HomeMy WebLinkAboutSW4131203_Details_20140109PAVEMENT GENERAL NOTES: 1. DETAILS ARE DOLLAR GENERAL MINIMUM REQUIREMENTS AND MAY INCREASE WITH VARIOUS SOIL CONDITIONS. A GEOTECHNICAL INVESTIGATION WITH PAVEMENT DESIGN RECOMMENDATIONS SHALL BE COMPLETED FOR EACH DEVELOPMENT THE FOLLOWING DETAILS ARE MINIMUM DOLLAR GENERAL PAVEMENT REQUIREMENTS. INCREASED RECOMMENDATIONS ARE TO BE USED. 2. THE SUBGRADE MATERIALS SHALL BE PROOF ROLLED AND/OR SCARIFIED AND COMPACTED PRIOR TO PLACEMENT OF BASE MATERIAL, WHERE EXISTING SUBGRADE MATERIALS ARE UNSUITABLE, THEY SHALL BE REMOVED AND REPLACED WITH COMPACTED SELECT MATERIAL IN ACCORDANCE WITH GEOTECHNICAL RECOMMENDATIONS. 3. HEAVY DUTY CONCRETE PAVEMENT AND STANDARD DUTY CONCRETE PAVEMENT (AS RECOMMENDED BY THE GEOTECHNICAL REPORT OR DOLLAR GENERAL MINIMUMS) SHALL BE STEEL REINFORCED. REINFORCEMENT TYPE SHALL BE PRIOR APPROVED BY DOLLAR GENERAL. 4. CONCRETE PAVEMENT PLAN SHALL BE PROVIDED TO DOLLAR GENERAL FOR PRIOR APPROVAL. ALL JOINTS MUST BE SEALED WITH AN APPROVED SEALANT. STEEL REINFORCING SHALL BE USED AT JOINTS. REFER TO ACI 330R (GUIDE FOR DESIGN AND CONSTRUCTION OF CONCRETE PARKING LOTS) FOR JOINT DESIGN AND LAYOUT. 3" ASPHALT WEARING COURSE (2) 1.5" LIFTS NCDOT SF-9.5A 6" COMPACTED AGGREGATE BASE Z W COMPACTED SUB GRADE W ¢ STANDARD DUTY ASPHALT DETAIL a. U SCALE: NOT TO SCALE MATERIALS AND CONSTRUCTION REQUIREMENTS PER THE NORTH CAROLINA E, DEPARTMENT OF TRANSPORTATION STANDARDS AND SPECIFICATIONS, LATEST EDITION a -- x a. 1.5" ASPHALT WEARING COURSE NCDOT SF-9.5A 2.5• ASPHALT BINDER COURSE NCDOT 1-19.08 8" COMPACTED AGGREGATE BASE COMPACTED SUB GRADE HEAVY DUTY ASPHALT DETAIL SCALE: NOT TO SCALE MATERIALS AND CONSTRUCTION REQUIREMENTS PER THE NORTH CAROLINA DEPARTMENT OF TRANSPORTATION STANDARDS AND SPECIFICATIONS, LATEST EDITION REINFORCING AS RECOMMENDED BY GEOTECHNICAL CONSULTANT (RE: NOTE 3 ABOVE) 5" 4,000 PSI CONCRETE --- 4" COMPACTED AGGREGATE BASE COMPACTED SUB GRADE STANDARD DUTY CONCRETE DETAIL E-F z W SCALE: NOT TO SCALE MATERIALS AND CONSTRUCTION REQUIREMENTS PER THE NORTH CAROLINA DEPARTMENT OF TRANSPORTATION STANDARDS AND SPECIFICATIONS, LATEST EDITION W - ¢C2. REINFORCING AS RECOMMENDED BY GEOTECHNICAL CONSULTANT F (RE: NOTE 3 ABOVE) r� Ix U Z CD 6" 4,000 PSI REINFORCED CONCRETE AT DUMPSTER/LOADING AREA 6" COMPACTED AGGREGATE BASE COMPACTED SUB GRADE HEAVY DUTY CONCRETE DETAIL SCALE: NOT TO SCALE MATERIALS AND CONSTRUCTION REQUIREMENTS PER THE NORTH CAROLINA DEPARTMENT OF TRANSPORTATION STANDARDS AND SPECIFICATIONS, LATEST EDITION I PAVEMENT DETAILS C— 7 NOT TO SCALE ACCESSIBLE PARKING SIGNAGE NOTES 1. ALL LETTERS ARE TO BE PER THE LATEST EDITION OF THE MUTCD. 2. TOP PORTION OF SIGN SHALL HAVE A REFLECTORIZED (ENGINEERING GRADE) BLUE BACKGROUND WITH WHITE REFLECTORIZED LEGEND AND BORDER. 3. BOTTOM PORTION OF SIGN SHALL HAVE A REFLECTORIZED (ENGINEERING GRADE) WHITE BACKGROUND WITH BUCK OPAQUE LEGEND AND BORDER. 4. FINE NOTIFICATION SIGN SHALL HAVE A REFLECTORIZED (ENGINEERING GRADE) WHITE BACKGROUND WITH BUCK OPAQUE LEGEND AND BORDER. CONTRACTOR SHALL VERIFY FINE AMOUNT AND ORDINANCE NUMBER. 5. ONE (1) SIGN REQUIRED FOR EACH ACCESSIBLE PARKING SPACE. 6. INSTALLED HEIGHT OF SIGN SHALL BE IN ACCORDANCE WITH SECTION 24-23 OF THE MANUAL ON UNIFORM TRAFFIC CONTROL DEVICES. (MUTCD) 7. SIGN MAY BE MOUNTED ON BUILDING/WALL, AT PROPER HEIGHT, IF AUGNED WITHIN 12" OF CENTER OF PARKING SPACE. MUTCD VAN R7-BP ACCESSIBLE 12"x6" [RESERVED] PARKING MUTCD R7-8 12%18" MAXIMUM PENALTY 12"x9" OS30-S).e PA HANDICAP SIGN MUTCD VAN R7-8P ACCESSIBLE 12%6" RESERVED PARKING MUTCD R7-BE 12"z2fi° MAXIMUM PENALTY $250 cezo-n.e HANDICAP PARKING, ACCESS RAMP AND ACCESS AISLE DETAILS NOT TO SCALE SITE ACCESSIBILITY DETAIL NOTES: 1, REFER TO SITE PLAN FOR EXACT LOCATION OF HANDICAP PARKING, WALKWAYS AND RAMPS. 2. ALL WALKWAYS, RAMPS, AND HANDICAP PARKING SIGNAGE, ETC. SHALL MEET APPROVED AMERICANS WITH DISABILITIES ACT (ADA) STANDARDS AND LOCAL ACCESSIBILITY CODE. 3, ONE OUT OF EVERY EIGHT (8) ACCESSIBLE PARKING SPACES, BUT NOT LESS THAN ONE, IS REQUIRED TO BE VAN ACCESSIBLE. 4, ALL CONCRETE ACCESSIBLE RAMPS (3000 PSI) SURFACES SHALL HAVE COLORED TOOLED/SERRATED SLIP RESISTAND SURFACING AND/OR TACTILE WARNING DEVICE PER ADA STANDARDS AND LOCAL ACCESSABILITY CODE, 5. ALL CONCRETE ACCESSIBLE RAMPS SHALL BE COLOR IMPREGNATED TO PROVIDE VISUAL CONTRAST (DARK TO LIGHT) WITH ADJOINING CONCRETE SURFACES (MINIMUM 70% COLOR CONTRAST), 6. THE MATERIAL USED TO PROVIDE COLOR CONTRAST IN CONCRETE ACCESSIBILE RAMPS SHALL BE AN INTEGRAL (PERMANENT) PART OF THE CONCRETE AND SHALL NOT BE PAINTED ON OR CAPABLE OF FADING OR WEARING OFF. 7, FINISHED GRADES OF PAVEMENT IN HC PARKING AND ACESSIBIUTY AISLE SHALL NOT EXCEED 1:50 SLOPE IN ANY DIRECTION. 1:10 MAX BOLLA R PARKING S RE PANTED SEE ARCH PLANS H.C. / SHOPPING CART RAMP TO BE CENTERED ABOUT THE FRONT DOOR. g HANDICAP PARKING DETAIL C—% NOT TO SCALE STANDARD STATE APPROVED HANDICAPPED SIGNAGE INSTALLED ON A METAL COLUMN AT THE PROPER HEIGHT REQUIRED. PROVIDE ADDITIONAL SIGNAGE AS REQUIRED PER REGULATIONS BOLT SIGNS TO GALVANIZED METAL PIPE COLUMN I I N REENSTREAK PAVING CAP SEAL ROFILE #610 - SEE SPECIFICATIONS FOR ADDITIONAL INFORMATION. TYPICAL EXPANSION JOINT 5 CONCRETE JOINTS C-7 NOT TO SCALE o CONCRETE FILLED STEEL P PERBOLLARD, PAINTED YELLOW 6 0" a 1 III -6" MIN. HANDICAP PARKING SIGN DETAIL NOT TO SCALE COLORED TOOLED/SERRATED SLIP RESISTANT SURFACING AND/OR TACTILE WARNING DEVICE AS REQUIRED BY AMERICAN WITH DISABILITIES ACT ACCESSIBILITY GUIDEUNES AND CODE REQUIREMENTS 1:10 MAX. SLOPE PAINTED YELLOW BOLLARD WITH HANDICAP PARKING SIGN, AS REQUIRED. 4" PAINTED STRIPES - HC BLUE COLOR 0 24" O.C. AT 45 DEGREES. 4" PARKING SPACE STRIPE. BLUE COLOR. NM ALL HANDICAPPED RAMP AND ACCESS ISLES SHALL MEET ALL CODES AND ADA REGULATIONS. SURROUND AROUND PIPE COLUMN PUN CONTRACTOR TO COORDINATE EXACT REBAR HOLE SIZES AND LOCATIONS WITH WHEEL STOP MANUFACTURER. 