September 08, 2023
Crystal Walters
Dunescape Villas Condominium Owners Association Inc
PO Box 4455
Emerald Isle, NC 28594-4455
SUBJECT: Compliance Inspection Report
Dunescape Villas WWTF
Non -discharge Permit No. WQ0003044
Carteret County
Dear Permittee:
The North Carolina Division of Water Resources conducted an inspection of the Dunescape Villas WWTF
on 8/24/2023. This inspection was conducted to verify that the facility is operating in compliance with
the conditions and limitations specified in Non -discharge Permit No. WQ0003044. The findings and
comments noted during this inspection are provided in the enclosed copy of the inspection report
entitled "Compliance Inspection Report".
There were no significant issues or findings noted during the inspection and therefore, a response to this
inspection report is not required, however please note that this permit has expired. A renewal application
should be submitted to the Non -discharge Permitting Branch.
If you should have any questions, please do not hesitate to contact Geoff Kegley with the Water
Quality Regional Operations Section in the Wilmington Regional Office at 910-796-7215 or via email at
geoff.kegley@deq.nc.gov.
ATTACHMENTS
Cc: DWR files — Laserfiche
Don O'Mara - ORC
Sincerely,
DocuSigned by: I
ivWl 5-�7 1 i,
E3ABA14AC7DC434...
Morella Sanchez -King, Regional Supervisor
Water Quality Regional Operations Section
Wilmington Regional Office
Division of Water Resources, NCDEQ
D North Carolina Department of Environmental quality I Division of Water Resources
,./ Wiimington Regional Office 1127 Cardinal Drive Extension I Wilmington. North Carolina 26405
910.796,7215
DocuSign Envelope ID: 009E3475-06B1-4EBF-A56F-3E92CBDC288B
Comoliance Insoection Resort
Permit: WQ0003044 Effective: 04/19/17 Expiration: 03/31/22 Owner: Dunescape Villas Condominium Owners
Association Inc
SOC: Effective: Expiration: Facility: Dunescape Villas WWTF
County: Carteret 2111 W Fort Macon Rd
Region: Wilmington
Atlantic Beach NC 28512
Contact Person: Crystal Walters
Title:
Phone: 252-354-6333
Directions to Facility:
Located on Bouge Banks, on the north side of Hwy 58. It is 1.9 miles west of the entrance to Atlantic Beach.
System Classifications: WW3.,
Primary ORC: Donald P Omara Certification: 7904 Phone: 252-247-9167
Secondary ORC(s):
On -Site Representative(s):
Related Permits:
Inspection Date: 08/24/2023 Entry Time 11:30AM Exit Time: 01:OOPM
Primary Inspector: Geoff Kegley Docusigned by. Phone:
Secondary Inspector(s): �
C017E2515D3B417...
Tyler G Benson
Reason for Inspection: Routine Inspection Type: Compliance Evaluation
Permit Inspection Type: High Rate Infiltration
Facility Status: Compliant ❑ Not Compliant
Question Areas:
Treatment Flow Measurement -Effluent Treatment Flow Measurement -Influent Miscellaneous Questions
Treatment Flow Measurement -Water Treatment Treatment Barscreen
Use Records
Treatment Filters Record Keeping Treatment Activated Sludge
Treatment Disinfection End Use -Infiltration Treatment Flow Measurement
Standby Power
(See attachment summary)
Page 1 of 6
DocuSign Envelope ID: 009E3475-06B1-4EBF-A56F-3E92CBDC288B
Permit: WQ0003044 Owner - Facility: Dunescape Villas Condominium Owners Association Inc
Inspection Date: 08/24/2023 Inspection Type: Compliance Evaluation Reason for Visit: Routine
Inspection Summary:
A routine compliance inspection of Dunescape Villas WWTF was conducted on August 24, 2023. The purpose of the
evaluation was to verify that the facility is operating in compliance with the conditions and limitations specified in Permit
WQ0003044. Don O'Mara — ORC was present during the inspection.
The Dunescape Villas WWTF is permitted for 55,000 GPD and consists of:
• 6-mm fine screen
• 17,950 gallon flow EQ basin
• two 17,350 gallon anoxic basins
• two 17,350 gallon aerobic basins
• two 43,390 gallon sequencing batch reactors (SBR)
• 11,780 gallon post flow EQ basin
• two Hydrotech tertiary filters
• two UV disinfection units
• 11,220 gallon anaerobic digester
• effluent flow measuring device
• 11,970 gallon dosing tank
• Disposal via a high -rate infiltration system consisting of three 0.08 acre surface LPP fields.
The current facility was constructed and put into operation in July 2017 to replace the old plant.
The permit expired on March 31, 2022. A renewal application needs to be submitted.
There have been no effluent violations since the last inspection in 2021. A review of groundwater monitoring show some
erratic TDS limit exceedances in MW-6 and one isolated Nitrate exceedance in MW-5.
