HomeMy WebLinkAboutSW6091006_Stormwater Management Plan_201002160 m STORMWATER MANAGEMENT PLAN PREPARED FOR: FORT BRAGG INDOOR RIFLE RANGE DATE: 10-05-09 DENR-FRO EARTH TECH, INC 701 CORPORATE CENTER DR., SUITE 475 RALEIGH, NC 27607 919-854-6200 PREPARED BY: BRYAN M. DICK, PE, PH CHECKED BY: MARK KAMPRATH, PE L FEB 16 2010 DWQ �\\u 111111/// �� CARO4 / tc)ls SEA r • = 035724 — F,yGIN Ede F �. RANI M1`��G���\ PROJECT DESCRIPTION THIS DOCUMENT IS TO SERVE AS A STORMWATER MANAGEMENT PLAN FOR THE FORT BRAGG - INDOOR GUN RANGE PROJECT. THE PROJECT CONSISTS OF THE ADDITION OF A SINGLE BUILDING WITH GRAVEL PARKING LOT AND ASSOCIATED SIDEWALKS TO THE UNDEVELOPED SITE. THE COMPLETED PROJECT WILL PROVIDE FOR EXPANSION OF BASE FACILITIES TO SUPPORT THE MISSION. CONTACT INFORMATION EARTH TECHI AECOM, INC. ATTN: BRYAN M. DICK, PH 701 CORPORATE CENTER DR., SUITE 475 RALEIGH, NC 27607 TELEPHONE: 919-854-6252 FAX: 919-854-6259 IDENTIFY PROJECT INVOLVEMENT THIS PROJECT IS A PART OF THE CAPE FEAR RIVER BASIN AND IS CURRENTLY NOT SUBJECT TO ANY BUFFER RULES. THE SITE IS APPROXIMATELY 2,500 FEET FROM THE PERSIMMON CREEK, THE NEAREST AFFECTED SURFACE WATER. THE PROPOSED PROJECT STORMWATER PLAN WILL MEET THE REQUIREMENTS OF RETAINING THE RUNOFF VOLUME THE 1.0 INCH RAINFALL EVENT PER THE REQUIREMENTS BY THE STATE AS REFERENCED FROM THE DWQ STORMWATER MANUAL, JULY 2007. ONE INFILTRATION BASINS IS USED TO TREAT THE DRAINAGE AREA AND IT IS SIZED TO MEET THE 5-6-09 UPDATE FROM DWQ REGARDING BYPASS AND LEVEL SPREADERS FOR INFILTRATION BASINS. THE BASIN EXCEEDS THE 2.5X REQUIRED TREATMENT VOLUME AND DRAWS DOWN IN LESS THAN THE MAXIMUM OF 5 DAYS SET BY DWQ. THE DRAWDOWN WAS BASED ON '/2 THE KSAT VALUE REPORTED IN THE SEALED SOILS REPORT. IN SUMMARY, OPTION 3 OF THE DWQ UPDATE ON 5-6-09 REGARDING INFILTRATION DEVICES WAS USED TO WAIVE THE REQUIREMENT FOR A BYPASS AND A LEVEL SPREADER DEVICE. HYDROCAD MODELS BASES ON TR-55 METHODS WERE USED TO VALIDATE THE COMPLETE CAPTURE OF THE RUNOFF OF THE I" RAIN EVENT. STORMWATER DESIGN PARAMETERS THE INFILTRATION BASINS ARE BASED ON THE FOLLOWING PARAMETERS OR OBJECTIVES: • PROVIDE 85% TSS REMOVAL • PROTECT THE VALUE OF THE RECEIVING WATER RESOURCE • 1.0" RAINFALL FOR BASIN STORAGE SIZING • OVERFLOW DEVICE TO ACCOMMODATE STORMS IN EXCESS OF THE 10 YEAR STORM • RATIO OF IMPERVIOUS SURFACE TO THE TOTAL AREA OF THE DRAINAGE AREA • EXCEED A MINIMUM OF 2.0' CLEARANCE FROM THE SEASONAL HIGH WATER TABLE • VOLUME IS SIZED AT GREATER THAN 2.5 THE MINIMUM REQUIRED VOLUME • DESIGN KSAT VALUE WAS BASED ON �/z THE VALUE GIVEN AT THE LOCATION OF THE BASIN IN THE SOILS REPORT DISCUSSION OF TREATMENT MEASURES THE PROPOSED TREATMENT IS TO USE A SINGLE INFILTRATION BASIN TO CAPTURE AND TREAT THE RUNOFF FROM THE