HomeMy WebLinkAboutSW6221202_Email_20230727 Peck, Kaitlin From:Farkas, Jim J Sent:Thursday, July 27, 2023 9:05 AM To:John Oglesby Cc:Robert Sanders; Peck, Kaitlin Subject:RE: \[External\] RE: SW6221201 Ample Storage Sorry for not getting back to you sooner. The temporary pool is set by the invert of the lowest bypass invert (in this case, the bypass weir at elevation 193.7’). The minimum required treatment volume may pond to a shallower elevation (193.36’ per the calculations), but the design volume is based on the temporary pool surface elevation (which is based on the invert of the lowest bypass). We will be in the office today & Kaitlin will be in tomorrow. Please reach out to Kaitlin to arrange the submission drop off. Jim Farkas State Stormwater Engineer North Carolina Department of Environmental Quality Office: (919) 707-3646 Jim.farkas@deq.nc.gov From: John Oglesby <john@csd-engineering.com> Sent: Thursday, July 27, 2023 8:58 AM To: Farkas, Jim J <Jim.Farkas@deq.nc.gov> Cc: Robert Sanders <robert@csd-engineering.com> Subject: \[External\] RE: SW6221201 Ample Storage Importance: High CAUTION: External email. Do not click links or open attachments unless verified. Report suspicious emails with the Report Message button located on your Outlook menu bar on the Home tab. Good morning, will you be in the office today or tomorrow to receive the resubmittal? Did you or someone in your office see my message below? Thank you, John John F. Oglesby, PE 1 (919) 624-0997 mobile john@csd-engineering.com csd-engineering.com It is the professional opinion of CSD Engineering that this electronic information provides design information current as of the date of its release. It is the responsibility of the receiver of this document to examine it and determine whether it is the information requested. In the deliverance of this file we make no promise as to the usability or compatibility of this file. This file shall not be considered a certified document. From: John Oglesby Sent: Wednesday, July 12, 2023 4:00 PM To: Farkas, Jim J <Jim.Farkas@deq.nc.gov> Cc: Robert Sanders <robert@csd-engineering.com> Subject: RE: SW6221201 Ample Storage Importance: High Dear Jim, Thank you again for the review and providing the final comments below. I noticed that the temporary pool was calculated at 193.36 and this is consistent across all calculations, narrative, and plans. However, the O-M-EZ form is reporting 193.7. Based on the checking and rechecking of calculations, may I just update the O-M-EZ form and resubmit that? Also, I have done as recommended and resized the drawdown to 2.0” after analyzing the treatment volume. I will submit the following based on this revision:  Revised O-M-EZ and SuppEZ forms (from 193.70 to 193.36)  Revised narrative reporting drawdown volumes and times.  Revised drawdown calculation for design and treatment volumes.  Revised plan sheet C4.2 (from 2.5” orifice to 2.0” orifice) Please advise if this will be sufficient for the final approval. Also, will you be available tomorrow for hand delivery? Regards, John John F. Oglesby, PE (919) 624-0997 mobile john@csd-engineering.com csd-engineering.com It is the professional opinion of CSD Engineering that this electronic information provides design information current as of the date of its release. It is the responsibility of the receiver of this document to examine it and determine whether it is the information requested. In the deliverance of this file we make no promise as to the usability or compatibility of this file. This file shall not be considered a certified document. From: Farkas, Jim J <Jim.Farkas@deq.nc.gov> Sent: Wednesday, June 28, 2023 10:27 AM To: John Oglesby <john@csd-engineering.com> 2 Cc: terryw@lampemanagement.com; guyljr@lampemanagement.com; Robert Sanders <robert@csd-engineering.com> Subject: RE: SW6221201 Ample Storage John, I was looking over the additional information you provided on April 4, 2023. Everything looks good except for a few small issues: Please correct the following: - Prior Comment 1d – There still appears to be an issue with the drawdown calculations, The starting water elevation is shown as 193.36’ which does not correspond to the temporary pool surface elevation (193.7’) which impacts the driving head used to determine the rate of drawdown of the design volume. Please ensure that the starting water elevation (and by extension, driving head and drawdown rate) is based on the temporary pool surface elevation (193.7’ per the invert of the bypass mechanism on the outlet structure). NOTE: While not required per the MDC, it is recommended to size the drawdown