Loading...
HomeMy WebLinkAboutSW5120101_Cover Sheet_20130410my 2 -7-7 Svis-/2v10) •492,5 / —A- r�X MAIN SITE �4 0 Day ,•'�/ V GUY G Y O ` \ R Existing R , P13 j YOOD5 �110 �� TBM EL-4.&61$ ' p �. �` �� 0 � NA�L. SET IN PINE TR E Cb i PP �\ Imo. ►is, LP ANK PP c. �\\PP GOY m AAFES / / / , ;WV , 1- 055 ID CARD SCo�a�, IN OD ��Zy= / a' / �! ` NIT L ELLOW RIBBON �\n ONTAI ER a Ole HISTORY! PA / 6 J'y 07 OGDS GUY o /PP 01 �w Co et WATER TOW W �\ \ 1 G / Wo DS 01 1\ 4935 W S 1 l INV-476.84' INV-481.78' WV Y\, /. / S o NORTH CAROLINA k; NATIONAL GUARD / _6 AJ CANTONMENT MODULAR UNIT RELOCATIONS BUILDING CODE SUMMARY: NOTE: THE MODULAR UNITS ARE EXISTING AND ARE BEING MOVED TO THE CAMP BUTNER LOCATION AND SET UP. NEW WORK PROVIDED IN THIS CONTRACT IS THE SITE WORK. SEE MAUFACTURER INFORMATION FOR UNIT -SPECIFIC APPENDIX B ITEMS. Name of Project: NCNG Cantonment Trailers Relocation DESIGN LOADS: Importance Factors: Wind (IW): 1Snow Address: 4105 Reedy Creek Rd, Raleigh, NC 27607 (IS): 1 Proposed Use: Office Seismic (IE): 1 Owner or Authorized Agent: Jack Johnson Phone#: 919-664-6244 Roof: 20 psf Owned By: State Mezzanine: NIA Code Enforcement Jurisdiction: State Floor: 50 /100 psf Snow Load: 30 psf Lead Design Professional Wind Load: Basic Wind Speed: 110 mph (AS CE-7-02) Civil: CH Engineering, PLLC; Eric M. Tweed, PE; 028912; 919-788-0224 KnotBenson Engineering; Dale Benson, PE; 11190; 919-383-7769 t Exposure Category: C.Electrical: Wind Base Shears (for MWFRS) Vx= 11472, Vy=3562 2006 Ediditon of NC Code for Existing: Current Use Seismic Design Category A RI llt_DING DATA [Tyolcal of ati Modular ____)Units) Compliance with Section 1616.4 only?: NO Construction Type: V-B Seismic Design Category: C Sprinklers: NO; Standpipe: NO; Fire District: NO Seesmic Use Group: I Building Height: 13'6'; No. of Stories: 1; Mezzanine:.NO Spectral Response Acceleration Ss-24.9%g SI-11.1 %g Gross Building Area: 1st Floor -1400 sf Site Classification: D; Presumptive Allowable Area: Business Basic Structural system: Bearing Wall Mixed Occupancy: NO Seismic base shear; Vx=1745; Vy1745 Actual/Allowable Occupancy: 0.16 s 1 Analysis Procedure: Simplified Special Approvals: Modular budding reviewed and inspected under Architectual, Mechanical Components anchored? YES NC Dept. of Insurance Manufactured Buildings Program. Lateral Design Control: WIND Energy Requirements: Soil Bearing Capacities: Presumptive Bearing Capacity 2000 psf Thermal Envelope Method of Compliance: Performance ALLOWABLE HEIGHT: ELECTRICAL SUMMARY: Building Heigh in feet Electrical System and Equipment Method of Compliance: Performance Allowable: 40'-0" Lamp type required in fixture: 34 watt Shown on Plans: ITS" Number of lamps in fixture: 2 Stories: ballast type used In fixture: Energy Saver Allowable: 2 number of ballasts in fixture: 1 Shown on Plans. 