HomeMy WebLinkAboutWI0500013_Compliance Evaluation Inspection_20230919DocuSign Envelope ID: 22545EBB-EE51-4116-8CDC-BDD4BA79C16B ROY COOPER Governor ELIZABETH S. BISER Secretary RICHARD E. ROGERS, JR. NORTH CAROLINA Director Environmental Quality September 19, 2023 Ms. Diana McElroy 1111 Monterey Valley Drive Chapel Hill, NC 27516 Sent Via Email Subject: Geothermal Well Renewal Permit # W10500013 Summary of Inspection and Sampling on August 22, 2023 Ms. McElroy: In support of your request for renewal of the above -referenced geothermal well permit, Michael Hall from the Division of Water Resources Performed an inspection and collected samples from the well effluent and geothermal system discharge on August 22, 2023. The permittee, Diana McElroy was present during the inspection, and identified the location of the well, and geothermal system discharge (see attached site plan). The well is used for both potable water, and for two geothermal units serving the residence. During the inspection, one of the geothermal units, serving the downstairs, was not working and Ms. McElroy indicated that it was due to be repaired. The other unit, serving the upstairs of the residence, was running during the inspection, actively drawing water from the well, and discharging to surface water. The well vault was in good condition and was secure at the time of the inspection (see attached photographic log). The inside of the vault was stuffed with fiberglass insulation, which was falling apart, and contained an ant nest. The wellhead appeared to be secure. The pipes and wires leading to the well were sound, although corroded. No well plate was observed. The inspector recommended the use of foam insulation, as opposed to fiberglass to avoid the mess and moisture retention within the well vault. Based on this recommendation, the permittee asked the inspector to leave the insulation out of the well vault. Two discharge pipes lead from the well. According to the permittee one is for the water supply, and one is for the geothermal unit; although the pipes were not labeled, and which pipe led to which service could not be determined. The discharge consisted of a 4-inch PVC pipe with a small pool around it. Flow was observed into the pool at the time of the inspection. The water was clear, and was running downhill to a stream to the North of the residence. The inspector recommended to the permittee that the discharge area be kept clear of vegetation, and that the pool be removed, to limit the potential for water to back up into the pipe. Water samples were collected from the well head and the discharge. The well head was sampled using a hose (provided by the permittee) attached to one of the sampling ports on the discharge pipes described above. The well was purged for at least 20 minutes prior to sampling. The discharge from the geothermal unit was sampled by dipping water from the pool surrounding the discharge pipe with a clean sample bottle and decanting into sample bottles for the laboratory. Samples were delivered to the Division of Water Resources Laboratory on August 22, 2023. D E Q ,fJ North Carolina Department of Environmental Quality I Division of Water Resources Raleigh Regional Office 1 3800 Barrett Drive I Raleigh, North Carolina 27609 NORTHCAROUNA 919.791.4200 Department ofEnvlronmantal Duali� DocuSign Envelope ID: 22545EBB-EE51-4116-8CDC-BDD4BA79C16B Water quality measurements were collected prior to sampling from both the well effluent and discharge. These measurements were within the expected range for natural groundwater: Sample Temperature (DC) pH (s.u.) Dissolved Oxygen (mg/1) Specific Conductivity Salinity (ppt) (umhos/cm) W1 Effluent 16.48 6.82 5.59 194.37 0.09 W1 Discharge 19.24 7.49 6.27 182.20 0.09 The measurements are relatively similar between the well effluent and the system discharge, with the exception that the temperature, pH and dissolved oxygen was slightly higher. Laboratory analytical results were below the North Carolina Groundwater Standards (NCAC 15A.02L), with the exception of total and fecal coliform. Both total and fecal coliform should not be detected in groundwater, and the detection of these parameters is likely the result of contamination from the use of the hose, and not representative of an impact to the well. The detection of total and fecal coliform in the discharge in not unexpected, given that the sample, by necessity, was drawn from a vegetated, small pond surrounding the discharge pipe, and the water was in contact with soil and vegetation. Neither the field measurements or the laboratory results suggest a concern regarding groundwater quality, and the continued use of the well for both a potable supply, and geothermal air conditioning is appropriate. We appreciate your assistance during the inspection, and if you have any questions regarding this report or its conclusions, please contact Michael Hall at (919) 791-4237 or via email at.michael.halI@deg.nc.gov. Sincerely, ocuSigned by: E�D a -e, i�l.atn ALL 2916E6AB32144F... Vanessa E. Manuel, Assistant Regional Supervisor Water Quality Regional Operations Section Raleigh Regional Office Division of Water Resources, NCDEQ Enclosure Site Plan Photographic Log Laboratory Analytical Reports cc: Laserfiche NORTH CAROLINAD_E Q> Depanmem of Envlmnmenml Oual� North Carolina Department of Environmental Quality I Division of Water Resources Raleigh Regional Office 1 3800 Barrett Drive I Raleigh, North Carolina 27609 919.791.4200 DocuSign Envelope ID: 22545EBB-EE51-4116-8CDC-BDD4BA79Cl6B Geothermal Well Inspection Permit Number1 111 Monterey1111 •County ��rr f`, �. �', i ram./ F...e % ♦.�y' ra,^ • ,{• �(. r "jj" 3 f� ti.<� t 1 l F 4. its it ,.''{ • i`�{�jy'• �Y -' 0 200�1 t 400 Feet Legend Parcel Boundaries Approxi.mate'Gediber 1 o-.77,11D_E Q Map provided by NCDEQ Division of Water Resources. Locations are approximate and are provided for reference only. DocuSign Envelope ID: 22545EBB-EE51-4116-8CDC-BDD4BA79C16B W10500013 — 1111 Monterey Valley Drive Geothermal Well Permit Renewal Chapel Hil: Photograph 1 Photograph 2 View to South of well vault. View into well vault showing insulation debris and ants, as well as pump lines for e• and water supply. � r � � a w �i+�i, ,i �c�v� ��`r -�, aY, x� �'iy �t ti0 � " �"�►�� -.< .''''� � > �',� X'SM Ft _ � EA,y� 1: R��rt �ihni - �"�,�„s� yam I � �� w� 1 '��` � ♦; _ .. _.,.. '- � � � 61" , �i Y� _ _.t�th`J ;,Y .L�� '�N ��. � /• �n r ��._'4r� � � � % � i�1)� WPM ML DocuSign Envelope ID: 22545EBB-EE51-4116-8CDC-BDD4BA79C16B W10500013-1111Monterey Valley Drive Geothermal Well Permit Renewal"'^ Chapel Hill/Orange s 1.����,. Photograph 3 Photograph 4 View South of vegetation around discharge for geothermal unit. View of small pool around discharge pipe for geothermal unit. d � ',• I �a.'�, -�� �� t w � spy r `! r ,'� Yam' ry ^ S( � ,?4.. � '� �,. � J.: •,pig ' s �i'a r � � _ _fir �"�°�o. ` �. r"' '�a �-�& °y '� !f C � � ' � ` . y ". ,� Y<''.'9'A����✓ , '� r� a terra � � s�f � _10 � ,cry , ✓ s - � A 1w - c �' �i �,�. � `� r . �''� +�►'� `gip'' � �� ;t,A .