HomeMy WebLinkAbout20221617 Ver 2_Supp EZ Form_20230907SUPPLEMENT-EZ COVER PAGE
FORMS LOADED
PROJECT INFORMATION
1 lProiect Name
1 2 1 Proiect Area (ac)
3 Coastal Wetland Area (ac)
4 Surface Water Area (ac)
5 Is this project High or Low Density?
6 Does this protect use an off -site SCM?
Eastfield Crossing, Block C
117.7
0
0
High
No
COMPLIANCE WITH 02H .1003(4)
7
Width of vegetated setbacks provided (feet) 50
8
Will the vegetated setback remain vegetated? Yes
9
If BUA is proposed in the setback, does it meet NCAC 02H.1003(4)(c-d)? N/A
10
Is streambank stabilization proposed on this project? No
NUMBER AND TYPE OF SCMs:
11
Infiltration System
12
Bioretention Cell
13
Wet Pond
4
14
Stormwater Wetland
15
Permeable Pavement
16
Sand Filter
17
Rainwater Harvesting (RWH)
18
1 Green Roof
19
Level Spreader -Filter Strip (LS-FS)
20
Disconnected Impervious Surface (DIS)
21
Treatment Swale
22
Dry Pond
23
StormFilter
24
Silva Cell
25
Bayfilter
26
1 Filterra
FORMS LOADED
DESIGNER CERTIFICATION
27
Name and Title:
28
Organization:
29
Street address:
30
City, State, Zip:
31
Phone number(s):
32
1 Email:
Certification Statement:
I certify, under penalty of law that this Supplement-EZ form and all supporting information were prepared under my direction or supervision; that the
information provided in the form is, to the best of my knowledge and belief, true, accurate, and complete; and that the engineering plans,
specifications, operation and maintenance agreements and other supporting information are consistent with the information provided here.
,0A CARO
o�'F6S0 •.�'L
SEAL -
055810 _
o'•.F /Z
•.NGINES.••-O
4 S. DOS
/'11ItG����•
Signature of Designer
8/14/2023
Date
DRAINAGE AREAS
1
Is this a high density project?
Yes
2
If so, number of drainage areas/SCMs
4
3
Does this project have low density areas?
No
4
If so, number of low density drainage areas
0
5
Is all/part of this project subject to previous rule
versions?
No
FORMS LOADED
DRAINAGE AREA INFORMATION
Entire Site
1
2
3
4
4
Type of SCM
Wet Pond A2
Wet Pond A3
Wet Pond C1
Wet Pond C2
5
Total drainage area (sq ft)
4328287
1547451
245644
1698840
836352
6
Onsite drainage area (sq ft
4032031
1547451
245644
1406355
832581
7
Offsite drainage area (sq ft)
296256
292485
3771
8
Total BUA in project (sq ft
1173630
1173630 sf
9
New BUA on subdivided lots (subject to permitting)
(sq ft)
399010
399010 sf
10permitting)
New BUA not on subdivided lots (subject to
sf
2965611
1038947 sf
173780 sf
978264 sf
774620 sf
11
Offsite BUA (sq ft)
12
Breakdown of new BUA not on subdivided lots:
Parking (sq ft)
1396512
626034 sf
141195 sf
341876 sf
287407 sf
Sidewalk (sq ft
76562
55975 sf
20587 sf
Roof (sq ft)
625082
238358 sf
11998 sf
374726 sf
Roadway s ft
393867
118580 sf
261662 sf
13625 sf
Future (sq ft)
Other, please specify in the comment box
below (sq ft
473588 sf
13
New infiltrating permeable pavement on
subdivided lots (sq ft)
14
New infiltrating permeable pavement not on
Isubdivided lots (sq ft
15
Existing BUA that will remain (not subject to
permitting) (sq ft)
16
Existin BUA that is already permitted (sq ft
17
Existing BUA that will be removed (sq ft)
18
Percent BUA
78%
67%
71%
58%
140%
19
Design storm (inches)
1 in
tin
1 in
tin
1 in
20
1 Design volume of SCM cu ft
144619 cf
124446 cf
20173 cf
132873 cf
63865 cf
21
1 Calculation method for design volume
1 Simple Method
Simple Method
1 Simple Method
1 Simple Method
1 Simple Method
ADDITIONAL INFORMATION
22
Please use this space to provide any additional information about the
drainage area(s):
WET POND
1 1 2 1 3 1 4
3
Is the SCM sized to treat the SW from all surfaces at build -out?
Yes
Yes
Yes
Yes
4
Is the SCM located away from contaminated soils?
Yes
Yes
Yes
Yes
5
What are the side slopes of the SCM (H:V)?
3:1
3:1
3:1
3:1
6
Does the SCM have retaining walls, gabion walls or other engineered
side slopes?
No
No
No
No
7
Are the inlets, outlets, and receiving stream protected from erosion
(10-year storm)?
