Loading...
HomeMy WebLinkAboutWQ0044269_Drawing_20230927ACES FOR AUTISM RECORD DRAWING FOR PHASE 1 SANITARY SEWER IMPROVEMENTS Legend: EXISTING PROPOSED o EIP — EXISTING IRON PIPE o ERB — EXISTING RE —BAR R/W — RIGHT OF WA Y C/L — CEN TERL INE R/R — RAIL ROAD RCP— REINFORCED CONCRETE PIPE CMP— CORRUGATED METAL PIPE E/T — ELECTRIC TRANSFORMER Q F/H — FIRE HYDRANT FH H W/V - WATER VALVE N - WATER METER • WM O/H - 0 VERHEAD - FIRE DEPARTMENT CONNECTION FDIC - POST INDICA TOR VAL VE PIV PAP - POWER POLE + 72.14 - EXISTING SPOT ELEVA TION - CONTOUR LINE 70 THY - TEMPORAR Y BENCHMARK - - oHE - - - - OVERHEAD POWER LINE - CA TCH BASIN a - SANITARY SEWER CLEANOUT cow - SANITARY SEWER MANHOLE - SANITARY SEWER MAIN/SERVICE — s - WA TER MAIN / SER VICE - W - FIRE MAIN F - SIL T FENCE SF - LIMIT OF DISTURBANCE LOD - TEMPORARY DI VERSION DI TCH TDD - 4' CHAINLINK FENCE - STORM DRAIN DEMOLISH / REMOVE CONCRETE 4e ° DEMOLISH / REMOVE GROUND ELEVA TION X PG 22.00 TOP OF CONCRETE X TIC 22.00 TOP OF ASPHAL T X TA 22.00 TOP OF BACK OF CURB X BC 22.00 SPILL CURB INLET PROTECTION WORTHINGTON ROAD ^I WINTERVILLE TOWNSHIP � PITT COUNTY � NORTH CAROLINA I I I \ r \ V 7- -L+--- I t L - -L - - ---� L I COOPER STREET—L — J L ion I BAYBERRY LANE I �- / RECORD DRAWING NOTES: 1. CENTERLINE MH TO CENTERLINE MH DIMENSIONS SHOWN ON SANITARY SEWER IN PLAN VIEW. WALL TO WALL DIMENSIONS SHOWN IN PROFILE. 2. SANITARY SEWER SERVICES STATIONED FROM MANHOLE TO MANHOLE PROGRESSING UPSTREAM. 3. ALL SEWER SERVICES ARE 6" PVC. CLEANOUTS INSTALLED ON THE ENDS OF ALL SERVICES. 4. ALL SANITARY SEWER MAINS ARE PVC SDR-35 UNLESS OTHERWISE NOTED. 5. INFORMATION ON THE SANITARY SEWER IMPROVEMENTS WAS GATHERED AND PROVIDED BY MATRIX EAST, PLLC AND DRAWN UNDER THE SUPERVISION OF BRYAN C. FAGUNDUS, P.E. AND IS CORRECT TO THE BEST OF MY KNOWLEDGE AND BELIEF. 6. THIS DOCUMENT WAS ORIGINALLY ISSUED AND SEALED BY BRYAN C. FAGUNDUS, P.E. ON APRIL 13, 2022 AND LAST REVISED ON JULY 10, 2023. THIS DOCUMENT SHALL NOT BE CONSIDERED A CERTIFIED DOCUMENT AS TO THE ORIGINAL DOCUMENT BUT ONLY AS TO THE SANITARY SEWER RECORD DRAWING INFORMATION SHOWN HEREON. Engineer Ark Consulting Group, PLLC 2755 Charles Blvd - Suite B