Loading...
HomeMy WebLinkAboutNC0085294_Permit Modification_20180907ROY COOPER Governor MICHAEL S. REGAN Secretary LINDA CULPEPPER Interim Director NORTH CAROLINA Environmental Quality September 7, 2018 Ms. Tara Hamlin Pavillon International P.O. Box 189 Mill Springs, NC 28756-0189 Subject: Minor modification of NPDES Permit NCO085294 Britten Creek WWTP Polk County Grade II Biological WPCS Dear Ms. Hamlin: The Division has received and reviewed your request to modify the subject permit. The Division does not object to your request. This modification is issued pursuant to the requirements of North Carolina General Statute 143-215.1 and the Memorandum of Agreement between North Carolina and the U.S. Environmental Protection Agency dated October 15, 2007 (or as subsequently amended). Insert the attached pages into your permit and discard the old pages. This modified permit includes the following changes from your current permit: ➢ The facility component list has been updated. ➢ Monitoring frequencies have been updated in Section A. (1.) for all parameters except Ammonia Nitrogen, due to the current facility classification per 15A NCAC 02B .0508. If any parts, measurement frequencies or sampling requirements contained in this modification are unacceptable to you, you have the right to an adjudicatory hearing upon written request within thirty (30) days following receipt of this letter. This request must be in the form of a written petition, conforming to Chapter 150B of the North Carolina General Statutes, and filed with the Office of Administrative Hearings (6714 Mail Service Center, Raleigh, North Carolina 27699-6714). Unless such demand is made, this decision shall be final and binding. This permit is not transferable except after notice to the Division. The Division may require modification or revocation and reissuance of the permit. This permit does not affect the legal requirements to obtain other permits which may be required by any other Federal, State, or Local governmental regulation. If you have any questions concerning this matter, please contact Emily Phillips at (919) 707-3621 or via e-mail [emily.phillips@ncdenr.gov]. erely��� eL Linda Culpepper Interim Director, Division of Water Resources cc: Central Files,. NPDES Unit State of North Carolina I Environmental Quality I Water Resources 1617 Mail Service Center I Raleigh, NC 27699-1617 919 807 6300 919-801-6389 FAX https://deq.nc.gov/about(divisions/water-mources/water-resources-pemiitstwastewater-branch/npdes-wastewater-permits Permit NCO085294 Grade II Biological Water Pollution Control System [ 15A NCAAC 08G .0302] Part I. A. (I.) EFFLUENT LIMITATIONS AND MONITORING REQUIREMENTS [ 15A NCAC 02B .0400 et seq., 02B .0500 et seq.] During the period beginning on the effective date of this permit and lasting until expiration, the Permittee is authorized to discharge from outfall 001. Such discharges shall be limited and monitored2 by the Permittee as specified below: LIMITS � Y l 0{�ITORINC R QVft ENTS `EFFLUENT CHARAC�'fRISTICS.. -= x�_; ; _ Monthly ' - ° a Dail ..Measurer ient Sari Ip e r Sample Pararefer Code: ;lvera e_ ..j.Location_ Flow 0.00586 MGD Weekly Instantaneous Influent or Effluent 50050 BOD, 5-day (20°C) 30.0 mg/L 45.0 mg/L Weekly Grab Effluent C0310 Total Suspended Solids' 30.0 mg/L 45.0 mg/L Weekly Grab Effluent C0530 NH3 as N Monthly Grab Effluent C0610 Fecal Coliform (geometric mean) 200/100 ml 400/100 ml Weekly Grab Effluent 31616 Total Residual Chlorine (TRC) 28 Ng/L Weekly Grab Effluent 50060 Temperature (°C) Weekly Grab Effluent 00010 pH Not < 6.0 nor > 9.0 Weekly Grab Effluent 00400 Standard Units Footnote: 1. The Division shall consider all effluent TRC values reported below 50 µg/L to be in compliance with the permit. However, the Permittee shall continue to record and submit all values reported by a North Carolina certified laboratory (including field certified), even if these values fall below 50 µg/L. 2. The Permittee shall submit discharge monitoring reports electronically using the Division's eDMR system [see A. (3.)]