Loading...
HomeMy WebLinkAboutNC0003417_HF LEE-WSP TOPO-SHEET 2_20150805d 3 1SMB ONE STORY METAL BUILDING 1SMBB ONE STORY BLOCK BUILDING 2SMB TWO STORY METAL BUILDING 2' INTERVAL CONTOURS OBSCURED AREAS* 2' INTERVAL CONTOURS OPEN AREAS AERIAL MAPPING LIMIT ° AERIAL MAPPING LIMIT - ASH AREA PREVIOUSLY MAPPED ASH AREA: 175.25 ACRES APV 0 AIR PRESSURE VALVE TOTAL MAPPED AREA: 1,138.75 ACRES (INCLUDING ASH AREA) BFP BACK FLOW PREVENTER BIRD BIRD HOUSE - NESTING POLE BT BLOCK AND TACKLE W BLUE PIPES - VERTICAL GENERAL NOTES o_ CABLE BOX 1. BASIS OF BEARINGS: NC GRID NAD83/2011. 0 CAM -) CAMERA POLE W O CY CANOPY 2. ELEVATIONS ARE BASED ON NAVD88. CO • CLEAN OUT 3. THIS MAP IS NOT A BOUNDARY SURVEY, PROPERTY LINES SHOWN HEREON PER WAYNE COUNTY GIS AND z II ARE FOR REFERENCE ONLY. EC CONCRETE SLAB - PAD A CONTROL POINT 4. THE PLANIMETRIC LOCATION ON THIS MAP IS BASED ON PHOTOGRAMMETRIC MAPPING OF IMAGERY °- •� COLLECTED ON APRIL 17, 2014. THE IMAGERY CAPTURED IS SUITABLE TO CREATE 1"=100' SCALE - CMP CORRUGATED METAL PIPE MAPPING AND CONTOURS AT AN INTERVAL OF 2', AND MEETS THE NATIONAL MAP ACCURACY STANDARDS CPP CORRUGATED PLASTIC PIPE FOR 1"=100' SCALE MAPPING. DATA PROVIDED WHERE CLEAR AND VISIBLE ON THE IMAGERY IS WITHIN 2' OF ITS TRUE POSITION. DRAIN LINE DRAINAGE CENTERLINE 5. NO UNDERCROUND IJTIJ ITIFC, I -dA \/F RFFN LOCATED OR NAn` -DPFF) r�)R TI-111- fDR JF� � THE OD DRAINAGE MANHOLE LOCATION OF ANY AND ALL UTILITIES SHOWN HEREON WHETHER PUBLIC OR PRIVATE, IS BASED ON °o- PHOTOGRAMMETRIC MAPPING AND IS APPROXIMATE ONLY. IT IS THE CONTRACTOR'S RESPONSIBILITY TO ® DROP INLET DRAIN VERIFY LOCATION PRIOR TO COMMENCEMENT OF ANY CONSTRUCTION. WSP CANNOT ASSUME RESPONSIBILITY FOR MISIDENTIFICATION OR OMISSION OF UNDERGROUND UTILITIES. DIP DUCTILE IRON PIPE EP G( ELECTRIC PUMP 6. DASHED CONTOURS AND ESTIMATED SPOT ELEVATIONS SHOWN IN OBSCURED AREAS ARE COMPILED FROM LIMITED PHOTOGRAMMETIC DATA DUE TO LEAF ON CONDITIONS DURING THE APRIL 17TH FLIGHT. O ELECTRIC MANHOLE INFORMATION SHOWN IN OBSCURED AREAS IS FOR REFERENCE ONLY. ES ELECTRIC SERVICE BOX 7. CONTOURS SHOWN UNDER WATER PER BATHYMETRIC SURVEYS CONDUCTED BY WSP IN AUGUST 2013. - X- X- X- X -X -X- FENCE LINE - CHAIN LINK WATER ELEVATION (W.E.) SHOWN HEREON IS FROM APRIL 17, 2014. FENCE LINE - VINYL FP (D FLAG POLE 8. FLOOD LINES SHOWN HEREON ARE FOR REFERENCE ONLY, PER WWW.FRIS.NC.GOV. FA FLAME ARRESTOR 9. PORTIONS OF THE MAPPED AREA ARE WITHIN A FLOOD HAZARD AREA