Office visited your single-family residence (SFR) wastewater treatment system to evaluate compliance with the subject General NPDES Permit. The assistance you provided over the telephone was greatly appreciated. Our records indicate the treatment system consists of a septic tank, sub-surface sand filter, tablet chlorinator, and a discharge pipe. General NPDES Permit NCG550000 and Certificate of Coverage (COC) NCG551366 authorize the discharge of domestic wastewater from your treatment system to receiving waters designated as a unnamed tributary to Cabin Branch (classified WS-IV;NSW) in the Neuse River Basin. The authorized discharge is in accordance with the effluent limits and monitoring requirements established within the General Permit. The items below show what conditions were noted at your facility: Findings during the inspection were as follows: 1. Pumping the septic tank: You are required to inspect the septic tank at least yearly to determine if solids must be removed or if other maintenance is necessary. Septic tanks should be pumped out every five years or when the solids level is found to be more than 1/3 of the liquid depth in the septic tank compartment, whichever is greater. A pumping company can check the status periodically and determine when pumping is required. After the inspection, Kevin Hayden provided documentation showing Scotty’s Sanitation pumped out the septic tank on 9/13/2023. The General NPDES Permit requires the permittee to retain records associated with sewage disposal activities for a period of at least 5 years. DocuSign Envelope ID: 5011F237-6DD1-4FAC-84D9-123EEBF6E800 North Carolina Department of Environmental Quality Division of Water Resources 512 North Salisbury Street 1611 Mail Service Center Raleigh, North Carolina 27699-1611 919.707.9000 2. Chlorine tablets in the chlorinator: You are reminded that it is required that chlorine tablets be maintained in the chlorinator to ensure proper disinfection of the discharged wastewater. Chlorine tablets provide effective disinfection and prevent/limit harmful bacteria from discharging to the environment. The product label for these tablets must indicate the tablets are approved for wastewater use and not for swimming pools. Part 1, Section D (1) of General NPDES Permit NCG550000 requires the permittee to inspect the tablet chlorinator weekly to ensure there is an adequate supply of tablets for continuous and proper operation. Section D (4) requires the permittee to maintain all system components, including...disinfection units...at all times and in good operating order. The inspector did not observe any chlorine tablets in the chlorinator. Please ensure the correct type of tablets are used and maintained in the chlorinator as required by the General NPDES Permit. 3. Analyzing the effluent: Part 1. C., Effluent Limitations and Monitoring Requirements, within General Permit NCG550000 requires a permittee to sample and analyze the effluent leaving his/her treatment system prior to discharge annually. Parameters to be sampled and analyzed include Flow, BOD (Biochemical Oxygen Demand), Total Suspended Solids, Fecal Coliform, Total Residual Chlorine, Total Nitrogen, Ammonia Nitrogen and Total Phosphorous After the inspection, you informed the inspector that the effluent has not been monitored within the last 12 months. Please collect a representative sample of the effluent, have it analyzed by a certified commercial laboratory and submit the results to this office no later than December 31, 2022.. In the last inspection letter dated February 5, 2018, you were requested to sample your effluent and to submit the analytical results to this office. The Raleigh Regional Office has not received the requested results. Failure to monitor the effluent discharge as required is a violation of NPDES General Permit NCG550000. 4. Discharge outlet location. The permittee is required to conduct a visual review of the outfall location at least twice each year (one at the time of sampling) to ensure that no visible solids or other obvious evidence of system malfunctioning is observed. Any visible signs of a malfunctioning system shall be documented and steps taken to correct the problem. The end of discharge pipe was not visible nor accessible the day of the inspection. To comply with the general permit monitoring requirements, you need to be able to sample and analyze the effluent from your SFR system through the discharge pipe. You need to keep the area around the discharge pipe cleared of vegetation, soil and leaves. Please take the necessary steps to ensure the discharge outlet is visible and accessible. Maintaining the area will allow you to monitor the discharge and to collect effluent samples as required by the subject permit. Part II Section B.14 of General Permit NCG550000 requires the permittee to “pay the annual administering and compliance monitoring fee within thirty days after being billed by the Division.” Division records indicate the required annual fee ($60 per year) for the period ending 12/31/2023 and due 1/01/2023, has been paid. There are no overdue fees for the subject COC. DocuSign Envelope ID: 5011F237-6DD1-4FAC-84D9-123EEBF6E800 North Carolina Department of Environmental Quality Division of Water Resources 512 North Salisbury Street 1611 Mail Service