Loading...
HomeMy WebLinkAboutNC0089206_BIMS Report_20230918United States Environmental Protection Agency Form Approved. EPA Washington, D.C. 20460 OMB No. 2040-0057 Water Compliance Inspection Report Approval expires 8-31-98 Section A: National Data System Coding (i.e., PCS) Transaction Code NPDES yr/mo/day Inspection Type Inspector Fac Type 1 IN 2 u 3 I NCO089206 111 121 23/09/13 I17 18 LC] I 19 I s I 20L] 21111I I I I I I I II I I I I I I I I I I I I I I I I I I I I I I I II I I I I I r6 Inspection Work Days Facility Self -Monitoring Evaluation Rating B1 QA ---------------------- Reserved ------------------- 67 1.0 70 I I 71 1� I 72 L r i � 73 � I 74 79 LJ L-1 I I I I I I I I I80 Section B: Facility Data Name and Location of Facility Inspected (For Industrial Users discharging to POTW, also include Entry Time/Date Permit Effective Date POTW name and NPDES Dermit Number) 10:30AM 23/09/13 21/03/01 Church Street remediation site 2100 N Church St Exit Time/Date Permit Expiration Date Charlotte NC 28202 11:30AM 23/09/13 25/06/30 Name(s) of Onsite Representative(s)/Titles(s)/Phone and Fax Number(s) Other Facility Data Scott Alexander Chinery/ORC/704-509-1777/ Name, Address of Responsible Official/Title/Phone and Fax Number Contacted Gary Myers,105 Boldt Ln Saint Clair MO 63077//636-629-3400/6366290500 No Section C: Areas Evaluated During Inspection (Check only those areas evaluated) Permit 0 Operations & Maintenar 0 Records/Reports 0 Laboratory Section D: Summary of Finding/Comments (Attach additional sheets of narrative and checklists as necessary) (See attachment summary) Name(s) and Signature(s) of Inspector(s) Agency/Office/Phone and Fax Numbers Date Edward Wat Docusigned by: DWR/MRO WQ/ / 4 9/18/2023 CA4CEBFSF85F415... Signature of Management Q A Reviewer Agency/Office/Phone and Fax Numbers Date Docusigned by: fw� H P44-t4 9/18/2023 FA '—F161FB69A2D84A3... EPA Form 3560-3 (Rev 9-94) Previous editions are obsolete. Page# NPDES yr/mo/day Inspection Type NCO089206 I11 12I 23/09/13 117 18 i c i (Cont.) Section D: Summary of Finding/Comments (Attach additional sheets of narrative and checklists as necessary) The exisitng treatment system mechanically failed in May of 2021. Flow to the outfall has been suspended. The onsite wells are not adequately secured. Please take action to secure these wells. Monitor wells that are not being used as part post injection GW sampling network should be abandoned by an NC certified drilling contractor to avoid the introduction of constituents into the aquifer. Due the cost of repairing the permitted pump and treat system, the permittee should consider requesting the rescission of the current NPDES permit. Page# Permit: NCO089206 Inspection Date: 09/13/2023 Owner -Facility: Church Street remediation site Inspection Type: Compliance Evaluation Operations & Maintenance Yes No NA NE Is the plant generally clean with acceptable housekeeping? 0 ❑ ❑ ❑ Does the facility analyze process control parameters, for ex: MLSS, MCRT, Settleable ❑ ❑ ❑ Solids, pH, DO, Sludge Judge, and other that are applicable? Comment: The treatment system settling tank is about 3/4 full of fluid. The fluid should be sampled for CVOCs to detemrine that chlorinated solvents are not present in the tank. The tank should be emptied and properly capped tp prevent fluid from entering the tank. Permit Yes No NA NE (If the present permit expires in 6 months or less). Has the permittee submitted a new ■ ❑ ❑ ❑ application? Is the facility as described in the permit? ■ ❑ ❑ ❑ # Are there any special conditions for the permit? ❑ 0 ❑ ❑ Is access to the plant site restricted to the general public? 0 ❑ ❑ ❑ Is the inspector granted access to all areas for inspection? ■ ❑ ❑ ❑ Comment: Recent activities include a UIC deemed permit # WI0300461 infection event to aid with the degradation of the chlorinated solvents present at the site. The iniectant is agent being employed is Sodium Persulfate. Three wells were installed as infection points. Some of the exisiting MWs are being used to measure the degradation of the CVOCs. Page# 3