� a DocuSign Envelope ID: 22545EBB-EE51-4116-8CDC-BDD4BA79C16B AD13413 North Carolina Division of Water Resources Water Sciences Section Laboratory Results Loc. Descr.: 1111 MONTEREY VALLEY DRIVE County: Orange Collector: M HALL VisitlD Region: Raleigh Report To RRO Location ID: W1 EFFLUENT River Basin CPF Collect Date: 08/22/2023 Priority COMPLIANCE Emergency Collect Time: 11_23 Sample Matrix: GROUNDWATER COC Yes/No Sample Depth Loc. Type: Water Supply Final Report If this report is labeled preliminary report, the results have not been validated. Do not use for Regulatory purposes. Result/ Method Analysis CAS # AnalVte Name PQL Qualifier Units Reference Date Validated by LAB Sample temperature at receipt by lab 0.4 °C 8/22/23 MSWIFT Conform, MF Fecal in liquid 1 MIC 1 B2 CFU/100ml SM 9222 D-1997 8/22/23 JJURGEVICH Conform, MF Total in liquid 1 48 CFU/100ml SM 9222 B-1997 8/22/23 JJURGEVICH E701177 NO2+NO3 as N in liquid 0.03 NUT 0.78 mg/L as N EPA 353.2 REV 2 8/30/23 ALWILLIAMS 24959-67-9 Bromide 0.4 WET 0.4 U mg/L EPA300.0 rev2.1 8/28/23 ALWILLIAMS 16887-00-6 Chloride 1.0 4.7 mg/L EPA300.0 rev2.1 8/28/23 ALWILLIAMS 16984-48-8 Fluoride 0.4 0.4 U mg/L EPA300.0 rev2.1 8/28/23 ALWILLIAMS 14808-79-8 Sulfate 2.0 3.1 mg/L EPA300.0 rev2.1 8/28/23 ALWILLIAMS Total Dissolved Solids in liquid 12.5 148 mg/L SM 2540 C-1997 8/29/23 ALWILLIAMS 7440-22-4 Ag by ICPMS 1.0 MET 1.0 U ug/L EPA200.8 Rev5.4 9/6/23 JJURGEVICH 7429-90-5 Al by ICP 50 50 U ug/L EPA200.7 Rev4.4 8/29/23 JJURGEVICH 7440-38-2 As by ICPMS 2.0 2.0 U ug/L EPA200.8 Rev5.4 9/6/23 JJURGEVICH 7440-70-2 Ca by ICP 0.10 21 mg/L EPA200.7 Rev4.4 8/29/23 JJURGEVICH 7440-43-9 Cd by ICPMS 0.50 0.50 U ug/L EPA200.8 Rev5.4 9/6/23 JJURGEVICH 7440-48-4 Cobalt by ICP 50 50 U ug/L EPA200.7 Rev4.4 8/29/23 JJURGEVICH 7440-47-3 Cr by ICPMS 5.0 5.0 U ug/L EPA200.8 Rev5.4 9/6/23 JJURGEVICH 7440-50-8 Cu by ICPMS 2.0 8.2 ug/L EPA200.8 Rev5.4 9/6/23 JJURGEVICH 7439-89-6 Fe by ICP 50 50 U ug/L EPA200.7 Rev4.4 8/29/23 JJURGEVICH 7440-09-7 K by ICP 0.10 0.83 mg/L EPA200.7 Rev4.4 8/29/23 JJURGEVICH 7439-95-4 Mg by ICP 0.10 7.1 mg/L EPA200.7 Rev4.4 8/29/23 JJURGEVICH 7439-96-5 Mn by ICP 10 10 U ug/L EPA200.7 Rev4.4 8/29/23 JJURGEVICH 7440-23-5 Na by ICP 0.10 10 mg/L EPA200.7 Rev4.4 8/29/23 JJURGEVICH 7440-02-0 Ni by ICPMS 2.0 2.0 U ug/L EPA200.8 Rev5.4 9/6/23 JJURGEVICH 7439-92-1 Pb by ICPMS 2.0 2.0 U ug/L EPA200.8 Rev5.4 9/6/23 JJURGEVICH 7782-49-2 Se by ICPMS 1.0 1.0 U ug/L EPA200.8 Rev5.4 9/6/23 JJURGEVICH 7440-66-6 Zn by ICPMS 10 10 U ug/L EPA200.8 Rev5.4 9/6/23 JJURGEVICH WSS Chemistry Laboratory>> 1623 Mail Service Center, Raleigh, NC 27699-1623 (919) 733-3908 "Not Detected" or " U" does not indicate the sample is analyte free but that the analyte is not detected at or above the PQL Page 1 of 3 DocuSian Envelope ID: 22545EBB-EE51-4116-8CDC-BDD4BA79C16B V NCDW(, Laboratory Section (esufts/Sampfe Comments/QuarifierDefinitions Sample ID: AD13413 I Result/ Method Analysis Qualifier Units Reference Date Validated by Sample Comments IC:Fecal Coliform-62-Counts from all filters = 0. NCDEQ-WSS-Chemistry Lab Data Qualifiers Al The reported value is an average, where at least one result is qualified with a "U". The PQL is used for the qualified result(S) to call B1 Coliform-Countable membranes with less than 20 colonies. Reported value is estimated or is a total of the counts on all filters repor B2 Coliform-Counts from all filters were zero. B3 Coliform-Countable membranes with more than 60 or 80 colonies. The value reported is calculated using the count from the smalle B4 Coliform-Filters have counts of both >60 or 80 and <20. Reported value is estimated or is a total of the counts on all filters reported B5 Coliform-Too many colonies were present; too numerous to count (TNTC). TNTC is generally defined as >150 colonies. B6 Col iform-Esti mated Value. Blank contamination evident. B7 Coliform-Many non-coliform or non-enterococcus