Loading...
HomeMy WebLinkAboutWQ0033589_Application_20231009State of North Carolina Department of Environmental Quality Division of Water Resources Division of Water Resources 15A NCAC 02T .0700 — HIGH -RATE INFILTRATION SYSTEM — RENEWAL FORM: HRIS-R 02-21 Pursuant to 15A NCAC 02T .0107(b), if the application does not include all required information and the necessary supporting documentation, the application shall be returned. The application and attachments shall be prepared in accordance with 15A NCAC 02T .0100, 15A NCAC 02T .0700, and Division Policies. For more information, visit the Water Quality Permitting Section's Non -Discharge Branch website. The Applicant shall submit an electronic copy of the application and attachments uploaded as a single Portable Document Format (PDF) file to htt s://edoes.de .nc ov/Forms/NonDischar e-Branch-Submittal- Form-Vert, or emailed to Nan-Discharee.Renorts(&ncdenr.gov if less than 20 megahytes (MB). SECTION I — APPLICANT INFORMATION 1. Applicant: North Carolina Department of Natural & Cultural Resources - Aquariums Division - 7ennette's Pier 2. Permit No.: WQ0033589 3. Signature authority: Michael P. Remige Phone number: (252) 255-1501 Office Title: Director Email: mike.remige@ncaquariums.com 4. Mailing address: P.O. Box 1445 City: Nags Head State: NC Zip: 27959- 5. Contact person: Michael P. Remige Primary phone number: (252) 255-1501 Office Email: mike.remige@ncaquariums.com Secondary phone number: (252) 256-0755 Cell SECTION J . , FACILITY INFORMATION 1. Physical address: 7234 S. Virginia Dare Trail County: Dare Parcel No.: 006649000 City: Nags Head 2. Treatment facility coordinates to the sixth decimal degree: Latitude: 35.908988' Longitude:-75.598355' State: NC Zip: 27959- Method: Address matching ;; < SECTION III FLOW INFORMATION � - I. Permitted flow: 14640 GPD (The maximum allowable flow based on what has been permitted) 2. As -built flow: GPD (The maximum allowable flow based on what has been constructed) 3. Average flow: GPD (The average of all reported flows on the previous calendar year's NDMRs) 4. Hydraulic capacity: % (Divide the average flow in Item 3 by the As -built flow in Item 2) 5. Wastewater composition: Domestic: 100 % Industrial: % Stormwater: % SECTION IV --BILL INGINFORMATION 1. Billing address: P.O. Box 1445 City: Nags Head State: NC Zip: 27959- 2. Verify the Applicant does not have any overdue annual fees: https:lldeq.nc. gov/about/divisions/water-resources/water-resources-pennitslwa-epayments Pursuant to 15A NCAC 02T .0120(c), permits for renewing facilities shall not be granted if the Applicant or any affiliation has an unpaid annual fee. FORM: HRIS-R 02-21 Page 1 of 6 SECTION V _ OPERATOR IN, RESPONSIBLE:, CHARGE (ORC) INFORMATION' 1. ORC: David Robertson Grade: III Certification No.: 987714 Mailing address: PO Box 2560 City: Kitty Hawk State: NC Zip: 27949- Phone number: (252) 489-9711 Cell Email: dobertson@atlanticsewage.com 2. Back -Up ORC: James Bliven Grade: 1V Certification No.: 991879 Mailing address: PO Box 2560 City: Kitty Hawk State: NC Zip: 27949- Phone number: (252) 489-9583 Cell Email: jbliven@atlanticsewage.com SECTION VI- OPEN -ATMOSPHERE, STRUCTURES 1. List all open -atmosphere treatment and storage structures associated with the renewing permit. Attach additional sheets if necessary. Type Parcel No. Volume (gal) Liner Type Freeboard (ft) Latitude Longitude Select Select 0- ° Select Select - ° Select Select Select Select ° SECTION; VII = RELATED PERMITS 1. List all wastewater permits (i.e., sewer, collection system, NPDES, residuals) that have interactions with the renewing permit. Attach additional sheets if necessary. Permit Type Permit No. Relationship Type Select Select Select Select Select Select Select Select SECT)CON ViII MONITORING; WELLS:. 