HomeMy WebLinkAboutWI0700473_Monitoring (Report)_20231002DocuSign Envelope ID: OFA29946-CDAA-4438-BB94-651664F72830 ROY COOPER Governor ELIZABETH S. BISER Srrretary RICHARD E. ROGERS. JR. Director Michael Colson and Gail Dickinson 120 Dogwood Drive Camden, North Carolina 27921 NORTH CAROLINA Environmental Quality October 2, 2023 SUBJECT: Groundwater Sampling Results UIC Permit No. W10700473 Issued to Michael Colson and Gail Dickinson Camden, Camden County, North Carolina Dear Mr. Colson and Ms. Dickinson: Staff from the Washington Regional Office of the Water Quality Regional Operations Section collected samples of the influent (supply well) and effluent (injection well) from your geothermal heat pump system on August 28, 2023. The samples were analyzed for metals, nutrients, and other inorganic constituents by the Division of Water Resources laboratory. A summary table of the analytical results, as well as the laboratory reports, field sampling forms, and definitions of laboratory data qualifiers are attached to this letter. The following constituents were detected above state groundwater standards in both samples from your system: Parameter Units NC Results Groundwater Standard Total Coliform Colony Forming Units 1 30 (supply well -influent) per 100 milliliters 160 (injection well -effluent) (CFU/100ml) Fecal Coliform Colony Forming Units 1 3 (supply well -influent) per 100 milliliters 2 (injection well -effluent) (CFU/100ml) Iron Micrograms per Liter 300 370 (supply well -influent) (ug/L) <50 (injection well -effluent) Manganese Micrograms per Liter 50 100 (supply well -influent) (ug/L) 94 (injection well -effluent) pH Standard Units (s.u.) 6.5 to 8.5 5.5 (supply well -influent) 5.5 (injection well -effluent) These exceedances should not affect the use of the wells for your geothermal heat pump system; however, it is recommended before using the water from these wells for personal consumption that you consult with Albemarle Regional Health Services (local health agency). Nonh Carolina Depanmenl of Environmental Quality Division of Water Resources Washington Regional Office - 943 Washington Square Mal - Washington, Noah Carolina, 27889 �/ 252-9.46-6l8l DocuSign Envelope ID: OFA29946-CDAA-4438-BB94-651664F72830 Michael Colson and Gail Dickinson October 2, 2023 Page 2 of 2 If you have any questions regarding the sampling results or your permit, please feel free to contact me at (252) 948-3849. Sincerely, D'Al R"'(Y 5-44 Dwight Randy Sipe, P.G., Hydrogeologist Water Quality Regional Operations Section Division of Water Resources, NCDEQ Attachments cc: Blake Butcher —DWR Groundwater Resources Section (electronic copy) Laserfiche North Caroline Department o f En,,.o,rcrt.l Quality Division of Walet Resources �}} Washngton Regional Office - 943 Washington Square Man - Washington, North Caroline. 27899 252 946-6481 k ! C) ] @ ow of o )wglf§ !(§BAG \z(D0m <zz=G b(;§§/ q%ƒ®®o /(/®\) \w) \) ) /a, , �f !ram \k§§§v ke,l,0 VV E j\\Z GG )a# \k�\v `ZE + „ , }E ) k§ ! -E\ ) }} k k§ ' � u � � o N ' N � 1 1 c m 1 ' C N ys 0 3 E 1 cs y� yy rr c Weo \ H x a I c N o� E � W � V e 3 DO , c 0 w V V U U U V U u w W $ m \ = E � e A N &. m ° > °' E 6gq5 m E i� z - m E W N N V N 6' s E P Q c o s E W � v n U ¢ ¢` Ri Imo 6_ v i o a x a p s p• a ¢ a a a a a a¢ a a a a a¢ v ° a g � o $z � a .L x � L OV Zi' x p c VJj «' mE U LL N U V V C K C 6 K N F M u E 15 LA yy °s ' m Q x v o anSK LL O y AD13588 North Carolina Division of Water Resources Water Sciences Section Laboratory Results Loc. Descr.: County: Region: River Basin Emergency COC Yes/No W10700473 Camden Collector RSIPE T VisitlD Washington Report To WARD Location In: WARD NLC Collect Date' 08/28/2023 Priority COMPLIANCE Collect Time 10_16 Sample Matrix. GROUNDWATER Sample Depth Loc. Type: Other: Geotherm Supply Sample ID: AD13588 PO Number# Date Received. 