3/4" - 1" DIA. HOLE I8" #3 REBAR. FILL HOLE WITH SLURRY — MIX OF NON -SHRINK GROUT AFTER REBAR INSTALLATION. g WHEEL STOP C -7 NOT TO SCALE SEALANT 1/2• 6X6 - 10/10 WWF 4" GONG. SIDEWALK . ' 71�— COMPACTED SUBGRADE CCR (REFER TO GEOTECHNICAL—--�_=-' " •_ REPORT) #4 CONTINUOUS STEEL REBAR (TOP AND BOTTOM); — CURB EDGE CONCRETE SIDEWALK NOT TO SCALE INSTALL A GROOVE 6" FROM FACE OF CONCRETE SIDEWALK 9'-0- (MIN) WIDE TURN -DOWN STYLE CONCRETE SIDEWALK IN FRONT OF BUILDING - SLOPE AWAY FROM BUILDING. g SIDEWALK DETAIL C—% NOT TO SCALE 2"-4" 4x4 SPACING FRONT 17 TOP VIEW 1X6 2X4 g HVAC SCREEN FENCE C — 7 NOT TO SCALE SAWCUT JOINT - FILL WITH SELF LEVELING ELASTOMERIC SEALANT NOTE: SEE SPECIFICATIONS FOR SPACING REQUIREMENTS TYPICAL CONTROL JOINT :2 TO FACE OF BUILDING 8" ASPHALT PAVEMENT 1- RAO. ASPHALT PAVEMENT 1SPHALT PAVEMENT COMPACTED STONE BASE COMPACTED SUB BASE TREATED PINE (USE GALVANIZED NAILS FOR FASTENING) IF ANY PARCEL OF LAND ADJACENT TO THE DEMISED PREMISES IS EITHER ZONED FOR RESIDENTIAL USE OR IS ACTUALLY BEING USED FOR RESIDENTIAL PURPOSES ('RESIDENTIAL PROPERTY"), LESSOR SHALL CONSTRUCT A PRIVACY FENCE IN ACCORDANCE WITH TENANTS PROTOTYPE PLANS AND ANY APPLICABLE ORNAMENTAL REQUIREMENTS ALONG ANY PORTION OF THE DEMISED PREMISES BORDERING UPON SUCH RESIDENTIAL PROPERTY. NOTE: NUMBER OF BOARDS WILL VARY DEPENDING ON SPACE BETWEEN BOARDS AND ACTUAL WIDTH OF BOARDS. REAR AEW TRIANGLE SITE DESIGN CONSULTANT. Triangle Site Design, PLLC 4006 Barrett Drive Suite 203 Raleigh, NC 27609 (919)553-6570 mlowder@trianglesitedesign.com NC LICENSE yP-0619 SEAL: ;�4QOFEssio!i= SEAL 24434 01 1 •• 0 •I .'' '•. �'W E. �'�, , l OWNER/DEVELOPER: GLANDON FOREST EQUITY, LLC 3900 Merton Drive Suite 210 Raleigh, NC 27609 919-459-2602 919-459-2604 fx gventers(@vanguardpg co m REVISIONS: LAYOUT COORD: 1\1EL PLANNING MGR. P,IEL DRAWING BY: 1fEL DATE: 12 12/13 JOB NUMBER: 004063 TITLE: CONSTRUCTION DETAILS SHEET NUMBER: 11 COMMENTS: B 2 1/4" (TYP) e r m 6" DIA. STL. CONC. FlLLED GATE POST FRAME AND CROSS BRACE METAL CATE FENCING GATE HINGE GATE POST DETAIL 6" DIA. STL CONIC. CONCRETE PAD (HEAVY FILLED GATE POST DUTY CONCRETE) DOUBLE DUMPSTER LAYOUT DETAIL 4' PRE -CAST CAP NOTE: TTT— FOO7ING TO I JLJI MATCH BUILDING SEE STRUCTURAL DWGS. (TYP. FTG.) 3" J HANDLE I DOUBLE DUMPSTER DETAILS C —S NOT TO SCALE BLOCK DUMPSTER SCREEN WALL ((5'S AT 32• ON CENTER VERTICALLY. i 8" BLOCK TO MATCH BUILDING TION A -A - WALL SECTION `1/2" STEEL DROP BARS 1" DIA P/C SLEEVES 6" LONG ELEVATION REFER TO GRADING PLAN STEEL HINGE - METAL GATE 6" DIA. STL CONC. FILLED GATE POST GATE HINGES ANCHORED TO POST AND FASTENED TO DOOR BRACE, 6" DIA STL. CONIC. FILLED GATE POST 8" BLOCK BACKFILL TO TOP OF CURB CONCRETE COMPRESSIVE STRENGTH SHALL BE 3600 PSI IN 26. CONFlRM WITH GEOGRAPHICAL LOCATION OF THIS PARTICULAR PROJECT. 2 CURB/GUTTER DETAIL C - B NOT TO SCALE NOTE: SET BOLLARD INTO CONCRETE TOOTER AS SHOWN. POUR CONCRETE SIDEWALK TO BOLLARD. CONCRETE WASH DOME - PROVIDE SMOOTH, - - - - - -� ROUND SURFACE ' METAL DUMPSTER LATE - 4" PIPE - CONCRETE FILLED. REFER TO PLANS FOR SIZE AND LOCATION. PAINT OSHA SAFETY YELLOW. 0 SLOPE SURFACE AWAY FROM PIPE TO 1/2" PRE -MOLDED EXPANSION JOINT (TYP.) ASHPHALT (OR) CONIC. PAVING g STOP SIGN DETAIL C-13 NOT TO SCALE STEEL PIPE EMBEDDED IN CONCRETE FOOTING. 1' 4" 3 TYPICAL BOLLARD DETAIL C—B NOT TO SCALE NOTE: 1. WORDS AND ARROWS FOR DRIVEWAYS SHALL BE APPLIED ACCORDING TO REQUIREMENTS AS OUTLINED IN SECTION 3B OF THE MANUAL ON UNIFORM TRAFFIC CONTROL DEVICES FOR STREETS AND HIGHWAYS 2. THESE WORDS AND ARROWS ARE TO BE PAINTED REFLECTIVE WHITE. 4 PAVEMENT MARKINGS C -8 NOT TO SCALE 2"x4" STRINGERS TOP, CENTER, & BOTTOM 4"W POSTS 6'-0" TO 8'-0" O.C. HINGE 1"x4" x 6'-0" FENCING 7 WOOD SCREEN FENCE C—S NOT TO SCALE NOTE - NO COTE IS REQUIRED FOR THIS DEVELOPMENT DUE TO THE SHORT LENGT OF PROPOSED FENCING. WOOD FENCE NOTES I) ALL POST AND STRINGERS SHALL BE OSMOSIS TREATED OR PENTA TREATED PINE, TO BE APPROVED BY ENGINEER. 2) ALL FENCE SIDING SHALL BE OSMOSIS TREATED OR PENTA TREATED LOCK PINE, TO BE APPROVED BY ENGINEER HASP 3) ALL METAL FASTENERS SUCH AS VN R) BOLTS, NAILS, HINGES, HASPS, AND ETC. SHALL BE HOT DIPPED GALVANIZED. 4) FENCE DIRECTION AS NOTED ON PLANS OR AS DIRECTED BY OWNER, 5) SPLICE STRINGERS AT POSTS ONLY. i TRIANU-1 - SITE DESIGN CONSULTANT: i Triangle Site Design, 1111C 4006 Barrett Drive Suite 203 j Raleigh, NC 27609 (919)553-6570 mlowder@trianglesi Led esign.co c. NC LICENSE #P-0619 J SEAL: CAR :��`�•• .....0//' ••SEAL • •"�'{ ,, - 24434{`rJ (75 i i W Z W O I U 2 zz0 b0 C Z Ca G OWNER/DEVELOPER: GLANDON FOREST EQUITY, LLC 3900 Merton Drive Suite 210 Raleigh, NC 27609 919-459-2602 919-459-2604 fx gventers@vanguardpg.com i REVISIONS: LAYOUT COORD: MEi PLANNING MGR. -MEL DRAWING BY: "'IEL DATE: 19/12/13 JOB NUMBER: 00406 TITLE: CONSTRUCTION DETAILS SHEET NUMBER: C-8 COMMENTS 03 CLASS I RIP RAP (SEE SECTION THIRD BASIN BELOW) MAINTENANCE INSPECT INLET PROTECTION ONCE A WEEK AND AFTER EVERY RAINFALL %LOW IMMEDATECY REMOVE SEDIMENT FROM i THE FLOW AREA AND REPAIR THE-- \\ ,Y.r% -, t3..E^=- INVE ''._ RIP RAP HEADWALL DIVERSION REPAIR THE CHANNEL UN/NC \ �"�'' - �. ...-,E-.; AS NECESSARY PER THE MANUFACTURERS INSTALLATIONk5 WASHED STONE. 1'-0" THICK REQUIREMENTS CHECK OUTLETS AND �sE �Y77///lllllllLll1111� x 3'-0" HIGH MINIMUM MAKE T/MECY REPAIRS AS NEEDED TO - / °iMEM STD,RACE AREA AVOID GOLLY THE IMETNLET WHEN THE AREA ABODE THE PR07ECTlON IS � PERMANENTLY STABILIZED, REMOVE THE PROTECTION AND FILL AND STABILIZE 7HE / CHANNEL 70 BLEND WITH THE NATURAL SURFACE / / ' PERSPECTIVE VIEW NO SCALE AREAS TO BE DISTURBED SEDIMENT STORAGE r FLOOD STORAGE ZONE RIP RAP (CUT, FILL, ETC.) / 1' 2' HEADWALL MAINTENANCE PER/00/C41LY SLOPES FOR THESE AREAS ORIGINAL ORAL MULCH AS SO `LOW z I? T INVERT �-NATURAL GROUND 3. FLOW - I III III= =I II iTuli'=i: = CUSS I RIP RAP MAXIMUM SEDIMENT DEPTH Ifs WASHED STONE (CLEAN OUT POINT) SECTION THRU CATCH WIN FILTER AND CULVERT PIPE NO SCALE 6 HORSESHOE INLET PROTECTION C-9 NOT TO SCALE 7 \ SLOPE TRACKING DETAIL C-9 / NOT TO SCALE �-DEWATERING CONCRETE BLOCK RAD a y; , a ,�.l�i-* }�o OGo moo- cWDoama� 2:1 SLOPE, GRAVEL FILTER TEMPORARY SEDIMENT POOL WIRE SCREEN DEWATERING 16"MIN. 16" 2'MAX. I, SEDIMENT CONSTRUCTION SPECIFICATIONS L LAY ONE BLOCK ON EACH SIDE OF THE STRUCTURE ON ITS SIDE ON THE BOTTOM ROW TO ALLOW POOL DRAINAGE. THE FOUNDATION SHOULD BE EXCAVATED AT LEAST 2 INCH BELOW THE CREST OF THE STORM DRAIN. PUCE THE BOTTOM ROW OF THE BLOCK AGAINST THE EDGE OF THE STORM DRAIN FOR LATERAL SUPPORT AND TO AVOID WASHOUTS WHEN OVERFLOW OCCURS. IF NEEDED, GIVE LATERAL SUPPORT TO SUBSEQUENT ROWS BY PLACING 2x4 WOOD STUDS THROUGH BLOCK OPENINGS. 2. CAREFULLY FIT HARDWARE CLOTH OR COMPARABLE WIRE MESH WITH 1/2-INCH OPENING OVER ALL BLOCK OPENING TO HOLD GRAVEL IN PLACE. 3. USE CLEAN GRAVEL,3/4-TO 1/2-INCH IN DIAMETER, PLACED 2 INCHES BELOW THE TOP OF THE BLOCK ON A 2:1 SLOPE OR FLATTER AND SMOOTH IT TO AN EVEN GRADE. DOT #57 WASHED STONE IS RECOMMENDED. MAINTENANCE SPECIFKA710N5 INSPECT INLETS AT LEAST WEEKLY AND AFTER EACH S/6461FIC40 (112 INCH OR 65E47ER) RAINFALL EVENT. CLEAR THE MESH WIRE OF ANY DEBRIS OR OTHER OBJECTS TO PROWOE AOEOUATE FLOW FOR SUBSEQUENT R41NS TAKE CARE NOT TO DAMAGE OR UNDERCUT THE WIRE MESH DURING SEDIMENT REMOVAL. REPLACE STONE AS NEEDED TEMPORARY INLET PROTECTION C-9 NOT TO SCALE -HUB END ON OUTLET B NOTE USE DOZER TRACKS TO CREATE GROOVES PERPENDICULAR TO THE SLOPE, GROOVES WILL CATCH SEED, FERTILIZER, MULCH, RAINFALL AND DECREASE SEDIMENT IN RUNOFF. GENERAL NOTES: I. A STABILIZED PAD OF CRUSHED STONE SHALL BE LOCATED WHERE TRAFFIC WILL BE ENTERING OR LEAVING A CONSTRUCTION SITE TO OR FROM A PUBLIC STREET, 2. STONE TO BE 2"-3" WASHED STONE 3. THE ENTRANCE SHALL BE MAINTAINED IN A CONDITION WHICH WILL PREVENT TRACKING OR FLOWING OF SEDIMENT ONTO PUBLIC STREETS OR EXISTING PAVEMENT. THIS MAY REQUIRE PERIODIC TOP DRESSING WITH ADDITIONAL STONE AS CONDITIONS DEMAND AND REPAIR AND/OR CLEANOUT OF ANY MEASURES USED TO TRAP SEDIMENT. 