Center Raleigh, North Carolina 27699-1611 919.707.9000 The wastewater treatment system should be periodically inspected to ensure the treatment components are always maintained and in good operating order. You are also reminded to maintain all monitoring data and associated maintenance records onsite for a minimum of three years and available for inspection. Within 30-days receipt of this letter, please submit a written response to this office indicating the actions you will take or have taken to comply with or resolve the issues noted items 1, 2, 3, and 4 above. If you have questions or comments about this inspection or the requirements to take corrective action (if applicable), then please contact Kevin Fowler at 919-437-0047. Sincerely, Vanessa E. Manuel, Assistant Regional Supervisor Water Quality Regional Operations Section Raleigh Regional Office Division of Water Resources, NCDEQ Attachment(s): EPA Water Compliance Inspection Report DEQ Inspection Checklist Cc: Laserfiche DocuSign Envelope ID: 5011F237-6DD1-4FAC-84D9-123EEBF6E800 EPA United States Environmental Protection Agency Washington, D.C. 20460 Water Compliance Inspection Report Form Approved. OMB No. 2040-0057 Approval expires 8-31-98 Section A: National Data System Coding (i.e., PCS) Transaction Code NPDES yr/mo/day Inspection Type Inspector Fac Type 1 N 52 NCG551366 23/09/26 C S31112171819 20 21 66 Inspection Work Days Facility Self-Monitoring Evaluation Rating B1 QA ----------------------Reserved------------------- N67707172 73 74 75 80 Section B: Facility Data Name and Location of Facility Inspected (For Industrial Users discharging to POTW, also include POTW name and NPDES permit Number) 314 Sandlewood Drive 314 Sandlewood Dr Durham NC 27712 Entry Time/Date Permit Effective Date Exit Time/Date Permit Expiration Date 10:00AM 23/09/26 21/12/28 Name(s) of Onsite Representative(s)/Titles(s)/Phone and Fax Number(s) /// Other Facility Data 10:15AM 23/09/26 25/10/31 Name, Address of Responsible Official/Title/Phone and Fax Number Kevin Hayden,314 Sandlewood Dr Durham NC 27712///Contacted No Section C: Areas Evaluated During Inspection (Check only those areas evaluated) Permit Operations & Maintenance Records/Reports Facility Site Review Effluent/Receiving Waters Section D: Summary of Finding/Comments (Attach additional sheets of narrative and checklists as necessary) (See attachment summary) Name(s) and Signature(s) of Inspector(s)Agency/Office/Phone and Fax Numbers Date Kevin Fowler DWR/RRO WQ/919-791-4200/ Signature of Management Q A Reviewer Agency/Office/Phone and Fax Numbers Date EPA Form 3560-3 (Rev 9-94) Previous editions are obsolete. Page#1 10/11/2023 DocuSign Envelope ID: 5011F237-6DD1-4FAC-84D9-123EEBF6E800 10/11/2023 NPDES yr/mo/day 23/09/26 Inspection Type C3111218 1 Section D: Summary of Finding/Comments (Attach additional sheets of narrative and checklists as necessary) Dear Mr. Hayden: On September 26th, Kevin Fowler from the Raleigh Regional Office visited your single-family residence (SFR) wastewater treatment system to evaluate compliance with the subject General NPDES Permit. The assistance you provided over the telephone was greatly appreciated. Our records indicate the treatment system consists of a septic tank, sub-surface sand filter, tablet chlorinator, and a discharge pipe. General NPDES Permit NCG550000 and Certificate of Coverage (COC) NCG551366 authorize the discharge of domestic wastewater from your treatment system to receiving waters designated as a unnamed tributary to Cabin Branch (classified WS-IV;NSW) in the Neuse River Basin. The authorized discharge is in accordance with the effluent limits and monitoring requirements established within the General Permit. The items below show what conditions were noted at your facility: Findings during the inspection were as follows: 1.Pumping the septic tank: You are required to inspect the septic tank at least yearly to determine if solids must be removed or if other maintenance is necessary. Septic tanks should be pumped out every five years or when the solids level is found to be more than 1/3 of the liquid depth in the septic tank compartment, whichever is greater. A pumping company can check the status periodically and determine when pumping is required. After the inspection, Kevin Hayden provided documentation showing Scotty’s Sanitation pumped out the septic tank on 9/13/2023. The General NPDES Permit requires the permittee to retain records associated with sewage disposal activities for a period of at least 5 years. 2.Chlorine tablets in the chlorinator: You are reminded that it is required that chlorine tablets be maintained in the chlorinator to ensure proper disinfection of the discharged wastewater. Chlorine tablets provide effective disinfection and prevent/limit harmful bacteria from discharging to the environment. The product label for these tablets must indicate the tablets are approved for wastewater use and not for swimming pools. Part 1, Section D (1) of General NPDES Permit NCG550000 requires the permittee to inspect the tablet chlorinator weekly to ensure there is an adequate supply of tablets for continuous and proper operation. Section D (4) requires the permittee to maintain all system components, including...disinfection units...at all times and in good operating order. The inspector did not observe any chlorine tablets in the chlorinator. Please ensure the correct type of tablets are used and maintained in the chlorinator as required by the General NPDES Permit. 