08/29/2023 Time Received'. 07:00 Labworks LoginlD TASCENZ01 Delivery Method No Courier Final Report Dale: 9130/23 Report Print Date: 09/30/2023 If this report is labeled preliminary report, the results have not been validated. Result/ CAS # Analvte Name PQL Qualifier LAB Sample temperature at receipt by lab 2.0 Do not use for Regulatory purposes. Method Analysis Units Reference Date °c 8/29/23 validated by MSWIFT Coliform, MF Fecal in liquid 1 MIC 301 CFU/100m1 SM 9222 D-1997 8/29/23 JJURGEVICH Coliform, MF Total in liquid 1 30 Q1 Cl SM 9222 B-1997 8/29/23 JJURGEVICH 14797-65-0 Nitrite as N in liquid 0.02 NUT 0.02 U mg/L as N EPA 353.2 REV 2 8/29/23 ALWILLIAMS E701177 NO2+NO3 as N in liquid 0,30 4.4 P ml as N EPA 353.2 REV 2 9f7/23 ALWILLIAMS 24959-67-9 Bromide 0A WET 0.4U mg/L EPA 3000 rev21 9/6/23 ALWILLIAMS 16887-00-6 Chloride 2.0 60P mg/L EPA 3000 rev2.1 9/6/23 ALWILLIAMS 16984-48-8 Fluoride 0.4 0.4U mg/L EPA 300.0 rev2.1 9/6/23 ALWILLIAMS 14808-79-8 Sulfate 2.0 18 mg/L EPA 300.0 rev21 916/23 ALWILLIAMS Total Dissolved Solids in liquid 12.5 226 mg/L SM 2540 C-1997 8/29123 ALWILLIAMS 7429-90-5 Al by ICP 50 MET 50 U ug/L EPA 200.7 Rev44 9/5123 JJURGEVICH 7440-38-2 AS by ICPMS 2.0 2.0U ug/L EPA 200.8 Rev5.4 9/14123 JJURGEVICH 7440-70-2 Ca by ICP 0,10 14 mg/L EPA 2007 Rev44 9/5/23 JJURGEVICH 7440-47-3 Cr by ICPMS 5.0 5.0 U ug/L EPA 200.8 Rev5.4 9/14/23 JJURGEVICH 7440-50-8 Cu by ICPMS 2.0 23 ug/L EPA 200.8 Rev5.4 9/14/23 JJURGEVICH 7439-89-6 Fe by ICP 50 370 ug/L EPA 200.7 Rev4.4 9/5/23 JJURGEVICH 7440-09-7 K by ICP 0.10 2.4 ml EPA 200.7 Rev4.4 9/5/23 JJURGEVICH 7439-95-4 Mg by ICP 0,10 6.4 mg/L EPA 200.7 Rev44 9/5123 JJURGEVICH 7439-96-5 Mn by ICP 10 100 ug/L EPA 200.7 Rev4.4 9/5/23 JJURGEVICH 7440-23-5 Na by ICP 0.2 37P mg/L EPA 2007 Rev44 9/5/23 JJURGEVICH 7440-02-0. Ni by ICPMS 2.0 6.9 ug/L EPA 200.8 Rev5.4 9/14/23 JJURGEVICH 7439-92-1 Pb by ICPMS 2.0 5.2 ug/L EPA 200.8 Rev54 9/14123 JJURGEVICH 7440-66-6 Zn by ICPMS 10 46 ug/L EPA 200.8 Rev5.4 9/18123 JJURGEVICH WSS Chemistry Laboratory>> 1623 Mail Service Center, Raleigh, NC 27699.1623 (919) 733-3908 "Not Detected" or"U" does not indicate the sample is analyle free but that the analyte is not detected at or above the PQL Page 1 of 3 NCIDWX La6oratory Section 9RS=Its/Sample Comments/Qualifier(Definitions Sample IDAD13688 Result/ Method Analysis Qualifier Units Reference Date Validated by Sample Comments MIC'. Fecal Coliform-ol-Sample exceeded holding time prior to receipt at lab. NCDEQ-WSS-Chemistry Lab Data Qualifiers Al The reported value is an average, whereat least one result is qualified with a "U". The PQL is used for the qualified result(S) to cal, B1 Coliform-Countable membranes with less than 20 colonies. Reported value is estimated or is a total of the counts on all filters repor B2 Coliform-Counts from all filters were zero. B3 Coliform-Countable membranes with more than 60 or 80 colonies. The value reported is calculated using the count from the smalle: B4 Coliform-Filters have counts of both >60 or 80 and <20. Reported value is estimated or is a total of the counts on all filters reported B5 Coliform-Too many colonies were present, too numerous to count (TNTC). TNTC is generally defined as >150 colonies. 