4. ALL SEDIMENT SPILLED, DROPPED, WASHED OR TRACKED ONTO PUBLIC STREETS MUST BE REMOVED IMMEDIATELY. WHEN NECESSARY WHEELS MUST BE CLEANED TO REMOVE SEDIMENT PRIOR TO ENTERING A PUBLIC STREET. WHEN WASHING IS REQUIRED, IT SHALL BE DONE ON AN AREA STABILIZED WITH CRUSHED STONE WHICH DRAINS INTO AN APPROVED SEDIMENT BASIN. 5. FILTER FABRIC SHALL BE MIRAFI 500 OR EQUAL. 6. ENTRANCE SHALL BE A MINIMUM OF 20' IN WIDTH OR THE WIDTH OF THE EXIT, WHICHEVER IS GREATER. EXISTING GROUND MINIMUM 10 GAUGE LINE WIRES I� i NOTE SOIL STABILIZATION FABRIC UNDER WASHED STONE 4 CONSTRUCTION ENTRANCE C-9 NOT TO SCALE 6'-0' MAXIMUM _ I (If , Ohl SILT FENCE FABRIC Mm INSTALLED TO SECOND fd� r Y WIRE FROM TOP Ix ,-1 •_Il rl 1 Cll�u�!1-JLI uC!L;=1iLH�H111�T T.Ui-T ,Ili. E FRONT VIEW MAINT RANI NOTES E CE. (Wil - 1. FILTER OUTLE75 SHALL SE INSPECTED BY THE RAONCALLY RESPONSIBLE PARTY OR HIS AGENT IMMEDATECY AFTER EACH 1. USE SILT FENCE ONLY WHEN RAINFALL AND AT LEAST DAILY DURING PROLONGED RNNFALC. DRAINAGE AREA DOES NOT ANY REPAIRS NEEDED SHAG BE MALE /MMEOAIRY EXCEED 1/4 ACRE AND NEVER IN AREAS OF CONCENTRATED FLOW. Z THE STONE SHALL BE REPIACEO PROAYPTZY AFTER ANY EY£NT THAT HAS CLOGGED OR REMOVED IT. 2. REMOVE SEDIMENT DEPOSITED AS NEEDED TO PROVIDE STORAGE J S£OIMENT DEPOSITS SHOULD BE REMOVED WHEN DEPOSITS VOLUME FOR THE NEXT RAIN AND REACH 6 INCHES ANY 5E0/MENT OEPo5/7S REMAINING /N REMOVE PRESSURE ON THE PLACE AFTER THE SILT FENCE OUTLET IS REMOVED SHALL BE SI LT FENCE. S DRESSED TO CONFORM TO THE EXIST/NC CRADE, PREPARED AND SEEDED. 5 SILT FENCE C-9 NOT TO SCALE DESIGN CRITERIA ME DRAINAGE AREA IS UNITED TO DIVE HALF ACRE. KEEP A MAXIMUM HEIGHT OF 2 FEET AT THE CENTER OF ME DAM. KEEP ME CENTER OF THE CHECK DAM AT LEAST 9 INCHES LOWER MAN ME OUTER EDGES AT NATURAL GROUND ELEVATION. KEEP THE SIDE SLOPES OF ME DAM AT 2:1 M RATTER ENSURE MAT ME NAIfIMUM SPACING BETWEEN DAMS PULES ME TOE OF ME UPSTREAM DAM AT ME SAME ELEVATION AS ME TOP OF ME DOWNSTREAM DAM. STABIUZE OUTROW AREAS ALONG ME CHANNEL TO RESIST EROSION. USE MOODY CUSS B STONE AND LINE ME UPSTREAM SIDE OF ME DAM MM MCDOT K5 OR 457 STONE KEY ME STONE INTO ME LATCH BANKS AND EXTEND IT BEYOND ME ABUTMENTS A MINIMUM OF 1.5 FEET TO AVOID WASHOUT FROM OMERROW AROUND ME DAM. NOTES 1. RACE STONE TO THE LINE AND DIMENSION SHOWN IN ME PLAN ON A FILTER FABRIC FOUNDATION. 2. KEEP ME CENTER STONE SECTION AT LEAST 9 INCHES BELOW NATURAL GROUND LEVEL WHERE ME DAM ABUTS ME CHANNEL BANKS 3. EXTEND STONE AT LEAST 1.5 FEET BEYOND ME DITCH BANK TO KEEP WATER PROM CUTTING AROUND ME ENDS OF ME NECK DAM. 4. SET SPACING BETWEEN DAMS TO ASSURE MAT ME EIE-TW AT ME TOR OF ME LOWER DAM IS ME SAME AS ME TOE ELEVATON OE ME UPPER DAM, 5. REDIRECT ME CHANNEL AFTER ME LOWEST CHECK DAM FROM HEAW ROW MAT CWID CAUSE E MON 6. MAKE SURE MM ME CHANNEL REACH ABOVE ME MOST UPSTREAM IS STABLE, 7. ENSURE MAT OTHER AREAS OF ME CHANNEL. SUCH AS CULVERT ENTRANCES BELOW ME NECK DAMS, ARE NOT SUBJECT TO DAMAGE OR BLOCKAGE FROM DISPLACED STONES 12- OF NCDOT ,95 OR W57 WASHED STONE 1.5' CLASS B RIP-11 00 1 O FILTER CLOTH „ END SECTIONS. SPIGOT III NATURAL GRADE END ON INLET END SECTIONS. E _ MI X r-o b I= 2 RIP -RAP 2 - n - - =' STEEL BACK ROD 4" #5 WASHED STONE B PLAN I' MIN. II LAYER OF FILTER FABRIC NOTES RIPRAP SHOULD EXTEND UP BOTH SIDES OF THE APRON AND AROUND THE END OF THE PIPE OR CULVERT AT THE DISCHARGE OUTLET AT A MAXIMUM SLOPE OF 2:1 AND A HEIGHT NOT LESS THAN TWO THIRDS THE PIPE DIAMETER OR CULVERT HEIGHT. THERE SHALL BE NO OVERFLOW FROM THE END OF THE APRON TO THE SURFACE OF THE RECEIVING CHANNEL. THE AREA TO BE PAVED OR Rip-' RAPPED SHALL BE UNDERCUT SO THAT THE INVERT OF THE APRON SHALL BE AT THE SAME GRADE (FLUSH) WITH THE SURFACE OF THE RECEIVING CHANNEL. THE APRON SHALL HAVE A CUTOFF OR TOE WALL AT THE DOWNSTREAM END. MAXIMUM TAPER TO RECEIVING CHANNEL 5:1. THE WIDTH OF THE END OFTHE APRON SHALL BE EQUAL TO THE BOTTOM WIDTH OF THE RECEIVING CHANNEL. ALL SUBGRADE STRUCTURE TO BE COMPACTED TO 95% OR GREATER. THE PLACING OF FILL, EITHER LOOSE OR COMPACTED IN THE RECEIVING CHANNEL SHALL NOT BE ALLOWED. NO BENDS OR CURVES IN THE HORIZONTAL ALIGNMENT OF THE APRON WILL BE PERMITTED. MANIFNANCE g RIP -RAP APRON INSPECT RIP-R4P APRON AT REGULAR NTERYALS AS AFTER AATOR R41NS, AND MAKE RERS PROMPR Wc�EU � C-9 NOT TO SCALE SPECAL AIIENTIOV TO THE POINT WHERE CONCENTRATED STORM WATER FROM ORALN46E PIPE SYSTEMS ENTER THE APRON CAREFULLY CHECK STABN7Y OF R/P-RAP AND LOOK FOR INDICATIONS Of PIPING, SCOUR HOLES, OR BANK FAILURES MAKE REPAIRS IMMEDATECY. 4' TO 6' 10 CHECK DAM C-9 NOT TO SCALE 2' MAX AT Rip -Rap Apron#1 DIMENSIONS ENTRY WIDTH 3.0 FT LENGTH 6.0 FF EXIT WIDTH 7.0 FT MIN. THICKNESS 22 IN MIN. SNE DIAMETER METER 6 IN STONE CLTO ASS B Rip -Rap Apron#2 DIMENSIONS ENTRY WIDTH 3.8 FT LENGTH 7.5 Ff EXIT WIDTH 8.8 FF MIN. THICKNESS 22 IN MIN. STONE DIAMETER 6 IN SiL TONE CLASS B MIN. 10 G0. LINE WIRES 4' MIN. �51L7 FENCE STEEL FENCE PO WIRE FENCE HARDWARE CLOTH NOTES: " 1 REMOVE SEDIMENT /NSPECT CONSTRUCTION ENTRANCE PERIODICALLY � � T r PT �- � x � ', 4 ! rl WHEN HALF OF STONE E FILTER 5 OF 7 5 WASHED STONE � FILTER 0 57 WASH F � WASHED STONE FOR CONOIRON OF SURFACE TOP -DRESS WITH TOP OF SILT FENCE Jlt [{ 41 �... iVl _! .I _ "T'., Y: OUTLET IS COVERED. \ e � „a a, NEW GRAVEL AS NEEDED MUST BE AT LEGST I' '('" . T If k',:': .!.,r "" :. 2. REPLACE STONE ASC"'c�;t4 . o � b 4� e`;T / 3' FILTER FABRIC 6 ABOVE THE TOP OF 'r, a ..r...1.... 's' I: 4�;,. _. ., s ''� t NEEDED TO ENSURE c� >e�°o o_ o�° o°cdF. ON GROUND THE WASHED STONE F :' I] � DEWATERING. - -�G284Po°�o 38 godi3y i.B°$"� B MAX IIII■ ■■I 1111111196 mill IIIII .. ■■■■■■ N1111 �� ii �'�■�� III FROM VIEW BURY WIRE FENCE AND HARDWARE CLOTH BOTTOM OF WIRE FENCE AND STEEL FENCE POST BURY WIRE FENCE, FILTER FABRIC BURIED 8• SET MAX 2' APART FILTER FABRIC, VERTICALLY AND 4" HORIZONTALLY MIN. 18' INTO AND HARDWARE SECTION VIEW IN EXCAVATED TRENCH MIN. 12-12 GA. SOLID CLOTH IN TRENCH INTERMEDIATE GROUND MOWEMl NOTES: WIRES I ao' 3 SILT FENCE OUTLET I. AFTER 40HRssRVL B9IAT LOST By rDIRWA7 PRLLr ResPR40WEE PAVYoRNa AGENT?IWAS24Tfir BE 1-� -�-1 AFTER ZID? EACH75 SyAFL ANO AT IECIE By 7BURHE N4' PRUY RED R4WbEF ANY 6W R S NEEDED SHALL 9E M40E cRADE C-9 NOT TO SCALE IMMELKITLZY 1- 2 ME SRM'E SWI BE REPZACED PROMPTLY AFTER ANY EYAVT 7MT HAS CLCGCLD OR AFII KD I/ II' TREE PROTECTION AREA t8 J SEDIMENT 05PoS/I5 SHOULD BE REMOKEO WHEN OEPo5175 REACH NALF INE HACHT OF NE 34WIZR ANY DO NOT ENTER SEDMENT OfPoSIIS REIWMNC. IN PFACE AFTER THE SILT ff&^C OUTLET IS R£A/OVED SMU BE DRESSED TO CONFORM 70 THE B'67ING GRADE, PREPARED AND SFEDEO. WARNING SIGN DETAIL NOTES FRONT 'A NOTES: 1. TEMPORARY DIVERSION DITCH TO BE USED TO INTERCEPT FLOW AND/OR DIVERT TO A WARNING SIGNS TO BE MADE OF DURABLE, WEATHERPROOF MATERIAL. 