Greenville, NC 27858 (252) 558-0888 V) z —Ju SIR 1711_ LU WORTHINGTO o N RD. > 0 p CL O c F 0cc a w p LLJ 0 SITE w z O 0 za � N U Cr O U Lu C7 z_ a 0 O v SR 1713 - LgURIE ELLIS RD. w m N w H LU � � C] Site Data Vicinity Map SCALE: 1" = 1000' TOTAL ACREAGE IN SITE: 23.372± AC TOTAL ACREAGE IN PHASE 1: 13.89 AC TOTAL ACREAGE IN FUTURE PHASES: 9.48 AC TAX PARCEL NUMBER: 14643 NC PIN NUMBER: 4684194122 CURRENT ZONING: OI TOTAL GROSS FLOOR AREA: 63,028 SF GROSS FLOOR AREA PHASE 1: 31,253 SF GROSS FLOOR AREA FUTURE: 31,775 SF TOTAL BUILDING LOT COVERAGE: 0% EXISTING / 6.2% PROPOSED BUILDING LOT COVERAGE PHASE 1: 3.1% BUILDING LOT COVERAGE FUTURE: 3.1% BUILDING HEIGHT 20'-6" TOTAL NO. OF PARKING SPACES REQUIRED: 55 SPACES (INCL. 10 H/C) TOTAL NO. OF PROPOSED PARKING SPACES: 196 SPACES (INCL. 10 H/C) PROPOSED PARKING SPACES PHASE 1: 148 SPACES (INCL. 6 H/C) PROPOSED PARKING SPACES FUTURE: 48 SPACES (INCL. 4 H/C) TOTAL SQ. FEET OF EXIST. IMPERVIOUS AREA: 0 SF TOTAL SQ. FEET OF PROPOSED IMPERVIOUS AREA: 264,395 SF (26.0%) PROPOSED IMPERVIOUS PHASE 1: 163,935 SF (16.1%) PROPOSED IMPERVIOUS FUTURE: 100,460 SF (9.9%) DISTURBED ACREAGE: 23.37 AC. REFERENCES: D.B. 3729, PG. 230-235 M.B. 78, PG. 16 M.B. 45, PG. 156 Parking Requirements: PARKING REQUIRED: ELEMENTARY AND MIDDLE SCHOOL OFFICE SPACE: 5 SPACES+ 1 SPACE/STAFF MEMBER 55 SPACES REQUIRED HANDICAP PARKING: 10 SPACES Sheet List Table # Sheet Title Survev Note: BOUNDARY AND TOPOGRAPHIC INFORMATION SHOWN HEREON WAS PREPARED BY GARY S. MILLER & ASSOCIATES, PA., AS SHOWN ON DRAWING ENTITLED BOUNDARY AND TOPOGRAPHICAL SURVEY FOR ACES FOR AUTISM, DATED NOVEMBER 29, 2018, ATTACHED TO THIS DRAWING SET FOR REFERENCE. Owner / Developer Kyle Robinson 925 Conference Dr. Greenville, NC 27858 (252) 689-6645 150' 0 75' 150' SCALE 1 inch = 150 ft REVISIONS: Q 0 W V ._0) O U I` O r z � � Q L,L LU U O v > z, O Ov -0 � o o U) -0 LL I QO M 8 81 z a lj w ` r J z aQ °u D z V1�U) w z O w E Owze Q VLDw 00 ° -6 LI) O .0r\ CON oo v U 000 '-zoo N U cro-0 co O -'-U U v 00 p co > Ln7a co N VCV D / �01"11#u1141' \A R0 31970 ; - �/G/ZOZ3 Project Manager: BCF Drawn By: CED Checked By: STA Project Number: 21066 Drawing Number: D-1231-RD C1.0 Contact: Bryan C. Fagundus, PE bryan@arkconsultinggroup.com Contact: Kyle Robinson Date: 04-13-2022 0 0 � a D D KNOW WHAT'S BELOW CALL BEFORE YOU DIG! 1-800-632-4949 WWW.NC811.ORG z w 0 a LL, z w 0 V z d a � U U) O J2 U) C7 z_ a 0 0 0 v w MATCHLINE - SEE SHEETC5.1 M N LLl H � I I 1 I w °° ° \ I I I o I 1 w • ° I � ° I I I \ I I — G \ Q oo \ I I N I I Xk I I AV I I '�\ \ V II � I I II I I REVISIONS: 1 ° G\ o I\ I I I I II 10"x10"TEE � STORM WATER I I I 3 EA. 10" GV . CONTROL MEASURE \ I I I I (IN SEALED I I 10"x6" HT ROADWAY BOXES) \ \\ \ \ I v I I \ I I I 11 N \ I I I 6" GV (IN SEALED ROADWAY BOX) I S I I \ I FH W/ STORZ (NOZ. ELEV. 21"' I 2 - 10" 45° BENDS. \ \ 0 I I II U- I I \ I I I ABOVE ADJ. GRADE) I F I \ 4 \ \ I I I I Q I 10" 22.5° BEND , O \ ss \ \ S W W o\ \ \ \ 11 I I I II 61 F \ S3 S� 6\ \ \ s I I I 1 1 I V I 62 10" WATER TO 10" z I I \ II Q F CROSS BELOW p \ I I N STORM PIPE 1 ° \ 62 (REFER TO DETAIL) 'lye \ \ \ N I I I \ I 0 V \ EX-SSMH5 \ 1 \ 1 63,, A 62 V \ RIM 53. 00 V A y 1 A \ PROPOSED GAS SERVICE (BY Q t \ \ \ \ IN . 38.91 (S) \ \ \ \ \ 1 \ 1 GUC UPON APPLICATION & 10" 22.5' ° 63 63 o INV. 59.01 (NE) 1 1 PAYMENT OF FEES) BEND \ \ \ \ o \ \ 11 : \ \ \ \ \ \ \ \ \ \ \ \ p \ F \ ♦ \ \ \ \ \ \ 1 vS a \ \\ D bJ _LNEIVMEIS1 t V A \ ° z ° s1 10" 11.25° BEND �� A \V A A 11 \ \ 1 (6 \ \ V A \ s.A RESTRAINED JOINT I \ \ \ ^ z \ (60 LF (MIN.) 9 -- \ \ \ Na \ \ \ 1 U) L FROM 10" GV) 10"x6" HT \ k \ 3 \ 10" GV \ \ \ 1 2 \ \ U o \ 84 so 6° GV \ \ \ \ \ �\ N ° (GV IN SEALED \ \ ° o \ 4" 4$° De o \ \ \ � \ ` � � L r BEND W O z ' ROADWAY BOXES) \ \ \� 1 \ \ \ FH W/ STORZ \ \ \ 1 Z M (NOZ. ELEV. 21" ABOVE \ \ \ \ \ \ 1 \ O n/ \ ° > 64 ° ° y I ADJ. GRADE) N C/ 64 10'x6 TEE 2 EA. - 10 GV ` ° D • \ \ N\ \ \ U (� I (IN SEALED \ ° \ ° ' ° ° \ I I I ROADWAY \ \ e \ , \ \ 4 x4 TEE Q' / \ \ \\ \ � J BOXES) \ \ ° , \ 3 EA.- 4" GV °uk o I \ \ (n �I I 10" 22.50 D > e�D\ \ e \ \ p / II V / °L v \ \ \ \ `\ \ \•\ � O 4 1 / BEND O p \ \ \ J 10"x6" HT G pL ° o D ° ° REFER TO MEP \ A �(� / I \ \ \ \ O \ \ \ /I 6" GV (IN SEALED ROADWAY BOX) PLANS FOR CONNECTION 4 45° FH W/STORZ (NOZ. ELEV. 21" !j ° \ ABOVE ADJ. GRADE) �F •D 0 0 0 \ BEND a / I \\ \ \\ \ \�O \ Lu O —_ ° e ko I I