1 total wattage per fixture: 76 LIFE SAFETY SYSTEM REQUIREMENTS total interior wattage specified vs allowed (1380, 1400) Emergency Lighting: YES Total exterior wattage specifeid vs allowed: NIA Exit signs : YES MECHANICAL SUMMARY: Fire Alarm: YES Mechanical Systems, Service Systems and Equipment Method of Smoke Detection: YES Compliance: Prescriptive Panic Hardware: NO Climate zone: B Thermal Zone: Winter & Summer - Dry Bulb Mechanical Spacing Conditioning System Unitary: Descritplon: (2) wall mounted Air Conditioners cooling efficiency: 10 SEER heat output of unit: 10 KW Cooling outpout of unit: 2 TON WV w TSM EL=487.12' �v / FII PAINTED BOLT O Q / TOP FH FLANGE W;6)t OS:` c+ INV-4 3.74 1489.6 Age R�0 l 1 AbS WV Wl CONC NS INV-480.79' + r� CPU. 11 \ r•\ /' e /� 4 / G ,rug 'Y 47 p cr zBs1r+E / / �4 FFE=478.8ME `` •489P / // � 88. \ ` 3Q EQ I/ 12Q POST BID: COMMENTS BY DWQ AND OWNER DESIRED CHANGES ARE INCORPORATED INTO THIS SET. s DRAWING LIST CO TITLE SHEET C1 DEMOLITION & EROSION CONTROL C2 TRAILER SITE & MAIN PARKING LOT C3 SOUTHERN PARKING LOT SITE & GRADING C4 TRAILER SITE PLAN & NOTES C5 BASIN HYDRAULIC PROFILES 06 DETAILS C7 J4 ANNEX SITE C8 DECKING DETAILS E1 ELECTRICAL PLAN DWQ-1,2,3,4 DWQ SUPPLEMENTS APPENDICES TRAILER MANUFACTURER'S INFORMATION PROJECT INFORMATION PROJECT: CANTONMENT TRAILERS RELOCATION 539 ROBERTS CHAPEL ROAD STEM, NC 27581 OWNER: NORTH CAROLINA NATIONAL GUARD 4501 REEDY CREEK ROAD RALEIGH, NC i7607 CONTACT: JACK JOHNSON CIVIL ENGINEER: ELECTRICAL ENGINEER: CH ENGINEERING KNOTT-BENSON ENGINEERING U20 GLEN ROYAL ROAD 3310 CROASDAILE DRIVE RALEIGH, NC 27617 DURHAM, NC 27705 CONTACT: T HOMAS R. HEPLER CONTACT: DALE BENSON PHONE: (91u) :; 4 PHONE: (919) 373-7769 PROJECT IS IN : HUSE RIVER BASIN 7.6 ACRES d1 DISTURBED ACREAGE =a -ACRES PARKING: BEFORE AFTER H.0 PARKING NORTH: 0 53 d1 6 SOUTH: 70 144 ASSEMBLED MODULAR UNIT DIMENSION: 60' X 23'-4" EACH STORMWATER RETENTION AND NUTRIENT LOADING REQUIREMENTS REDUCED BY ONSITE STORMWATER BMP FACILITIES. TREATMENT ALSO TREATS AMOUNTS OF EXISTING IMPERVIOUS SURFACE AND COVERS ADDED IMPERVIOUS SURFACE AT THE J4 ANNEX SITE. BUY -DOWN FOR ADDITIONAL. NUTRIENTS WILL BE MADE FOR THIS PROJECT. VICINITY MAP NO SCALE LEGEND Rd. +� Sanitary Sewer Clean Out & Sanitary Sewer MH NATIONAL ® Water Valve RANGE SEDIMENT AREA BASIN Fire Hydrant J4 ANNE SITE CAMP® Power Transformer BUTNER --- -- EP Other DTM Break Line DTM Drainline CN Other Culture Area Outline Fence Line AZ m CTL Bench Mark �r {7 D Sign, Flog, Pole, Grd Past a L4 Wo HOPE Pipe `► P ff MAIN SITE Woods Line tea' >v 0 CENGINEERING 3220 GLEN ROYAL RD. RALEIGH, NC 27617 TELE 919.788.0224 FAX 919.788.0232 NC LICENSE #P•0189 NC NATIONAL GUARD Camp Butner Training Center 539 Roberts Chapel Road Butner, NC 27509 Bud et Code 121028 1, Item# PN 1 11-12 SC�#: 11-08915-01 A CHE: AS1101 seal/signature CA t3?8912 0 *GIN issued for date Construction Document 09/02/2011 item date �3\ ADDENDUM 3 09/13/2011 AOwner Request / DWQ 11/10/2011 CANTONMENT MODULAR UNIT RELOCATIONS key plan sheet title COVER SHEET sheet number co drawn by EMT checked by TRH WHEN PLOTTED AT FULL SIZE THIS SHEET MEASURES 24"x36" - ++T -- - r. - ;�s;- w a -i i �- i' i 'i• ' _I,�, r W'y•. ;r r 1, 1 ' ; y1r rr !++ �• 1 � e,- �•1;I�r