94/NRN4NCE SEDIMENT CONTROL MEASURE OR BMP. LETTERS TO BE 3" HIGH MINIMUM, CLEARLY LEGIBLE AND SPACED AS DETAILED, 2. SILT SHALL BE REMOVED WHEN DITCH IS ONE-HALF FULL. - STEEL POST SIGNS SHALL BE PLACED AT 50' MAXIMUM INTERVALS. /ASPECT RMPORARY ONERCON DITCH 3. DITCH SHALL BE RECONSTRUCTED WHEN DAMAGED BY EQUIPMENT OR COVERED BY WOVEN WIRE FABRIC WARNING SIGN PUCE A SIGN AT EACH END OF LINEAR TREE PROTECTION AND 50' ON CENTER THEREAFTER. ONCE A WEEK AND AFTER EYEAY R41NFAF. FI/A/EA'47EZrfiL'Y F 4. FILL. ORANGE, W RESISTANT FOR TREE PROTECTION AREAS LESS THAN 200' IN PERIMETER, PROVIDE NO LESS THAN ONE SIGN PER PROTECTION AREA ATTACH SIGNS SECURELY TO FENCE POSTS FABRIC. SEDIMENT FROM THE FLOW AREA AND STABILIZE DIVERSION DITCH BERM WITH TEMPORARY SEEDING, MULCH WITH TAC, HIGH - TENSILE STRENGTH AND REPAIR NNE DIYFR5M2N REPAb47HE AND/OR EROSION CONTROL NETTING. POLY BARRICADE FABRIC (TYPICAL) MNNTAIN TREE PROTECTION FENCE THROUGHOUT DURATION Of PROJECT. CHANNEL FINING AS NECfSWY PER ADDITIOA14L SIGNS MAY BE REQUIRED BY CITY OF RALEIGH INSPECTIONS DEPARTMENT BASED ON ACTUAL FIELD CONDITIONS. ME .WWUFACRERS INSTILMWAV WASTE MATERIAL -COMPACT, PUCE A SIGN AT EACH END OF LINEAR TREE PROTECTION AND 50' ON CENTER THEREAFTER. REQUREMENTS CRECK OU7CE/S AND SEED & MULCH AFTER - 2 MIN = 10 TREE PROTECTION FENCE AX4Kf TNZZY REPAIRS AS NEELxO 70 AREA Al TE h5y --_ I s�Npf CONSTRUCTION OF DITCH VAR. -7 C-9 NOT TO SCALE VITCH5PENAANOIDLrSTABR/ZED, I_ 2 - AXW F IHE DMRSXW AND ALL AND ?T _ STABQ2E ME CIMNNEL 70 BEYOD 477N T" "URASORfACE I `TT [� ICI �„ ICI 'WAk O VAR.2 r' 1 ,L\ 'r T III - TEMPORARY SEEDING SPECIFICATIONS/SCHEDULE 1 ICI_%I�IH Date Type Planting Rate 12' March - Oct. Browntop Millet 40 as/acre SIDE VIEW Nov. - Feb. Winter Rye 120 Ibs/acre CROSS SECTIONAL VIEW INIMUM 12 1/2 GAUGE SEEDING SPECIFICATIONS/SCHEDULE 2 TEMPORARY DIVERSION DITCH ES FOR SHOULDERS, SIDE DITCHES, SLOPES (MAX 3:1) C-9 NOT TO SCALE GRADE Date Type Planting Rate STEEL POST Aug 15 - Nov 1 Toll Fescue300 Ihs/acre WIRE FABRIC / Nov 1 - Mar I Toll Fescue & Abruzzi R e 300 Ibs acreWOVEN SEEDBED PREPARATION: Mar 1 - Apr 15 Tall Fescue 300 Ibs/acre 1. CHISEL COMPACTED AREAS AND SPREAD TOPSOIL THREE INCHES DEEP OVER ADVERSE SOIL CONDITIONS, IF AVAILABLE. SILT FENCE FABRICJul I - Aug 15 Tall Fescue & Browntop Millet 240 Ibs/acre-Tall Fescue; 2. RIP THE ENTIRE AREA TO SIX INCHES DEEP. or Sorghum -Sudan Hybrids 35 Ibs/acre Browntop Millet 30 Ibs/acre Sorghum -Sudan Hybrids 3. REMOVE ALL LOOSE ROCK, ROOTS AND OTHER OBSTRUCTIONS, LEAVING SURFACE REASONABLY SMOOTH AND UNIFORMFILL SLOPEN FOR SHOULDERS, SIDE DITCHES, SLOPES (3:1 - 2:1)4. APPLY AGRICULTURAL LIME, FERTILIZER, AND SUPERPHOSPHATE UNIFORMLY AND MIX WITH SOIL (SEE SEEDING MIXTURE). Date Type Planting Rate DE ':� M - ar 1 Jun 1 Sericea Lespedeza (scarfied) & 50 Ibs/acre (Serica Lespedeza) 5. CONTINUE TILLAGE UNITL A WELL -PULVERIZED, FIRM, REASONABLY UNIFORM SEEDBED IS PREPARED FOUR TO SIX INCHES DEEP. ° use the following combinations:"'GRADEMar 1 - Apr 15 Add Tall Fescue 240 Ibs/acre 6. SEED ON A FRESHLY PREPARED SEEDBED AND COVER SEED LIGHTLY WITH SEEDING EQUIPMENT OR CULTIPACK AFTER SEEDING. Mar 1 - Jun 30 Of add Julled Common 25 Ibs/acre 12" MIN. ANCHOR Bermuda Grass 7. MULCH IMMEDIATELY AFTER SEEDING AND ANCHOR MULCH. SKIRT Jun 1 - Sep 1 Tall Fescue & Browntop Millet 240 Ihs/acre Tall Fescue or Sorghum -Sudan Hybrids 35 Ibs/acre Browntop Millet 8. INSPECT ALL SEEDED AREAS AND MAKE NECESSARY REPAIRS OR RESEEDINGS WITHIN THE PLANTING SEASON, IF POSSIBLE. IF STAND BOTTOM OF WIRE FENCE AND 30 Ibs/acre Sorghum -Sudan Hybrids SHOULD BE MORE THAN 60% DAMAGED, RE-ESTABLISH FOLLOWING THE ORIGINAL LIME, FERTILIZER AND SEEDING RATES. FILTER FABRIC BURIED 8" Sep 1 - Mar 1 Sell Lespedeza (Unhulled- 70 Ibs acre Sericea Les deza9. VERTICALLY AND 4" HORIZONTALLY &Tali Fescue 240 ibs/acre Tall Fescue 0 EC E 0 ENTAIL ENGI EERS ON MAINTENANCE TREATMENT AND FERTILIZATION AFTER PERMANENT COVER IS ESTABLISHED. C NSULT S& NVIR NM NUnscamfied EXCAVATED TRENCH Nov 1 - Mar I Add Abruzzi a 25 Ibs/acreIN SEEDING MIXTURE: CONSULT 5&EC ENGINEER FDR ADDITIONAL INFORMATION CONCERNING OTHER ALTERNATIVES FOR VEGETATION OF DENUDEDSIDE AREAS. THE ABOVE VEGETATION RATES ARE THOSE THAT DO WELL UNDER LCAL CONDITIONS; OTHER SEEDING RATE AGRICULTURE LIMESTONE: 2 TDNS/ACRE (3 TONS/ACRE IN CLAY SOILS) VIEW COMBINATIONS ARE POSSIBLE. FERTILIZER: 1.000 LBS/ACRE - 10-10-10 SUPERPHOSPHATE: 5DO LBS/ACRE - 20% ANALYSIS TEMPORARY: RESEED ACCORDING TO OPTIMUM SEASON FOR DESIRED PERMANENT VEGETATION. DO NOT ALLOWMULCH: 2 TDNS/ACRE -SMALL GRAIN STRAW TEMPORARY COVER TO GROW MORE THAN 12• IN HEIGHT BEFORE MOWING; OTHERWISE, FESCUE MAY BE SHADED OUT.ANCHOR: ASPHALT EMULSION AT 30D GALS/ACRE A) OUTLET STRUCTURES SHALL BE UTILIZED THAT WITHDRAW WATER FROM THE SURFACE. B) FOR BASINS OR TRAPS THAT HAVE A DRAINAGE AREA OF LESS THAN 1.0 ACRE, DRAW -DOWN DESIGNS SPECIFIED IN THE DIVISION OF LAND RESOURCES OR DELEGATED LOCAL PROGRAM REQUIREMENTS ARE ACCEPTABLE, C) CHEMICAL TREATMENT: 1) ALL TREATMENT CHEMICALS MUST BE STORED IN LEAK -PROOF CONTAINERS THAT ARE KEPT UNDER STORM -RESISTANT COVER OR SURROUNDED BY SECONDARY CONTAINMENT STRUCTURES DESIGNED TO PROTECT ADJACENT SURFACE WATERS. 2) ALL TREATMENT CHEMICALS MUST BE USED IN ACCORDANCE WITH DOSING SPECIFICATIONS AND APPLICATION RATES PROVIDED BY THE MANUFACTURER, SUPPUER AND AS SPECIFIED BY THE DMSIDN OF WATER QUALITY. 3) THE PERMITTEE MUST ONLY USE CHEMICALS THAT HAVE BEEN APPROVED BY THE INC DIVISION OF WATER QUALITY AND POSTED ON THEIR "NORTH CAROLINA DIVISION OF WATER QUALITY APPROVED PAMS/FLOCCUTANTS LIST" FOUND ON THEIR WEB SITE AT: http://portalncdenr,org/web/wq/ws/su. 4) THE PERMRTEE MUST ROUTE STORMWATER TREATED WITH POLYMERS, FLOCCULANTS, OR OTHER TREATMENT CHEMICALS THROUGH SEDIMENT TRAPPING FILTERING AND/OR SETTLING DEVICES(S) TO ENSURE ADEQUATE REMOVAL OF SEDIMENT FLOCCULENT PRIOR TO DISCHARGE TO SURFACE WATERS. D) DISCHARGE REQUIREMENT - DISCHARGES MUST MEET THE STATUTORY REQUIREMENTS OF THE SEDIMENT POLLUTION CONTROL ACT AND UTILIZE THE PROVISIONS OF SECTION 6.74 OF THE EROSION AND SEDIMENT CONTROL PLANNING AND DESIGN MANUAL TO ASSURE THAT BUFFERS AND VEGETATED AREAS WILL BE USED TO REDUCE THE POTENTIAL FOR VISIBLE SILTATION OUTSIDE OF THE 25% BUFFER ZONE NEAREST THE LAND -DISTURBING ACTIVITY, ARM ASSEMBLY PERSPECTIVE VIEW PVC ELBOW PV VENT PVC END CAP PIPE WATER SURFACE PVC END CAP PVC PIPE SCHEDULE 40 1 /2" HOLES IN PVC PIPE PVC TEE UNDERSIDE FL XIHOSE END VI FRONT