3.Analyzing the effluent: Part 1. C., Effluent Limitations and Monitoring Requirements, within General Permit NCG550000 requires a permittee to sample and analyze the effluent leaving his/her treatment system prior to discharge annually. Parameters to be sampled and analyzed include Flow, BOD (Biochemical Oxygen Demand), Total Suspended Solids, Fecal Coliform, Total Residual Chlorine, Total Nitrogen, Ammonia Nitrogen and Total Phosphorous After the inspection, you informed the inspector that the effluent has not been monitored within the last 12 months. Please collect a representative sample of the effluent, have it analyzed by a certified commercial laboratory and submit the results to this office no later than December 31, 2022.. In the last inspection letter dated February 5, 2018, you were requested to sample your effluent and to submit the analytical results to this office. The Raleigh Regional Office has not received therequested results. Failure to monitor the effluent discharge as required is a violation of NPDES General Permit NCG550000. 4.Discharge outlet location. The permittee is required to conduct a visual review of the outfall location at least twice each year (one at the time of sampling) to ensure that no visible solids or other obvious evidence of system malfunctioning is observed. Any visible signs of a malfunctioning system shall be documented and steps taken to correct the problem. The end of discharge pipe was not visible nor accessible the day of the inspection. To comply with the general permit monitoring requirements, you need to be able to sample and analyze the effluent from your SFR system through the discharge pipe. You need to keep the area around the discharge pipe cleared of vegetation, soil NCG551366 17 (Cont.) Page#2 DocuSign Envelope ID: 5011F237-6DD1-4FAC-84D9-123EEBF6E800 Permit:NCG551366 Inspection Date:09/26/2023 Owner - Facility: Inspection Type: 314 Sandlewood Drive Compliance Evaluation and leaves. Please take the necessary steps to ensure the discharge outlet is visible and accessible. Maintaining the area will allow you to monitor the discharge and to collect effluent samples as required by the subject permit. Part II Section B.14 of General Permit NCG550000 requires the permittee to “pay the annual administering and compliance monitoring fee within thirty days after being billed by the Division.” Division records indicate the required annual fee ($60 per year) for the period ending 12/31/2023 and due 1/01/2023, has been paid. There are no overdue fees for the subject COC. Page#3 DocuSign Envelope ID: 5011F237-6DD1-4FAC-84D9-123EEBF6E800 Permit:NCG551366 Inspection Date:09/26/2023 Owner - Facility: Inspection Type: 314 Sandlewood Drive Compliance Evaluation Operations & Maintenance Yes No NA NE Is the plant generally clean with acceptable housekeeping? Does the facility analyze process control parameters, for ex: MLSS, MCRT, Settleable Solids, pH, DO, Sludge Judge, and other that are applicable? Comment: Permit Yes No NA NE (If the present permit expires in 6 months or less). Has the permittee submitted a new application? Is the facility as described in the permit? # Are there any special conditions for the permit? Is access to the plant site restricted to the general public? Is the inspector granted access to all areas for inspection? Comment: Effluent Pipe Yes No NA NE Is right of way to the outfall properly maintained? Are the receiving water free of foam other than trace amounts and other debris? If effluent (diffuser pipes are required) are they operating properly? Effluent pipe was not located and is believed to be underground.Comment: Septic Tank Yes No NA NE (If pumps are used) Is an audible and visual alarm operational? Is septic tank pumped on a schedule? Are pumps or syphons operating properly? Are high and low water alarms operating properly? Comment: Sand Filters (Low rate)Yes No NA NE (If pumps are used) Is an audible and visible alarm Present and operational? Is the distribution box level and watertight? Is sand filter free of ponding? Is the sand filter effluent re-circulated at a valid ratio? # Is the sand filter surface free of algae or excessive vegetation? # Is the sand filter effluent re-circulated at a valid ratio? (Approximately 3 to 1) Page#4 DocuSign Envelope ID: 5011F237-6DD1-4FAC-84D9-123EEBF6E800 Permit:NCG551366 Inspection Date:09/26/2023 Owner - Facility: Inspection Type: 314 Sandlewood Drive Compliance Evaluation Sand Filters (Low rate)Yes No NA NE Sand Filter UndergroundComment: Disinfection-Tablet Yes No NA NE Are tablet chlorinators operational? Are the tablets the proper size and type? Number of tubes in use?2 Is the level of chlorine residual acceptable? Is the contact chamber free of growth, or sludge buildup? Is there chlorine residual prior to de-chlorination? Lid of chorinator missing. No Chlorine Tablets in Tubes. Tubes need to have dirt/debris cleaned out. Comment: Page#5 DocuSign Envelope ID: 5011F237-6DD1-4FAC-84D9-123EEBF6E800 DocuSign Envelope ID: 5011F237-6DD1-4FAC-84D9-123EEBF6E800 DocuSign Envelope ID: 5011F237-6DD1-4FAC-84D9-123EEBF6E800