Loading...
HomeMy WebLinkAboutWM0501568_Application_20230718NORTH CAROLINA DEPARTMENT OF ENVIRONMENTAL QUALITY - DIVISION OF WATER RESOURCES APPLICATION FOR PERMIT TO CONSTRUCT A MONITORING OR RECOVERY WELL SYSTEM PLEASE TYPE OR PRINT CLEARLY 1. 2. 3. 4. 5. 6. 7. 8. 9. 10 In accordance with the provisions of Article 7, Chapter 87, General Statutes of North Carolina and regulations pursuant thereto, application is hereby made for a permit to construct monitoring or recovery wells. Date: July 18, 2023 County: Wake FOR OFFICE USE ONLY PERMIT NO. ISSUED DATE What type of well are you applying for? (monitoring or recovery): Monitoring Wells Applicant: Six Forks-FCA, LLC - Petitioner for DSCA Site ID DC920020 (Sherrill's Cleaners) Telephone: 919-707-8367 Applicant's Mailing Address: NCDEQ DWM, DSCA Program, Jay King 1949 Mail Service Center, Raleigh, NC 27699 Applicant's Email Address (if available): a ay.kinq(cDncdenr.gov Contact Person (if different than Applicant): Nick Shore (AECOM) Telephone: 919-461-1485 Contact Person's Mailing Address: 5438 Wade Park Boulevard, Suite 200, Raleigh, NC 27607 Contact Person's Email Address (if available): nick.shore(@aecom.com Property Owner (if different than Applicant): City of Raleigh (Lenny Wallace) Telephone: 919-996-2493 Property Owner's Mailing Address: PO Box 590, Raleigh, NC 27602 Property Owner's Email Address (if available): linwood.wallace(a)raleighnc.gov Property Physical Address (Including PIN Number) City Right of Way at 7512 and 7601 Stuart Drive City Raleigh County Wake Zip Code 27615 Reason for Well(s): environmental assessment (ex: non -discharge permit requirements, suspected contamination, assessment, groundwater contamination, remediation, etc.) Type of facility or site for which the well(s) is(are) needed: (ex: non -discharge facility, waste disposal site, landfill, UST, etc.) Are there any current water quality permits or incidents associated with this facility or site? If so, list permit and/or incident no(s). none 11. Type of contaminants being monitored or recovered: chlorinated solvents and metals (ex: organics, nutrients, heavy metals, etc.) 12. Are there any existing wells associated with the proposed well(s)? If yes, how many? Yes, 14 Existing Monitoring or Recovery Well Construction Permit No(s).: Unknown, MWs installed by previous consultant 13. Distance from proposed well(s) to nearest known waste or pollution source (in feet): 2,040 and 2,625 feet 14. Are there any water supply wells located less than 500 feet from the proposed well(s)? No If yes, give distance(s): 15. Well Contractor: Geologic Exploration Certification No.: 2580A Well Contractor Address: 176 Commerce Blvd., Statesville, NC 28626 PROPOSED WELL CONSTRUCTION INFORMATION As required by 15A NCAC 02C .0105(f)(7), attach a well construction diagram of each well showing the following: a. Borehole and well diameter e. Type of casing material and thickness b. Estimated well depth f. Grout horizons C. Screen intervals g. Well head completion details d. Sand/gravel pack intervals Continued on Reverse PROPOSED WELL CONSTRUCTION INFORMATION (Continued) 2. Number of wells to be constructed in unconsolidated 5. How will the well(s) be secured? Locking well cap material: 2 3. Number of wells to be constructed in bedrock: 0 6. Estimated beginning construction date: 8-9-23 4. Total Number of wells to be constructed: 2 7. Estimated construction completion date: 8-9-23 (add answers from 2 and 3) ADDITIONAL INFORMATION 1. As required by 15A NCAC 02C .0105(f)(5), attach a scaled map of the site showing the locations of the following: a. All property boundaries, at least one of which is referenced to a minimum of two landmarks such as identified roads, intersections, streams, or lakes within 500 feet of the proposed well or well system. b. All existing wells, identified by type of use, within 500 feet of the proposed well or well system. C. The proposed well or well system. d. Any