HomeMy WebLinkAboutWM0401482_Application_20231004NORTH CAROLINA DEPARTMENT OF ENVIRONMENTAL QUALITY - DIVISION OF WATER RESOURCES
APPLICATION FOR PERMIT TO CONSTRUCT A MONITORING OR RECOVERY WELL SYSTEM
PLEASE TYPE OR PRINT CLEARLY
In accordance with the provisions of Article 7, Chapter 87, General Statutes of North Carolina and regulations pursuant thereto,
application is hereby made for a permit to construct monitoring or recovery wells.
1. Date: 09/05/2023
2. County: Davidson
FOR OFFICE USE ONLY
PERMIT NO. ISSUED DATE
3. What type of well are you applying for? (monitoring or recovery): Monitoring
4. Applicant: Mannington Mills. Inc. Telephone: 856.339.5871
Applicant's Mailing Address: 75 Mannington Mills Road, Salem NJ 08079
Applicant's Email Address (if available): da✓c.kitts cumannington.com
5. Contact Person (if different than Applicant): Tom Dunham, SynTerra Corp Telephone: 919-632-3465
Contact Person's Mailing Address: SynTerra Corp., 511-102 Keisler Dr. Cary, NC 27518
Contact Person's Email Address (if available): tdunhamia�svntarracorp.coin
6. Property Owner (if different than Applicant): Condumex Inc. Telephone: 972-352-2340
Property Owner's Mailing Address: 900 Avenue S Grand Prairie Texas 75050
Property Owner's Email Address (if available): alex@condumex.com
7. Property Physical Address (Including PIN Number) 6 Edna Street (6724-02-56-0494)
City Lexington County Davidson Zip Code 27292
8. Reason for Well(s): groundwater assessment
(ex: non -discharge permit requirements, suspected contamination, assessment, groundwater contamination, remediation, etc.)
9. Type of facility or site for which the well(s) is(are) needed: RCRA
(ex: non -discharge facility, waste disposal site, landfill, UST, etc.)
10. Are there any current water quality permits or incidents associated with this facility or site? If so, list permit and/or incident no(s).
Hazardous Waste Management Permit, Permit No. NCD 986 181 451
11. Type of contaminants being monitored or recovered: metals
(ex: organics, nutrients, heavy metals, etc.)
12. Are there any existing wells associated with the proposed well(s)? If yes, how many? Yes 19
Existing Monitoring or Recovery Well Construction Permit No(s).: unknown
13. Distance from proposed well(s) to nearest known waste or pollution source (in feet): 250 feet
14. Are there any water supply wells located less than 500 feet from the proposed well(s)? no
If yes, give distance(s):
15. Well Contractor: Geologic Exploration, Brian Thomas Certification No.: NCWC 2581-A
Well Contractor Address: 176 Commerce Blvd Statesville NC 28625
PROPOSED WELL CONSTRUCTION INFORMATION
1. As required by 15A NCAC 02C .0105(f)(7), attach a well construction diagram of each well showing the following:
a. Borehole and well diameter e. Type of casing material and thickness
b. Estimated well depth f. Grout horizons
C. Screen intervals g. Well head completion details
d. Sand/gravel pack intervals
Continued on Reverse
PROPOSED WELL CONSTRUCTION INFORMATION (Carrtinued)
Number of weiis to be constructed in unconsolidated 5. How will the well(s) be secured? Protective steel
material 3 rasing with pad
Number of wells to be constructed in bedrock L___
Total Number of wells to be constructed 4
(add answors from 2 and 3)
Estimated beginning construction date 9-3,-1-23
Estimated construction Completion date. 9 97 233
ADDITIONAL INFORMATION
As required by 15A NCAC 02C .0105(f)(5), attach a scaled map of the site showing the tocalions of the following
a. All property boundaries, at least one of which is referenced to a minimum of two landmarks such as identified roads,
intersections, streams, or lakes within 500 feet of the proposed well or well system
b. All existing wells, identified by type of use, within 500 feet of the proposed well or well system
c The proposed well or well system
d. Any test borings within 500 feet of proposed well or well system
e All sources of known or potential groundwater contamination (such as septic tank systems, pesticide, chemical or fuel
storage areas, animal feedtats as defined in G S. 143.215.108(5), landfills, or other waste disposal areas) within 500 feet
of the proposed well or well system
SIGNATURES
The Applicant assumes total 7pnibilky for ensuring that the well(s) will be located, constructed, maintained, and abandoned in
accordance with 15A NCAC 02C
l s 1 C ^�a�
Si ature of Applicant or 'Agent Title df Applica oi'Agent
U { ' if signing as Agent, attach authohzarron agreement staling
Prin ed name of Applicant or Agent that you have the authority to act as the Agent.
