Loading...
HomeMy WebLinkAboutGaston_Well Abandonment_20230915 (12) 1 WELL ABANDONMENT RECORD For Internal Use ONLY: 1.Well Contractor Information: WELL ABANDONMENT DETAILS William J. Miller 7a.For Geoprobe/DPT or Closed-Loop Geothermal Wells having the same Well Contractor Name(or well owner personally abandoning well on his/her property) well construction/depth,only 1 GW-30 is needed. Indicate TOTAL NUMBER of 2927A wells abandoned: NC Well Contractor Certification Number +".c 1 �~c T4 7b.Approximate volume of water remaining in well(s): (gal.) : �. � �� Catlin Engineers & Scientists FOR WATER SUPPLY WELLS ONLY: Company Name �' ,t ^ 7c.Type of disinfectant used: '► -+r: yr � 2.Well Construction Permit#: List all applicable well construction permits(i.e.U/C,County,St ,+dbvtuee d?c.)lfknown 7d.Amount of disinfectant used: 3.Well use(check well use): Water Supply Well: 7e.Sealing materials used(check all that apply): ❑Agricultural ❑Municipal/Public ❑Neat Cement Grout IN Bentonite Chips or Pellets ❑Geothermal(Heating/Cooling Supply) ❑Residential Water Supply(single) ❑ Sand Cement Grout ❑ Dry Clay ❑hidustrial/Commercial ❑Residential Water Supply(shared) ❑Concrete Grout ❑ Drill Cuttings ❑Irrigation ❑Specialty Grout ❑ Gravel Non-Water Supply Well: ❑ Bentonite Slurry S Other(explain under 7g) eMonitoring ❑Recovery Injection Well: 7f.For each material selected above,provide amount of materials used: ❑Aquifer Recharge ❑GroundwaterRemediation Bentonite 50lbs ❑Aquifer Storage and Recovery ❑Salinity Barrier ❑Aquifer Test ❑Stormwater Drainage SOII 50 IbS ❑Experimental Technology ❑Subsidence Control 7g.Provide a brief description of the abandonment procedure: ❑Geothermal(Closed Loop) ❑Tracer ❑Geothermal(Heating/Cooling Return) ❑Other(explain under 7g) Hydrated bentonite to 4 inches below land surface. Soil used to bring opening to grade. Concrete 4.Date well(s)abandoned: 8/3/23 pad and all metal removed. PVC was left in place. 5a.Well location: Ralph G Sellers Jr 00-030142 Facility/Owner Name Facility ID#(if applicable) 8.Certification: 7152 Dallas Cherryville Hwy, Cherryville, NC 28021 8/4/2023 Physical Address,City,and Zip Signature of Certified Well Contractor or Well Owner Date Gaston County 3509492178 ' By signing this form, 1 hereby certify that the ivell(s) was (were) abandoned in County Parcel Identification No.(PIN) accordance with 1 SA NCAC 02C.0100 or 2C.0200 Well Construction Standards Sb.Latitude and longitude in degrees/minutes/seconds or decimal degrees: and that a copy of this record has been provided to the well owner. (if well field,one lat/long is sufficient) 9.Site diagram or additional well details: 35.373787 N -81.333959 W You may use the back of this page to provide additional well site details or well abandonment details. You may also attach additional pages if necessary. CONSTRUCTION DETAILS OF WELL(S)BEING ABANDONED SUBMITTAL INSTRUCTIONS Attach well constniction record(s)ifavailable. For nntlliple injection or non-walersupply wells ONLY with the same conslructiorabandomaent,you can submit one form. 10a. For All Wells: Submit this form within 30 days of completion of well 6a.Well ID#: Mw-15 abandonment to the following: Division of Water Resources,Information Processing Unit, 6b.Total well depth: 30 (ft.) 1617 Mail Service Center,Raleigh,NC 27699-1617 10b.For Injection Wells: In addition to sending the form to the address in 10a 6c.Borehole diameter: 8.25 (in.) above, also submit one copy of this'form within 30 days of completion of well abandonment to the following: 6d.Water level below ground surface: 18.98 (ft.) Division of Water Resources,Underground Injection Control Program, 1636 Mail Service Center,Raleigh,NC 27699-1636 6e.Outer casing length(if known): NA (ft.) 10c.For Water Supply&Iniection!Wells: In addition to sending the form to the address(es)above,also submit one copy of this form within 30 days of completion of well abandonment to the county health department of the county where 6f.Inner casing/tubing length(if known): 15 abandoned. 6g.Screen length(if known): 15 Form GW-30 North Carolina Department of Environmental Quality-Division of Water Resources Revised 2-22-2016