VIEW SKIMMER CONTACT INFORMATION J.W. FAIRCLOTH & SONS, INC. P.O. BOX 757 HILLSBOROUGH, NO 27278 919-732-1244 919-732-1266 FX - "C• ENCLOSURE WATER ENTRY UNIT PVC TEE SCHEDULE 40 PVC PIPE ORIFICE PLATE SKIMMERS SHALL BE FAIRCLOTH SKIMMERS Skimmer Basin SURFACE AREA REQUIRED 1,872 SF SURFACE AREA PROVIDED 1,950 SF VOLUME REQUIRED 2,880 CIF VOLUME PROVIDED 3,204 CIF STORAGE DEPTH 2.0 FT STORAGE ELEVATION 65 x 30 FT 485.00 TOP OF DAM 73 x 38 FT 487.00 EMGY. SPILLWAY LENGTH 10 IFT 485.50 BOTTOM OF BASIN 57 x 22 FT 483.00 SKIMMER SIZE SKIMMER SKIMMER ORIFICE ORIFICE RADIUS DIAMETER 1.5 IN 0.6 IN 1.2 IN DATA BLOCK INFLOW STRUCTURE DEWATERING ZONE - FILTER FABRIC AREA SURFACE SPILLWAY CROSS-SECTION VIEW SEDIMENT STORAGE ZONE I' FREEBOARD W=5' MIN. 6• MAX. DEPTH OF FLOW EMBANKMENT OVER EMERGENCY SPILLWAY - "IN V -� 1 T=1.5' MIN. BASIN DRAINAGE AREA ACRES DENUDED AREA ACRES) DIG BASIN VOLUME A IN U A CLEANOU DEPTH (FT.; H 2 H (FEET) Z (FEET) L (FEET) i (FEET) W (FEET) (CUBIC FT. CUBIC FIT) FT. SQ Ff. BASIN !.6 1.6 5.8 2,880 J,204 1,872 1,950 1.0 2.0 4.0 10 1.5 5.0 EMERGENCY SPILLWAY ANTI -SEEP COLLAR IENT I SENCY WAY J REFER TO DETAILS NOTES: SCHEDULE 40 FOR SKIMMER SIZE 1. BAFFLE MATERIAL SHOULD BE SECURED AT THE BOTTOM AND SIDES COUPLING CONNECTION REQUIREMENTS USING OR BY RWILLHING AS FOR FENCE. 2. MOST or THE SEEDIMENTA CUMULATE IN THE S BAY SHOULD BE READILY ACCESSIBLE FOR MAINTENANCE. 1. CLEAR, GRUB, AIFNIDASTTRIP THE AREA UNDER THE EMBANKMENT OF ALL VEGETATION AND ROOT MAT. REMOVE ALL SURFACE SOIL STANDARD SKIMMER DETAILWHICH 3. PROVIDE 3 BAFFLES (USE TWO IF LESS THAN 20 FEET IN LENGTH). PROVIDE CONTAINING HIGH AMOUNTS OF ORGANIC MATTER, AND STOCKPILE OR DISPOSE OF IT PROPERLY. HAUL ALL OBJECTIONABLE MATERIAL TO THE DESIGNATED DISPOSAL AREA, SUPPORT ROPE SUPPORT POST 4. 5 BAFFLES FOR DRAINAGE AREAS GREATER THAN 10 ACRES. BAFFLE SHALL BE 700 G/M2 COIR EROSION BLANKET. 2. ENSURE THAT FILL MATERIAL FOR THE EMBANKMENT IS FREE OF ROOTS, WOODY VEGETATION, ORGANIC MATTER, AND OTHER 84FRE MAINTENANCE TO WIRE TO 24" INTRO BOTTOM STAKE TO 5. OR SIDE TOPS OF BAFFLES SHOULD BE 2 INCHES LOWER THAN THE TOP OF THE BERMS OBJECTIONABLE MATERIAL. PLACE THE FILL IN LIFTS NOT TO EXCEED 9 INCHES, AND MACHINE COMPACT IT. OVER FILL THE INSPECT BAFFZES AT LEAST ONE A WEEK ANO AFTER PREVENT SAGGING SUPPORT WIRE \ FENCE AND FABRIC 6. INSPECT BAFFLES FOR REPAIR ONCE A WEEK AND AFTER EACH RAINFALL EMBANKMENT 6 INCHES TO ALLOW FOR SETTLEMENT. 3. CONSTRUCT THE OUTLET SECTION IN EACH RAINFALL. All -ANY REO/1RE0 REPAIRS I BURIED IN TRENCH THE EMBANKMENT, PROTECT THE CONNECTION BETWEEN THE RIP -RAP AND THE SOIL FROM /MMEO/A7ELY. PIPING BY USING FILTER FABRIC OR A KEYWAY CUTOFF TRENCH BETWEEN THE RIP -RAP STRUCTURE AND SOIL _-STEEL POST - PLACE THE FILTER FABRIC BETWEEN THE RIP -RAP AND THE SOIL. EXTEND THE FABRIC ACROSS THE SPILLWAY FOUNDATION AND BE SURE TO AAIN7AN ACCESS TO THE DUFFLES SIDES TO THE TOP OF THE DAM: OR SHOULD THE FABq/C OF A BAFFLE COLLAPSE, YEAR, P4Pr6"X6" TRENCH 1 - EXCAVATE A KEYWAY TRENCH ALONG THE CENTER LINE OF THE SPILLWAY FOUNDATION EXTENDING UP THE SIDES TO THE HEIGHT OF DECOMPOSE, OR BECOME INEFFEC7LVE, REPLACE O COMPACTED b � _ _ _ - THE DAM. THE TRENCH SHOULD BE AT LEAST 2 FEET DEEP AND 2 FEET WIDE WITH 1:1 SIDE SLOPES, 4. CLEAR THE POND AREA BELOW THE ELEVATION PROMPTLY _ OF THE CREST OF THE SPILLWAY TO FACIUTATE SEDIMENT CLEANOUT, COIR MESH OR SIMILAR, STAPLED OR __ 5. ALL CUT AND FILL SLOPES SHOULD BE 2:1 OR FLATTER, REMOVE SEDIMENT DEPOSITS WHEN IT REACHES 841F TRENCHED INTO BOTTOM OR SIDE SECTION MEW AT OPENING = _ _ _ _ - - -_ - - - _ - - 6. ENSURE THAT THE STONE (DRAINAGE) SECTION OF THE EMBANKMENT HAS A MINIMUM BOTTOM WIDTH OF 3 FEET AND A MAXIMUM SIDE FULL TO PROVIDE ADEQUATE STORAGE WLUME FOR CROSS SECTION _ _ _ - _ -_ - -- SLOPE OF 1:1 THAT EXTENDS TO THE BOTTOM OF THE SPILLWAY SECTION. THE NEXT RAN Al TO REDUCE PRESSURE ON 7HE _ _ _ � _ _ _ - - - - _ _ 7. CONSTRUCT THE MINIMUM FINISHED STONE SPILLWAY BOTTOM WIDTH, AS SHOWN ON THE PLANS, WITH 2:1 SIDE SLOPES EXTENDING TO TAKE G44E TO AVID/D LIWNTTUG THE SK/MMER 84S/N MAINTENANCE _- - - - ,= THE TOP OF THE OVER FILLED EMBANKMENT. KEEP THE THICKNESS OF THE SIDES OF THE SPILLWAY OUTLET STRUCTURE AT A 8MTZES SHOLD DURING GEED A SEDIMENT DEPTH SHOULD NEVER EXCEED EWCF THE DESIGNED INSPECT SKIMMER SEDIMENT B4SlN AT LEST WEEKLY AND AFTER EACH 5/CNIFlC4NT (ONE-HALF INCH OR CREAIER) RNNFALC EYENI AND REPAIR IMMEDAA7ECY _ = _ _ _ - _ _ _ _ _ _ _ �' -=- _- - - :�. _ _ _ - T,"': MINIMUM OF 21 INCHES. THE WEIR MUST BE LEVEL AND CONSTRUCTED TO GRADE TO ASSURE DESIGN CAPACITY. B. MATERIAL USED IN THE STONE SECTION SHOULD OULD BE DWELL -GRADED MIXTURE OFSTONE WITH A D50 SIZE OF 9 INCHES B S70R1GE DEPTH REMOVE SEDIMENT AND RESTORE THE B4SlN TO ITS ORIGINAL DIMENSIONS WHEN SEOIM£NI ACCUMULATES TO ONE-HALF 7HE HE7GNT OF THE FIRST BAFFLE. PULL = _ _ _ _ _ _ _ - _ (CLASS CONTROL STONE IS RECOMMENDED AND A ) MAXIMUM STONE SIZE OF 14 INCHES. THE STONE MAY BE MACHINE PLACED AND THE THE SKIMMER TO ONE SIDE SO THAT THE SEDIMENT UNDERNEATH IT CAN BE EXCAVATED EXCAVATE THE SEO/MENT FROM THE ENTIRE BASIN, NOT ✓UST AROUND - -_ -_ - =_ - _- - - _ SMALLER STONES WORKED INTO THE VOIDS OF THE LARGER STONES. THE STONE SHOULD BE HARD, ANGULAR, AND HIGHLY AFI£R THE CONTR1901VG DRAINAGE AREA HAS BEEN THE SKIMMER OR THE FIRST CELL MAX£ SURE VEGETATION GROWING IN THE BOTTOM OF 7HE 945IN DOES NOT HOLD DOWN THE SK/MMER _ - _ = WEATHER -RESISTANT. PROPERLY STABILIZED,, REMOVE Al 349ZE 464TERIAIS AND UNSTABLE 5E0191 DEPOSITS REPAIR THE BAFFLES /F TNEY ARE DAMAGED. RE -ANCHOR THE 84FFLLS IF WATER lS FLOWING UNDERNEATH OR AR&INO THEM 9. DISCHARGE INLET WATER INTO THE BASIN IN A MANNER TO PREVENT EROSION. USE TEMPORARY SLOPE DRAINS OR DIVERSIONS WITH OUTLET PROTECTION TO DIVERT SEDIMENT -LADEN WATER TO THE UPPER END OF THE POOL AREA TO IMPROVE BASIN TRAP EFFICIENCY, BRING THE AREA TO GRADE, AND STABIUZE 1T lF THE SKIMMER IS CLOGGED WITH TRASH AND THERE IS WATER IN THE WN, USUALLY JERKING ON 7HE ROPE WILL MAKE THE 5K/MMER BOB UP AND DOWN AND - -- 1st Cell 2nd Cell 10. ENSURE THAT THE STONE SPILLWAY OUTLET SECTION EXTENDS DOWNSTREAM PAST THE TOE OF THE EMBANKMENT UNTIL STABLE DISLODGE THE DEBRIS AND RESTORE FLOW. IF T1115 POfS NOT WORK, PULL THE SK/MMER OVER TO THE 510£ OF THE &tSN AND REMOVE lH£ DEBRIS ALSO INLET ZONE OUTLET ZONE 25% of 25% of basin 25% of basin 25% of CONDITIONS ARE REACHED AND OUTLET VELOCITY IS ACCEPTABLE FOR THE RECEIVING STREAM. KEEP THE EDGES OF THE STONE OUTLET SECTION FLUSH WITH THE SURROUNDING GROUND, AND SHAPE THE CENTER TO CONFINE THE OUTFLOW CHECK 7HE ORIFICE INS/DE THE SKIMMER TO SEE lF lT IS CLOCGED,, IF SO REMOVE THE DEBRIS surface ores surface area basin surface area basin surface area STREAM. 