HomeMy WebLinkAboutWQCS00350_Renewal (Application)_20230905ROY COOPER
Governor
ELIZABETH S. BISER
Secretary
RICHARD E. ROGERS, JR.
Director
T Barrow, City Engineer
City of King
229 S State St
King, NC 27021
Subject: Permit Renewal
Application No. WQCS00350
King Collection System
Stokes County
Dear Permittee:
NORTH CAROLINA
Environmental Quality
September 05, 2023
The Water Quality Permitting Section acknowledges the September 5, 2023 receipt of your permit renewal application
and supporting documentation. Your application will be assigned to a permit writer within the Section's Non -discharge
permitting branch. Per G.S. 150B-3 your current permit does not expire until permit decision on the application is made.
Continuation of the current permit is contingent on timely and sufficient application for renewal of the current permit. The
permit writer will contact you if additional information is required to complete your permit renewal. Please respond in a
timely manner to requests for additional information necessary to allow a complete review of the application and renewal
of the permit.
Information regarding the status of your renewal application can be found online using the Department of Environmental
Quality's Environmental Application Tracker at:
https•//deq nc gov/permits-regulations/permit-guidance/environmental-application-tracker
If you have any additional questions about the permit, please contact the primary reviewer of the application using the
links available within the Application Tracker.
ec: WQPS Laserfiche File w/application
jgLD_EQ__
Sincerely,
Cynthia Demery
Administrative Assistant
Water Quality Permitting Section
North Carolina Department of Environmental Quality I Division of Water Resources
Winston-Salem Regional OffIce 1 450 West Hanes MITI Road. State 300 1 Winston-Salem, North Carolina 27105
336.776.9800
CITY OF KING
Jack Warren, Mayor
T. Scott Barrow, City Manager
Benjamin Marion, City Engineer
P.O. Drawer 1132
King, NC 27021-1132
RECEIVED
SEP 0 5 2023
NCDEQ/DWR/NPDES
229 S. Main Street
Telephone (336) 985-1100
Fax (336) 983-4675
August 30, 2023 ==
System Wide Collection Permit Renewal for Permit No. WQCS00350 for the City of King
Please find the attached following items:
1. Application Form CSA 04-16 z t
2. High Priority Line List `
3. Annual Wastewater Distribution and Wastewater Maintenance Budgets for FY 23-24
4. Capital Improvement Plan (CIP)
5. Pump Station Contingency Plan (includes Pump Failure Contingency Plan, Sewer Pumping
Station Contingency Plan, Pumping Station List and Wastewater Emergency Spill
Response Plan) x�
6. Collection System Map
7. Items 1-6 on a USB flash drive to provide digital copies of everything provided.
Should you have any questions of concerns with material submitted in this permit renewal, please
contact The City of King Engineering Department at 336-983-8265.
Sincerely,
9
BeFllamCS. Marion
City Engineer Intern
Division of Water Resources
State of North Carolina
Department of Environmental Quality
Division of Water Resources
15A NCAC 02T .0400 — SYSTEM -WIDE WASTEWATER COLLECTION SYSTEMS
INSTRUCTIONS FOR FORM CSA 04-16 & SUPPORTING DOCUMENTATION
Documents shall be prepared in accordance with 15A NCAC 02T .0100, 15A NCAC 02T .0400, and all relevant
Division Policies. Failure to submit all required items will necessitate additional processing and review time.
For more information, visit the System -wide Collection System Permitting website:
General — When submitting an application to the Municipal Permitting Unit, please use the following instructions as a
checklist in order to ensure all required items are submitted. Adherence to these instructions and checking the provided
boxes will help produce a quicker review time and reduce the amount of requested additional information.
The Applicant shall submit one orisinal and one copy of the application and supporting documentation.
The copy may be submitted in digital format.
A. Cover Letter
g Submit a cover letter listing all items and attachments included in the permit application package
B. No Application Fee Required
➢ No application fee is necessary. The permittee will be billed an annual fee upon issuance of the permit
➢ The appropriate annual fee for systemwide wastewater collection system permits may be found at:
➢ Annual Non -Discharge Fees
C. System -Wide Wastewater Collection System (FORM: CSA 04-16) Application:
® Submit the completed and appropriately executed System -wide Wastewater Collection System (FORM: CSA 04-
16) application. Any unauthorized content changes to this form shall result in the application package being
returned. If necessary for clarity or due to space restrictions, attachments to the application may be made, as long
as the attachments are numbered to correspond to the section and item to which they refer.
❑ If the Applicant Type in Section I.3 is a Privately -Owned Public Utility, provide the Certificate of Public
Convenience and Necessity (CPCN) from the North Carolina Utilities Commission demonstrating the Applicant is
authorized to hold the utility franchise for the area to be served by the wastewater collection system, or
❑ Provide a letter from the North Carolina Utilities Commission's Water and Sewer Division Public Staff stating an
application for a franchise has been received and that the service area is contiguous to an existing franchised area
or that franchise approval is expected.
❑ If the Applicant Type in Section I.3 is a corporation or company, provide documentation if it is registered for
business with the North Carolina Secretary of State.
D. General Information:
➢ The Authorized signing official listed in Section I.4 should match with that of the Applicant certification page in
accordance with 15A NCAC 02T .0106(b). Per 15A NCAC 02T .0106(c), an alternate person may be designated
as the signing official if a delegation letter is provided from a person who meets the criteria in 15A NCAC 02T
.0106(b).