I ° F > FREE STANDING FDC CONTRACTOR �SSCO 101 � \ \ SITE UTILITY \ ��\ ° `O \ ° ° � , \ ,�, \ \ \ \\ \ \ \ \• O \ WITH STORZ D° D TO STUB FIRE SP INKLER RISER \ A ° 6" PVC FDC DRY PIPING 1 FT ABOVE FFE WITH A BLIND FLANGE. STA. 1+81 ° . � COORDINATE WITH MEP PLANS FOR INV. 60.36° ° H o \ a, ID I \ \ LOCATION OF FIRE SPRINKLER AND \ SSCO-100 FDC PIPING WITHIN BUILDING. \ STA. 0+78 \ I I \ \ \ \ \ \ INV.56.73 V 'SSMH-5 a A V A \ \ • RIM I6r.22r (62.77) \ \ \ \ INV. 52: '6 (SSCO-100) (52.59) ° I ■ \ \ \ \ \ \ OUT _r c (SSMH-1) e 0 ° a a D ' e I v ° ° •r 4" PVC STq, 0+0 10,x6" HT / D ° De DOMESTIC \ \ I I I ■ \ \n 6" GV (IN SEALED ROADWAY BOX) ° �/ 6�/ WATER 3 I \ I aCo z I FH W/ STORZ (NOZ. ELEV. 21" \ I I \ \ \ \ \ a J w ABOVE ADJ. GRADE) \ \ I \ \ S 8,, I \ \ \ \ L J d a \ \I I II I II I °a a \ vi E z FIRE APPARATUS (159Z Oz� 10"11.25° ACCESS ROAD (PH. 1) g` pv%, O BEND W 0 6S. 00 li aQo EX-ssMH „90' � r-C RIM �(54.48)CO — I�DI / °^ ° V v ° e D° Q D BEND ° I I , / /� / a° . a \ INV. 3�2'(EX-SSMH3)J(38.31) \\ �� a v 0o00 / /(III ° ° ° e I ° ° INV. 4sx86(SSMH-1) (38.42) z o 0 0 / A ° as °• °° D° o SSMH\1 \ L N ' U RIM 56:27 (56.11) INV. 3832'(EX-SSMH5), '(38.37) \ m INV. AQ-n (SSMH_5) (49.80) /� \ Ln N 3 ° INV. AQ-e6 (SSMH 2) (49.77) Ln Ln v L > D „ / N I c, av 1 4 90° ° OUT (EX -SS 49.7 N C7 3 11Y3G GAS METER � � °Q ( ) ( ) � \ I ° ,BEND G C' G D I c� / -�A1111111//I LL • ` D I MATCHLINE-SEE SHEETC5.3 - L 31970 = RECORD DRAWING NOTES: 1. CENTERLINE MH TO CENTERLINE MH DIMENSIONS SHOWN ON SANITARY SEWER IN PLAN/�/ZOZ3 VIEW. WALL TO WALL DIMENSIONS SHOWN IN PROFILE. 2. SANITARY SEWER SERVICES STATIONED FROM MANHOLE TO MANHOLE PROGRESSING UPSTREAM. Project Manager: BCF 3. ALL SEWER SERVICES ARE 6" PVC. CLEANOUTS INSTALLED ON THE ENDS OF ALL SERVICES. Drawn By: CED 4. ALL SANITARY SEWER MAINS ARE PVC SDR-35 UNLESS OTHERWISE NOTED. 5. INFORMATION ON THE SANITARY SEWER IMPROVEMENTS WAS GATHERED AND PROVIDED Checked By: STA BY MATRIX EAST, PLLC AND DRAWN UNDER THE SUPERVISION OF BRYAN C. FAGUNDUS, P.E. Project Number: 21066 AND IS CORRECT TO THE BEST OF MY KNOWLEDGE AND BELIEF. 