test borings within 500 feet of proposed well or well system. e. All sources of known or potential groundwater contamination (such as septic tank systems, pesticide, chemical or fuel storage areas, animal feedlots as defined in G.S. 143-215.10B(5), landfills, or other waste disposal areas) within 500 feet of the proposed well or well system. SIGNATURES The Applicant hereby agrees that the proposed well(s) will be constructed in accordance with approved specifications and conditions of this Well Construction Permit as regulated under the Well Construction Standards (Title 15A of the North Carolina Administrative Code, Subchapter 2C) and accepts full responsibility for compliance with these rules Env. Project Manager ig ature of Applicant or *Agent Title of Applicant or *Agent Nick Shore on behalf of DSCA Petitioner for DSCA Site ID 920020 * if signing as Agent, attach authorization agreement stating Printed name of Applicant or *Agent that you have the authority to act as the Agent. If the property is owned by someone other than the applicant, the property owner hereby consents to allow the applicant to construct wells as outlined in this Well Construction Permit application and that it shall be the responsibility of the applicant to ensure that the well(s) conform to the Well Construction Standards (Title 15A of the North Carolina Administrative Code, Subchapter 2C). See Attached Access Agreement Signature of Property Owner (if different than Applicant) Printed name of Property Owner (if different than Applicant) DIRECTIONS Please send the completed application to the appropriate Division of Water Resources' Regional Office: Asheville Regional Office 2090 U.S. Highway 70 Swannanoa, NC 28778 Phone: (828) 296-4500 Fax: (828) 299-7043 Fayetteville Regional Office 225 Green Street, Suite 714 Fayetteville, NC 28301-5094 Phone: (910) 433-3300 Fax: (910) 486-0707 Mooresville Regional Office 610 East Gen Mooresville, F Phone: (704'; Fax: (704) 6( Raleigh Regional Office 3800 Barrett Drive Raleigh, NC 27609 Phone: (919) 791-4200 Fax: (919) 571-4718 Washington Regional Office 943 Washington Square Mall Washington, NC 27889 Phone: (252) 946-6481 Fax: (252) 975-3716 Wilmington Regional Office 127 Cardinal Drive Extension Wilmington, NC 28405 Phone: (910) 796-7215 Fax: (910) 350-2004 Winston-Salem Regional Office 450 W. Hanes Mill Road Suite 300 Winston-Salem, NC 27105 Phone: (336) 776-9800 -ax: (336) 776-9797 GW-22MR Rev. 3-1-2016 1L-A LEGEND 1 MW-4 (2/24/2010) 00 ® Monitoring Well Location 1 BDL - Bch Abandoned Monitoring Well Location IHOP to Peachtree Market Eye Care Shopping Center Restaurant Center Pore/Surface Water Sample Location MW-1 (11/30/2016) N�JEXPO�URE UNIT #1 Sher ' ' - BB T MW-3 (10/29/2014) 0G Exposure Unit Bound 3 Chloroform - 12.8 ug/1 Ba p Boundary eaning PCE - 1.1 ug/1 :VIW-11 (2/22/2010) 00 � � � / lhp Chloroform - 0.84 J ug/1 - Potentiometric Surface Contour (ft/msl) � Inferred Groundwater Flow Direction BDL I i - I MW-7S (2/22/20101 �� Surficial Drainage Feature MW-2 Naphthalene /2 5 J /l Chloroform- 3.6 J ug/l Unnamed Tributary to Mine Creek Naphthalene - 0.5 J ug/l PCE - 470 ug/1 EXPOSURE UNIT #2 � lebration at._ � Naphthalene - 0.84 J ug/1 � Approximate Location of Stormwater Pipe Six atiou MW-7D (2/22/2010) 00 TCE - 0.5 J ug/1 f Chloroform- 3.4 J ug/l ■ Approximate Location of Dry -Cleaning Chloroform - 0.39 J ug/1 Sh ping C'cntcr Grand g Machine Asia Buffet )�' BDL Below Laboratory Detection Limits MW-5S (10/29/2014) }{ 4 J Estimate Value DRY / ' ( - _ _ MW-8S (2/24/2010) NM-5D (10/29/2014) N BDL ug/1 micrograms per liter PCE - 4.3 u 1 # McDonald's MW-8D (2/24/2010) N -1 Restaurant J {/ i Chloroform- 0.66 J ug/1 l J Area of PCE 2L Standard Exceedance MTBE - 1.1 ug/1 ' Chloroform- 3.3 J ug/l _ Naphthalene - 0.77 J ug/1 _ Red highlighted text indicates samples exhibiting greatest MW-10 (1/11/2018) 00 VI risk in each exposure unit. BDL i 3� �' _ � PCE - Tetrachloroethene - I MTBE - Methyl tert-butyl ether MW-6 (7/3/2013) 00 L 3� Groundwater analytical results do not exceed f' PCE - 5.3 ug/l / 00 calculated vapor intrusion risk for residential Chloroform- 1.2 J ug/l MW-9S (1/11/2018) 00 or non-residential exposure - DSCA Indoor Naphthalene - 0.49 J ug/l PCE - 8.68 ug/l Air Risk Calculator, Version 8, March 2021. r Y% II MW-9D (1/11/2018) 00 Groundwater analytical results exceed r s,. PCE - 8.06 ug/l N calculated vapor intrusion risk for residential and non-residential exposure - DSCA Indoor * MW-12 (1/11/2018) 00 / Air Risk Calculator, Version 8, March 2021. BDL Note: Two surface water samples are labeled SW-106. Location SW-106* was sampled in 2021 MW-13 (10/29/2014) 00 - MW-14 (11/30/2016) 00 1 PCE - 0.49 ug/1 f. { PCE - 8.1 ug/1 f _ Chloroform - 0.81 J ug/l ; ;r / MTBE - 0.63 J ug/1 r PW-101 (12/17/2018) SW-106 (3/13/2019) BDL r • x BDL , PW-106 (3/13/2019) N i SW-101 (12/17/2018) "� BDL BDL 1 PW-106 (8/24/2021) BDL SW-106* (8/24/2021) MW-15S (11/30/2016) 00 BDL PCE - 9.53 ug/1 MW-15D (10/29/2014, 00 ' PW'-102 (12/17/2018) PCE - 12 ug/l Toluene - 4.07 ug/1 Acetone- 1,800ug/l Chloroform- 0.92 J ug/1 PW-103 (12/17/2018) 4 PCE - 1.60 ug/l PW-107 (8/24/20211 SW-103 (12/17/2018) ; C Acetone - 15.1 J ug/l BDL p-isopropyltoluene - 151 ug/l f 2-Butanone - 5.94 ug/l Y' Toluene - 7.67 ug/1 _ PW-104 (3/13/2019) x � SW-108 (8/24/2021) f PCE - 1.06 ug/1 BDI. SW-104 (3/14/2019) BDL SW-107 (8/24/2021) BDL { PW-108 (8/24/20211 Pam'-105 (31 3/20191 Carbon Disulfide - 0.37E J ug/l r+� BDL w � ASW-105 (3/14/2019) - .r' �# PW-109 (8/24/20211 BDL * BDL PW-110 (8/24/2021) - t ! 0 Carbon Disulfide - 0.364 Jug/l . p-isopropyltoluene - 7.0 ug/l - SW-109 (8/24/2021) a BDL _ i f� 0 320 APPROX. SCALE, ft. J �Ad4# r DRAWN BY Groundwater Quality Summary Map �l y SDH - 03/22/2019 AECOM TECHNICAL SERVICES OF D_EP"=COM NORTH CAROLINA, INC. Sherrill's Dry Cleaners CHECKED EY: 5925 CARNEGIE BLVD. SUITE 370 FNs - 03/22/2019 , CHARLOTTE, NC 28209 7463 Six Forks Road TEL (704) 522-0330 Raleigh- NC; ilppl.E OR'C Jyo C 01 ­7411 to'?r, DR l N Pre il NOU EAU 8i A ONE ____360 OPOAK '440" D R L L p �CWE OR _<L� FARRI C, Q 440 400-- P* 0 IN R�qional C , It Libra —C)R ry io, 0 NORTHWAY Site Locatio 0 SAWM R T 4/1� 1_!V PARK DR C C%.9 LOGfIAND DR 4EW-Tolv—RD OZ I`F A D DR 1*E_EK__) 4 M ECT —360 -11_9�4f� M C C C NIK01,, T ELN 7- _kT__ _j 7 N USGS The National Map: National Boundaries Dataset, National Elevation Dataset, Geographic Names Information System, National Hydrography 1,000 500 0 1,000 Dataset, National Land Cover Database,NationalStructures Dataset, and National Transportation Dataset; U.S. Census Bureau - TiGER/Line; HERE Scale in Feet Road Data Site Location Map AECOM Q AECOM5438 Wade Park Boulevard, Suite 200 Sherrill's Dry Cleaners Raleigh, NC 27607 7463 Six Forks Road Phone: (919) 461 -1100 Fax: (919) 461-1415 Raleigh, NC www.aecom.com DSCA Site ID: DC920020 SHEET: I I I Figure 2 Client: Sherrill's Cleaners (DC920020) WELL ID: Proposed Type II Well _ Project Number: 60695852 A:COM Site Location: 7512 and 7601 Stuart Drive, Raleigh, NC Date Installed: 9-Aug-23 Well Location: Coords: Inspector: Method: 4.25"ID HSA Contractor: Geologic Exploration PROPOSED MONITORING WELL CONSTRUCTION DETAIL Depth from G.S. (feet) Elevation (feet) Datum 8-inch diameter flush -mount steel vault to be set in 2'x2'x0.5' concrete pad Top of Riser Pipe 0.0 Ground Surface (G.S.) 0.0 Benton Describe Measuring Point: Note: Depths are Riser P ipe: Length Diameter (ID) Type of Material Thickness Grout: Type Thickness Top of Bentonite 60 neat cement 55' ite Seal Thickness 3' Top of Sand Top of Screen Screen: Len gth 10 Dia meter (ID) 2" Slot Size 10 slot Type of Material PVC Thickness Sch 40 Type/Size of Sand #2 Sand Pack Thickness 12 Bottom of Screen Bottom of Tail Pipe: Bottom of Borehole Borehole Diameter 4.25" ID HSA Signature and will be adjusted based on field conditions. Not to scale. 55 58 60 70 70 70 Date