Loading...
HomeMy WebLinkAboutWM0401482_Application_20231004NORTH CAROLINA DEPARTMENT OF ENVIRONMENTAL QUALITY - DIVISION OF WATER RESOURCES APPLICATION FOR PERMIT TO CONSTRUCT A MONITORING OR RECOVERY WELL SYSTEM PLEASE TYPE OR PRINT CLEARLY In accordance with the provisions of Article 7, Chapter 87, General Statutes of North Carolina and regulations pursuant thereto, application is hereby made for a permit to construct monitoring or recovery wells. 1. Date: 09/05/2023 2. County: Davidson FOR OFFICE USE ONLY PERMIT NO. ISSUED DATE 3. What type of well are you applying for? (monitoring or recovery): Monitoring 4. Applicant: Mannington Mills. Inc. Telephone: 856.339.5871 Applicant's Mailing Address: 75 Mannington Mills Road, Salem NJ 08079 Applicant's Email Address (if available): da✓c.kitts cumannington.com 5. Contact Person (if different than Applicant): Tom Dunham, SynTerra Corp Telephone: 919-632-3465 Contact Person's Mailing Address: SynTerra Corp., 511-102 Keisler Dr. Cary, NC 27518 Contact Person's Email Address (if available): tdunhamia�svntarracorp.coin 6. Property Owner (if different than Applicant): Condumex Inc. Telephone: 972-352-2340 Property Owner's Mailing Address: 900 Avenue S Grand Prairie Texas 75050 Property Owner's Email Address (if available): alex@condumex.com 7. Property Physical Address (Including PIN Number) 6 Edna Street (6724-02-56-0494) City Lexington County Davidson Zip Code 27292 8. Reason for Well(s): groundwater assessment (ex: non -discharge permit requirements, suspected contamination, assessment, groundwater contamination, remediation, etc.) 9. Type of facility or site for which the well(s) is(are) needed: RCRA (ex: non -discharge facility, waste disposal site, landfill, UST, etc.) 10. Are there any current water quality permits or incidents associated with this facility or site? If so, list permit and/or incident no(s). Hazardous Waste Management Permit, Permit No. NCD 986 181 451 11. Type of contaminants being monitored or recovered: metals (ex: organics, nutrients, heavy metals, etc.) 12. Are there any existing wells associated with the proposed well(s)? If yes, how many? Yes 19 Existing Monitoring or Recovery Well Construction Permit No(s).: unknown 13. Distance from proposed well(s) to nearest known waste or pollution source (in feet): 250 feet 14. Are there any water supply wells located less than 500 feet from the proposed well(s)? no If yes, give distance(s): 15. Well Contractor: Geologic Exploration, Brian Thomas Certification No.: NCWC 2581-A Well Contractor Address: 176 Commerce Blvd Statesville NC 28625 PROPOSED WELL CONSTRUCTION INFORMATION 1. As required by 15A NCAC 02C .0105(f)(7), attach a well construction diagram of each well showing the following: a. Borehole and well diameter e. Type of casing material and thickness b. Estimated well depth f. Grout horizons C. Screen intervals g. Well head completion details d. Sand/gravel pack intervals Continued on Reverse PROPOSED WELL CONSTRUCTION INFORMATION (Carrtinued) Number of weiis to be constructed in unconsolidated 5. How will the well(s) be secured? Protective steel material 3 rasing with pad Number of wells to be constructed in bedrock L___ Total Number of wells to be constructed 4 (add answors from 2 and 