1. List all groundwater monitoring wells associated with the renewing permit, Attach additional sheets if necessary. Well Name Parcel No. Status Gradient Location Latitude Longitude Select Select Select ° ° Select Select Select ° - ° Select Select Select ° - ° Select Select Select ° Select Select Select - ° Select Select Select ° Select Select Select ° Select Select Select Select Select Select ° ° Select Select Select 0° Select Select Select ° - ° FORM: HRIS-R 02-21 Page 2 of 6 SECTION IX — INFILTRATION SITES 1. List all infiltration sites associated with the renewing permit. Attach additional sheets if necessary. Site County Parcel No. Deeded Owner Area Cover Crop Latitude Longitude I Dare 006649000 North Carolina State 35.90916"-75.5984040 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 O 0 0 0 0 0 O O 0 O 0 O 0 O 0 O 0 O 0 0 0 ❑ 0 O 0 0 0 0 0 O 0 O 0 O 0 0 0 0 0 O 0 ❑ 0 O 0 O 0 0 O 0 0' Total Acreage: FORM: HRIS-R 02-21 Page 3 of 6 ATTACHMENT A —SITE: MAP Was the facility originally permitted or had a major modification issued after September 1, 2006? ® Yes — Pursuant to 15A NCAC 02T .0105(d), submit a site map pursuant to the requirements in 15A NCAC 02T .0704(d. These requirements are: 'V& A scaled map of the site with topographic contour intervals not exceeding 10 feet or 25 percent of total site relief and showing all facility -related structures and fences within the wastewater treatment, storage, and 'infiltration areas. ❑ Soil mapping units shown on all infiltration sites. ❑ The location of all wells (including usage and construction details if available), streams (ephemeral, intermittent, and perennial), springs, lakes, ponds, and other surface drainage features within 500 feet of all wastewater treatment, storage, and infiltration sites. ❑ Delineation of the compliance and review boundaries per 15A NCAC 02L .0107 and .0108. ❑ Setbacks as required by 15A NCAC 02T .0706. ❑ Site property boundaries within 500 feet of all wastewater treatment, storage, and infiltration sites. ❑ All habitable residences or places of public assembly within 500 feet of all treatment, storage, and infiltration sites. ❑ No - Skip Attachment A. ATTACHMENT B:— SIGNATURE AUTHORITY DELEGATION Does the signature authority in Section I, Item 3 meet the requirements pursuant to 15A NCAC 02T .0106(b)? ® Yes — Skip Attachment B. ❑ No — Submit a delegation letter pursuant to 15A NCAC 02T .0106 c authorizing the signature authority to sign. ATTACHMENT C= FLOW REDUCTION Does the existing permit include an approved flow reduction? ❑ Yes — Submit a copy of the flow reduction approval letter, as well as the measured monthly average amount of wastewater flow contributed per unit for the 12 months prior to permit renewal. If any of these monthly averages are within 20% of the approved flow reduction value, the Permittee shall provide a reevaluation of the reduced flow value pursuant to the requirements in 15A NCAC 02T .0I 14(f). ® No — Skip Attachment C. ATTACHMENT E OPERATIONAL AGREEMENT Is the Applicant a Home/Property Owners' Association or Developer of Lots to be Sold? ❑ Yes (Home/Property Owners' Association) —Pursuant