Loading...
HomeMy WebLinkAboutWQ0033770_Monitoring - 07-2023_20230914Monitoring Report Submittal Permit Number#* Name of Facility:* Month:* July Report Information WQ0033770 Carolina Plantation WWTP Type * Revised - NDMR, NDAR-1, NDAR-2, NDMLR Year:* 2023 Upload Document* Carolina Plantations NDAR NDMR July 2023 - 5.23MB Revised.pdf PDF Only Please upload one PDF containing all applicable monitoring reports (i.e., NDMR, NDAR-1, NDAR-2, NDMLR, GW-59). Confirmation Email Address: * dwhicher@onswc.com Name of Submitter: * Dominic Whicher Signature: Date of submittal: 9/14/2023 This will be filled in automatically Initial Review Reviewer: Wanda.Gerald Is the project number correct?* WQ0033770 Is the monitoring report accepted?* Yes No Regional Office* Wilmington Reviewer: _anonymous Review Date: 9/19/2023 FORM: NDMR 05-16 NON -DISCHARGE MONITORING REPORT (NDMR) Page I_ of '3 Permit No.: WQ0033770 Facility Name: Carolina Plantation WWTP County: Onslow Month: July Year: 2023 PPI: 001 Flow Measuring Point: ❑ influent Q Effluent [] No flow generated Parameter Monitoring Point: ❑ influent Effluent ❑ Groundwater towering ❑ Surface water Parameter Code 50050 00310 00940 50060 1 31616 00610 1 00625 00620 00600 00400 00665 70300 00530 OT _ m a) < E U~ O c O N ~ O Lt. U _ U O U E < Z 0 L Ili- Z = O L a m -Z 'O N O V 0 c -0 OO 24-hr hrs GPD mg/L mg/L mg/L /t/100 mL mg/L mg/L mg/L mg/L su mg/L mg/L mg/L 1 09:45 1 2.5 142,030 2 09:15 1 161,150 3 08:30 2 163,950 0.26 7.5 4 07:45 2 151,770 H H 5 08:00 3 175,980 2.6 0.84 3 4.05 4.26 0,05 4.36 7.3 0.69 1 11 6 08:00 3 194,250 2 0.41 <1 2,19 3.13 0.05 3.18 7.4 0.96 9.8 7 08:30 2.5 168,800 0.39 7.3 8 09:30 1.5 145,320 9 08:45 1 159,440 101 08:00 2 183,050 1.2 7.2 11 08:00 3 152,580 0.15 7.5 12 08:15 2 152,510 2.8 69 0.74 <1 0 55 1.33 0.06 139 7.3 1.15 470 11 13 07:45 3 156,090 27 0.82 <1 0 16 1.44 0.08 1.52 7.4 0.73 7.2 14 08:30 3 159,590 0,96 7.5 15 09:45 2 152,050 16 09:30 1 163,370 17 0815 3 179,880 0.33 7.5 18 08:30 3 153,640 0.76 7.4 19 07:45 2.5 159,410 <2 0.42 <1 0.23 2.35 <.04 2.35 7.4 1.48 7.3 20 08:00 2 154,690 <2 0.19 <1 0 37 0.75 0.04 0,79 7.7 0.89 4.3 21 08:00 3 147,830 0.68 7.3 22 09:45 2 147,750 23 09:45 1 167,110 24 08:00 3 175,700 0.26 7.2 25 08:00 2 1 150,240 0.84 7.4 26 08:15 2.5 160,650 2 0.95 1 132 3.74 0.04 3.82 7.5 0.43 7.3 27 08:30 3 161,330 <2 1.3 14 0,77 1.54 <.04 1.57 1 7.3 0.53 3.4 28 08:00 2 157,790 f 0.58 7.5 29 08:30 2 155,850 30 08:30 1 151,120 31 08:00 3 180,050 0.69 T6 Average: 160,805 1.51 69.00 0.61 1.60 1.21 2.32 0.04 2.37 0.86 470.00 7.66 Daily Maximum: 194,250 2.80 69.00 1.30 14.00 4.05 4.26 0.08 4.36 1 7 70 1.48 470.00 1 11.00 Daily Minimum: 142,030 2.00 69.00 0.15 1.00 0.16 0.75 0.04 0.79 7.20 0.43 470.00 1 3.40 Sampling Type: Recorder Composite Composite Grab Grab Composite Composite Composite Composite Crab Composite Composite Composite Monthly Limit: 150,000 10 1 14 4 1 10 4 2 15 Daily Limit: Sample Frequency:1 Continuous i 2 X Week 3 X Year 5 X Week 2 X Week 2 X Week 2 X Week 1 2 X Week 2 X Week 5 X Week 1 2 X Week 3 X Year 2 X Week FORM: NDMR 05-16 NON -DISCHARGE MONITORING REPORT (NDMR) Page _ of Permit �/L� Facility Name: Carolina Plantation WWTP County: Onslow Month: July Year: 2023 PPI: 002 187100 ❑ Influent Q Effluent ❑ No flow generated Parameter Monitoring Point: ❑ influent ❑ Effluer t Q Groundwater Lowering ❑ Surface viater Parameter Code 50050 00310 00680 00940 50OW 31616 00610 00620 00600 00400 00665 70300 f0 �O f0 N V O E O In O 3 LL rn m V cCn Cp O M oU F-1 0m 'O :E, U 7 C p WU E 0- U .0 E Q d ._. 