6. THIS DOCUMENT WAS ORIGINALLY ISSUED AND SEALED BY BRYAN C. FAGUNDUS, P.E. ON Drawing Number: D-1231-RD APRIL 13, 2022 AND LAST REVISED ON JULY 10, 2023. THIS DOCUMENT SHALL NOT BE CONSIDERED A CERTIFIED DOCUMENT AS TO THE ORIGINAL DOCUMENT BUT ONLY AS TO THE SANITARY SEWER RECORD DRAWING INFORMATION SHOWN HEREON. 30' 0 15' 30' G502 SCALE 1 inch = 30 ft Date: 04-13-2022 z Uj 0 MATCHLINE - SEE SHEET C5.2 `S A O e or73 328-YI 325-YI • ' � � a � � w ap / 233 YI 329 RD . • % g n K / w `n 0 � ;'� � in °D ° d • 332-YI m � 1O 11 \ Z ° e a D • 330 CO Lo — \ Z m F en• D ° $ 327-CO 326 YI \ < I 1D ° 10" GV IN SEALED _ — ° D f D SSMH-2 \ - � �p 6 — — — — — _ - , ° / �`� /6 RIM b� 13 (62.86) ROADWAY BOX o \ \ ° \ o / INV. 52<@6(SSMH 3) (51.97) \ v sr / FIRE APPARATUS a a w s4� INV. 5738(SSCO-200) (57.05) / 3D ° ACCESS ROAD (PH. 1) " \ �/— — — - / �� — — — — OUT 51:86(SSMH-1) (51.85) \ r,) A 242YI \ N W LU / a D �° / /°� ° \° \ REVISIONS: Uj 10"x6" HT CC 10" PLUG 6" GV IN SEALED ROADWAY BOX ° . ° FH W/ STORZ (NOZ. ELEV. 21" ° D 334-YI a 00 \ \ ABOVE ADJ. GRADE) A ° _ o D o 236-Y ° 240-YI D CL v c I Z 3S`dHd REFER TO MEP PLANS D° ° D \ \ \ D ° 337-YI D ° \ . ° � ti � � Q FOR CONNECTION �o`'allo \ 0 PH P PH • °° - o \ io • __ O O' a a U LL 3 ,� - - - - � ° o N �A m m, / 6� a 237 YI Q2 _ _ \ \ � A LLI ° a V REFER TO MEP PLANS •� \ FOR CONNECTION TO \ \ \ \ Q I I EQUIPMENT SSCO 303 SPLASH PAD E \ CZ 338-YI ° STA. 1+90 \ ° 243-YI —I 239 YI . INV. 56.73 \ - SSCO-305 2 PV4" 22.5° BEND SSCO-306 STA. 2+73 k, WATEC R SERVICE \ STA. 3+01 INV. 59.09 INV. 63.11 D • I ° \ I I I I � � \ � -� A • °, a�, 339-YI � � - ° A 238 YI G S I \ 51P• D _ SSC0-302 • , III I 4 GV \ SS CO 301 \ \ I \ o c;• 1" PVC WATER ICE �L � ° \ \ 4' x2' TEE ° REFER TO MEP PLANS STA. 1+58 STA. 0+76 244-YI _ \ _ � • 340-YI I \ I I I /A ♦ SSCO 300 2 BV 1 \ INV.55.61 ° FOR CONNECTION - - _ — 4' x2 REDUCER I STA. 0+22 `` \ \ I� y I 246-YI — 2 x1 TEE \ ` INV. 54.92 RIM H 245 J32-9S (62.45) ' . \ \ \ \ • E -Yco 2" BV I \ II I I I SSCO-304 1" BV INV. \ / INV. 54!96(SSMH-4) (54.66) \ \ \ J I • W ° ` ° STA. 2+21 2 EA - 2" BV \ " INV. 54-86 (SSCO-300) (54.66) \ \ \ DW ., W INV. 57.15 2"x2" TEE a ° s \ OUT 54-76(SSMH-2) (54.64) \ \ \ \ 206 CB \ — N )♦ ASE 1 2"x1" REDUCER \ ° \ \ \ U). _ O I ■ 111 BV 8 \ \ \\ \ \ \ U -11 v \ I \ \ \ M \ i 1" PVC WATER SERVICE ° ° \ \ \ \� ��, \ \ W � ti O SANITARY SEWER\ s s \ \ NOT CONSTRUCTED SSMH 4 \ WITH PHASE 1 VJ O s ° \\ 1 \\ \ \ U U III a \\ \ \ a_ 1E \ a \ A LL M rn 63 40 4--' > Ez \ Q L 208-FES-7� U � n W R Cc gnIc 1%,2 W J O ~ m Q 0 0 � a D D KNOW WHAT'S BELOW CALL BEFORE YOU DIG! 1-800-632-4949 WWW.NC811.ORG 81 to p) vJ Zj) a ` J w r J z J as � J z V / E ZOW W U 0 Q U L7' w � to > 00 b,0 � U 0000 :3 =Z00 M O DD Y 00 > � M N N 3 Ln i! Lr) NCDN �,--\\ACARO'�. L 31970 = C. F D 1. CENTERLINE MH TO CENTERLINE MH DIMENSIONS SHOWN ON SANITARY SEWER IN PLAN/G/ZOZ3 VIEW. WALL TO WALL DIMENSIONS SHOWN IN PROFILE. 2. SANITARY SEWER SERVICES STATIONED FROM MANHOLE TO MANHOLE PROGRESSING UPSTREAM. 3. ALL SEWER SERVICES ARE 6" PVC. CLEANOUTS INSTALLED ON THE ENDS OF ALL SERVICES. 4. ALL SANITARY SEWER MAINS ARE PVC SDR-35 UNLESS OTHERWISE NOTED. 5. INFORMATION ON THE SANITARY SEWER IMPROVEMENTS WAS GATHERED AND PROVIDED BY MATRIX EAST, PLLC AND DRAWN UNDER THE SUPERVISION OF BRYAN C. FAGUNDUS, P.E. AND IS CORRECT TO THE BEST OF MY KNOWLEDGE AND BELIEF. 6. THIS DOCUMENT WAS ORIGINALLY ISSUED AND SEALED BY BRYAN C. FAGUNDUS, P.E. ON APRIL 13, 2022 AND LAST REVISED ON JULY 10, 2023. THIS DOCUMENT SHALL NOT BE CONSIDERED A CERTIFIED DOCUMENT AS TO THE ORIGINAL DOCUMENT BUT ONLY AS TO THE SANITARY SEWER RECORD DRAWING INFORMATION SHOWN HEREON. Project Manager: BCF Drawn By: CED Checked By: STA Project Number: 21066 Drawing Number: D-1231-RD C53 30' 0 15' 30' SCALE 1 inch = 30 ft Date: 04-13-2022 z LU 70 70 'o a z w 0 V z d a V U = U) 0 Uj CU)7 z_ 65 65 0 0 0 U m N W H � d Q LUGRADE PROpnccri REVISIONS: 60 60 52 Q 55 55 mar. K4jkr 0 W U Q 50 50 Co 45 45 Cn.� co U SEE SF EET C7.1 r Cl) � ti o LU z 40 40 J LL O � U v a z 0 -0 1E Lim o 35 35 p -0+50 0+00 1+00 2+00 3+00 4+00 5+00 5+50 Wo 4--+ > Qo 70 70 65 65 81 Z rt GRADEa ` J w r J z J as J -------------- 06 U ( / 0 E ZOW W U O 'A/ zCVlrTlKlr- Q UQz � � to 60 60 00 00 a U 00 N C e I U M 0 Y Co � c6 `n v L 3 f V (D N 55 55 \A CARO''' L 15 31970 �/G/ZOZ3 50 5o RECORD DRAWING NOTES. Project Manager: BCF 30' 0 15' 30' Drawn By: CED 1. CENTERLINE MH TO CENTERLINE MH DIMENSIONS SHOWN ON SANITARY SEWER IN PLAN Checked By: STA VIEW. WALL TO WALL DIMENSIONS SHOWN IN PROFILE. 