orifice so that both the design volume (21,695 cf) and minimum required treatment volume (13,651 cf) drawdown within the required 2-5 day window (reducing the size of the drawdown orifice from 2.5” to 2.0” should address this). Please revise as needed. Please provide the following: - 1x hard copy & 1x electronic copy of the revised calculations. - 1x hard copy & 1x electronic copy of the revised Supplement-EZ Form Pages. - 2x hard copies & 1x electronic copy of the revised plan sheets (if applicable). - 1x hard copy & 1x electronic copy of any other items needed to address this issue. Hard copies should be mailed to me at the following address: For FedEx/UPS: Jim Farkas 512 N. Salisbury Street, Office 640M Raleigh, NC 27604 For USPS: Jim Farkas 1612 Mail Service Center Raleigh, NC 27699-1612 Hand Delivery: Please reach out to me prior to hand delivering a submission to make sure that I (or someone else in my group) will be able to receive the submission. Do not leave the package in the foyer with the security guard. NOTE: Hard copies should not be sent to a Regional Office. Doing so will delay the review process and the submission package may be lost while being sent from the Regional Office to me in the Central Office. Electronic copies should be uploaded at the following location: https://edocs.deq.nc.gov/Forms/SW-Supplemental-Upload Since these are really minor things, once I get the hard copies, anything else that may have changed from addressing these issues, and the documents are uploaded to Laserfiche (Provided everything is still in order), we can issue the permit without doing another formal review. Let me know if you have any questions. 3 Jim Farkas State Stormwater Engineer North Carolina Department of Environmental Quality Office: (919) 707-3646 Jim.farkas@deq.nc.gov From: Farkas, Jim J Sent: Tuesday, March 7, 2023 7:48 AM To: guyljr@lampemanagement.com; terryw@lampemanagement.com; john@csd-engineering.com; robert@csd- engineering.com Cc: Joyner, Melissa <melissa.joyner@ncdenr.gov> Subject: RE: SW6221201 Ample Storage Good Morning, The Division of Energy, Mineral and Land Resources (DEMLR), received additional information for a Stormwater th Management Permit Application for the subject project on December 6, 2022. A review of that information has determined that the application is not complete. Attached is a letter describing the items that need to be submitted. If you have any questions, please feel free to contact me. My contact information is listed below. Thank you, Jim Farkas State Stormwater Engineer North Carolina Department of Environmental Quality Office: (919) 707-3646 Jim.farkas@ncdenr.gov From: DeBerry, Margie <Margie.DeBerry@ncdenr.gov> Sent: Tuesday, December 6, 2022 1:31 PM To: guyljr@lampemanagement.com; terryw@lampemanagement.com; john@csd-engineering.com; robert@csd- 4 engineering.com Cc: Lawyer, Mike <mike.lawyer@ncdenr.gov>; Farkas, Jim J <Jim.Farkas@ncdenr.gov> Subject: SW6221201 Ample Storage Good afternoon, We received your post-construction stormwater permit application for the above mentioned project on 12/6/2022. Reviews under the standard permitting process generally take 75 calendar days, but can take up to 90 calendar days per statute (our other reviewer, Corey Anen, no longer works for the State, so this review may exceed 75 days). Please upload all documents that you mailed into our office through the link provided below. Be sure to choose the Central Office as the Primary Contact office. https://edocs.deq.nc.gov/Forms/SW-Supplemental-Upload IMPORTANT NOTE: Please ensure that each file is uploaded under its appropriate file type. Additional file types can be entered into the electronic form by clicking on the “Add Another Post-Construction File Upload” link directly below the “State Stormwater Information Uploads” section of the form. Please do not upload entire plan sets through this form, but rather upload the relevant individual sheets under the appropriate file type. Selecting the correct file type ensures that the files are properly named in the electronic repository and it helps expedite the review process. Please type in permit #: SW6221201 If you have any questions, please contact Jim Farkas Jim.Farkas@ncdenr.gov 919-707-3646. Thank you, Margie DeBerry Environmental Specialist, Division of Energy, Mineral, and Land Resources North Carolina Department of Environmental Quality Office: (919) 707-9209 margie.deberry@ncdenr.gov Email correspondence to and from this address may be subject to the North Carolina Public Records Law and may be disclosed to third parties by an authorized state official. 5