3) Estimated beginning construction date 9-3,-1-23 Estimated construction Completion date. 9 97 233 ADDITIONAL INFORMATION As required by 15A NCAC 02C .0105(f)(5), attach a scaled map of the site showing the tocalions of the following a. All property boundaries, at least one of which is referenced to a minimum of two landmarks such as identified roads, intersections, streams, or lakes within 500 feet of the proposed well or well system b. All existing wells, identified by type of use, within 500 feet of the proposed well or well system c The proposed well or well system d. Any test borings within 500 feet of proposed well or well system e All sources of known or potential groundwater contamination (such as septic tank systems, pesticide, chemical or fuel storage areas, animal feedtats as defined in G S. 143.215.108(5), landfills, or other waste disposal areas) within 500 feet of the proposed well or well system SIGNATURES The Applicant assumes total 7pnibilky for ensuring that the well(s) will be located, constructed, maintained, and abandoned in accordance with 15A NCAC 02C l s 1 C ^�a� Si ature of Applicant or 'Agent Title df Applica oi'Agent U { ' if signing as Agent, attach authohzarron agreement staling Prin ed name of Applicant or Agent that you have the authority to act as the Agent. 11 the property is owned by someone other than the Applicant, the property owner hereby consents to allow the Applicant to construct well(s) as outline in this Well Construction Permit application and acknowledges that it shall be the responsibility of the Applicant to ensure t well(,) will be located, constructed, maintained, and a on in accordance with i5A NCAC 02C, 4n z - Signature of Pr arty wrier (if different than Applicant) Pri ted name of Property Owner ( -different than Applicant) DIRECTIONS Please sC7nd the completed application to the appropriate Division of Water Resources' Regional Office - Asheville Regional Office Raleigh Regional Office Wilmington Regional Office 2090 US Highway 70 3800 Barreft Drive 127 Cardinal Dine Extension Swannanoa, NC 28778 Raleigh, NC 27609 Wilmington, NO 28405 Phone (828) 296.4500 Phone: (919) 791-4200 Phone (910) 796-7215 Fax: (628) 299-7043 Fax (919) 571-4718 Fax (910) 350-2004 Fayetteville Regional Office 226 Green Street, Suite 714 Fayetleville, NO 28301-5094 Phone (910) 433-3300 Fax: (910) 486-0707 Mooresville Regional Office 610 East Center Avenue Mooresville, NC 28115 Phone. (704) 663-1699 Fax: (704) 663-6040 Washington Regional Office 943 Washington Square Mall Washington, NC 27889 Phone: (252) 946-6481 Fax. (252) 975-3718 Wlnston•Salem Regional Office 450 W Hanes Mill Road Suite 300 Winston-Salem, NO 27105 Phone: (336) 776-9800 Fax- (336) 776-9797 GW-2ZMIR (Rav 5.2&20221 Locking Well Cap Upright Protective Cover with Lock Land Surface 3' Radius or 4' by 4' Concrete Pad 6" Borehole Diameter (Nominal Dimension) Cement Grout 2" Schedule 40 PVC Casing w/ Threaded Couplings Approximate 2' Bentonite Seal v c O fV N O > Well Sorted Sand Pack v v ♦� Water Table 10' Screened Interval v 0.010" Slotted Screen o 2" Schedule 40 PVC fV m Sump/Sediment Trap Bottom Cap Estimate Depth = 40' 148 RIVER STREET, SUITE 220 GREENVILLE, SOUTH CAROLINA 29601 PHONE (864) 421-9999 FIGURE 3 