HomeMy WebLinkAboutWQ0021204_Monitoring - 07-2023_20230825Monitoring Report Submittal Permit Number#* WQ0021204 Name of Facility:* North Chatham Fire Dept Month:* July Report Information Type * NDMR, NDAR-1, NDAR-2, NDMLR Confirmation Email Address: * Biowater@aol.com Name of Submitter: * Randall Jarrell Signature: Year:* 2023 Upload Document* NCVFD NDMR 7-23.pdf PDF Only 2.92 M B Please upload one PDF containing all applicable monitoring reports (i.e., NDMR, NDAR-1, NDAR-2, NDMLR, GW-59). Date of submittal: 8/25/2023 This will be filled in automatically Initial Review Reviewer: Wanda.Gerald Is the project number correct?* WQ0021204 Is the monitoring report accepted?* Yes No Regional Office* Raleigh Reviewer: _anonymous Review Date: 9/8/2023 FORM: NDMR 03-12 NON -DISCHARGE MONITORING REPORT (NDMR) Page t of 5 Permit No.: WQ0021204 Facility Name: North Chatham Vol. Fire Dept. County: Chatham Month: July Year: 2023 PPI: Flow Measuring Point: ❑ Influent ❑ Effluent ❑ No Flow generated Parameter Monitoring Point: Li Influent ❑ Effluent ❑ Groundwater Lowering ❑ Surface water Parameter Code 1, 50050 00400 60060 00310 00610 00530 31616 00620 00600 00625 00665 �. y Q_ O a+ Cn O O _ 2 is m O C w :O O U Ln ccm E O Q O vi y C a m E U O 0 U y ty Z c y ,��, O Z r 'a c y N O) o o Z 1 _ l0 t .. t a 24-hr hrs GPD su mg/L mg/L mg/L mg/L #1100 mL mg/L mg/L mg/L mg/L 1 61 2 61 3 14:10 0.5 61 4 79 5 79 6 79 7 79 8 79 9 79 10 13:40 0.5 79 11 09:55 0.17 149 0.62 0.61 4.5 1.3 5.9 690 5.2 8.2 2.9 2 12 149 131 149 14 149 15 149 16 17:05 0.5 149 17 55 18 55 191 55 20 55 21 55 22 55 23 55 24 14:10 0.5 55 251 67 26 67 27 67 28 67 29 67 30 67 311 13:20 1 0.5 67 Average: 82 0.61 4.50 1.30 5.90 690.00 5.20 8.20 2.90 2.00 Daily Maximum: 149 0.62 0.61 4.50 1.30 5.90 690.00 5.20 8.20 2.90 2.00 Daily Minimum: 55 0.62 0.61 4.50 1.30 5.90 690.00 5.20 8.20 2.90 2.00 Sampling Type: Monthly Avg. Limit: Daily Limit: Sample Frequency: FORM: NDMR 03-12 NON -DISCHARGE MONITORING REPORT (NDMR) Page z of Sampling Person(s) Name: Randall Jarrell Name Certified Laboratories Name: Eurofins (591) Name: Wastewater Management, L.L.C. (5038) Does all monitoring data and sampling frequencies meet the requirements in Attachment A of your permit? ❑ Compliant ❑ Non -Compliant If the facility is non -compliant, please explain in the space below the reason(s) the facility was not in compliance. Provide in your explanation the date(s) of the non-compliance and describe the corrective action(s) taken. Attach additional sheets if necessary. Operator in Responsible Charge (ORC) Certification Permittee Certification ORC: Randall Jarrell Permittee: North Chatham Vol. Fire Dept. (Mark Rigsbee) Certification No.: 7937, 23925 Signing Official: Randall Jarrell Grade: WW4, SI Phone Number: 919-210-2500 Signing Official's Title: ORC Has the ORC changed since the previous NDMR? ❑ yes 0 No 9 P Phone Number: 919-210-2500 Permit Expiration: 5/31/2027 Signature Date Signature Date By this signature, I certify that this report is accurrate and complete to the best of my knowledge. I certify, under penalty of law, that this document and all attachments were prepared under my direction or supervision in accordance with a system designed to assure that all qualified personnel properly gathered and evaluated the information submitted. Based on my inquiry of the person or persons who manage the system, or those persons directly responsible for gathering the information, the information submitted is, to the best of my knowledge and belief, true, accurate, and complete. I am aware that there are significant penalties for submitting false information, including the possibility of fines and imprisonment for knowing violations. Mail Original and Two Copies to: Division of Water Resources Information Processing Unit 1617 Mail Service Center Raleigh, North Carolina 27699-1617 FORM: NDAR-1 10-13 NON -DISCHARGE APPLICATION REPORT (NDAR-1) Page 3 of 5' Permit No.: 1111 14 Facility Name: North Chatham Vol.Fire Dept. . • •irrigationoccur Field Nam at this facility? Area (acres):III 1 Area (acres): YES NO IN �. '.Annual Rate (in): JOIN mmml m ___ __ -_-- MW Monthly•.• • Month12 •. • Total FORM: NDAR-1 10-13 NON -DISCHARGE APPLICATION REPORT (NDAR-1) Page 11 of S- Did the application rates exceed the limits in Attachment B of your permit? Were adequate measures taken to prevent effluent ponding in or runoff from the sites? Was a suitable vegetative cover maintained on all sites as specified in your permit? Were all setbacks listed in your permit maintained for every application to each permitted site? Were all freeboards maintained in accordance with the specified freeboard heights in your permit? ❑ Compliant ❑ Non -Compliant ❑ Compliant ❑ Non -Compliant ❑ Compliant ❑ Non -Compliant 0 Compliant ❑ Non -Compliant 21 Compliant ❑ Non -Compliant If the facility is non -compliant, please explain in the space below the reason(s) the facility was not in compliance. Provide in your explanation the date(s) of the non-compliance and describe the corrective action(s) taken. Attach additional sheets if necessary. Operator in Responsible Charge (ORC) Certification Permittee Certification ORC: Randall Jarrell Permittee: North Chatham Vol. Fire Dept. (Mark Rigsbee) Certification No.: 7937, 23925 Signing Official: Randall Jarrell Grade: WW4, SI Phone Number: 919-210-2500 Signing Official's Title: ORC Has the ORC changed since the previous NDAR-1? ❑ Yes No Phone Number: 919-210-2500 Permit Exp.: 5/31/27 14__/1 �? ) I s- k -3 X, P, P_ I 2-6� Signature Date / Signature Date By this signature, I certify that this report is accurrate and complete to the best of my knowledge. I certify, under penalty of law, that this document and all attachments were prepared under my direction or supervision in accordance with a system designed to assure that all qualified personnel properly gathered and evaluated the information submitted. Based on my inquiry of the person or persons who manage the system, or those persons directly responsible for gathering the information, the information submitted is, to the best of my knowledge and belief, true, accurate, and complete. I am aware that there are significant penalties for submitting false information, including the possibility of fines and imprisonment for knowing violations. Mail Original and Two Copies to: Division of Water Resources Information Processing Unit 1617 Mail Service Center Raleigh, North Carolina 27699-1617 NCVFD 12 Month Rolling Total Application In Inches 2023 2023 2023 2023 2023 2023 2023 2022 2021 2022 2022 2022 2023 Field Jan Feb March April May June j_Ul August Sept Oct Nov Dec Total 1 0.7 0.51 0.56 0.56 0.61 0.65 0.94 0 0 0.73 0.7 0.56 6.52 2 0.53 0.39 0.42 0.42 0.46 0.49 0.7 0 0 0.55 0.53 0.42 4.91