2 C p Z 3 0 fl_ O O y F-L a d N O N O HQ 24-hr hrs GPD mglL mglL mg/L mg/L #/100 mL mg/L mg/L mg1L su mg/L mg/L 1 09:45 2.5 132.650 2 09:15 1 117,490 3 08:30 2 125,070 4 07:45 2 1 132,650 5 08:00 3 121,280 6 08:00 3 113,700 22 2200 1.56 <.04 14.56 2.6 7 08:30 2.5 136,440 8 09:30 1.5 128,860 9 08:45 1 132,650 10 08:00 2 117,490 11 08:00 3 60,640 121 08:15 1 2 79,590 13 07:45 3 109,910 <2 4.84 29 1100 0.78 0,14 1.86 0.54 240 14 08:30 3 140,230 15 09:45 2 166,760 16 09:30 1 155,390 17 08:15 3 162,970 181 08:30 3 159,180 19 07:45 2.5 87,170 20 08:00 2 90,960 68 19000 0.66 0,66 2.86 1.06 21 08:00 3 162,970 22 09:45 2 170.550 23 09:45 1 166,760 241 08:00 3 140,230 251 08:00 2 174,340 26 08:15 2.5 162,970 27 08:30 3 170,550 <2 1273 0.87 0.06 1 0.26 28 08:00 2 159.180 29 0830 2 181.920 30 0830 1 174,340 311 08:00 3 189,500 Average: 139,496 T20 4.84 29.00 2,765.98 0.97 0.22 5.07 1.12 240.00 Daily Maximum: 189,500 22.00 4.84 29.00 19,000.00 1.56 0.66 14.56 2.60 240.00 Daily Minimum: 60,640 2.00 4.84 29.00 1,100.00 0.66 0.04 1.00 0.26 240.00 Sampling Type: Recorder Grab Grab Grab Grab Grab Grab Grab Grab r.rab Grab Grab Monthly Limit: Daily Limit: 471.400 FORM: NDMR 05-16 NON -DISCHARGE MONITORING REPORT (NDMR) Page ^3 of 7 Sampling Person(s) Certified Laboratories Name: Jeff Jarman Name: Environment 1 Name: Name: Does all monitoring data and sampling frequencies meet the requirements in Attachment A of your permit? ❑ Compliant ® Non -Compliant If the facility is non -compliant, please explain in the space below the reason(s) the facility was not in compliance. Provide in your explanation the date(s) of the non-compliance and describe the corrective action(s) taken. Attach additional sheets if necessary. Out of compliance due to monthly average flow exceeding 150.000 gpd Operator in Responsible Charge (ORC) Certification Permittee Certification ORC: Jeff Jarman Permittee: Old North State Water Company Certification No.: 13491 Signing Official: John McDonald Grade: WW-4 Phone Number: 910-330-8167 Signing Official's Title: Owner Has the ORC changed since the previous NDMR? ❑ yes 0 No Phone Number: Permit Expiration: 10/31/2028 ov�� 8/28/2023 $ a. SidVature Date Signature Date By this signature, I certify that this report is accurrate and complete to the best of my knowledge. I certify, under penalty of law, that this document and all attachments were prepared under my direction or supervision in accordance with a system designed to assure that all qualified personnel properly gathered and evaluated the information submitted. Based on my inquiry of the person or persons who manage the system, or those persons directly responsible for gathering the information, the information submitted is, to the best of my knowledge and belief, true, accurate, and complete. I am aware that there are significant penalties for submitting false information, including the possibility