to 15A NCAC 02T .0115(a](2)I submit an executed Operational Agreement (FORM: HOA). Pursuant to 15A NCAC 02T .0115(c), if the applicant is a legally formed Homeowners' or Property Owner's Association, submit a copy of the Articles of Incorporation, Declarations, and By-laws. ❑ Yes (Developer of Lots to be Sold) — Pursuant to 15A NCAC 02T .0115(a), submit an executed Operational Agreement (FORM: DEV). Pursuant to 15A NCAC 02T .0115(b), if the applicant is a developer of lots to be sold, submit a copy of the Articles of Incorporation, Declarations, and By-laws. ® No — Skip Attachment E. FORM: HRIS-R 02-21 Page 4 of 6 ATTACHMENT F- DEMONSTRATIONOF FUTURE WASTEWATER':TREATMENT CAPACITIES . Is the applicant a municipality, county, sanitary district, or public utility? ❑ Yes — Proceed to the next question. ® No — Skip Attachment F. Does the hydraulic capacity in Section 1II, Item 4 exceed 70%? ❑ Yes (the hydraulic capacity is greater than 70%, but less than 80%) — Pursuant to 15A NCAC 02T .0118 1 , prior to exceeding 80 percent of the system's permitted hydraulic capacity (based on the average flow during the last calendar year), the permittee shall submit an engineering evaluation of their future wastewater treatment, utilization, and disposal needs. This evaluation shall outline plans for meeting future wastewater treatment, utilization, or disposal needs by either expansion of the existing system, elimination or reduction of extraneous flows, or water conservation and shall include the source of funding for the improvements. If expansion is not proposed or is proposed for a later date, a justification shall be made that wastewater treatment needs will be met based on past growth records and future growth projections, and as appropriate, shall include conservation plans or other measures to achieve waste flow reductions. ❑ Yes (the hydraulic capacity greater than 80%) — Proceed to the next question. ❑ No — Skip Attachment F. If answered Yes above, does the hydraulic capacity in Section III, Item 4 exceed 80%? ❑ Yes (the hydraulic capacity is greater than 80%) — Pursuant to 15A NCAC 02T .0118(2 , prior to exceeding 90 percent of the system's permitted hydraulic capacity (based on the average flow during the last calendar year), the permittee shall obtain all permits needed for the expansion of the wastewater treatment, utilization, or disposal system and, if construction is needed, submit final plans and specifications for expansion, including a construction schedule. If expansion is not proposed or is proposed for a later date, a justification shall be made that wastewater treatment needs will be met based on past growth records and future growth projections, and as appropriate, shall include conservation plans or other specific measures to achieve waste flow reductions. ❑ No — Skip Attachment F. ATTACHMENT G = EASEMENT, ENCROACHMENT; AND LEASE'AGREEMENTS Does the Permittee own all of the land associated with the wastewater collection, treatment, conveyance, infiltration, and groundwater lowering (if applicable) system? ® Yes — Skip Attachment G. ❑ No — Pursuant to 15A NCAC 02T .01 16c , provide a copy of all easements, lease agreements, and encroachment agreements allowing the Permittee to operate and maintain the wastewater collection, treatment, conveyance, infiltration, and groundwater lowering (if applicable) system on property not owned by the Permittee. ..ATTACHMENT H� —:AFFILIATIONS";.. Are the Permittee's affiliations