0 2. SANITARY SEWER SERVICES STATIONED FROM MANHOLE TO MANHOLE PROGRESSING Project Number: 21066 SCALE 1 inch = 30 ft UPSTREAM. Drawing Number: D-1231-RD V E RT. 1 inch = 3 ft 3. ALL SEWER SERVICES ARE 6" PVC. CLEANOUTS INSTALLED ON THE ENDS OF ALL SERVICES. 4. ALL SANITARY SEWER MAINS ARE PVC SDR-35 UNLESS OTHERWISE NOTED. 5. INFORMATION ON THE SANITARY SEWER IMPROVEMENTS WAS GATHERED AND PROVIDED a BY MATRIX EAST, PLLC AND DRAWN UNDER THE SUPERVISION OF BRYAN C. FAGUNDUS, P.E. AND IS CORRECT TO THE BEST OF MY KNOWLEDGE AND BELIEF. 45 45 6. THIS DOCUMENT WAS ORIGINALLY ISSUED AND SEALED BY BRYAN C. FAGUNDUS, P.E. ON C5A KNOW WHAT'S BELOW -0+50 0+00 1+00 2+00 3+00 4+00 5+00 5+50 APRIL 13, 2022 AND LAST REVISED ON JULY 10, 2023. THIS DOCUMENT SHALL NOT BE CALL BEFORE YOU DIG! CONSIDERED A CERTIFIED DOCUMENT AS TO THE ORIGINAL DOCUMENT BUT ONLY AS TO 1-800-632-4949 THE SANITARY SEWER RECORD DRAWING INFORMATION SHOWN HEREON. WWW.NC811.ORG Date: 04-13-2022 APPROXIMATE FINISH GRADE (PH. 2) - - - - EXISTING - � GRADE 4 DOMESTIC WATER ° SSCO-101 OUT 5Y2'4 (SSCO-100) (60.36) ' 30" CP 10" WATER (PH. 2) VFl \5' `��9� @ SSCO-100 INV. 5br77(SSCO-101)-(56.73) OUT 5�-77 (SSMH-5) 15" PVC ° (56.73) I I I I I I 110� �g LFl LF VC" l2 4�%1 SSMH-5 RIM 6g:2� INV. 52:76 (SSCO-100) OUT .52crS5 (SSMH-1)—(52.46) (62.77) (52.59) 1155.831F1-11 g3%1 @ SSMH-1 RIM 56�27 (56.11) INV. A9c8b (SSMH-5) (49.80) INV. 4sJ-8'6 (SSMH-2) (49.77) OUT 49-7G (EX-SSMHS) (49.71) I I $, pV I ' (DROP INV. 46.71) I I I DROP ER PROPOSED APPROXIMATE FINISH GRADE(PH.2) '---'"-- _ _ --'---- GRADE _ _ — _ — 8 STUB W/CAP THIS pHASE) (NOT INSTALLED WITH 1.50% pVC - SSMH-4 RIM 63.33 INV. 56.56 (SSCO-400) OUT 56.36 (SSMH-3) (NOT INSTALLED WITH THIS PHASE) (179•S2 LF) 11•48%� g�� pVC- SSMH-3 RIM b2-9G INV. 54-9b (SSMH-4) INV. 54:8b (SSCO-300) OUT 54:7U (SSMH-2) (62.45) (54.66) _ (54.66) (54.64) 155%� (133.83 LF) @ SSMH-2 RIM b8�J3 INV. 52$6(SSMH-3) INV. 57:38(SSCO-200) OUT 5d!86 (SSMH-1) (62.86) (51.97) (57.05) SSMH-1 (51.85) RIM 5�-27 (56.11) INV. �l•8-8b(SSMH-5) (49.80) INV. �.9!db(SSMH-2) (49.77) OUT A•3-7U (EX-SSMHS) (49.71)