of fines and imprisonment for knowing violations. Mail Original and Two Copies to: Division of Water Resources Information Processing Unit 1617 Mail Service Center Raleigh, North Carolina 27699-1617 User Friendly Name Official Parameter Name DWQ Accepted Units 00010 Temperature Temperature, Water Deg. Centigrade °C 00076 Turbidity Turbidity, HCH Turbidimeter NTU 00092 Flow - Maximum Flow, Maximum Flow Range GIRD 00094 Conductivity Conductivity PC) 00125 Dichlorobenzene Dichlorobenzene (Isomers) M/P In Water ug/l pg/L 00300 Dissolved Oxygen DO, Oxygen, Dissolved mg/L 00310 BOD5 BOD, 5-Day (20 Deg. C) mg/L 00340 COD COD, Oxygen Demand, Chem. (High Level) mg/L 00400 pH pH su 00480 Salinity Salinity mg/L 00515 Total Filterable Residue Residue, Tot Fltrble (dried at 105C) mg/L 00530 Total Suspended Solids Solids, Total Suspended mg/L 00545 Settleable Solids Solids, Settleable mL/L 00556 Oil Et Grease Oil & Grease mg/L 00600 Total Nitrogen Nitrogen, Total (as N) mg/L 00610 Ammonia Nitrogen, Ammonia Total (as N) mg/L 00615 Nitrite Nitrogen, Nitrite Total (as N) mg/L 00620 Nitrate Nitrogen, Nitrate Total (as N) mg/L 00625 Total Kjeldahl Nitrogen Nitrogen, Kjeldahl, Total (as N) mg/L 00630 Nitrite + Nitrate Nitrite plus Nitrate Total 1 DET. (as N) mg/L 00660 Ortho Phosphate Phosphate, Ortho (as PO4) mg/L 00665 Total Phosphorus Phosphorus, Total (as P) mg/L 00670 Organic Phosphorus Phosphorous, Total Organic (as P) mg/L 00680 Total Organic Carbon Carbon, Tot Organic (TOC) mg/L 00681 Dissolved Organic Carbon Carbon, Dissolved Organic (As C) mg/L 00916 Calcium Calcium, Total (as Ca) mg/L 00927 Magnesium Magnesium, Total (as Mg) mg/L 00929 Sodium Sodium, Total (as Na) mg/L 00931 Sodium Adsorption Ratio Sodium Adsorption Ratio Ratio 00937 Potassium Potassium, Total (as K) mg/L 00940 Chloride Chloride (as Cl) mg/L 00945 Sulfate Sulfate, Total (as SO4) mg/L 01002 Arsenic Arsenic, Total (as As) mg/L 01007 Barium Barium, Total (as Ba) mg/L 01022 Boron Boron, Total (as B) mg/L 01027 Cadmium Cadmium, Total (as Cd) mg/L 01034 Chromium Chromium, Total (as Cr) mg/L 01042 Copper Copper, Total (as Cu) mg/L 01045 Iron Iron, Total (as Fe) mg/L 01051 Lead Lead, Total (as Pb) mg/L 01055 Manganese Manganese, Total (as Mn) mg/L 01067 Nickel Nickel, Total (as Ni) mg/L 01077 Silver Silver, Total (as Ag) mg/L 01092 Zinc Zinc, Total (as Zn) mg/L 01147 Selenium Selenium, Total (as Se) mg/L 01284 ND Application Rate Non -Discharge Application Rate in/yr 31504 Total Coliform Coliform, Total MF, Immed,LES Endo Agar #/100 mL 31505 Total Coliform Coliform, Tot, MPN, Completed, (100 mL) MPN/100 mL 31613 Fecal Coliform Coliform, Fecal MF, M-FC Agar,44.5C,24hr #/100 mL 31616 Fecal Coliform Coliform, Fecal MF, M-FC Broth,44.5C #/100 mL 32106 Chloroform Chloroform mg/L 32730 Phenolics - Recoverable Phenolics, Total Recoverable mg/L 32730 Phenols mg/L 34469 Pyrene Pyrene pg/L 34694 Phenol - Single Phenol, Single Compound mg/L 38260 Surfactants Surfactants (MBAS) mg/L 50050 Flow Flow, in conduit or thru treatment plant GPD 50060 Total Residual Chlorine Chlorine, Total Residual mg/L 70295 Total Dissolved Solids Solids, Total Dissolved mg/L 70300 Total Dissolved Solids Solids, Total Dissolved- 180 Deg.0 mg/L 