11, DIRECT EMERGENCY BYPASS TO NATURAL, STABLE AREAS. LOCATE BYPASS OUTLETS SO THAT FLOW WILL NOT DAMAGE THE IF THE SKIMMER ARM OR BARREL PIPE lS CLOGGGED, THE ORIFICE CAN BE REMOVED AND THE OBSTRUCTION CLEARED WITF/ A PLUMBER'S SNAKE OR BY FLUSHING EMBANKMENT. 12. STABILIZE THE EMBANKMENT AND ALL DISTURBED AREAS ABOVE THE SEDIMENT POOL AND DOWNSTREAM FROM THE TRAP IMMEDIATELY WITH WATER BE SURE ANO R50CACE THE ORIFICE BEFORE REPOSITIONING THE SKIMMER FUN VIEW AFTER CONSTRUCTION. CHECK THE FABRIC LINED SPILLWAY FOR DAMAGE AND MAKE ANY REOU/RED REPAIRS W/TH FABRIC THAT SP4A5 THE FULL W,9l OF 7HE SPILLWAY. CHECK THE 13. SHOW THE DISTANCE FROM THE TOP OF THE SPILLWAY TO THE SEDIMENT CLEANOUT LEVEL (� THE DESIGN DEPTH) ON THE PLN4S I SKIMMER BASIN EM&WKMENT, SPILLWAYS, ANO OURET FOR EROSION DAMAGE, AND /NSPECT THE EMLANKVENT FOR PIPING AND SETTLEMENT. AWE ALL NECESSARY REPAIRS AND MARK IT IN THE FIELD. 4. INSTALL POROUS BAFFLES AS SPECIFIED IN PRACTICE 6.65, POROUS IMMEDATECY, REMOVE ALL TRASH AND OTHER DEBRIS FROM THE SKIMMER AND POOL AREAS BAFFLES. C-9 NOT TO SCALE FREEZING WEATHER CAN RESULT IN ICE FORMING IN THE BASIN SOME SP£CAL PRECA0770NS SHOULD BE TAKEN IN THE Jill TO PREVENT THE SKIMMER FROM PLUGGING WITH ICE TRIANGLE SITE DESIGN z " CONSULTANT: Triangle Site Design, PLLC 4006 Barrett Drive Suite 203 Raleigh, NC 27609 (919)553-6570 mlowder@trianglesitedesign.com NC LICENSE #P-0619 SEAL: 7aL �y . SEAL "'...". l 2443g�•) '°"N1I E'car E. OWNER/DEVELOPER: GLANDON FOREST EQUITY, LLC 3900 Merton Drive Suite 210 Raleigh, NC 27609 919-459-2602 919-459-2604 fx gventers@vanguardpg.coin REVISIONS: LAYOUT COORD: MEL PLANNING MGR. M E L DRAWING BY: MEL DATE: 12/12/13 JOB NUMBER: 004063 TITLE: EROSION CONTROL DETAILS SHEET NUMBER: C - 9 COMMENTS: ._-._r -' I' 1 111 l 1, 511 9 r,l t t t BMP element: Potentialproblem: How I will remedlale the problem The entire BMP Trash/debris is present Remove the trash/debris The perimeter of the No -retention cell Areas of bare soil and/or Regrade the soil if necessary to erosive gullies have formed remove the gully, and then plant a ground cover and water until it is established. Provide lime and a one-time fertilizer application Maintain vegetation at a height 0 approximately f roximatel six Inches. 0 The inlet device: pipe, stone verge or Swale The pipe is clogged. Unclog the pipe. Dispose of the sediment off -site. The pipe is cracked or Replace the pipe. otherwise damaged Erasion is occurring in the Regrade the Swale if necessary swole. to smooth it over and provide erosion control devices such as reinforced turf matting or riprop to avoid future problems with erosion. Stone verge is clogged or covered in sediment Remove sediment and clogged stone and replace with clean stone. The pretreatment area Flow is bypassing pretreatment area and/or gullies have formed Re -grade if necessary to route all flow to the pretreament area. Restabilize the area after grading. Sediment has accumulated to a Search for the source of the sediment depth greater than three inches and remedy the problem if possible. Remove the sediment and restabilize the . pretreatment area. Erosion has occured Provide additional erosion protection such as reinforced turf matting or rip -rap if needed to prevent future erosion problems. Weeds are present. Remove the weeds, preferably by hand. The bio-retention cell: Vegetation Best professional practices show that pruning is needed to maintain optimal plant Prune according to best professional practices health. Plants are dead, diseased or Determine the source of the dying, problem: soils, hydrology, disease, etc. Remedy the problem and replace plants. Provide a one -lime fertilizer application to establish the ground cover if a soil lest indicates it is necesso Tree slakes wires are present six months after porting. Remove tree stakes wires which can kill the tree if not removed) The bio-retention cell: soils and mulch Mulch is breaking down or has floated away. Spot mulch if there are only random void areas. Replace whole mulch layer if necessary. Remove the remaining mulch and replace with triple shredded hard wood mulch at a maximum depth of three inches. Soils and/or mulch are clogged Determine the extend of the clogging. with sediment Remove and replace either just the top layers or the entire media as needed. Dispose of the spoil in an appropriate off -site location. Use triple shredded hard wood mulch at a maximum depth of three inches. Search for the source of the sediment and remedy the problem if possible, An annual soil test shows that pH has Dolomitic time shall be applied as dropped or heavy metals have accumulated recommended per the soil test and in the soil media toxic soils shall be removed, disposed of properly and replaced with new planting material. The underdrain system Clogging has occurred. Wash out the underdrain system The drop Inlet Clogging has occured Clean out the drop inlet. Dispose of the sediment off -site. The drop inlet is damaged. Repair or replace the drop inlet. The receiving water Erosion or other signs of damage have occurred at the outlet. Contact the local NC Division of Water Quality Regional Office, or the 401 Oversight Unit at 919-733-1786. RIO-RRTRNTION SOTL MIXTURE ITEM PERCENT BY VOLUME MATERIAL SAND 85%-88% CONSTRUCTION SAND FINES 8%-12% SILT ORGANIC MATTER 3%-5% COMPOST/PEAT MOSS PERMEABILITY PERMEABILITY SHOULD FALL BETWEEN I AND 6 INCHES PER HOUR, AND 1-2 INCHES PER HOUR IS PREFERRED. AND PHOSPHOROUS INDEX RANGE BETWEEN 10 AND 30 (CONFIRM WITH SOIL ANALYSIS REPORT FROM NCDA LAB) LENGTH VARIES -SEE PLANS OUTLET PIPE SHAPE OF BIO-RETENTION REFER TO GRADING PLAN AREA MAY BE IRREGULAR �CLEANOUT - - OVERFLOW OUTLET STRUCTURE. - - CLEANOUT WITH THREADED LID REFER TO HART & DETAIL FOR STRUCTURE C ET - a �caa� '6'D-a3�ire���e� o 03 AT 100 FEET MAX. HOR 2. ELEVATIONS &DIMENSIONS - � ' ' � _ � SPACING) , , _ o , p 6• SCHEDULE 40 PVC, SDR35, OR SMOOTH WALL CORRUGATED PLASTIC PIPE WITH 3/8" TOP OF EMBANKMENT GRASS SOD ENTIRE BIO-RETENTION AREA CLEANOUT WITH THREADED LID PERFERATIONS ® 6" ON CENTER (4 HOLES REFER TO CHART FOR ELEVATION (BERMUDA SOD) (AT iW FEET MAX. HORIZ. SPACING) PER ROW) GRASS SOD NOTE: GRASS SOD SHALL BE EITHER HYBRID BERMUDA GRASS OR CENTIPEDE THAT HAS BEEN GROWN IN A SOIL THAT IS FREE OF AN IMPERMEABLE LAYER (SUCH AS CLAY). BID -RETENTION SOIL MIXTURE: Blo-retention Soil Mixture (BSM): shall be placed and graded using low ground -contact pressure equipment or by excavators and/or backhoes operating on the ground adjacent to the bio-retention facility. No heavy equipment shall be used within the perimeter of the bio-retention facility before, during, or after the placement of the BSM. The BSM shall be placed in horizontal layers not to exceed 12 inches for the entire area of the bio-retention facility. The BSM shall be compacted by