Loading...
HomeMy WebLinkAboutNC0067326_Fact Sheet_20231005NCDEQ / DWR / NPDES EXPEDITED FACT SHEET - NPDES PERMIT RENEWAL NPDES Permit NC0067326 Sara Bassett / Compliance & Expedited Permitting Unit / sara.bassett@deq.nc.gov / September 2023 FACILITY INFORMATION Applicant/Facility Name Country Bear LLC, Whistle Stop WWTP Applicant Address Applicant address same as physical address Facility Physical Address/Mailing Address 145 River Road, Franklin NC Permitted Flow (MGD) 0.003 MGD Type of Waste 100% Domestic, < 1 MGD Facility Class WW-2 County Macon Permit Status Renewal Regional Office ARO STREAM CHARACTERISTICS Receiving Stream Cullasaja River Stream Classification B; Tr Stream Segment 2-21-(5.5) Outfall Lat. 35.1611N 7Q10 - Summer (cfs) 36.6 Outfall Long. 83.3147W 7Q10 - Winter (cfs) 45.4 Drainage basin Little Tennessee 30Q2 (cfs) ~ Subbasin 04-04-01 Average Flow (cfs) 223 HUC 60102020203 IWC (%) 303(d) List No BASIC INFO FOR EXPEDITED PERMIT RENEWAL Does permit need Daily Max NH3 limits? No-massive dilution at discharge point Does permit need TRC limits/footnote? Already present in permit. Does permit have toxicity testing? No – not a complex wastestream Does permit have any Special Conditions? No Does permit have instream monitoring? Added for temperature for trout waters New expiration date: November 30, 2028 1. FACILITY SUMMARY Country Bear LLC sends 100% domestic discharge to Whistle Stop WWTP. The Whistle Stop WWTP is a minor facility (flow < 1 MGD) with a design capacity and permitted wastewater discharge of 0.003 MGD facility that includes the following components: ♦ 2000-gallon primary clarifier tank ♦ Flow equalization ♦ 2000-gallon Aero-Flow aerobic system ♦ 580-ft2 sand filter ♦ 1200-gallon chlorine chamber ♦ 600-gallon polishing tank RENEWAL SUMMARY This renewal contains the following changes: • Updated the effluent table in Section A. (1.) with eDMR parameter codes. • Added effluent monitoring for turbidity to the table in Section A. (1.) to determine compliance with 15A NCAC 02B.0211 (21) for Trout waters. • Added effluent monitoring for dissolved oxygen to the table in Section A. (1.) to determine compliance with 15A NCAC 02B.0211 (6) for Trout waters. • Added instream monitoring for temperature to the table in Section A. (1.) to determine compliance with 15A NCAC 02B.0211 (18) for Trout waters. • Updated Section A. (2) to reflect current federal requirements for Electronic Reporting of Discharge Monitoring Reports. COMPLIANCE HISTORY Two enforcements in 2022 for limit violations. COMMENTS ON DRAFT PERMIT