colonies or interfering non-coliform or non-enterococcus growth present. In this cc BB1 MPN-No wells or tubes gave a positive reaction. Value based upon the appropriate MPN Index and reported as a less than "<" valu BB2 MPN-All wells or tubes gave positive reactions. Value based upon the MPN Index and reported as a greater than ">" value. C Total residual chlorine was present in sample upon receipt in the laboratory; value is estimated. G1 BOD-The dissolved oxygen (DO) depletion of the dilution water blank exceeded 0.2 mg/L. G2 BOD-The bacterial seed controls did not meet the requirement of a DO depletion of at least 2.0 mg/L and/or a DO residual of at lea: G3 BOD-No sample dilution met the requirement of a DO depletion of at least 2.0 mg/L and/or a DO residual of at least 1.0 mg/L. G4 BOD-Evidence of toxicity. This is generally characterized by a significant increase in the BOD value as the sample concentration de G5 BOD-The glucose/ glutamic acid standard exceeded the range of 198 ± 30.5 mg/L. G7 BOD-Less than 1 mg/L DO remained for all dilutions set. The reported value is an estimated greater than value and is calculated foi G8 BOD-Oxygen usage is less than 2 mg/L for all dilutions set. The reported value is an estimated less than value and is calculated for G9 BOD-The DO depletion of the dilution water blank produced a negative value. J1 Surrogate recovery limits have been exceeded. J10 Unidentified peak; estimated value. WSS Chemistry Laboratory>> 1623 Mail Service Center, Raleigh, NC 27699-1623 (919) 733-3908 "Not Detected" or "U" does not indicate the sample is analyte free but that the analyte is not detected at or above the PQL. Page 2 of 3 DocuSian Envelope ID: 22545EBB-EE51-4116-8CDC-BDD4BA79C16B V NCDW(, Laboratory Section (esutts/Sampte Comments/QuarifierDefinitions Sample ID: AD13413 I Result/ Method Analysis � I Qualifier Units Reference Date Validated by J11 The reported value is determined by a one -point estimation rather than against a regression equation. The estimated concentration J12 The calibration verification did not meet the calibration acceptance criterion for field parameters. J2 The reported value failed to meet the established quality control criteria for either precision or accuracy. J3 The sample matrix interfered with the ability to make any accurate determination. J4 The data is questionable because of improper laboratory or field protocols (e.g., composite sample was collected instead of grab, p J5 Temperature limits exceeded (samples frozen or >6°C) during transport or not verifiable (e.g., no temperature blank provided): non- J6 The laboratory analysis was from an unpreserved or improperly chemically preserved sample. The data may not be accurate. J7 This qualifier is used to identify analyte concentration exceeding the upper calibration range of the analytical instrument/method. Th J8 Temperature limits exceeded (samples frozen or >6°C) during storage, the data may not be accurate. J9 The reported value is determined by a one -point estimation rather than against a regression equation. The estimated concentration M Sample and duplicate results are 'but of control". The sample is non -homogenous (e.g., VOA soil). The reported value is the lower, N1 Presumptive evidence and estimated value. The component has been tentatively identified base on mass spectral library. N2 There is an indication that the analyte is present, but quality control requirements for confirmation were not met (i.e., presence of N3 This code shall be used if the level is too low to permit accurate quantification, but the estimated concentration is less than the labo N4 This code shall