70318 % Solids Solids, Total, Percent % 71880 Formaldehyde Formaldehyde mg/L 71900 Mercury Mercury, Total (as Hg) mg/L 78732 Volatile Compounds Volatile Compounds, (GUMS) Yes/No 80082 Carbonaceous BOD BOD, Carbonaceous 05 Day, 20C mg/L 81639 Total Kjeldahl Nitrogen Nitrogen Kjeldalh, Total (TKN) lbs/ac 81688 Ethylene Glycol Ethylene glycol pg/L 82385 Nitrogen Oxides Nitrogen Oxides (as N) mg/L 82546 Water Level Water level, distance from measuring point ft CO310 BODs - Conc. BOD, 5-Day (20 Deg. C) - Concentration mg/L CO530 TSS - Conc. Solids, Total Suspended - Concentration mg/L C0600 Total Nitrogen - Conc. Nitrogen, Total (as N) - Concentration mg/L CO610 Ammonia - Conc. Nitrogen, Ammonia Total (as N) - Concentration mg/L CO665 Total Phosphorus - Conc. Phosphorus, Total (as P) - Concentration mg/L NDVOC Volatile Compounds Volatile Compounds (Effluent) Yes/No WQ01 Reclaimed Water Distributed Flow, Reclaimed Water Distributed Gallons WQ09C Plant Available Nitrogen Plant Available Nitrogen - Concentration mg/L WQ09 Plant Available Nitrogen Plant Available Nitrogen - Loading mg/L ., FORM: NDAR-2 05-16 NON -DISCHARGE APPLICATION REPORT (NDAR-2) Page of Permit No.: W00033770 Facility Name: Carolina Plantation WWTP County: Onslow Month: July Year: 2023 Did infiltration occur at Site Name: 1 Site Name: 2 Site Name: 3 Site Name: 4 this facility? Area (acres): 0.49 Area (acres): 0.49 Area (acres): 0.49 Area (acres): 0.49 Q YES [:,NO Rate (GPD/ft): 3.48 Rate (GPD/ft): 3.48 Rate (GPD/ft): 3.48 Rate (GPD/ft): 3.48 Weather Freeboard Site Infiltrated? ❑ YES QQ NO Site Infiltrated? 0 YES ❑ NO Site Infiltrated? R YES ❑ No Site Infiltrated? ❑ YES NO o d mE c o a 2 ^y °'tea tm 2 O O. f/a M ^y ova � O. a o ! o a J m R .1 O J > WLL �Q O B C m E. o a m i £ -O. C0 c O o Umm ' l m .2 o iQ Om E c a O J Q ` O .D m E D CL i Q E c O m _ U« O U o y6 m °F in ft ft gal min GPD/ftZ ft gal min GPD/ftZ ft gal min GPD/ft2 ft gal min GPD/ftZ ft 1 C 73 43,363 1000 2.03 0 0.00 48,467 1000 2.27 53,415 1000 2.50 2 CL 79 38,931 1000 1.82 0 0.00 43,264 1000 2.03 39,074 1000 1.83 3 C 78 56,076 1000 2.63 0 0.00 41.623 1000 1.95 43,238 1000 2.03 4 PC 75 51,631 1000 2.42 0 0.00 49,474 1000 2.32 55,584 1000 2.60 5 CL 81 51.240 1000 2.40 5.00 0 0.00 8.00 42,600 1000 2.00 5.00 51,919 1000 2.43 5.00 6 1 R 79 3 54,600 1000 2.56 0 0.00 48,466 1000 2.27 48,328 1000 2.26 7 C 65 50,880 1000 2.38 0 0.00 40,168 1000 1-88 49,039 1000 2.30 8 CL 82 44,893 1000 2.10 0 0.00 43,635 1000 2.04 53,058 1000 2.49 9 R 84 44,508 1000 2.09 0 0.00 55,424 1000 2.60 53,301 1000 2.50 10 C 79 47,628 1000 2.23 0 0.00 43,205 1000 2.02 40,169 1000 1.88 11 R 84 48,684 1000 2.28 0 0.00 43,466 1000 2.04 44,512 1000 2.09 121 C 77 40,863 1000 1.91 5.00 0 0.00 8.00 43,351 1000 2.03 5,00 39,162 1000 1.83 5,00 131 CL 84 53,727 1000 2.52 0 0.00 43,426 1000 2.03 44,994 1000 2.11 14 CI 73 39,800 1000 1.86 0 0.00 43,968 1000 2.06 44,577 1000 2.09 15 CL 81 48,678 1000 2.28 0 0.00 47,677 1000 2.23 54,318 1000 2.54 16 CL 68 48,698 1000 2.28 0 0.00 39,831 1000 1.87 40,933 1000 1.92 17 C 78 56,308 1000 2.64 0 0.00 45141 1000 2.11 55,635 1000 2.61 18 CI 83 52,000 1000 2.44 0 0.00 44.327 1000 2.08 53,141 1000 2.49 191 CI 67 44.635 1000 2.09 5.00 0 0.00 8.00 