86 Coliform-Estimated Value. Blank contamination evident. B7 Coliform-Many non-coliform or non-enterococcus colonies or interfering non-coliform or non-enterococcus growth present. In this c< BB1 MPN-No wells or tubes gave a positive reaction. Value based upon the appropriate MPN Index and reported as a less than "<" valu BB2 MPN-All wells or tubes gave positive reactions. Value based upon the MPN Index and reported as a greater than 5" value. C Total residual chlorine was present in sample upon receipt in the laboratory. value is estimated. G1 BOD-The dissolved oxygen (DO) depletion of the dilution water blank exceeded 0.2 mg/L. G2 BOD-The bacterial seed controls did not meet the requirement of a DO depletion of at least 2.0 mg/L and/or a DO residual of at lea', G3 BOD-No sample dilution met the requirement of a DO depletion of at least 2.0 mg/L and/or a DO residual of at least 1.0 mg/L. G4 BCD -Evidence of toxicity. This is generally characterized by a significant increase in the BOD value as the sample concentration de G5 BOD-The glucose/ glutamic acid standard exceeded the range of 198 ± 30.5 mg/L. G7 BOD-Less than 1 mg/L DO remained for all dilutions set. The reported value is an estimated greater than value and is calculated fo G8 BOD-Oxygen usage is less than 2 mg/L for all dilutions set. The reported value is an estimated less than value and is calculated for G9 BOD-The DO depletion of the dilution water blank produced a negative value. it Surrogate recovery limits have been exceeded. J10 Unidentified peak, estimated value. WSS Chemistry Laboratory>> 1623 Mail service Center, Raleigh, INC 27699-1623 (919) 733-3908 "Not Detected" or 'U" does not indicate the sample is analyte free but that the analyte is not detected at or above the PDL. Page 2 of 3 NCVI,P f, LaboratorySection 9�Ssufta/Sample Core men ts/Quafifur (Definitions Sample ID: AD13588 -1. Result/ Method Analysis Ieuennei Units MUi Ui UIIG6 Uate VdiludLuu uv J11 The reported value is determined by a one -point estimation rather than against a regression equation. The estimated concentration J12 The calibration verification did not meet the calibration acceptance criterion for field parameters. J2 The reported value failed to meet the established quality control criteria for either precision or accuracy. J3 The sample matrix interfered with the ability to make any accurate determination. J4 The data is questionable because of improper laboratory or field protocols (e.g., composite sample was collected instead of grab, p J5 Temperature limits exceeded (samples frozen or >6'C) during transport or not verifiable (e.g., no temperature blank provided): non- J6 The laboratory analysis was from an unpreserved or improperly chemically preserved sample. The data may not be accurate. R This qualifier is used to identify analyte concentration exceeding the upper calibration range of the analytical instrument/method. Th J8 Temperature limits exceeded (samples frozen or>6°C) during storage, the data may not be accurate. A The reported value is determined by a one -point estimation rather than against a regression equation. The estimated concentration M Sample and duplicate results are but of control'. The sample is non -homogenous (e.g., VOA soil). The reported value is the lower, N1 Presumptive evidence and estimated value. The component has been tentatively identified base on mass spectral library. N2 There is an indication that the analyte is present, but quality control requirements for confirmation were not met (i.e., presence of N3 This code shall be used if the level is too low to permit accurate quantification, but the estimated concentration is less than the labo N4 This code shall