11 the property is owned by someone other than the Applicant, the property owner hereby consents to allow the Applicant to construct
well(s) as outline in this Well Construction Permit application and acknowledges that it shall be the responsibility of the Applicant to
ensure t well(,) will be located, constructed, maintained, and a on in accordance with i5A NCAC 02C,
4n z -
Signature of Pr arty wrier (if different than Applicant) Pri ted name of Property Owner ( -different than Applicant)
DIRECTIONS
Please sC7nd the completed application to the appropriate Division of Water Resources' Regional Office -
Asheville Regional Office Raleigh Regional Office Wilmington Regional Office
2090 US Highway 70 3800 Barreft Drive 127 Cardinal Dine Extension
Swannanoa, NC 28778 Raleigh, NC 27609 Wilmington, NO 28405
Phone (828) 296.4500 Phone: (919) 791-4200 Phone (910) 796-7215
Fax: (628) 299-7043 Fax (919) 571-4718 Fax (910) 350-2004
Fayetteville Regional Office
226 Green Street, Suite 714
Fayetleville, NO 28301-5094
Phone (910) 433-3300
Fax: (910) 486-0707
Mooresville Regional Office
610 East Center Avenue
Mooresville, NC 28115
Phone. (704) 663-1699
Fax: (704) 663-6040
Washington Regional Office
943 Washington Square Mall
Washington, NC 27889
Phone: (252) 946-6481
Fax. (252) 975-3718
Wlnston•Salem Regional Office
450 W Hanes Mill Road
Suite 300
Winston-Salem, NO 27105
Phone: (336) 776-9800
Fax- (336) 776-9797
GW-2ZMIR (Rav 5.2&20221
Locking Well Cap
Upright Protective
Cover with Lock
Land Surface
3' Radius or 4' by 4' Concrete Pad
6" Borehole Diameter
(Nominal Dimension)
Cement Grout
2" Schedule 40 PVC Casing
w/ Threaded Couplings
Approximate 2'
Bentonite Seal
v
c
O
fV
N
O
>
Well Sorted
Sand Pack
v
v
♦� Water Table
10' Screened Interval
v
0.010" Slotted Screen
o
2" Schedule 40 PVC
fV
m
Sump/Sediment Trap
Bottom Cap
Estimate Depth = 40'
148 RIVER STREET, SUITE 220
GREENVILLE, SOUTH CAROLINA 29601
PHONE (864) 421-9999
FIGURE 3
HTTP://W W W.SYNTERRACORP.COM
GENERALIZED MONITORING WELL SCHEMATIC
synTerra
ov
-
_� I6b
♦ .
FEDERAL
O
e
_VC,F 13
r
' Meadovavieva - �.S;I' - I • i
Lexlnytor)
9
���IA1 p4 a'11
--
�AROM,., ;r LEGEND
_ r PROPERTY BOUNDARY
SURFACE WATER FLOW DIRECTION
STREAM
— — — STREAM THROUGH REINFORCED CONCRETE PIPE
— Sandy
Grave NOTES:
-
�r 1. ALL BOUNDARIESANDLOCATIONS ARE APPROXIMATE.
�— 2_ INSET SCALE: 1IN = 30OFT
- n
+ - 3_ PROPERTY BOUNDARY DERIVED FROM PRELIMINARY PLAT FOR THE FORMER
PORCELANITE FACILITY CREATED BY C_E_ ROBERTSON & ASSOCIATES, PC. ON
- JANUARY 12, 2022_
4_ STREAM DATA WITHIN INSET OBTAINED FROM CITY OF LEXINGTON ARCGIS PORTAL,
UPDATED JAN UARY 23, 2020.
a
- 5 �, �F- ^t"•'�� �,=f ;;� 5_ TOPOGRAPHIC MAP PROVIDED BY ESRI, LAST UPDATED AUGUST 2021 _
- 6_ AERIAL PHOTOGRAPHY OBTAINED FROM NORTH CAROLINA ONE MAP, COLLECTED
FEBRUARY 3, 2018.