of record correct? Check affiliations. ® Yes Skip Attachment H. ❑ No Provide the corrected affiliations and their contact information. ATTACHMENT L� COMPI;IANCE SCHEDULES Does the existing permit include any Compliance Scbedules? (See Section I of the most recently issued permit) ❑ Yes — Submit documentation that the compliance schedules have been met. ® No — Skip Attachment I. FORM: HRIS-R 02-21 Page 5 of 6 ATTACHMENT K `- IMUSTRIAL WASTEWATER ... J Does the wastewater composition in Section III, Item 5 include any industrial wastewater? ❑ Yes — Proceed to the next question. ® No — Skip Attachment K. Has the nature of the industrial wastewater changed since the last permit issuance (i.e., changes in industrial process, introduction of new materials or chemicals, etc.)? ❑ Yes — Provide a chemical analysis of the wastewater pursuant to the requirements in 15A NCAC 02T .0704(h). Provide an overview of the manufacturing process; an inventory of all chemical and biological materials used in the manufacturing process; and an overview of the cleaning and treatment methodology. ❑ No — Provide an overview of the manufacturing process; an inventory of all chemical and biological materials used in the manufacturing process; and an overview of the cleaning and treatment methodology. ATTACHMENT L — SETBACK WAIVERS Does the existing permit include setback waivers? ❑ Yes — Pursuant to 15A NCAC 02T .0706(d), provide setbacks waivers that have been written, notarized, signed by all parties involved, and recorded with the county Register of Deeds. Waivers involving the compliance boundary shall be in accordance with 15A NCAC 02L .0107. ® No — Skip Attachment L. APPLICANT'S CERTIFICATION, 1, 1ckm;ZeY that this application (Signature authorit)'s name as noted in Section I, Item 3) has been reviewed by me and is accurate and complete to the best of my knowledge. I understand that if all required parts of this application package are not completed, and that if all required supporting information and attachments are not included, this application package will be returned as incomplete. I further certify pursuant to 15A NCAC 02T .0120 , that the applicant, or any parent, subsidiary, or other affiliate of the applicant has: not been convicted of environmental crimes under; not previously abandoned a wastewater treatment facility without properly closing the facility; not paid a civil penalty; not been compliant with any compliance schedule in a permit, settlement agreement, or order; not paid an annual fee. Note: The Applicant's Certification shall be signed pursuant to 15A NCAC 02T .0106(b). An alternate person maybe delegated as the signing official if a letter is provided pursuant to 15A NCAC 02T .0106(c). Pursuant to § 143-215.6A and § 143-215.6B, any person who knowingly makes any false statement, representation, or certification in any application package shall be guilty of a Class 2 misdemeanor, which may included -fee noI't&xceed $10,000 as well as civil penalties up to $25,000 per violation. Signature: �'� ��� A.� Date: a&?-wo i� , THE COMPLETED APPLICATION AND ATTACHMENTS SHALL BE SUBMITTED AS A SINGLE PDF FILE VIA: Email: Non-Discharue.Regorts(&ncdenr.sov Laserfiche Upload: htt s:lledoes.de .ne. ov/Forrus/NonDischar e-Branch- Submittal-Form-Vert FORM: HRIS-R 02-21 Page 6 of 6 4 . . . ... . . .. . . . .. ..... .. ..... .. . . . . .. .. . doll N. SINCE 11959 _j 'p J wuible yk N. A cla so -W.