ACCORDING TO FLOOD INSURANCE FO o FIBER OPTIC LINE MARKER RATE MAPS: 3720256800J PANEL 2568 LAST REVISED 12/02/05 o FIRE FIRE BOX 3720258800J PANEL 2588 LAST REVISED 12/02/05 CL FIRE HYDRANT - FLOOD LINE (SEE NOTE #8) 10. SWITCHYARD AND / OR SUBSTATION INFORMATION SHOWN HEREON INSIDE THE FENCE LINE IS FROM PHOTOGRAMMETRIC MAPPING ONLY AND NO FIELD VERIFICATION HAS BEEN PERFORMED. GM © GAS LINE MARKER GAS® GAS VALVE 11. ALL DISTANCES ARE HORIZONTAL GROUND DISTANCES IN U.S. SURVEY FEET UNLESS OTHERWISE NOTED. GRAVEL /DIRT PATH 12. THE AREA SHOWN HEREON WAS COMPUTED USING THE COORDINATE COMPUTATION METHOD. v)'..) °O GH GUARD HOUSE Z �o GUARD RAIL 13. LINES NOT SURVEYED ARE SHOWN AS BROKEN LINES FROM INFORMATION REFERENCED ON THE FACE OF a z THIS PLAT. m !: GUY WIRE � o p IV O INDICATOR VALVE -WATER 14. PROPERTY SUBJECT TO ALL EASEMENTS AND RESTRICTIONS OF RECORD. N " N v az IRR IRRIGATION CONTROL 15. INFORMATION SHOWN ON PRIVATE PROPERTY IS FOR REFERENCE ONLY. m KEYPAD - GATE CALL BOX LIGHT POLE MB MAIL BOX QO MANHOLE - UNKNOWN Lu MANHOLE - SANITARY SEWER LLJ MW O MONITOR WELL > W OBSCURED AREAS* ? o J AERIAL TARGET POINTS d &S OIL & WATER SEPARATOR U) OVERHEAD UTILITIES # NORTHING EASTING ELEV. O PATH - TRAIL 1 598,409.60 2,264,347.01 90.68 = U PAVED SURFACE 2 598,897.03 2,267,451.92 87.56 d } ©© POOL - INGROUND - ABOVE GROUND 3 599,896.94 2,281,199.20 120.10 < (� 4 590,039.54 2,271,898.12 85.69 � Posr UJ 5 594,684.93 2,271,470.44 81.18 Q Z - - PROPERTY LINE (GIS) n- 6 598,753.65 2,274,404.66 103.37 LLI PROPERTY LINE (GIS -DUKE ENERGY) 7 593,957.70 2,263,340.68 75.84 Of- LLI PWB PORTABLE WATER TANK 8 590,032.61 2,267466.77 73.64 J J RCP REINFORCED CONCRETE PIPE Q LL Q SIGN Lu • SPOT ELEVATION CONTROL POINTS Q • SPOT ELEVATION ESTIMATED OBSCURED AREAS # NORTHING FASTING ELEV. m STORM DRAIN 2 597,059.60 2,276,431.67 89.11 SUMP SUMP PUMP PANEL 3 596,350.04 2,274,867.67 89.09 O TANK 4 594,050.19 2,266,363.36 79.01 TELEPHONE LINE MARKER 5 593,721.62 2,266,853.07 81.34 TELEPHONE MANHOLE TELEPHONE PEDESTAL TSTA TEST STATION TF TRANSFORMER TR TRAILER - MOBILE JOB SITE OFFICE TREE / BRUSH LINE X UNIDENTIFIED UTILITIES / STRUCTURES / OBJECTS 0 ¢ � UTILITY POLE / TRANSMISSION POLE / TRANS. TOWER TT'' N Z O ® VAULT Cn VAG VAULT ABOVE GROUND 0w _ V • VALVE PVC VERTICAL PVC r7/ / 'Z�11'Z WATER ❑W WATER METER O WATER MANHOLE WV g WATER VALVE WVT [WT-1 WATER VAULT WWT WELL WATER TANK ilh WET AREA Q YELLOW PAINTED MANHOLE * SEE GENERAL NOTES