Loading...
HomeMy WebLinkAboutNC0029611_Draft_FactSheet_20231010 Fact Sheet for Permit Renewal Sept 2023 - NPDES Permit NC0029611 - Page 1 NCDEQ / DWR / NPDES EXPEDITED FACT SHEET - NPDES PERMIT RENEWAL NPDES Permit NC0029611 Caroline Robinson / Compliance & Expedited Permitting Unit / caroline.robinson@deq.nc.gov / Sept 2023 FACILITY INFORMATION Applicant/Facility Name Yadkin County Board of Education (Mitchell T Long, ORC) East Bend Elementary School WWTP Applicant Address/Mailing Address 121 Washington Street, Yadkinville, NC 27055 Facility Physical Address 205 School Street, East Bend, NC 27018 Permitted Flow (MGD) 0.007 MGD Type of Waste 100% Domestic, < 1 MGD Facility Class WW-1 County Yadkin Permit Status Renewal Regional Office WSRO STREAM CHARACTERISTICS Receiving Stream Logan Creek Stream Classification C Stream Segment 12-83-2-(0.3) Outfall Lat. 36° 10' 54" N 7Q10 - Summer (cfs) 1.6 Outfall Long. 80° 32' 14" W 7Q10 - Winter (cfs) 2.9 Drainage basin Yadkin-Pee Dee River Basin 30Q2 (cfs) 3.9 Subbasin 03-07-02 Average Flow (cfs) 11.6 HUC 030401011201 IWC (%) 0.67% (summer) / 0.37% (winter) 303(d) List No BASIC INFO FOR EXPEDITED PERMIT RENEWAL Does permit need Daily Max NH3 limits? No Does permit need TRC limits/footnote? No – Already present in permit. Does permit have toxicity testing? No – not a complex wastestream Does permit have any Special Conditions? Nutrient Reopener for High Rock Lake Does permit have instream monitoring? No New expiration date: Nov 30, 2028 FACILITY SUMMARY The Yadkin County Board of Education operates a 100% domestic wastewater treatment plant for an estimated 250 residents, that sends wastewater to the East Bend Elementary School WWTP nearby. The East Bend Elementary School WWTP is a minor facility (flow < 1 MGD) with a design capacity and permitted wastewater discharge of 0.007 MGD. The original NPDES permit for this facility was issued in March 1982. This facility utilizes the following treatment components: ⬧ Grease trap ⬧ Septic tank ⬧ Dosing tank with filters ⬧ Recirculating surface sand filter with dual recirculation pumps ⬧ Ultraviolet unit for disinfection ⬧ Chlorine disinfection & dechlorination equipment [backup system] ⬧ Dual effluent pumps Fact Sheet for Permit Renewal Sept 2023 - NPDES Permit NC0029611 - Page 2 RENEWAL SUMMARY This renewal contains the following changes: • Updated eDMR language for electronic data submission in Part I. A. (3). COMPLIANCE HISTORY East Bend Elementary School WWTP has not had an enforcement since 2007. The facility has been issued one NOD for a pH limit violation in 2019, and two NOVs for fecal coliform limit violations in 2022 and 2023, since the permit was originally issued in May 2019. Most recent inspection (May 2023) showed the facility to be in compliance.