- c 0. CMULTING PLANNIN ENGINEERING r 16 ENVIRONMENTAL. SCIENCES SUWEYING - a' 7 NC Umnsof. C-0206. _.5� -- --- -- PO Drawer 870, U" Rawk,.NC 27949 -3300 Phonic (252) 261 A R C H I T E C T S Fax: (252) 261 -1 M 4 i ...... .. ... t � , am 514 Market Street 1 116 ? Wilmington, NC 28401 L �v__ T,51 (910) 762-2621 �­P Fax - (910) 762-6506 ..... ...... R E C 0 R D D R A W I N G RECORD DRAWINGS RECEIVED 1% FROM ......... CLANCY & THEYS _v- 7 �j .117) DA Tl 12/27/2011 SEE ALSO RD1-RD7 < .7 CID /A. J� y;,�, �A, zz, A N IN MA I N I m A ENT!S. 17 IS NOT AS -BUILT iNFOl AMPj IIAS U07 ElEiEN COLLECTED BY A NC ul PROFESSIONAL LAND SUAvEyl .7............. ........... --RUE I A T- ... ....... ............... ------- . ........ 7777. 14 #070704901 TREATMEN ---- WASPAPUWATE011111111 rim . .... . . .... u) A&ME co ......... . cc ly EAR YMME An cio > co '7 I r 7— > W '�Z, 3 N1 1,1 .1 3, > p c C) TEWATE13% TREATM WAS ENT T E > =I U) TL THE WASTEEWAiEli TREATMENT SYS_� To BE NSTALLE11 AT 'PHS !RT-F OUST MEET TiHE FOl CRITERIA- t. WAS'llf-WATER E�FLl CRITMA Ill AVERAGE DAILY MA) FIVE DAY EFOCK EMICAL CMEIN DEMAND (BODn) 10 NG 15 NPAVIONIA-MITROGEN (l 4 :5 mr./L TOTAL SUSPENDED W-110IS (TSS) 5 Y_G/L 10 NiTRATE- NITROGEN (NOS-14) 10 FEMAL COIJIFORMS 14 F-FIR I DO ML 25 PER 10D MIL T 7 MG/L ,l NITROGEN (TIN) TOTAL PHOSPHil l 3 MG/�_ 10 NTU 2. WASTEWATER TRrAlUD'T S'MM4 WUST ErE A SUEl A.7TACHM l E10-REACTOR 3� THE MANUFACTURER OF THE WASTMTVR IRF-ATME14T SYS-I'EM OOMPONEN7S MUST Ol A WA$7E`l 7RF-A'WMT SYS" PROCESS ISLIARAl TO NlIEET OR. EXCEED 7�ill SfAl LISIED ARl THE SySjjM ILLUSWTM a . N . PLAN SHEET . S C-13 TO C-25 IS WE SOGGESTED SYSTil CMMUIRATION. ALTERNATE DESIGN P90PDSALS UanNG THIS EFFLMT. CFh-El 14AY 6F CONSIDERED 8'� THE OWNER SUaJECT TO THE AJ`�FROVAL OF T�rE DESGR FNGINMeS RnIEW AND THE N10TH =90UNA tEPA.FTLACENT OF �NMROMMENIT- & NATURAL RESOURCES (MCDE&MR). QNSIM OF WA-IM VdAUTY (OVILO) -APPROVAL OF -w SAWE. ALTERNATE CONFIGURAMONS CAN DIE SUBMITTED FOR REME:W To THE FFojEl ENGWEE-R. ALTERNATE CONFIGUl V-LL REQUIRF7 A MODLIFLGATION TO TAE PERP41T AS ISSUED- Ell 7hE NICDEW DWIC. DEESM MLODIFICATFON VXRX TO AMM THE PERMIT MILL BE THE RESPONSOLITY OF THE CONTRACM.R. ALL REGLANED WATER PIPING, VALVES, OL17LETS MID l APFURTEl SHAJI RE� COLOR -CODED, TAPED OR GTHERIMSE MARMID To Ibll THE SOURCE Orr IFE WATM AS OEING RECLAIMED AS FOLILl t ALL RMLAIMED WATER PIPINC AND APPURTENANCES SHALL BE E17HER COLORED PURPLE CPANT�)NE 522� AND EMBOSSED OR INTEMALLY STAMPED OR MARKM *QAUL!1ON,' RECLAIMED WAMR - DO I. NOT MNK' OR BE 'MALLF-0 NTH PURPLE (PANTONE 522) IDENTIMil TAPE OR POLYEhTd-ENE VINYL WRAP. TVE WARNING SHALL BE STAMPED ON OPPOSTF -SIDES OF THE PIPE. AND REPEATED EWRY 3 OR LT�S 1, IVENTIFICA111IN TAPE SHALL BE AT LEAST 3, INCHES VADE AND HAVE MITE OF? LE. =JING ON PURPLE (PANTl 522) FIELD STATING 'CA"l RECLAIMED WATM - DO NOT DRINK' TDNEnFICAT?l TAPE SHALL BE LNSTALLED ON.TOP OF RECLAIMED I TO EACH FlIPE LENGTH WATER Pli'll 7AS7ENED EMZY 10 FEEi AND RM CON11NUOUSLY 7HE ENTIRE LNOTH OF 74E PIPE. ce) mir -dos", Z GROUND b K ll%___� Z_ WA 114 I I 1 -1 �7 f ­ W. 11 01s, m 9E ]am T 7 mvMim 11111,1111F MUM HEAME N.T.S. MAE ZvA= < LU > 0 m C.) REVISIONS -1AGIONS AS PER SM & DIDI comutl 2 .10/17/bB REMSE T1TtFz 13LON INAME AND LOGO Exam 11/3/011 Ill SAMN OETAIL 290. VANIM 1/19 REWISIONS'AS PER IDW ....... - IREVEW C(NMEll 5/26/09 11il 717LE BLOM NAME JOB NUMBER F, P06086-BASE PRAWN BY TA,9/JJA CHECKED BY LJ DATE . ...... OCTOBER 22,2008 SHEET NUMBER A-0- %UPI 4 61512009 3A3 PM