46,202 1000 2.16 5.00 50,340 1000 2.36 5.00 20 CL 79 53,329 1000 2.50 0 0.00 39,352 1000 1.84 50,908 1000 2.39 21 C 85 56,364 1000 2.64 0 0.00 51,473 1000 2.41 47,170 1000 2.21 22 C 85 50,698 1000 2.38 1 0 0.00 48,586 1000 2.28 46,898 1000 2.20 23 CL 66 46,969 1000 2.20 0 0.00 54,819 1000 2.57 55,209 1000 2.59 24 R 85 1 53,053 1000 2.49 0 0.00 49,203 1000 2.31 55,281 1000 2.59 251 CL 75 48,230 1000 2.26 0 0.00 54.113 1000 2.54 45,783 1000 2.14 261 C 69 55,848 1000 2.62 4.00 0 0.00 8.00 44,355 1 1000 2.08 5,00 1 50.262 1000 2.35 5.00 27 R 82 50,797 1000 2.38 0 0.00 49,984 1000 2.34 39,400 1000 1.85 28 CL 72 53.019 1000 2.48 0 0.00 43,966 1000 206 48,734 1000 2.28 29 CL 73 46,377 1000 2.17 0 0.00 40,739 1000 1.91 52,402 1000 2.46 30 PC 69 56.099 1000 2,63 0 42,752 1000 2.00 44,071 1000 2.06 31 CL 88 49,010 1000 2.30 44,515 1000 2.09 51,972 1000 2.43 Monthly Loading (GPD/ftZ): 2.32 M0 EOO 2.14 2.27 Year to Date Loading GPD/ftZ FORM: NDAR-2 05-16 NON -DISCHARGE APPLICATION REPORT (NDAR-2) Page L of Did the application rates exceed the limits in Attachment B of your permit? I] Compliant Non -Compliant If not a basin, were the sites kept free of vegetation and raked? p Compliant ❑ Non -compliant If not a basin, were there any instances of effluent ponding in or runoff from the sites? [Z Compliant ❑ Non -Compliant If a basin, were there any instances of breakout from the berms? l2 Compliant ❑ Non -Compliant Was the onsite automatically activated standby power source tested and operational? Q Compliant ❑ Non -Compliant If the facility is non -compliant, please explain in the space below the reason(s) the facility was not in compliance. Provide in your explanation the date(s) of the non-compliance and describe the corrective action(s) taken. Attach additional sheets if necessary. Operator in Responsible Charge (ORC) Certification Permittee Certification ORC: Jeffrey Jarman Permittee: Old North State Water Company Certification No.: 13491 Signing Official: John McDonald Grade: WW-4 Phone Number: 910-330-8167 Signing Official's Title: Has the ORC changed since the previous NDAR-2? ❑ Yes la No Phone Number: Permit Exp.: 10/31/28 1414� 812812023 Signature Date / Signature Date By this signature, I certify that this report is accurrate and complete to the best of my knowledge I certify, under penalty of law, that this document and all attachments were prepared under my direction or supervision in accordance with a system designed to assure that all qualified personnel properly gathered and evaluated the information submitted. Based on my inquiry of the person or persons who manage the system, or those persons directly responsible for gathering the information, the information submitted is, to the best of my knowledge and belief, true, accurate, and complete. I am aware that there are significant penalties for submitting false information, including the possibility of fines and imprisonment for knowing violations. Mail Original and Two Copies to: Division of Water Resources Information Processing Unit 1617 Mail Service Center Formulas = ilyLoadi»g (GPDrft,)Volume Applied (gallons) Area (acres) x 43,560 t` acre Weather Codes Clear C Cloudy CL Partly Cloudy PC Rain R Sleet SL Snow SN