be used if the level is too low to permit accurate quantification, but the estimated concentration is less than the labo N5 The component has been tentatively identified based on a retention time standard. P Elevated PQL* due to matrix interference and/or sample dilution. Q1 Holding time exceeded prior to receipt by lab. Q2 Holding time exceeded following receipt by lab. S Not enough sample provided to prepare and/or analyze a method -required matrix spike (MS) and/or matrix spike duplicate (MSD). U Indicates that the analyte was analyzed for but not detected above the reported practical quantitation limit*. The number value repo U, J6 The laboratory analysis was from an unpreserved or improperly chemically preserved sample. The data may not be accurate. UU Indicates that the analyte was not detected by a screen analysis. The number value was determined by a one -point estimation at tf V Indicates the analyte was detected in both the sample and the associated method blank. Note: The value in the blank shall not be s X1 Sample not screened for this compound. X2 Sampled, but analysis lost or not performed -field error. X3 Sampled, but analysis lost or not performed -lab error. Y Elevated PQL* due to insufficient sample size. Z1 Inability to analyze the sample. Z2 Questions concerning data reliability. J13 Standards used for this analyte are from an uncertified source. These are the only standards currently available for the analyte. WSS Chemistry Laboratory>> 1623 Mail Service Center, Raleigh, NC 27699-1623 (919) 733-3908 "Not Detected" or " Ll" does not indicate the sample is analyte free but that the analyte is not detected at or above the PQL. Page 3 of 3 DocuSign Envelope ID: 22545EBB-EE51-4116-8CDC-BDD4BA79C16B AD13414 North Carolina Division of Water Resources Water Sciences Section Laboratory Results Loc. Descr.: 1111 MONTEREY VALLEY DRIVE County: Orange Collector: M HALL VisitlD Region: Raleigh Report To RRO Location ID: W1 DISCHARGE River Basin CPF Collect Date: 08/22/2023 Priority COMPLIANCE Emergency Collect Time: 12_01 Sample Matrix: GROUNDWATER COC Yes/No Sample Depth Loc. Type: Water Supply Final Report If this report is labeled preliminary report, the results have not been validated. Do not use for Regulatory purposes. Result/ Method Analysis CAS # AnalVte Name PQL Qualifier Units Reference Date Validated by LAB Sample temperature at receipt by lab 0.4 °C 8/22/23 MSWIFT Conform, MF Fecal in liquid 1 MIC 1 B2 CFU/100ml SM 9222 D-1997 8/22/23 JJURGEVICH Conform, MF Total in liquid 1 3500 B3 CFU/100ml SM 9222 B-1997 8/22/23 JJURGEVICH E701177 NO2+NO3 as N in liquid 0.03 NUT 0.79 mg/L as N EPA 353.2 REV 2 8/30/23 ALWILLIAMS 24959-67-9 Bromide 0.4 WET 0.4 U mg/L EPA300.0 rev2.1 8/28/23 ALWILLIAMS 16887-00-6 Chloride 1.0 4.7 mg/L EPA300.0 rev2.1 8/28/23 ALWILLIAMS 16984-48-8 Fluoride 0.4 0.4 U mg/L EPA300.0 rev2.1 8/28/23 ALWILLIAMS 14808-79-8 Sulfate 2.0 3.3 mg/L EPA300.0 rev2.1 8/28/23 ALWILLIAMS Total Dissolved Solids in liquid 12.5 137 mg/L SM 2540 C-1997 8/29/23 ALWILLIAMS 7440-22-4 Ag by ICPMS 1.0 MET 1.0 U ug/L EPA200.8 Rev5.4 9/6/23 JJURGEVICH 7429-90-5 Al by ICP 50 50 U ug/L EPA200.7 Rev4.4 8/29/23 JJURGEVICH 7440-38-2 As by ICPMS 2.0 2.0 U ug/L EPA200.8 Rev5.4 9/6/23 JJURGEVICH 7440-70-2 Ca by ICP 0.10 20 mg/L EPA200.7 Rev4.4 8/29/23 JJURGEVICH 7440-43-9 Cd by ICPMS 0.50 0.50 U ug/L EPA200.8 Rev5.4 9/6/23 JJURGEVICH 7440-48-4 Cobalt by ICP 50 50 U ug/L EPA200.7 Rev4.4 8/29/23 JJURGEVICH 7440-47-3 Cr by ICPMS 5.0 5.0 U ug/L EPA200.8 Rev5.4 9/6/23 JJURGEVICH 7440-50-8 Cu by ICPMS 2.0 25 ug/L EPA200.8 Rev5.4 9/6/23 JJURGEVICH 7439-89-6 Fe by ICP 50 50 U ug/L EPA200.7 Rev4.4 8/29/23 