be used if the level is too low to permit accurate quantification, but the estimated concentration is less than the labo N5 The component has been tentatively identified based on a retention time standard. P Elevated PQL' due to matrix interference and/or sample dilution. Q1 Holding time exceeded prior to receipt by lab. Q2 Holding time exceeded following receipt by lab. S Not enough sample provided to prepare and/or analyze a method -required matrix spike (MS) and/or matrix spike duplicate (MSD). U Indicates that the analyte was analyzed for but not detected above the reported practical quantitation limit*. The number value repo U, J6 The laboratory analysis was from an unpreserved or improperly chemically preserved sample. The data may not be accurate. UU Indicates that the analyte was not detected by a screen analysis. The number value was determined by a one -point estimation at It V Indicates the analyte was detected in both the sample and the associated method blank. Note: The value in the blank shall not be s X1 Sample not screened for this compound. X2 Sampled, but analysis lost or not performed -field error. X3 Sampled, but analysis lost or not performed -lab error. Y Elevated PQL` due to insufficient sample size. Zi Inability to analyze the sample. Z2 Questions concerning data reliability. J13 Standards used for this analyte are from an uncertified source. These are the only standards currently available for the analyte. WSS Chemistry Labomtory» 1623 Mail Service Center, Raleigh, NC 27699-1623 (919) 733-3908 "Not Detected" or"U" does not indicate the sample is analyte free but that the analyte is not detected at or above the PQL. Page 3 of 3 c �y m 3 i j q O � 8 „b O n a S C C AD13589 North Carolina Division of Water Resources Water Sciences Section Laboratory Results Loc. Descr.: W10700473 County. Camden Collector_ RSIPE r,[�' VisillD C lL (1•�E 1t Region'. Washington Report To WARO Location 10. WARO NLC River Basin Collect Date: 08/28/2023 Priority COMPLIANCE Emergency Collect Time'. 10_06 Sample Matrix'. GROUNDWATER COC Yes/No Sample Depth Loc. Type Other: Geotherrn Supply Final Report Sample ID. AD13589 PO Number # Date Received 08129/2023 Time Received: 07_00 Labworks LoginlD TASCENZ01 Delivery Method NC Courier Final Report Date. 9/30/23 Report Print Dale. 09/30/2023 If this report is labeled preliminary report, the results have not been validated. Result/Method CAS # Analyte Name PQL Qualifier LAB Sample temperature at receipt by lab 2.0 Do not use for Regulatory purposes. Analysis Units Reference Date °C 8129/23 Validated by MSWIFT COlifofm, MF Fecal in liquid 1 MIC 2 Q1 CFU/100m1 SM 9222 D-1997 8/29/23 JJURGEVICH Coliform, MF Total in liquid 1 160 Q1 CFU/100ml SM 9222 B-1997 8/29/23 JJURGEVICH 14797-65-0 Nitrite as N in liquid 0,02 NUT 0.02 U mg/L as N EPA 353.2 REV 2 8/29/23 ALWILLIAMS E701177 NO2+NO3 as N in liquid 0.30 4.8 P ri as N EPA 353.2 REV 2 917/23 ALWILLIAMS 24959-67-9 Bromide 0A WET 0.4 U mg/L EPA 300.0 rev2.1 9/6123 ALWILLIAMS 16887-00-6 Chloride 2.0 5o P mg/L EPA 300.0 rev2.1 9/6/23 ALWILLIAMS 16984-48-8 Fluoride 0.4 0.4U mg/L EPA 300.0 rev2.1 916/23 ALWILLIAMS 14808-79-8 Sulfate 2.0 18 mg/L EPA 300.0 rev2.1 9/6/23 ALWILLIAMS Total Dissolved Solids in liquid 12.5 219 mg/L SM 2540 C-1997 8/29/23 ALWILLIAMS 7429-90-5 Al by ICP 50 MET 5o U ug/L EPA 200.7 Rev4.4 9/5/23 JJURGEVICH 7440-38-2 As by ICPMS 2.0 2.0 U ug/L EPA 200.8 Rev54 9/14/23 JJURGEVICH 7440-70-2 Ca by ICP 0A0 14 mg/L EPA 200.7 Rev4.4 9/5/23 JJURGEVICH 7440-47-3 Cr by ICPMS 5.0 5.0 J ug/L EPA 200.8 Rev5.4 9/14/23 JJURGEVICH 7440-50-8 Cu by