Loading...
HomeMy WebLinkAboutSW6080804_Grading Plan_20100608I I I I I PqR/ge�gP p��� G/0 / I I I I 1 NOTES: 1. THIS MAP IS NOT A CERTIFIED SURVEY. BOUNDARY AND TOPOGRAPHIC INFORMATION PROVIDED BY KESTLER SURVEYING, INC. \ 2. THE UTILITIES SHOWN ARE FOR THE CONTRACTOR'S CONVENIENCE ONLY. \ THERE MAY BE OTHER UTILITIES NOT SHOWN ON THIS PLAN; THE ENGINEER ASSUMES NO RESPONSIBILITY FOR THE LOCATIONS SHOWN. THE CONTRACTOR IS RESPONSIBLE FOR LOCATING ALL EXISTING UTILITIES PRIOR TO I COMMENCEMENT OF CONSTRUCTION. CONFLICTS BETWEEN EXISTING UTILITIES AND I PROPOSED EXCAVATION SHALL BE REPORTED TO THE ENGINEER IMMEDIATELY. 3. PROVIDE MINIMUM OF 48 HOUR NOTICE TO OWNER OR REPRESENTATIVE PRIOR TO INTERRUPTION OF ANY EXISTING UTILITY, IF BEING UTILIZED. I I ff i ' \\ IC-4 1 1/2" I! I INV=494.31 I y rn j ^1 5/8" 1 1 INV=494.50 C=_I/ , I ( I 1 1/2-�-j /�p i , I I I-- LONZELL KELLY TAX #694240801071 DEED BK 194, PG 097 z H RRI AVE SS MH `ItpVp45105 WV IN94918.86 INV OUT=491.72 EXISTING CONCRETE o Q i I y\ I j PROP. DI GRA RIM=497.5 \ ---_ Q J -� I.E.(IN)=495.i6 f p \ LOCATION MAP _ 5 ir a E .LE (OUT)=495.31� NOT TO SCALE C9 W I a1 J I PROP DI GRATE tl N 0 m I EX. IM=497.92 r r;; \ W. EDINBOROU� / EDGE OF I 3 WV EXII.E(0 T)=4H AVENUE 95.92 50' Y �> E PUBLIC R/W (APPAREN Q i DRAINAGE NOTES: 1. REVERSE CURB AND GUTTER TO BE USED IN AREAS NOT CHANNELING STORM WATER RUNOFF. 2. THE PROPOSED CONTOURS WITHIN PAVED AREAS ARE GRAPHICAL REPRESENTATIONS ONLY. THE CONTRACTOR IS RESPONSIBLE FOR GRADING UNIFORMLY BETWEEN SPOT ELEVATIONS. 3. CONTRACTOR TO GRADE ALL AREAS WITHIN PROJECT TO DRAIN STORM WATER. CARE SHALL BE TAKEN TO ENSURE THAT ALL AREAS WITHIN PARKING LOTS AND LANDSCAPED ISLANDS SHALL NOT HOLD WATER UPON PROJECT COMPLETION. 4. MIN. SLOPE ON ALL ASPHALT TO BE 1.5X 5. MIN. SLOPE ON CURB AND GUTTER CARRYING STORM WATER TO BE 0.51 6. MIN. SLOPE ON REVERSE CURB AND GUTTER TO BE 0.5X 7. HOPE IS AN ACCEPTABLE SOLUTION FOR CLASS III RCP. 4. THE CONTRACTOR IS RESPONSIBLE FOR REPAIR AND/OR REPLACEMENT OF ANY UTILITIES DAMAGED DURING CONSTRUCTION. THE CONTRACTOR SHALL BE SOLELY RESPONSIBLE FOR LOCATION & PROTECTION OF EXISTING ABOVE AND BELOW GROUND UTILITIES AND STRUCTURES. ANY AND ALL MAINS OR INDIVIDUAL SERVICES PRESENTLY IN SERVICE WHICH ARE DAMAGED DURING CONSTRUCTION SHALL BE REPAIRED IMMEDIATELY AT NO ADDITIONAL EXPENSE TO THE UTILITY OWNER. ANY AND ALL MAINS OR INDIVIDUAL SERVICES PRESENTLY NOT IN SERVICE AND WHICH ARE TO BE REPLACED DURING THE COURSE OF CONSTRUCTION MAY BE REMOVED AND LEGALLY DISPOSED OF IF DAMAGED DURING CONSTRUCTION. 5. THE CONTRACTOR SHALL USE EXTREME CARE WHEN WORKING NEAR ALL UNDERGROUND AND OVERHEAD UTILITIES. 6. HANDICAP SIGNAGE TO BE INSTALLED IN ACCORDANCE WITH A.D.A STANDARDS AT H/C PARKING SPACES SHOWN. 7. ALL DIMENSIONS ARE TO BACK OF CURB UNLESS OTHERWISE NOTED. 