The facility is compliant with Non -Discharge Permit WQ0003044. Please review the comment sections of the inspection
report for more details.
Page 2 of 6
DocuSign Envelope ID: 009E3475-06B1-4EBF-A56F-3E92CBDC288B
Permit: WQ0003044
Inspection Date: 08/24/2023
Owner - Facility: Dunescape Villas Condominium Owners Association Inc
Inspection Type: Compliance Evaluation Reason for Visit: Routine
Type
Yes No NA NE
Reuse (Quality)
❑
Lagoon Spray, LR
❑
Activated Sludge Spray, LR
❑
Single Family Spray, LR
❑
Activated Sludge Spray, HR
❑
Activated Sludge Drip, LR
❑
Recycle/Reuse
❑
Single Family Drip
❑
Infiltration System
Treatment Yes No NA NE
Are Treatment facilities consistent with those outlined in the current permit? 0 ❑ ❑ ❑
Do all treatment units appear to be operational? (if no, note below.) 0 ❑ ❑ ❑
Comment: Old plant has been decommissioned.
Treatment Flow Measurement -Influent
Yes No NA NE
Is flowmeter calibrated annually?
❑
❑ ❑
Is flowmeter operating properly?
❑
❑ ❑
Does flowmeter monitor continuously?
❑
❑ ❑
Does flowmeter record flow?
❑
❑ ❑
Does flowmeter appear to monitor accurately?
❑
❑ ❑
Comment:
Treatment Flow Measurement -Water Use Records Yes No NA NE
Is water use metered? ❑ ❑ ❑
Are the daily average values properly calculated? ❑ ❑ 0 ❑
Comment:
Treatment Flow Measurement -Effluent Yes No NA NE
Is flowmeter calibrated annually? ❑ ❑ ❑
Is flowmeter operating properly? ❑ ❑ ❑
Does flowmeter monitor continuously? ❑ ❑ ❑
Does flowmeter record flow? ❑ ❑ ❑
Does flowmeter appear to monitor accurately? 0 ❑ ❑ ❑
Comment: There are 3 flowmeters to each infiltration field and are used for reporting flow. They were
calibrated on 5/24/2023.
Standby Power Yes No NA NE
Page 3 of 6
DocuSign Envelope ID: 009E3475-06B1-4EBF-A56F-3E92CBDC288B
Permit: WQ0003044 Owner - Facility: Dunescape Villas Condominium Owners Association Inc
Inspection Date: 08/24/2023 Inspection Type: Compliance Evaluation Reason for Visit: Routine
Is automatically activated standby power available? 0 ❑ ❑ ❑
Is generator tested weekly by interrupting primary power source? 0 ❑ ❑ ❑
Is generator operable? 0 ❑ ❑ ❑
Does generator have adequate fuel? ❑ ❑ ❑
Comment: The generator was tested during the inspection and worked properly. It is tested on a weekly
basis. It powers the plant and the influent pump station across the street.
Treatment Barscreen Yes No NA NE
Is it free of excessive debris? 0 ❑ ❑ ❑
Is disposal of screenings in compliance? 0 ❑ ❑ ❑
Are the bars spaced properly? ❑ ❑ ❑
Is the unit in good condition? ❑ ❑ ❑
Comment:
Treatment Activated Sludge Yes No NA NE
Is the aeration mechanism operable? 0 ❑ ❑ ❑
Is the aeration basin thoroughly mixed? 0 ❑ ❑ ❑
Is the aeration equipment easily accessed? ❑ ❑ ❑
Is Dissolved Oxygen adequate? ❑ ❑ ❑
Are Settleometer results acceptable? ❑ ❑ ❑
Is activated sludge an acceptable color? 0 ❑ ❑ ❑
Comment: SBRs are monitored by DO probes. A settleometer test is done daily for process control.
Treatment Filters Yes No NA NE
Is the filter media present? ❑ ❑ ❑
Is the filter media the correct size and type? ❑ ❑ ❑
Is the air scour operational? ❑ ❑ ❑
Is the scouring acceptable? ❑ ❑ ❑
Is the clear well free of excessive solids? ❑ ❑ ❑
Is the mud well free of excessive solids and filter media? ❑ ❑ ❑
Does backwashing frequency appear adequate? 0 ❑ ❑ ❑
Comment: The two Hydrotech tertiary filters backwash automatically by the water level or programmed
time intervals.
Treatment Disinfection
Is the system working?
Do the fecal coliform results indicate proper disinfection?
Is there adequate detention time (-30 minutes)?
Is the system properly maintained?
If gas, does the cylinder storage appear safe?