JJURGEVICH 7440-09-7 K by ICP 0.10 0.86 mg/L EPA200.7 Rev4.4 8/29/23 JJURGEVICH 7439-95-4 Mg by ICP 0.10 6.8 mg/L EPA200.7 Rev4.4 8/29/23 JJURGEVICH 7439-96-5 Mn by ICP 10 10 U ug/L EPA200.7 Rev4.4 8/29/23 JJURGEVICH 7440-23-5 Na by ICP 0.10 10 mg/L EPA200.7 Rev4.4 8/29/23 JJURGEVICH 7440-02-0 Ni by ICPMS 2.0 2.7 ug/L EPA200.8 Rev5.4 9/6/23 JJURGEVICH 7439-92-1 Pb by ICPMS 2.0 2.0 U ug/L EPA200.8 Rev5.4 9/6/23 JJURGEVICH 7782-49-2 Se by ICPMS 1.0 1.0 U ug/L EPA200.8 Rev5.4 9/6/23 JJURGEVICH 7440-66-6 Zn by ICPMS 10 10 U ug/L EPA200.8 Rev5.4 9/6/23 JJURGEVICH WSS Chemistry Laboratory>> 1623 Mail Service Center, Raleigh, NC 27699-1623 (919) 733-3908 "Not Detected" or " U" does not indicate the sample is analyte free but that the analyte is not detected at or above the PQL Page 1 of 3 DocuSian Envelope ID: 22545EBB-EE51-4116-8CDC-BDD4BA79C16B V NCDW(, Laboratory Section (esufts/Sampfe Comments/QuarifierDefinitions Sample ID: AD13414 I Result/ Method Analysis Qualifier Units Reference Date Validated by Sample Comments IC:Fecal Coliform-62-Counts from all filters = 0. IC:Total Coliform-133-Counts >60 or >80 colonies. NCDEQ-WSS-Chemistry Lab Data Qualifiers Al The reported value is an average, where at least one result is qualified with a "U". The PQL is used for the qualified result(S) to call B1 Coliform-Countable membranes with less than 20 colonies. Reported value is estimated or is a total of the counts on all filters repor B2 Coliform-Counts from all filters were zero. B3 Coliform-Countable membranes with more than 60 or 80 colonies. The value reported is calculated using the count from the smalle B4 Coliform-Filters have counts of both >60 or 80 and <20. Reported value is estimated or is a total of the counts on all filters reported B5 Coliform-Too many colonies were present; too numerous to count (TNTC). TNTC is generally defined as >150 colonies. B6 Col iform-Esti mated Value. Blank contamination evident. B7 Coliform-Many non-coliform or non-enterococcus colonies or interfering non-coliform or non-enterococcus growth present. In this cc BB1 MPN-No wells or tubes gave a positive reaction. Value based upon the appropriate MPN Index and reported as a less than "<" valu BB2 MPN-All wells or tubes gave positive reactions. Value based upon the MPN Index and reported as a greater than ">" value. C Total residual chlorine was present in sample upon receipt in the laboratory; value is estimated. G1 BOD-The dissolved oxygen (DO) depletion of the dilution water blank exceeded 0.2 mg/L. G2 BOD-The bacterial seed controls did not meet the requirement of a DO depletion of at least 2.0 mg/L and/or a DO residual of at lea: G3 BOD-No sample dilution met the requirement of a DO depletion of at least 2.0 mg/L and/or a DO residual of at least 1.0 mg/L. G4 BOD-Evidence of toxicity. This is generally characterized by a significant increase in the BOD value as the sample concentration de G5 BOD-The glucose/ glutamic acid standard exceeded the range of 198 ± 30.5 mg/L. G7 BOD-Less than 1 mg/L DO remained for all dilutions set. The reported value is an estimated greater than value and is calculated foi G8 BOD-Oxygen usage is less than 2 mg/L for all dilutions set. The reported value is an estimated less than value and is calculated for G9 BOD-The DO depletion of the dilution water blank produced a negative value. J1 Surrogate recovery limits have been exceeded. J10 Unidentified peak; estimated value. WSS Chemistry Laboratory>> 1623 Mail Service Center, Raleigh, NC 27699-1623 (919) 733-3908 "Not Detected" or "U" does not indicate the sample is analyte free but that the analyte is not detected at or above the PQL. Page 2 of 3 