saturating the entire area of the bio-retention facility after each lift of BSM is placed until water flows from the under -drain. Water for saturation shall be applied by spraying or sprinkling. An appropriate sediment control device shall be used to treat any sediment -laden water discharged from the under -drain. If the BSM becomes contaminated during the construction of the facility, the contaminated material shall be removed and replaced with uncontaminated material at no additional cost to the Administration. Final grading of the BSM shall be performed after a 24-hour settling period. Final elevations shall be within 2 inches of elevations shown on the Contract Plans. The Bio-retention Soil Mixture (BSM) shall be a uniform mix, free of stones, stumps, roots or other similar objects larger than two inches. No other materials or substances shall be mixed or dumped within the bio-retention area that may be harmful to plant growth, or prove a hindrance to the planting or maintenance operations. Prior to placing the under -drain and the BSM, the bottom of the excavation shall be roto-tilled to a minimum depth of 6 inches to alleviate any compaction of the facility bottom. Any substitute method for roto-tilling must be approved by the Engineer prior to use. Any ponded water shall be removed from the bottom of the facility and the soil shop be friable before roto-tilling. Once the BSM has been placed the entire bio-retention area shall be sodded with grass that has been grown in sandy soils or that has the roots washed clean of any clay or other materials that could clog the function of the bio-retention system. OPERATION AND MAINTENANCE North Carolina storm water rules require annual inspections by the regulating agency of bio-retention areas as a minimum. More frequent inspections by the land owner or system operator are strongly encouraged to ensure the proper operation of bio-retention areas. A. Rainfall Event 1. Inspect the basin after every runoff -producing rainfoll event. B. Monthly Inspection 1. Inspect the basin monthly - 2. Check the bio-retention area side slopes; remove trash and repair eroded areas before the next rainfall event. 3. Check the vegetative and rock filters for sediment accumulation, erosion and proper operation of the flow spreader mechanism and repair as necessary. C. Quarterly P uarterl Inspection r r functioning. Clear accumulated trash from h sin pipes and Toss swales for proper I h collection system i.e. colt basin, 1. Inspect the cokc ) P P P Y . DP 9 f basin grates and basin bottoms. Check piping or obstructions. 2. Check pond inlet pipes for undercutting, replace rip -rap and repair broken pipes. 3. Reseed grossed swoles, including the vegetated filter if applicable, twice a year as necessary. Repair eroded areas immediately. D. Six Month Inspection 1. Remove accumulated sediment from the bottom of the outlet structure or other areas where accumulated sediment is noted. 2. Inspect the embankment taking note of any wet areas where water may be seeping through the soil. E. General Inspection 1. Maximum grass height is to be Bin. 2. No woody vegetation shall be allowed to grow in the bio-retention area. 3. Debris shall be removed from blocking the inlet and outlet structures and from areas of potential clogging. 4. Periodic removal of dead vegetation shall be accomplished. 5. All components of the bia-retention system must be kept in good working order. 1 BIO-RETENTION DETAILS N.T.S. PLAN VIEW FFF--- SLAB TOP WITH MANHOLE RING FOR ACCESS BERMUDA SOD POND DATA TOP OF EMBANKMENT ELEVATION = 484.4 4wrr 25 YEAR STORM ELEVATION = 484.39 10 YEAR STORM ELEVATION = 484.20 , RECIST 2 YEAR STORM ELEVATION = 483.77 P; OURET STRUCTURE 1 YEAR STORM ELEVATION = 483.55 w1TN STEPS SPILLWAY ELEVATION = 483A 1" STORM ELEVATION = 482.64 FILTER BED ELEVATION = 482A GEOTEXTILE LINING BID -RETENTION BETWEEN SO -RETENTION SOIL - '`... SOIL MIXTURE MIXTURE AND RESIDUAL SOILS (NON -WOVEN GEOTEXTILE FABRIC n WITH MIN. PERMITTVITY RATE OF 75 GAL/MIN/FT2) _ 4" WASHED SAND OUTLET BOTTOM OF SOIL MIXTURE = 480.4 PIPE DEPTH _ FILTER FABRIC AROUND VARIES BOTTOM OF GRAVEL/UNDERDRAIN = 478.9 I _ '! - UNDERDRAIN GRAVEL BED (TOP, _ __ BOTTOM AND SIDES, TYP.) (NON-WOVEN GEOTEXTILE FABRIC EXISTING SURFACE ELEVEVATION=484.0 REFER TO GRADING WITH MIN. PERMITTMTY RATE OF SEASONAL HIGH WATER TABLE DEPTH=I2FT+ PLAN FOR INVERT 75 GAL/MIN/FT2) SEASONAL HIGH WATER TABLE ELEVATION <472 ELEVATIONS 8•(MIN) UNDERDRAIN GRAVEL Top op'�OCTURL,, +B{4 �� EIEI'ATiph, ift74 REFER TO GRADING BED (M57 WASHED STONE) PLAN FOR OUTLET PIPE BIO-RETENTION CONTROL STRUCTURE 11 - '^^ `TOT CLARITY OUTLET CONTROL STRUCTURE SCALE: N.T.S. OUTLET CONTROL PIPE - REFER TO GRADING PLAN OUTLET CONTROL STRUCTURE REFER TO DETAIL THIS SHEET & GRADING PLAN REFER TO GRASS SOD NOTE THIS SHEET FOR REQUIREMENTS CLEANOUT )�O // RIM=4B9.D3.1 Q INV= BIO-RETENTION POND ue // ° / WASHED SAND I TO UNDERDRAIN PIPEIF UNDISTURBED SUBSOIL / UNDERDRAIN GRAVEL CLEANOUT BED (#57 WASHED STONE) N /I BIO-RETENTION CONSTRUCTION SEQUENCE: / / / / RIII T RIM NOTE. Step I. Construction of the bioretention area may only begin after the contributing drainage area has been / =483.1 / stabilized. It may be necessary to block certain curb or other inlets while the bioretention area is being / INV=479.3 / A PERMEABILITY SOIL REPORT SHALL BE h for existing utilities prior to on excavation. constructed. The proposed site should be checked o e sl g Les p y / PROVIDED AFTER BID -RETENTION SOIL ti MIXTURE IS IN PUCE - REFER TO Q STORMWATER MANAGEMENT NOTES FOR Step 2. Temporary E&S controls are needed during construction of the bioretention area to divert stow water U REQUIREMENTS. away from the bioretention area until it is completed. Maintain erosion control measures in place until / bioretention area has been completed. Special protection measures such as erosion control fabrics may be needed to protect vulnerable mbe side slopes; from erosion during the construction process. / o Step 3. Excavators or backhoes should work from the sides to excavate the bioretention area to its appropriate VQ NOTES: design depth and dimensions. Excavating equipment should have scoops with adequate reach so they do not / I. ALL BID -RETENTION SHALL HAVE AN ACCESS EASEMENT have to sit inside the footprint of the bioretention area. Contractors should use a cell construction approach in / REMOVABLE CAP 0 ro o° J N a &a y 6' SCHEDULE 40PVC, 10-RETENTIO N _ ) - i ro oao° SDR35, OR SMOOTH �o WALL CORRUGATED SOIL MIXTURE PLASTIC PIPE (SOLID) o � o o J CONNECTION REFER TO CHART FOR OVERFLOW OUTLET TOP OF BERM ELEVATION REFER TO DETAIL FOR GRASS SOD ELEVATIONS & DIMENSIONS (BERMUDA SOD) REFER CHART BOTTOM ELEVATION +aw rw 4 wL� +,w +o aae i n+a+Ar,L W r r J xS J � P r12*V PONDING SOIL MIXTURE STORMWATER MANAGEMENT DATA RIVER BASIN: CAPE FEAR RECEMNG STREAM NAME: BIG ALAMANCE CREEK (ALAMANCE CREEK) STREAM CLASS: WS-V, NSW STREAM INDEX: 16-19-(4.5) BIO-RETENTION: DRAINAGE AREA= 1.05AC (45,740SF) IMPERVIOUS AREA= 0.74AC (32,148SF) WATER QUALITY VOLUME REQUIRED= 2,608CF WATER QUALITY VOLUME PROVIDED= 2,885CF �iTUNMWAI'Ett MANAUEMEN'1NUTE�: 1. THE DEVELOPER OR HIS AGENT SHALL CONTACT THE ENGINEER WHEN THE BEST MANAGEMENT PRACTICE($) ARE CONSTRUCTED AND ABOUT TO BECOME OPERATIONAL SO A FINAL INSPECTION CAN BE PERFORMED TO DETERMINE COMPLIANCE WITH THE APPROVED PLAN CAN BE PERFORMED. 