Loading...
HomeMy WebLinkAboutSW4090301_Designer's Certification_20090519State Stornivfater Permit Permit No. SV14090301 MOD McDonald's, S. Main St. — King, NC Stormwater Permit No, SW4090301 Stokes County Designer's Certification t, Wilbur E. Christmas , as a duly registered _ Professional Engineer in the State of North Carolina, having been authorized to observe (periodically/ weekly/ full time) the construction of the project, McDonald's S. Main St. King, NC (Project Name) for McDonald's USA, LLC (Project Owner) hereby state that, to the best of my abilities, due care and diligence was used in the observation of the project construction such that the construction was observed to be built within substantial compliance and intent of the approved plans and specifications. The checklist of items on page 2 of this form is included in the Certification. Noted deviations from approved plans and specification: Signature " Registration Number Date / z - 7 - o 235§' 2 4 * � ctC n • izt. e o ri2,3 2 s L J Js. g� h 1- ,n r �`tr� �. i � EZ�,Q• 'fCCf!ls9t�S� Page 5 of 6 State Stornwfater Permit Permit No. SVV4090301 K40D Certification Requirements: f 1. The drainage area to the system contains approximately the permitted acreage. <� 2. The drainage area to the system contains no more than the permitted amount of built -upon area. til 3. All the built -upon area associated with the project is graded such that the / runoff drains to the system. V 4. All roof drains are located such that the runoff is directed into the system. 5. The outlet/bypass structure elevations are per the approved plan. f 6. The outlet structure is located per the approved plans. NIA 7. Trash rack is provided on the outletlbypass structure. 8. All slopes are grassed with permanent vegetation, per the vegetation plan. ✓ 9. Vegetated slopes are no steeper than 3:1. 10. The inlets are located per the approved plans and do not cause short- circuiting of the system. 11. The permitted amounts of surface area andlor volume have been provided. 12. Required drawdown devices are correctly sized per the approved plans. 13. All required design depths are provided_ 14. All required parts of the system are provided, such as underdrains, vegetative cover, and a forebay. V! 15. The required system dimensions are provided per the approved plans. cc: NCDENR-DWQ Winston-Salem Regional Office 585 Waughtown Street Winston-Salem, NC 27107 NCDENR-DWQ Central Files 1617 Mail Service Center Raleigh, NC 27699-1617 Page 6 of 6