DocuSian Envelope ID: 22545EBB-EE51-4116-8CDC-BDD4BA79C16B V NCDW(, Laboratory Section (esutts/Sampte Comments/QuarifierDefinitions Sample ID: AD13414 I Result/ Method Analysis � I Qualifier Units Reference Date Validated by J11 The reported value is determined by a one -point estimation rather than against a regression equation. The estimated concentration J12 The calibration verification did not meet the calibration acceptance criterion for field parameters. J2 The reported value failed to meet the established quality control criteria for either precision or accuracy. J3 The sample matrix interfered with the ability to make any accurate determination. J4 The data is questionable because of improper laboratory or field protocols (e.g., composite sample was collected instead of grab, p J5 Temperature limits exceeded (samples frozen or >6°C) during transport or not verifiable (e.g., no temperature blank provided): non- J6 The laboratory analysis was from an unpreserved or improperly chemically preserved sample. The data may not be accurate. J7 This qualifier is used to identify analyte concentration exceeding the upper calibration range of the analytical instrument/method. Th J8 Temperature limits exceeded (samples frozen or >6°C) during storage, the data may not be accurate. J9 The reported value is determined by a one -point estimation rather than against a regression equation. The estimated concentration M Sample and duplicate results are 'but of control". The sample is non -homogenous (e.g., VOA soil). The reported value is the lower, N1 Presumptive evidence and estimated value. The component has been tentatively identified base on mass spectral library. N2 There is an indication that the analyte is present, but quality control requirements for confirmation were not met (i.e., presence of N3 This code shall be used if the level is too low to permit accurate quantification, but the estimated concentration is less than the labo N4 This code shall be used if the level is too low to permit accurate quantification, but the estimated concentration is less than the labo N5 The component has been tentatively identified based on a retention time standard. P Elevated PQL* due to matrix interference and/or sample dilution. Q1 Holding time exceeded prior to receipt by lab. Q2 Holding time exceeded following receipt by lab. S Not enough sample provided to prepare and/or analyze a method -required matrix spike (MS) and/or matrix spike duplicate (MSD). U Indicates that the analyte was analyzed for but not detected above the reported practical quantitation limit*. The number value repo U, J6 The laboratory analysis was from an unpreserved or improperly chemically preserved sample. The data may not be accurate. UU Indicates that the analyte was not detected by a screen analysis. The number value was determined by a one -point estimation at tf V Indicates the analyte was detected in both the sample and the associated method blank. Note: The value in the blank shall not be s X1 Sample not screened for this compound. X2 Sampled, but analysis lost or not performed -field error. X3 Sampled, but analysis lost or not performed -lab error. Y Elevated PQL* due to insufficient sample size. Z1 Inability to analyze the sample. Z2 Questions concerning data reliability. J13 Standards used for this analyte are from an uncertified source. These are the only standards currently available for the analyte. WSS Chemistry Laboratory>> 1623 Mail Service Center, Raleigh, NC 27699-1623 (919) 733-3908 "Not Detected" or " Ll" does not indicate the sample is analyte free but that the analyte is not detected at or above the PQL. Page 3 of 3