ICPMS 2.0 62 ug/L EPA 200.8 Rev5.4 9/14/23 JJURGEVICH 7439-89-6 Fe by ICP 50 50 U ug/L EPA 200.7 Rev4A 9/5/23 JJURGEVICH 7440-09-7 Kby ICP 0.10 2.4 ml EPA 2007 Rev44 915/23 JJURGEVICH 7439-95-4 Mg by ICP 0.10 6.3 mg/L EPA 200.7 Rev4A 9/5123 JJURGEVICH 7439-96-5 Mn by ICP 10 94 ug/L EPA 200.7 Rev4.4 9/5/23 JJURGEVICH 7440-23-5 Na by ICP 0.4 38 P mg/L EPA 200.7 Rev4.4 915/23 JJURGEVICH 7440-02-0 Ni by ICPMS 2.0 11 ug/L EPA 200.8 Rev5A 9/14123 JJURGEVICH 7439-92-1 Pb by ICPMS 2.0 2.0 U ug/L EPA 200.8 Rev5.4 9/14/23 JJURGEVICH 7440-66-6 Zn by ICPMS 40 140 P ug/L EPA 200.8 Rev5A 9/14/23 JJURGEVICH WSS Chemistry Laboratory>> 1623 Mail Service Center, Raleigh, NC 27699-1623 (919) 733-3908 "Not Detected" or"U" does not indicate the sample is analyte free but that the analyle is not cletected at or above the PQL Page 1 of 3 ArCcDWX LaboratorySection 4mtts/Sample Comments/QualiftercDefinit ions Sample ID. AD13689 Result/ Method Analysis Qualifier Units Sample Comments Coliform-Ql-Sample exceeded holding time prior to receipt at lab. Reference Date validated by NCDEQ-WSS-Chemistry Lab Data Qualifiers Al The reported value is an average, where at least one result is qualified with a 'U The PQL is used for the qualified result(S) to cal 61 Coliform-Countable membranes with less than 20 colonies. Reported value is estimated or is a total of the counts on all filters repor B2 Coliform-Counts from all filters were zero. B3 Coliform-Countable membranes with more than 60 or 80 colonies. The value reported is calculated using the count from the smalle B4 Coliform-Filters have counts of both >60 or 80 and <20. Reported value is estimated or is a total of the counts on all filters reported B5 Coliform-Too many colonies were present; too numerous to count (TNTC). TNTC is generally defined as >150 colonies. B6 Col iform-Esti mated Value. Blank contamination evident. B7 Coliform-Many non-coliform or non-enterococcus colonies or interfering non-coliform or non-enterococcus growth present. In this cc BB1 MPN-No wells or tubes gave a positive reaction. Value based upon the appropriate MPN Index and reported as a less than "<" valu B132 MPWAII wells or tubes gave positive reactions- Value based upon the MPN Index and reported as a greater than '>" value. C Total residual chlorine was present in sample upon receipt in the laboratory; value is estimated. G1 BOD-The dissolved oxygen (DO) depletion of the dilution water blank exceeded 0.2 mg/L. G2 BOD-The bacterial seed controls did not meet the requirement of a DO depletion of at least 2.0 mg/L and/or a DO residual of at lea G3 BOD-No sample dilution met the requirement of a DO depletion of at least 2.0 mg/L and/or a DO residual of at least 1.0 mg/L. G4 BOD-Evidence of toxicity. This is generally characterized by a significant increase in the BOD value as the sample concentration d[ G5 BOD-The glucose/ glutamic acid standard exceeded the range of 198 ± 30.5 mg/L. G7 BOD-Less than 1 mg/L DO remained for all dilutions set. The reported value is an estimated greater than value and is calculated fo G8 BOD-Oxygen usage is less than 2 mg/L for all dilutions set. The reported value is an estimated less than value and is calculated fol G9 BOD-The DO depletion of the dilution water blank produced a negative value. it Surrogate recovery limits have been exceeded. J10 Unidentified peak; estimated value. WSS Chemistry Laboratory>> 1623 Mail Service Center, Raleigh, NC 27699-1623 (919) 733-3908 "Not Detected" or" ll' does not indicate the sample is analyte free but that the analyle is not detected at or above the PQL. Page 2 