SITE FOR 10 YEAR STORM OR LESS. THE SANDY SOILS OF THE SITE ARE SUITED TO INSTALLATION OF AN INFILTRATION BASIN AND WILL MIMIC THE INFILTRATION OF RAINFALL FROM THE SITE THAT WOULD OCCUR PRIOR TO THE PROPOSED PROJECT. THE BASIN MAINTAINS A CLEARANCE OF 4.8' FROM THE SEASONAL HIGH WATER TABLE AT THE NEAREST SAMPLE LOCATION. CONCLUSION THIS STORMWATER MANAGEMENT PLAN REPRESENTS AN ENVIRONMENTALLY SENSITIVE AND EFFECTIVE PLAN FOR UTILIZING THE PROPOSED STORMWATER TREATMENTS TO ACCOMMODATE THE INCREASED RUNOFF OF THE PROPOSED SITE DEVELOPMENT. EARTH TECH I AECOM Vicinity Map Gunnery Range Ft. Bragg Cumberland County, North Carolina rill 0 0.5 1 2 Miles 11 1 1 1 1 1 1 1 Legend —Streets EARTH TECH AECOM NCDWQ Classification Map —Building Footprints Gunnery Range —Streams Ft. Bragg 20 foot Contour Cumberland County, North Carolina 10 Foot Contour 0 500 1,OOO 2,000 Feet 1 inch = 1,000 feet 112454 Bragg Gun Range - Infiltration Basin 1 Drainge Area (Sf) 70825 Imp Area (sf) 39853 (A) Drainage Area (Ac) 1.626 0A)Imp Fraction 0.56 (RD)Rainfall Depth Per State SWP(in) 1 Step 1: Determine Runoff Volume SN V'n✓— Simple Method IVJ a' RV = .05 + .9(1,) = Rv (post)=.05+.9'.67 Rv (pre)=.05+.9'0 b V=3630xRDxR xA Post V=3630'1.0'0.67'.6273 Designed By: BMD Date: 9/28/2009 0.56 0.05 V (Post) = 3284 of Min. Treatment Vol = 3284 cf Treatment Vol in Ac-in 0.90 ac-in Step 2: Determine Surface Area- Min. Required Volume for 2.5X to Not Bypass or Filter 8210 cf (K) Infiltration Rate (ir/hr) 12.2fi 'Half the K value from the Soils Report I I ) intended Days to Infiltrate (days) 2 a. A — V = A=3799/(2'(5.66'2)) IMin SA of Basin = 67.0 sf 2*(K *T) Slop 3. Determine Dimensions Volume Storage Elevation 304.30 Elevation 301.40 Overflow Weir Elevation Jet Elevation 301.40 TOD of Berth Elevation Storage Depth 2.90 Surface Area Required (Avg of Top and Bottom SA) Top Width ® Storage Elev 37.4 Top Length @ Storage Elev Bottom Width 20 Bottom Length 4. Calculation of Volumetric Flow Rate of Irditration and Drawdown 0 from infiltration: '0 is actually the Darcian Flow Rate of Q: SurfaceArea=3184sf (K)=2.42 in/ 2.42in I ff I hr 184sf �—=O.IScfs hr 12in 3600s 6aampleCalculatial: Q=0.I8cfs V=3184cf V =T 3184fr' Is Ihr=2.Ihrs=.049days Q 1 0. 18ff1 3600s 2.90 2 Target Area 0 sf 113.4 Surface Area Storage = 4241 sf 96.0 Surface Area Bottom = 1920 sf 1Avq Surface Area = 3081 sf Volume of Basin (Depih'SA) = 8934 cf Ezceed Required Volume by 2.72 X Area (sf) (K) in/hr 0 (infiltration) = 0.54 cfs 1920 12.255 Drawdown Time for Design Vol Volume c i Hours Da 8934 0.54 4.6 0.19 Drainage Area Impervious Post Pervious Pre A Rational Method Peak Flow Calculation for Supplement 1.53 Ac C 43278 sf 0.98 23380 sf 0.15 Composite C 0.69 Qp - post 0.95 Qp - Pre 0.21