Loading...
HomeMy WebLinkAboutWQ0015053_Monitoring - 08-2023_20230930Monitoring Report Submittal ................................................... Permit Number#* WQ0015053 Name of Facility:* Moyock Commons WWTP Month: * August Year: * 2023 Report Information Type* Upload Document* NDMR, NDAR-1, NDAR-2, NDMLR Moyock Commons DMR.pdf 386.74KB PDF Only Please upload one PDF containing all applicable monitoring reports (i.e., NDMR, NDAR-1, NDAR-2, NDMLR, GW-59). Confirmation Email Address: * rod.holley@currituckcountync.gov Name of Submitter: * Rod Holley Signature: Date of submittal: 9/30/2023 This will be filled in automatically Initial Review Reviewer: Wanda.Gerald Is the project number correct?* WQ0015053 Is the monitoring report accepted?* Yes No Regional Office* Washington Reviewer: _anonymous Review Date: 10/2/2023 FORM: NDMR 03-12 NON -DISCHARGE MONITORING REPORT (NDMR) Page _ of Permit No.: WQ0015053 I Facility Name: Moyock Commons WWTP PPI: 001 Flow Measuring Point- Ll influent 0 Effluent D No now generated Parameter Code 0 60050 00310 50060 :r,316116_ 00610 (D E 4y, r M E 0 O 0 0 E r C C1 P W 0 M E 13� 0 0 24-hr hirs GPD mg/L mglL mg1L 4110 . 6mL mg/L I mWL 1 1o:00 5 8664 2 2.57 <l 1.5 5:5, 2 9:30 7 5137 0.73 3 9:30 7 8101 2.79 4 ioioo 6.5 8031 2.75 5 8031 6 8031 7 &30 8 6076 1.48 8 9:00 7 7560 1.59 9 8:30 4.5 6884 0.44 10 8:30 7 7237 2.98 11 8:00 1 7293 2.78 12 7293 13 7293 14 9;oo 7.5 8942 1.79 15 8:00 8 10696 1.5 16 1o:00 6.5 5638 1.05 17 1 o:3o 6 10561 4.04 18 10:30 6 6749 3.62 19 6749 20 6749 21 7:00 7.5 13157 3.0 22 9:oo 7.5 3856 3.7 23 9:30 7 11194 3.4 24 1 o:oo 6.5 7356 3.1 25 9:oo 7 9606 31 26 9606 27 9606 28 9:oo 7 4709 2.5 29 9:00 7 7886 1,88 30 9:oo 3.5 10603 1.11 31 10:00 6 11210 1.07 Average: 2.00 ,'-'183.00 2.33 1.00 1.50 Daily Maximum: 13;1571 2.00 4.04 1.00 1.50 5"50n Daily Minimum: 2.00 jj 183160 0.44 1.00 1.50 Samplhig Type: R666rder Composite Cdrnp6sftp Grab Composite .'Q6rnposj Monthly Avg. Limit: 40,000 15 200 4 Daily Limit: Sample Frequency: J.Contin66us , Monthly ..3 X,Year,s _5 X Week Monthly Monthly Monthl) County: Currituck Month: August Year: 2023 Parameter Monitoring Point: Ll Influent R Effluent Cl Groundwater Lowering F1 Surface Water 00620 00600 `, 00400 00666', 70300 00530, CD CL 0 0 12 CL z 0 mg/L mg/L:',1 Su mglL mg[L 0.58 6' 7.5 1.75 536 311 7.5 7.2 T2 73 7.3 7,5 7.5 7.3 7.3 T5 7.5 7.4 7A 7.3 7.3 7.3 7.5 7A 7A 7r 7.6 7.5 7.4 0.58 610 1.75 536.00 ­3.110­_� 0.58 0 7.60 -1.75- 536.00 3.10.,' 0.58 6,10, 7.20 115, "= 536.00 3.10 Composite Comp6site. Grab Composite Composite Composite Monthly Monthly 5 X Week Monthly . 3XYear FORM: NDMR 03-12 NON -DISCHARGE MONITORING REPORT (NDMR) Page of Permit No.: WQOOJ 5063• • • • . •nth: August--- 1 11 '.Parameter Monitoring ',int: Influent LJ Effluent Lj Groundwater ' II •,' il. } I1.11 li li 11.. 11. ©tea �■■ ° ■� �■t �■■■ � � � �■■ • it � ° ® ... 