of 3 NC OWK La6oratory Section 9�esults/Sampfe Commen ts/Qualifier47efinitions Sample ID. AD13589 pnl Result/ Method Analysis uuallner units mererence gate Y J11 The reported value is determined by a one -point estimation rather than against a regression equation. The estimated concentration J12 The calibration verification did not meet the calibration acceptance criterion for field parameters. J2 The reported value failed to meet the established quality control criteria for either precision or accuracy. J3 The sample matrix interfered with the ability to make any accurate determination. J4 The data is questionable because of improper laboratory or field protocols (e.g., composite sample was collected instead of grab, p J5 Temperature limits exceeded (samples frozen or>6°C) during transport or not verifiable (e.g., no temperature blank provided): non- J6 The laboratory analysis was from an unpreserved or improperly chemically preserved sample. The data may not be accurate. J7 This qualifier is used to identify analyte concentration exceeding the upper calibration range of the analytical instrument/method. Th J8 Temperature limits exceeded (samples frozen or >6°C) during storage, the data may not be accurate. Jg The reported value is determined by a one -point estimation rather than against a regression equation. The estimated concentration M Sample and duplicate results are "out of control'. The sample is non -homogenous (e.g., VOA soil). The reported value is the lower, N1 Presumptive evidence and estimated value. The component has been tentatively identified base on mass spectral library. N2 There is an indication that the analyte is present, but quality control requirements for confirmation were not met (i.e., presence of s N3 This code shall be used if the level is too low to permit accurate quantification, but the estimated concentration is less than the labo N4 This code shall be used if the level is too low to permit accurate quantification, but the estimated concentration is less than the labo' N5 The component has been tentatively identified based on a retention time standard. P Elevated PQL' due to matrix interference and/or sample dilution. Q1 Holding time exceeded prior to receipt by lab. Q2 Holding time exceeded following receipt by lab. S Not enough sample provided to prepare and/or analyze a method -required matrix spike (MS) and/or matrix spike duplicate (MSD). U Indicates that the analyte was analyzed for but not detected above the reported practical quantitation limit*. The number value repo U, J6 The laboratory analysis was from an unpreserved or improperly chemically preserved sample. The data may not be accurate. UU Indicates that the analyte was not detected by a screen analysis. The number value was determined by a one -point estimation at tt V Indicates the analyte was detected in both the sample and the associated method blank. Note: The value in the blank shall not be s X1 Sample not screened for this compound. X2 Sampled, but analysis lost or not performed -field error. X3 Sampled, but analysis lost or not performed -lab error. Y Elevated PQL` due to insufficient sample size. Z1 Inability to analyze the sample. Z2 Questions concerning data reliability. J13 Standards used for this analyte are from an uncertified source. These are the only standards currently available for the analyte. WSS Chemistry Laboratory» 1623 Mail Service Canter, Raleigh, NC 27699-1623 (919) 733-3908 "Not Detected" or"U" does not indicate the sample is analyte free but that the analyte is not detected at or above the PQL. Page 3 of 3