7. DRAWING HAS BEEN SET WITH A PROJECTION OF NORTH CAROLINA STATE PLANE
__ _-. COORDI NATE SYSTEM FIPS 32DD (NAD83}_
r-
. r� ! �. pry f.L�t _ _ _ _ �! _ _ _.
- !1 ..,.4ac _rfs - GRAPHIC SCALE
r 1,000 0 1,000 2,000
FIGURE 1
(IN FEEr)
SITE TOPOGRAPHIC MAP
5 ! '- 1111111VW. CC. WYATT DATE ATT DATE: 1E/ 1111s FORMER PORCELANITE FACILITY
CHECKED Br. M.FUNCHOM DATE06/09/2023 LEXINGTON, NORTH CAROLINA
� � APPROVED BY: T. 011NHAM DATE" 06/09/2023
Term PROJECTMANAGER: T DLINHAM
www.synterracorp.com
METALS KEY:
Ba
- BARIUM
B -
BORON
Cd
- CADMIUM
Co
- COBALT
Pb
- LEAD
V -
VANADIUM
Zn
- ZINC
J!,
t MW-i 0 �
B�n
MW-14—.�—,—
B, Pb
s
I 41
U
a
m
Q
OFF -SITE MONITORING WELL LOCATIONS
SUBJECT TO CHANGE BASED ON PERMISSION
TO ACCESS PROPOSED LOCATIONS.
'..
2
IUD
_4 " i
N OR:
1
5 LptlNGTO ., .
Y a+ # J !
MW-19D
MW-25
#B B, V
MW-1 S
f
MW-28D
B
MW-12 MW-9D
B , Zn
MW-26-A-2
B, BA, Ccf,
CD Pb Zn -
p ' h.
MW-13� MW 3A
j % MW-2iA
`�
,T P� T Mw 22A - - -- --
Lr - ` 1- 1 B Pb r
r MW-7A
c'
MW-23A
B' Co ---
"J ..,..r.,e zT "Cl DR 5T.
c
1�vlp
synTerra
n
0
0
:Z
<p
:m
m
�o
Z'� �§ —
o „N MW-26-A-2 ,
B, BA, Cd,
i
max_
x \ Co, Pb, Zn s
s ��x
MW-13
MW-3A
y
•
B
R
xAygIi9YT
P.&vy
\ w
a r '�
'_aen
\
Sf01iM p]
. -.
M-a1'35-w
.. Y.Lo .
T _ Z Z
MW-29
LEGEND
EXISTING MONITORING WELL
J3 6
_ PROPOSED SHALLOW MONITORING WELL
rY.
;mod
• PROPOSED DEEP MONITORING WELL
POTENTIAL BACKGROUND/HORIZONTAL
DELINEATION MONITORING WELL
-- - - —�
—
C POTENTIAL PHASE II MONITORING WELL
A '
SURFACE WATER FLOW DIRECTION
- STREAM
*:p a3}
STREAM THROUGH REINFORCED CONCRETE PIPE
-_
NOTES:
F EXISTING MONITORING WELL
1- SUPERIMPOSED SURVEY OUTLINEAND DETAILS DERIVED FROM PRELIMINARY PLAT
• yp
A
FOR THE FORMER PORCELANITE FACILITY CREATED BY C-E ROBERTSON 8; ASSOCIATES,
PC. CREATED JANUARY 12, 2022.
�
2. ALL BOUNDARIES AND LOCATIONS ARE APPROXIMATE.
3. STREAM DATA OBTAINED FROM CITY OF LEXINGTON ARCGIS PORTAL, UPDATED
JANUARY 23, 2020.
°
4 AERIAL PHOTOGRAPHY OBTAINED FROM NORTH CAROLINA ONE MAP, COLLECTED
-
FEBRUARY 3, 2018
5. DRAWING HAS BEEN SET WITH A PROJECTION OF NORTH CAROLINA STATE PLANE
T -
COORDINATE SYSTEM LIPS 3200 (NAD83).
GRAPHIC SCALE
90 0 90 180
(IN FEET)
DRAWN BY: C. WYATT DATE07/2V2022
REVISED BY: L. FOREMAN DATE' 06/12/2023
CHECKED By MCROBERTS DATES 06/12/2023
APPROVED BK T. DUNHAM DATES 06/12/2023
PROJECT MANAGER. T_ DUNHAM
FIGURE 13
PROPOSED MONITORING WELL LOCATIONS
FORMER PORCELANITE FACILITY
LEXINGTON, NORTH CAROLINA