Yes No NA NE
Page 4 of 6
DocuSign Envelope ID: 009E3475-06B1-4EBF-A56F-3E92CBDC288B
Permit: WQ0003044 Owner - Facility: Dunescape Villas Condominium Owners Association Inc
Inspection Date: 08/24/2023 Inspection Type: Compliance Evaluation Reason for Visit: Routine
Is the fan in the chlorine feed room and storage area operable?
❑
❑ 0 ❑
Is the chlorinator accessible?
❑
❑ 0 ❑
If tablets, are tablets present?
❑
❑ 0 ❑
Are the tablets the proper size and type?
❑
❑ 0 ❑
Is contact chamber free of sludge, solids, and growth?
❑
❑ 0 ❑
If UV, are extra UV bulbs available?
0
❑ ❑ ❑
If UV, is the UV intensity adequate?
❑
❑ ❑
# Is it a dual feed system?
❑
❑ 0 ❑
Does the Stationary Source have more than 2500 Ibs of Chlorine (CAS No. 7782-50-5)?
❑
❑ 0 ❑
If yes, then is there a Risk Management Plan on site?
❑
❑ 0 ❑
If yes, then what is the EPA twelve digit ID Number? (1000-
If yes, then when was the RMP last updated?
Comment:
Record Keeping
Yes No NA NE
Is a copy of current permit available?
0
❑ ❑ ❑
Are monitoring reports present: NDMR?
❑
❑ ❑
NDAR?
❑
❑ ❑
Are flow rates less than of permitted flow?
❑ ❑ ❑
Are flow rates less than of permitted flow?
❑ ❑ ❑
Are application rates adhered to?
❑ ❑ ❑
Is GW monitoring being conducted, if required (GW-59s submitted)?
❑ ❑ ❑
Are all samples analyzed for all required parameters?
❑ ❑ ❑
Are there any 2L GW quality violations?
❑ ❑ ❑
Is GW-59A certification form completed for facility?
❑ ❑ ❑
Is effluent sampled for same parameters as GW?
❑ ❑ ❑
Do effluent concentrations exceed GW standards?
❑ ❑ ❑
Are annual soil reports available?
❑
❑ ❑
# Are PAN records required?
❑
❑ ❑
# Did last soil report indicate a need for lime?
❑
❑ ❑
If so, has it been applied?
❑
❑ ❑
Are operational logs present?
❑ ❑ ❑
Are lab sheets available for review?
❑
❑ ❑
Do lab sheets support data reported on NDMR?
❑
❑ ❑
Do lab sheets support data reported on GW-59s?
❑
❑ ❑
Are Operational and Maintenance records present?
❑ ❑ ❑
Were Operational and Maintenance records complete?
❑ ❑ ❑
Page 5 of 6
DocuSign Envelope ID: 009E3475-06B1-4EBF-A56F-3E92CBDC288B
Permit: WQ0003044 Owner - Facility: Dunescape Villas Condominium Owners Association Inc
Inspection Date: 08/24/2023 Inspection Type: Compliance Evaluation Reason for Visit: Routine
Has permittee been free of public complaints in last 12 months? 0 ❑ ❑ ❑
Is a copy of the SOC readily available? ❑ ❑ 0 ❑
No treatment units bypassed since last inspection? ❑ ❑ 0 ❑
Comment: Operation/maintenance records were available for review and were complete.
End Use -Infiltration
Yes No NA NE
# Is the application High Rate or Low Rate?
High
Rate
Are buffers maintained?
0
❑ ❑ ❑
Are any supply wells within the CB?
❑
❑ ❑
Are any supply wells within 250' of the CB?
❑
❑ ❑
Is municipal water available in the area?
0
❑ ❑ ❑
Are GW monitoring wells required?
0
❑ ❑ ❑
Are GW monitoring wells located properly w/ respect to RB and CB?
❑
0 ❑ ❑
Are GW monitoring wells properly constructed, including screened interval?
❑
❑ ❑
Is a usable green area maintained?
❑
❑ 0 ❑
Is the disposal site acceptable?
0
❑ ❑ ❑
Is the distribution equipment acceptable?
0
❑ ❑ ❑
Is the disposal site free of ponding?
0
❑ ❑ ❑
Is the disposal site free of breakout?
0
❑ ❑ ❑
Are the disposal sites free of solids, algae, etc.?
0
❑ ❑ ❑
Do the records show that the fields are properly maintained?
0
❑ ❑ ❑
Are the disposal sites free of vegetation?
0
❑ ❑ ❑
Do any surface water features appear to be adversely impacted by GW discharge?
❑
❑ 0 ❑
No chemicals or rototiller used to eliminate vegetation, solids, algae, etc.?
0
❑ ❑ ❑
Comment: This facility was originally permitted prior to 2T rules and setbacks. MW-4,
MW-5 and MW-6 are
located within the review boundary. The location of the MWs should be re-evaluated during
the
renewal process. The 3 high -rate infiltration fields were well maintained.
Page 6 of 6