. THERE SHALL BE NO DISCHARGE OF FLOATING SOLIDS OR VISIBLE FOAM IN OTHER THAN TRACE AMOUNTS Page 3 of 6 Phillips, Emily From: Willmer, Mikal Sent: Wednesday, August 15, 2018 4:43 PM To: Phillips, Emily Cc: Davidson, Landon Subject: Lynnbrook (NC0071005) & Pavilion (NC0085294) Monitoring Frequencies Follow Up Flag: Follow up Flag Status: Flagged Hey Emily, Thanks for the call today. For these two facilities we are just trying to get monitoring frequencies in line with a Class II facility. They are both currently sampling under frequencies for a Class I facility. Under 0213, Minimum Monitoring Requirements for Domestic Wastewater and Other Facilities Discharging Primarily Domestic Wastewater the following frequencies are listed; DOMESTIC WASTEWATER AND OTHER FACILITIES DISCHARGING PRIMARILY DOMESTIC MINIMUM REQUIREMENTS FOR SIC 4953 EFFLUENT LU41TED REQUIRED TEST LOCATION FREQUENCY CLASS CLASS CLASS CLASS I 11 IH IV PH E 2-month Weekly 3 week Daily Temperamm.'C E Weekly Weekly 3'u'oek Daily BOD. 5.day, 2WC LE 2'mooth Weekly 3 week Daily TSS LE 2'month Weekly 3 wcck Daily Ammonia Nitrogen E Monthly 2'month Wcckly 3 week Fecal Cohfomt E 2'month Weekly 3 week Daily Total Nitrogen E • • ' ' Total Phosphoms E 4 Toxic% and Toxicity •• •• '• '• Lynnbrook and Pavilion are both Class II facilities in accordance with 08G.0302 classification (activated sludge facilities <0.5 MGD flow). I know the flows are low for both of these facilities; however, sometimes these are our most problematic facilities so I encourage we at least ask for the minimum sampling requirements for the assigned classification. This would increase BOD, TSS, Fecal and pH to weekly and NH3 to 2/month for both facilities. Additionally, Lynnbrook is only sampling temperature 2/month (normal monitoring is weekly for both Class I & 11). I am free discuss this Friday or next week, just let me know. Thanks! Mikal Willmer Environmental Specialist -Asheville Regional Office Water Quality Regional Operations Section NCDEQ-Division of Water Resources Office: 828-296-4686 Hennessy, John From: Davidson, Landon Sent: Wednesday, July 25, 2018 3:17 PM To: Hennessy, John Subject: ARO permit comments John, I hope you are doing well. I wanted to bring to your attention an issue where Mikal of my staff had provided permit review comments that were never incorporated into the permit nor an explanation provided as to why. The facilities are NC0085294 and NC0071005. Comments were provided by Mikal on May 15`^ related to the fact that NC0085294 had significant changes to treatment components (no longer a sand filter) and NC0071005 had monitoring listed for a Class I facility. Both these permits were issued on July 9" with no change. Please let me know what we can do to see that we have accurate permits and staff comments are either incorporated or staff receive a response as to why. Thanks. You can call me if you want to discuss. Landon G. Landon Davidson, P.G. Regional Supervisor — Asheville Regional Office Water Quality Regional Operations Section NCDEQ — Division of Water Resources 828 296 4680 office 828 230 4057 mobile Landon. Davidson(a) ncdenr. gov /77.0 It J{/m ':7 /t r'-� PalAw��C 2090 U.S. Hwy. 70 Swannanoa, N.C. 28711 Email correspondence to and from this address is subject to the North Carolina Public Records Law and may be disclosed to third parties. NCDENR North Carolina Department of Environment and Natural Resources Pat McCrory Governor July 6, 2015 Ms. Anne Vance Pavilion International P.O. Box 189 Mill Spring, NC 28756-0189 Subject: Classification of Water Pollution Control System Pavilion International — Britten Creek WWTP NCO085294 — Polk County Dear Ms. Vance: Donald R. van der Vaart Secretary In accordance with North Carolina General Statute § 90A-37, the Water Pollution Control System Operators Certification Commission is required to classify all water pollution control systems. The Commission has determined that the subject facility is classified as a Grade 2 Biological Water Pollution Control Treatment System, based upon an upgrade of the facilities to an extended aeration activated sludge process which was authorized in late 2013 and is now operational. As required by 15A NCAC SG .0201 (1) and (2) and your permit, you must designate a Grade 2 or higher Biological Operator in Responsible Charge (ORC) and a Back-up Operator with at least a Grade 1 Biological certification. Please complete and return the enclosed ORC Designation Form. within 120 days, to this office via USPS or email to certadmin@ncdenr.gov. If you have questions concerning this classification or the designation of operators, please contact me at 919.707.9108, or via email at steve.reid@ncdenr.gov. Sincerely, Supervisor NC Operator Certification Program Cc: Asheville Regional Office - email File 1601 Mail Service Center, Raleigh, North Carolina 27699-1601 Phone: 919-707.86001 Internet: www.nodenr.gov An Equal Opportunity 1 Affirmative Action Employer — Made In pat by recycled paper