2. PRIOR TO CONSTRUCTION, A SOIL TEST OF THE BID -RETENTION FILTER MEDIA SHALL BE REVIEWED AND APPROVED BY THE ENGINEER OF RECORD WITH A COPY SENT TO THE ENGINEER. THE TEST SHALL CONSIST OF BOTH THE STANDARD SOIL TEST FOR pH, PHOSPHORUS, MAGNESIUM, AND POTASSIUM AND ADDITIONAL TESTS OF ORGANIC MATTER, AND SOLUBLE SALTS. ALL TESTING RESULTS SHALL COME FROM THE SAME TESTING FACILITY. THE NC F DEPARTMENT E 0 AGRICULTURE NCDA LAB IS THE PREFERRED TESTING FACILITY. SHOUL D THE pH FALL OUT OF THE ACCEPTABLE RANGE, IT MAY BE MODIFIED (HIGHER) WITH LIME OR (LOWER) WITH IRON SULFATE PLUS SULFUR OR AS DIRECTED BY THE NCDA OR ENGINEER J. PRIOR TO CONSTRUCTION A COMPOSITION TEST OF THE BID -RETENTION FILTER MEDIA SHALL BE REWEWED AND APPROVED BY THE ENGINEER OF RECORD WITH A COPY SENT TO THE ENGINEER FILTER MEDIA SHALL CONFORM TO THE FOLLOWING: 85-889 SAND (USDA TEXTURAL CLASSIFICATION), 8-12% FINES (SILT AND CLAY), AND 3-58 ORGANIC MATTER (PEATMOSS OR PINE BARK) BY VOLUME 4. PERFORM A DOUBLE RING INFILTRATION TEST (MINIMUM OF 3 TESTS OR I PER 500 SF OF FILTER MEDIA WHICHEVER IS GREATER) AT THE COMPLETION OF THE BID -RETENTION BMP. INFILTRATION RATE OF THE CONSTRUCTED BID -RETENTION MEDIA SHALL BE BETWEEN 1-6 IN/HR. PROWDE A COPY OF THE RESULTS TO THE ENGINEER. 5. ANNUAL MAINTENANCE INSPECTION AND REPORT REQUIRED - THE OWNER OF A PERMITTED STRUCTURAL STORMWATER BMP/CONTROL SHALL ANNUALLY SUBMIT A MAINTENANCE AND INSPECTION REPORT FOR EACH BMP TO THE STORMWATER ADMINISTRATOR. ANNUAL INSPECTIONS SHALL BEGIN WITHIN ONE YEAR OF THE RECORDATION OF ANY DEED(S) SHOWING STORMWATER BMPs/CONTROL STRUCTURES. 6. UPON COMPLETION OF THE PROJECT, AND BEFORE A CERTIFICATE OF OCCUPANCY SHALL BE GRANTED, THE ENGINEER OF RECORD SHALL CERTIFY THAT THE COMPLETED PROJECT IS IN ACCORDANCE WITH THE APPROVED STORMWATER MANAGEMENT PLANS AND DESIGNS, Z A FINAL INSPECTION OF THE SITE AND STORMWATER MANAGEMENT BMP/CONTROLS TO BE SCHEDULED WITH AND COMPLETED BY THE ENGINEER & INSPECTOR. 8. THE ENGINEERS CERTIFICATION OF COMPLETION WILL BE REQUIRED PRIOR TO THE FINAL PUT OR CERTIFICATE OF OCCUPANCY THE STORMWATER CONTROL IS TO BE INSPECTED TO ENSURE IT IS FUNCTIONING AS DESIGNED AND HAS FULL DESIGN VOLUME PRIOR TO ISSUANCE OF THE FINAL CERTIFICATE OF OCCUPANCY BIO-RETENTION STAGE STORAGE TABLE STAGE ELEVATION CONTOUR INCREMENTAL TOTAL (FT) (FT) AREA (SF) STORAGE (CF) STORAGE (CF) 0.0 482.4 2585 0 0 0.6 483.0 3250 1839 1839 1.6 484.0 3920 3579 5419 1.0 484.4 4210 1625 7044 If 24e4sepi SS 01 / P / 39h INLET PIPF/VIITH / RI -RAP' APRON W � / �/ r• ,Y p 6• UNDERDRAIN / yr _CI d / l D + r• j140D . -- / / STORMWATER r• / "a'. Lw, / /MANAGEMENT Y r• r• w• r• / ! EASEMENT �' / / W . • • RIM 483 / W W , \ t^1' W • Y W INV=479.3 / RIP-RAPE WITH APRONAPRON / W W\ W \ W • W W ♦ Q W W // sl/ `V 41 14, \ i \ r/y / W/ Wy y. Y /V V/ VI V/ V/ 41 W LEANDUT / w 14, %1,/ �J" h WV=4479.3 l l W r 1 I \V 41 1/ / y / / V V• W I• `Y `L '4"/ -4,/ II v),Y' /j/' \yi -L�•Z6 k% W / � W � W W i i i W iV /\ I/ Y/• /"'444 /,Y' J N W �.Y W W W W W J W W W `Y `Y / W W W W W W W W W W ♦ �� J W/ � •T � �� � r- -W � W- y' ✓/ / ✓ 'Y W W `Y !' `Y W W W W y W y V, 'Y W W J' W W ♦ w v�Y CONNECTING TO A DEDICATED PUBLIC RIGHT OF WAY, larger bioretention basins, whereby the basin is split into 500 to 1,000 sq. ft. temporary cells with a 10-15 e in between, so that cells can be excavated from the side. 9 \ foot earth bridge 2. DRAINAGE AREAS TO ABID-RETENTION FACILITY ARE TO TO BE STABILIZED PRIOR TO INSTALLATION OF SOILS OR Step 4. It may be necessary to rip the bottom soils to a depth of 6 to 12 inches to promote greater GRASS SOD. infiltration. , / •` / / /� / / 3. WRAP PERFORATED UNDERDRAIN WITH FILTER FABRIC Step 5. Place geolextile fabric on the sides of the bioretention area with a 6-inch overlap on the sides. Place ✓/ / \� / /- PRIOR TO 8ACKRLUNG. the appropriate depth of stone on the bottom, install the perforated underdroin pipe, place stone above the underdrain pipe, and add sand layer between the underdrain and the soil media layer. 4. UNDERDRAIN PIPE SHOULD HAVE 3/8• PERFORATIONS SPACED AT 6' CENTERS, MIN. 4 HOLES PER ROW. MAX Step 6. Deliver the soil media from an approved vendor, and store it on an adjacent impervious area or plastic SPACING OF UNDERDRAIN PIPE IS 10 FEET ON CENTER. sheeting. Apply the media in 12-inch lifts until the desired top elevation of the bioretention area is achieved. Wait a few days to check for settlement, and add additional media, as needed, to achieve the design elevation. 5. UNDERDRAIN CLEANOUTS MUST EXTEND A MIN. OF 6 INCHES ABOVE TOP SURFACE OF GRASS LAYER, Step 7. Install the vegetation, and water accordingly. PREFERABLY TO THE TOP OF DESIGN MAXIMUM PONDING DEPTH IN THE 810-RETENTION BASIN, Step 8. Coordinate with inspector and engineer to conduct the final construction inspection. Upon completion of bioretention facility remove temporary erosion control measures and complete final stabilization of the project. W �W W W W W W W� W W W W/ WV ♦ ♦ W�1 W W W W W W W W W /W/ W W W W ♦ W W W W W W -T .Y O W W W W T� I�.� y..�W1.' J. W 1. •T. / /VWJJ/\�!�V J. .l. W rY/WW W 1 WVD y.W W W W W . W W ... �-W V,. W J' WW + ..YY/vo Y W /W /// .Y y'W W�`'Y✓ W M.Y� •WY W 4 W W W W W Y 'Y will T �w� T wwwy� T �iw� ��� r ��� wY +r rY +✓GYi wY� / TOP OF EMBANKMENT ELEV=484.4 BID -RETENTION BASIN - PLAN VIEW 1"=15' i TRIANCI - SITE I�ESI�.N CONSULTANT: Triangle Site Des ign, I7 ILC I 4006 Barrett Drive Suite 203 Raleigh, NC 27609 (919)553-6570 mlowder®trianglesitedesign.coir, NC LICENSE #P-0619 SEAL: ��••��r�5uv .I z443q.j ' 11V i �J I OWNER/DEVELOPER: GLANDON FOREST EQUITY, LLC 3900 Merton Drive Suite 210 Raleigh, NC 27609 919-459-2602 919-459-2604 fx gventers@vanguardpg.com REVISIONS: Ira: r F mrI wrntm rnnstruc, r cordance wnI nose documenttss 1h required by tn., s ormwaterpelUd! Ilorth odes require that the St system designer Inspect during construction hy -, certify GOnf0rmWith the nits ecsi and certify camptiance with the Stornlwater rules. p_ Permit:i,5 /3 03_Date� billl N DWlsion of I.neet - «wlsiAna-r -_ LAYOUT COORD: MEL PLANNING MGR. MEL, DRAWING BY: MFL DATE: 1_, 1. 1. JOB NUMBER: 004063 TITLE: STORMWATER MANAGEMENT DETAILS SHEET NUMBER: C 10 COMMENTS