0 ° FORM: NDMR 03-12 NON -DISCHARGE MONITORING REPORT (NDMR) Page of Permit No.: WQ0015053 Facility Name: Moyock Commons VVWTP PPI: 004 Flow Measuring Point: ❑ Influent ❑ Effluent C ,No now generated Parameter Code --► 00610 00600 00300 00665 00625 O Z E U P ) �� O I 0O .2 M I— o z G 6 tn �O i Q N a �O m O Xz 24-hr hrs mgiL '' mglL mg1L mg/L mg/L 1 10:0o s Dry 2 9:30 7 Dry 3 9:3D 7 Dry 4 moo 6.5 Dry 5 Dry 6 Dry 7 8.30 8 Dry 8 9:00 7 Dry 9 8:30 4.5 Dry 10 8:30 7 Dry 11 8.00 1 Dry 12 Dry 13 Dry 14 9:oo 7.5 Dry 15 8:00 8 Dry 16 1o:0o 65 pry 17 1o:3o 6 Dry 18 10:3o 6 Dry 19 Dry 20 Dry 21 7:00 7 5 Dry 22 9:0o 7.5 Dry 23 9:3o 7 Dry 24 1 o:o0 6.5 Dry 25 9:oo 7 Dry 26 Dry 27 Dry .: 28 9:00 1 7 pry 29 9:o0 7 " ;Dry 30 9:o0 3.5 Dry 311 10:00 6 Dry Average: 0.00 r Daily Maximum: 0,00 Daily Minimum Q,00 Sampling Type. Grab Grab Grab Grab Monthly Avg. Limit: Daily Limit Sample Frequency: 1 3 X Year 3 X Year :3.XYear-,<, 3 X Year FORM: NDMR 03-12 NON -DISCHARGE MONITORING REPORT (NDMR) Page of Sampling Person(s) Certified Laboratories Name: Rod Holley Name: Enviro Chem Name: Name: Does all monitoring data and sampling frequencies meet the requirements in Attachment A of your permit? i✓tCompliant ❑ Non -Compliant If the facility is non -compliant, please explain in the space below the reason(s) the facility was not in compliance. Provide in your explanation the date(s) of the non-compliance and describe the corrective or PP1004 samples pulled due to dry acuonts) taken. Httacn aaoltional sneets It necessary. � report Dissolved Oxygen for the month. Operator in Responsible Charge (ORC) Certification Perm ittee Certification ORC: Rod Holley Permittee: County of Currituck Certification No.: 1012915 Signing Official: Rod Holley Grade: WW4 Phone Number: 252-232-6065 Signing Officials Title: Wastewater Superintendent Trainee Has the ORC changed since the previous NDMR? O Yes El No Phone Number: 252-232-6065 Permit Expiration: 1 1 /22/2022 jj Az� 9/17/2023 9/17/2023 Signature Date Si ature Date By this signature, I certify that this report is accurrate and complete to the best of my knowledge. I certify, under penalty of law, that this document and all attachments were prepared under my direction or supervision in accordance with a system designed to assure that atl qualified personnel properly gathered and evaluated the information submitted. Based on my inquiry of the person or persons who manage the system, or those persons directly responsible for gathering the information, the information submitted is, to the best of my knowledge and belief, true, accurate, and complete. I am aware that there are significant penalties for submitting false information, including the possibility of fines and imprisonment for knowing violations. Mail Original and Two Copies to: Division of Water Resources Information Processing Unit 1617 Mail Service Center Raleigh, North Carolina 27699-1617 FORM: NDAR-2 05-16 NON -DISCHARGE APPLICATION REPORT (NDAR-2) Page Permit No.: WQ0015053 Facility Name: Moyock Commons WWTP County: Currituck Month: August Year: 2023 Did infiltration occur at Site Name: 1 Site Name: 2 Site Name: Site Name: this facility? Area (acres): 0,63 Area (acres): 0.63 Area (acres): Area (acres): F11 YES l I NO Rate (GPD/ft): 1.25 Rate (GPD/ft`): 1.25 Rate (GPD/ft2): Rate (GPD/ft): Weather Freeboard Site Infiltrated? ❑ YEs END Site Infiltrated? DYES ❑ NO Site Infiltrated? ;J YES [ NO Site Infiltrated? ❑ Yes ❑ NO ❑ 67 L t- c O Q ` Cl - �° n a w � .... m Via.. o a > Q m F- 7 �a ❑ a }, .� 0 0 Q�'' m LL in d �a o Q Q D a� ro Ei H= T t_ Mo 0 a J D ?+ 0 0 �N .