8. THE CONTRACTOR IS RESPONSIBLE FOR ENSURING THAT ALL NECESSARY PERMITS AND APPROVALS HAVE BEEN OBTAINED PRIOR TO CONSTRUCTION. THESE PERMITS AND APPROVALS MAY INCLUDE BUT ARE NOT LIMITED TO GRADING, DEMOLITION, ZONING, BUILDING, DRIVEWAY, DETENTION, SUBDIVISION, SPECIAL USE, SEWER AND WATER. JAMES N. DRAKOS TAX #694240801023 DEED BK 206, PG 307 h � Iv ry I O rn k F--1'-4 1/2' III1.�1'-4 1/2"- •-1'-7 5/8'-►{I--1'-7 5/8-- PLAN OF GRATING CAST IRON JOSEPHINE FLOWERS TAX #694240801067 DEED BK 222, PG F '. RIP RAP X 81 X 12"D MARILYN E. SMITH TAX #694240801062 DEED BK 595, PG 285 CHARLES E. GREEN TAX #694240801061 DEED BK 47Z PG 822 GRAPHIC SCALE 2'-3 1 /4"----1 f.-2" SECTION H-H E a I Y F -3- _6. RAQ 2 1/8" F-- 2'-1 3/4 = 2'-6 FRAME, GRATE, FOR DROP INLET SECTION F-F NCDOT DWG #840.16 2'-6" non I ZI�T ■i■ Sun ITS ■_un i � Y-� WITH COPING REMOVED DIMENSIONS AND QUANTITIES DIMENSIONS OF BOX & PIP CONC. I IN BASE TOTAL BRICK MASONRY DEDUCTIONS FOR ONE PIPE PIPE SPAN WIDTH HEIGHT PER FT. HEIGHT BRICK COPING MIN. H B A I 8 H MIN. C.U. YDS C.M. R.C. 12" 3'-0 2'-0" 2'-8 0.267 0.313 0.037 0.871 0.020 0.032 15" 3 -0 6976 0.031 0.047 18 3 -5 1.106 0.044 0.065 24 2'-0" 4'-0" 0.267 0.313 0.037 1.289 0.078 0.113 _IENERAL NOTES: 1. ALL DROP INLETS OVER 3'-6" IN DEPTH TO BE PROVIDED WITH STEPS 1'-2" ON CENTERS. STEPS SHALL BE IN ACCORDANCE WITH STD. 20.12 2. ALL CONCRETE TO BE 3600 P.S.I. COMPRESSIVE STRENGTH. 3. MORTAR JOINTS SHOULD BE BETWEEN 3/8" AND 5/8" THICK. 4. BRICK MASONRY DROP INLET NOT TO BE USED IN LOCATIONS SUBJECT TO TRAFFIC. 5. JUMBO BRICK WILL BE PERMITTED. CONCRETE BRICK OR 4" SOLID CONCRETE BLOCKS MAY BE USED IN LIEU OF HARD COMMON CLAY BRICK. 6. FOR 8"-0" IN HEIGHT OR LESS USE 8" WALL OVER 8"-0" IN HEIGHT USE 12" WALL TO 6'-0" FROM TOP OF WALL AND 8" WALL FOR THE REMAINING 6'-0". QUANTITIES TO BE ADJUSTED ACCORDINGLY. 7. FOR FRAME AND GRATE DETAIL SEE STD. NO. 20.14. B. ALL PIPE IN STORM DRAIN STRUCTURE TO BE STRUCK EVEN WITH THE INSIDE WALL, GROUTED AND BRUSHED SMOOTH. 9. ALL SLABS SHALL BE FORMED. Approved Sto. mwatar Permit Documents BRICK DROP INLET Construction ir accordance with these documents is required by the stormwater permit. North Carolina NCDOT DWG #840.15 rules require trial the stormwater system designer Inspect durin construction 'ertily of th th - tLLV EXISTING CONTOUR '-"'"ELEV-�� PROPOSED CONTOUR ELEV PROPOSED SPOT ELEVATION (ON ASPHALT) PROPOSED STORM DRAIN EXISTING STORM DRAIN - - -RD PROPOSED ROOF DRAIN SS EXISTING SANITARY SEWER LINE W EXISTING WATER LINE --G EXISTING GAS LINE g co ormi,y w; e plans and specs; and certify Compliance with the stormwater rules. (15A NCAC 2H 1005 (j ); Parmlt#p 15W6OtV0&m'y___Date o s ag by_ �e_'�-p _ _ NC Divtslan of Wal.r 0 ality Sheet # 3. O_Revision Date_ ? 9 0 1 INCH = 20 FEET