HTTP://W W W.SYNTERRACORP.COM GENERALIZED MONITORING WELL SCHEMATIC synTerra ov - _� I6b ♦ . FEDERAL O e _VC,F 13 r ' Meadovavieva - �.S;I' - I • i Lexlnytor) 9 ���IA1 p4 a'11 -- �AROM,., ;r LEGEND _ r PROPERTY BOUNDARY SURFACE WATER FLOW DIRECTION STREAM — — — STREAM THROUGH REINFORCED CONCRETE PIPE — Sandy Grave NOTES: - �r 1. ALL BOUNDARIESANDLOCATIONS ARE APPROXIMATE. �— 2_ INSET SCALE: 1IN = 30OFT - n + - 3_ PROPERTY BOUNDARY DERIVED FROM PRELIMINARY PLAT FOR THE FORMER PORCELANITE FACILITY CREATED BY C_E_ ROBERTSON & ASSOCIATES, PC. ON - JANUARY 12, 2022_ 4_ STREAM DATA WITHIN INSET OBTAINED FROM CITY OF LEXINGTON ARCGIS PORTAL, UPDATED JAN UARY 23, 2020. a - 5 �, �F- ^t"•'�� �,=f ;;� 5_ TOPOGRAPHIC MAP PROVIDED BY ESRI, LAST UPDATED AUGUST 2021 _ - 6_ AERIAL PHOTOGRAPHY OBTAINED FROM NORTH CAROLINA ONE MAP, COLLECTED FEBRUARY 3, 2018. 7. DRAWING HAS BEEN SET WITH A PROJECTION OF NORTH CAROLINA STATE PLANE __ _-. COORDI NATE SYSTEM FIPS 32DD (NAD83}_ r- . r� ! �. pry f.L�t _ _ _ _ �! _ _ _. - !1 ..,.4ac _rfs - GRAPHIC SCALE r 1,000 0 1,000 2,000 FIGURE 1 (IN FEEr) SITE TOPOGRAPHIC MAP 5 ! '- 1111111VW. CC. WYATT DATE ATT DATE: 1E/ 1111s FORMER PORCELANITE FACILITY CHECKED Br. M.FUNCHOM DATE06/09/2023 LEXINGTON, NORTH CAROLINA � � APPROVED BY: T. 011NHAM DATE" 06/09/2023 Term PROJECTMANAGER: T DLINHAM www.synterracorp.com METALS KEY: Ba - BARIUM B - BORON Cd - CADMIUM Co - COBALT Pb - LEAD V - VANADIUM Zn - ZINC J!, t MW-i 0 � B�n MW-14—.�—,— B, Pb s I 41 U a m Q OFF -SITE MONITORING WELL LOCATIONS SUBJECT TO CHANGE BASED ON PERMISSION TO ACCESS PROPOSED LOCATIONS. '.. 2 IUD _4 " i N OR: 1 5 LptlNGTO ., . Y a+ # J ! MW-19D MW-25 #B B, V MW-1 S f MW-28D B MW-12 MW-9D B , Zn MW-26-A-2 B, BA, Ccf, CD Pb Zn - p ' h. MW-13� MW 3A j % MW-2iA `� ,T P� T Mw 22A - - -- -- Lr - ` 1- 1 B Pb r r MW-7A c' MW-23A B' Co --- "J ..,..r.,e zT "Cl DR 5T. c 1�vlp synTerra n 0 0 :Z <p :m m �o Z'� �§ — o „N MW-26-A-2 , B, BA, Cd, i max_ x \ Co, Pb, Zn s s ��x MW-13 MW-3A y • B R xAygIi9YT P.&vy \ w a r '� '_aen \ Sf01iM p] . -. M-a1'35-w .. Y.Lo . T _ Z Z MW-29 LEGEND EXISTING MONITORING WELL J3 6 _ PROPOSED SHALLOW MONITORING WELL rY. ;mod • PROPOSED DEEP MONITORING WELL POTENTIAL BACKGROUND/HORIZONTAL DELINEATION MONITORING WELL -- - - —� — C POTENTIAL PHASE II MONITORING WELL A ' SURFACE WATER FLOW DIRECTION - STREAM *:p a3} STREAM THROUGH REINFORCED CONCRETE PIPE -_ NOTES: F EXISTING MONITORING WELL 1- SUPERIMPOSED SURVEY OUTLINEAND DETAILS DERIVED FROM PRELIMINARY PLAT • yp A FOR THE FORMER PORCELANITE FACILITY CREATED BY C-E ROBERTSON 8; ASSOCIATES, PC. CREATED JANUARY 12, 2022. � 2. ALL BOUNDARIES AND LOCATIONS ARE APPROXIMATE. 3. STREAM DATA OBTAINED FROM CITY OF LEXINGTON ARCGIS PORTAL, UPDATED JANUARY 23, 2020. ° 4 AERIAL PHOTOGRAPHY OBTAINED FROM NORTH CAROLINA ONE MAP, COLLECTED - FEBRUARY 3, 2018 5. DRAWING HAS BEEN SET WITH A PROJECTION OF NORTH CAROLINA STATE PLANE T - COORDINATE SYSTEM LIPS 3200 (NAD83). GRAPHIC SCALE 90 0 90 180 (IN FEET) DRAWN BY: C. WYATT DATE07/2V2022 REVISED BY: L. FOREMAN DATE' 06/12/2023 CHECKED By MCROBERTS DATES 06/12/2023 APPROVED BK T. DUNHAM DATES 06/12/2023 PROJECT MANAGER. T_ DUNHAM FIGURE 13 PROPOSED MONITORING WELL LOCATIONS FORMER PORCELANITE FACILITY LEXINGTON, NORTH CAROLINA