Yes
Yes
Yes
Yes
8
Is there an overflow or bypass for inflow volume in excess of the
design volume?
Yes
Yes
Yes
Yes
9
What is the method for dewatering the SCM for maintenance?
Pump (preferred)
Pump (preferred)
Pump (preferred)
Pump (preferred)
10
If applicable, will the SCM be cleaned out after construction?
Yes
Yes
Yes
Yes
11
Does the maintenance access comply with General MDC (8)?
Yes
Yes
Yes
Yes
12
Does the drainage easement comply with General MDC (9)?
Yes
Yes
Yes
Yes
13
If the SCM is on a single family lot, does (will?) the plat comply with
General MDC (10)?
N/A
N/A
N/A
N/A
14
Is there an O&M Agreement that complies with General MDC (11)?
Yes
Yes
Yes
Yes
15I
s there an O&M Plan that complies with General MDC (12)?
Yes
Yes
Yes
Yes
161
Does the SCM follow the device specific MDC?
Yes
Yes
Yes
Yes
17
Was the SCM desi ned b an NC licensed professional?
Yes
Yes
Yes
Yes
WET POND
MD[ FROM 02H _107
18
Sizing method used
SA/DA
SA/DA
HRT
HRT
19
Has a stage/storage table been provided in the calculations?
Yes
Yes
Yes
Yes
20
Elevation of the excavated main pool depth (bottom of sediment
removal) (fmsl)
163.25
164.00
161.00
162.00
21
Elevation of the main pool bottom (top of sediment removal) (fmsl)
163.75
164.50
161.50
162.50
221
Elevation of the bottom of the vegetated shelf (fmsl)
166.75
169.50
165.00
165.50
23
Elevation of the permanent pool (fmsl)
167.25
170.00
164.50
1166.75
24
Elevation of the top of the vegetated shelf (fmsl)
167.75
170.50
166.00
166.50
25
Elevation of the temporary pool (fmsl)
167.81
170.82
165.50
168.00
26
Surface area of the main permanent pool (square feet)
208261
22883
129349
48195
27
Volume of the main permanent pool (cubic feet)
520306 cf
69893 cf
363619 cf
148003 cf
28
Average depth of the main pool (feet)
3.00 ft
4.00 ft
2.81 ft
3.07 ft
29
Average depth equation used
Equation 3
Equation 3
Equation 2
Equation 2
301
If using equation 3, main pool perimeter (feet)
4334.0 ft
731.0 ft
31
If using equation 3, width of submerged veg. shelf (feet)
3.0 ft
3.0 ft
32
Volume of the forebay (cubic feet)
73635 cf
82821 cf
82981 cf
162314 cf
33
Is this 15-20% of the volume in the main pool?
Yes
Yes
Yes
Yes
34
Clean -out depth for forebay (inches)
6 in
6 in
6 in
6 in
35
Design volume of SCM (cu ft)
869331 cf
130318 cf
132873 cf
63865 cf
36
Is the outlet an orifice or a weir?
Orifice
Orifice
Orifice
Orifice
371
If orifice, orifice diameter (inches)
8 in
2 in
4 in
3 in
38
If weir, weir height (inches)
39
If weir, weir length (inches)
40
Drawdown time for the temporary pool (days)
3
4.5
3.35
2.74
41
Are the inlet(s) and outlet located in a manner that avoids short-
circuiting?
Yes
Yes
Yes
Yes
42
Are berms or baffles provided to improve the flow path?
No
No
No
No
431
Depth of forebay at entrance (inches)
164 in
165 in
48 in
42 in
441
Depth of forebay at exit (inches)
164 in
165 in
48 in
42 in
45
Does water flow out of the forebay in a non -erosive manner?
Yes
Yes
Yes
Yes
46
Width of the vegetated shelf (feet)
6 ft
6 ft
6 ft
6 ft
47
Slope of vegetated shelf (H:V)
6:1
6:1
6:1
6:1
48
Does the orifice drawdown from below the top surface of the
permanent pool?
Yes
Yes
Yes
Yes
49
Does the pond minimize impacts to the receiving channel from the 1-
yr, 24-hr storm?
Yes
Yes
Yes
Yes
50
Are fountains proposed? (If Y, please provide documentation that
MDC(9) is met.)
No
No
No
No
51
Is a trash rack or other device provided to protect the outlet system?
Yes
Yes
Yes
Yes
52
Are the dam and embankment planted in non -clumping turf grass?
Yes
Yes
Yes
Yes
53
Species of turf that will be used on the dam and embankment
Clean Crop Seed
Clean Crop Seed
Clean Crop Seed
Clean Crop Seed
54
Hasa planting plan been provided for the vegetated shelf?
Yes
Yes
Yes
Yes
IITIONAL INFORMATION
55 Please use this space to provide any additional information about the
wet Dond(s):
Wet Pond 3 12:52 PM 8/14/2023