� IL o o 'c�� i a� m - '.. y ma ❑ o ,D T 0 0 �� �' lL :. m 2a�°N o a i i Q N F= - C ❑ 0 J �. O v c N OF in ft ft gal thin GPD/ft2 ft gal min GPD/ft2 ft gal min I GPD/ft2 ft gal min GPD/ft2 ft 1 C 78 0 0 0.00 3.25FT 8,664 0.32 2FT 2 C 76 0 0 0.00 3.25FT` 5,137 0.19 2FT 3 C 71 0 0 0.00 '' 3.25FT 8,101 0.30 2FT 4 R 73 0.25 0 0.00 3.25FT 8,031 0.29 2FT 5 0 0,00 8,031 0.29 6 0 0,00 ': 8,031 0.29 7 CL 8D 0.75 0 0.00 - 3FT'" 6,076 0.22 2FT 8 C 78 0 0 0.00 3FT - 7,560 0.28 2FT 9 C 74 0 0 0,00 'r 3FT ' 6,884 0.25 2FT 10 CL 77 0 0 0,00 3FT 7,237 0.26 2FT 11 C 73 0 0 0.00 3FT ' [ 7,293 0.27 2FT 12 0 0.00 7,293 0.27 13 0 0.00 7,293 0.27 141 C 1 84 0 0 0.00 3FT `' 8,942 0.33 2.25FT 151 C 1 83 0 0 0.00 3FT 10,696 0.39 2.25FT 16 CL 77 0.5 0 0.00 3FT 5,638 0.21 2.250 17 R 82 0.25 0 0,00 3FT 10,561 0.38 2.25FT 18 C 85 0 0 6.00 3FT == 6,749 0.25 2.25FT 19 0 0.00 6,749 0.25 20 0 0,00 '. 6,749 0.25 211 C 73 0 0 0.00 3FT s- 13,157 0.48 2.5FT 221 CL 78 0 0 0.00 3FT '= 3,856 0.14 2.5FT 23 c 77 0 0 0,00 317T;;;;= 11,194 0.41 2.5FT 24 CL 78 0 0 0.00 : 3FT2; 7,356 0.27 2.5FT 25 CL 79 0 0 0,00 3FT 9,606 0.35 2.5FT 26 0 0.00 3,606 0.35 s 27 0 0.00 9,606 0.35 281 CL 82 0 0 0.00 ` 3FT'r; 4,709 0.17 2.5FT 29 CL 78 0.5 0 0.00 3FT " 7,886 0.29 2.5FT 30 31 CL R B1 70 0 1.525FT,r': ` , 0,_ , , 0:00. 3FT„<: ,' 10,603 0.39 2.5FT - 11,210 0.41 2FT - - Monthly Loading (GPDlft ): 0 00 ..;;' .. 0.29 ,- #DIV10! : ,..:.: #DiV/0! Year to Date LoadingGPD1ft2 : IS_ '' FORM: NDAR-2 05-16 NON -DISCHARGE APPLICATION REPORT (NDAR-2) Page of Did the application rates exceed the limits in Attachment B of your permit? Cl Compliant ❑ Non -Compliant If not a basin, were the sites kept free of vegetation and raked? 0 Compliant ❑ Non -Compliant If not a basin, were there any instances of effluent ponding in or runoff from the sites? 0 Compliant ❑ Non -Compliant If a basin, were there any instances of breakout from the berms? 0 Compliant ❑ Non -Compliant Was the onsite automatically activated standby power source tested and operational? [� Compliant ❑ Non Compliant If the facility is non -compliant, please explain in the space below the reason(s) the facility was not in compliance. Provide in your explanation the date(s) of the non-compliance and describe the corrective action(s) taken. Attach additional sheets if necessary. Operator in Responsible Charge (ORC) Certification Permittee Certification ORC: Rod Holley Permittee: County of Currituck Certification No.: 1012915 Signing Official: Rod Holley Grade: WW4 Phone Number: 252-232-6065 Signing Official's Title: Wastewater Superintendent Trainee Has the ORC changed since the previous NDAR-2? ❑ Yes O No Phone Number: 252-232-6065 Permit Exp.: 11 /30/22 9/17/23 9/17/23 Signature Date Sjg4ature Date By this signature. I certify that this report is accurate and complete to the best of my knowledge. I certify, under penalty of law, that this document and all attachments were prepared under my direction or supervision in accordance with a system designed to assure that all qualified personnel properly gathered and evaluated the information submitted. Based on my inquiry of the person or persons who manage the system, or those persons directly responsible for gathering the information, the information submitted is, to the best of my knowledge and belief, true, accurate, and complete. I am aware that there are significant penalties for submitting false information, including the possibility of fines and imprisonment for knowing violations. Mail Original and Two Copies to: Division of Water Resources Information Processing Unit 1617 Mail Service Center Raleigh, North Carolina 27699-1617