➢ NOTE - Public Works Directors are not authorized to sign this permit application, according to the rule,
unless they are formally delegated.
INSTRUCTIONS FOR APPLICATION CSA 04-16 & SUPPORTING DOCUMENTATION Page 1 of 5
E. Summary of Attachments Required:
®
Instruction A: Cover Letter
®
Instruction C: Application
❑
Instruction C: Ownership Documentation (i.e. CPCN) (If necessary)
❑
Instruction D: Delegation Letter (If necessary for signing official)
®
Section IV.3 Pump Station List
®
Section IVA High Priority Lines List
®
Section VA Annual Budget for Collection System (Updated and Approved)
®
Section V.6 Capital Improvement Plan (Updated and Approved)
®
Section VI.2 Response Action Plan
®
Section VIA Contingency Plan
®
Section VI.6 Comprehensive Collection System Map
❑
Section VH Note Any Potential Compliance Issues
THE COMPLETED APPLICATION PACKAGE, INCLDING ALL SUPPORTING INFORMATION AND
MATERIALS, SHOULD BE SENT TO:
NCDEQ-DWR
Water Quality Permitting Section
MUNICIPAL PERMITTING UNIT
By U.S. Postal Service: By Courier/Special Delivery:
1617 MAIL SERVICE CENTER 512 N. SALISBURY ST. Suite 925
RALEIGH, NORTH CAROLINA 27699-1617 RALEIGH, NORTH CAROLINA 27604
TELEPHONE NUMBER: (919) 707-3601 TELEPHONE NUMBER: (919) 707-3601
INSTRUCTIONS FOR APPLICATION CSA 04-16 & SUPPORTING DOCUMENTATION Page 2 of 5
I. APPLICANT INFORMATION:
1. Applicant's name (Municipality, Public Utility, etc): City of King
2. Facility Information: Name: City of King Collection System Permit No.: WQCS00350
3. Applicant type: ® Municipal ❑ State ❑ Privately -Owned Public Utility
❑ County ❑ Other:
4. Signature authority's name: Benjamin S. Marion per 15A NCAC 02T .0106(b)
Title: City Engineer Intern
5. Applicant's mailing address: PO Box 1132
City: King State: NC Zip: 27021-
6. Applicant's contact information:
Phone number: 336 983-8265 Fax number: Q36) 983-4675 Email address: bmarion(&ci.king nc.us
H. CONTACT/CONSULTANT INFORMATION:
1. Contact Name: Benjamin S. Marion
2. Title/Affiliation: City Engineer Intern for Ci of f King
3. Contact's mailing address: PO Box 1132
4. City: King State: NC Zip: 27021
5. Contact's information:
Phone number: 336 983-8265 Fax number: (336) 9834675 Email address: bmarionAci.king nc.us
III. GENERAL REQUIREMENTS:
1. New Permit or Premit Renewal? ❑ New ® Renewal
2. County System is located in: Stokes/Fors tthh County
3. Owner & Name of Wastewater Treatment Facility(ies) receiving wastewater from this collection system:
Owner(s) & Name(s): City of Winston Salem Lower Muddy Creek WWTP
4. WWTF Permit Number(s): NCO050342
5. What is the wastewater type? 100 % Domestic or % Industrial (See 15A NCAC 02T .0103(20))
II
y Is there a Pretreatment Program in effect? ❑ Yes or ® No
6. Wastewater flow:.575 MGD (Current average flow of wastewater generated by collection system)
7. Combined permitted flow of all treatment plants:.97 MGD (this is our contribution to City of Winston Salem's Treatment
Plant)
8. Explain how the wastewater flow was determined: ® 15A NCAC 02T .0114 or ® Representative Data (from flow meter at
last pump station in our system before enter Winston Salem's collection system)
9. Population served by the collection system: &7590
APPLICATION CSA 04-16 Page 3 of 5
IV. COLLECTION SYSTEM INFORMATION:
1. Line Lengths for Collection System:
Sewer Line Description
Length
Gravity Sewer
38
miles
Force Main
7
miles
Vacuum Sewer
0
miles
Pressure Sewer
0
miles
2. Pump Stations for Collection System:
Pump Station Type
Number
Simplex Pump Stations(Serving Single Building)
0
Simplex Pump Stations(Serving Multiple Buildings)
0
Duplex Pump Stations
12
3. Submit a list of all major (i.e. not simplex pump station serving a single family home) pump stations. Include the following
information:
➢ Pump Station Name
➢ Physical Location
➢ Alarm Type (i.e. audible, visual, telemetry, SCADA)
➢ Pump Reliability (Can convey peak hourly wastewater flow with largest single pump out of service)
➢ Reliability Source (permanent/portable generator, portable pumps)
➢ Capacity of Station (Pump Station Capacity in GPM)
4. Submit a list of all high priority lines according per 15A NCAC 02T .0402(2) known to exist in the collection system. Head
the list with "Attachment A for Condition V(4)" and include the system name.
➢ Use the same line identification regularly used by the applicant
➢ Indicate type of high priority line (i.e. aerial), material and general location
V. COLLECTION SYSTEM ADMINISTRATION:
1. Provide a brief description of the organizational structure that is responsible for management, operation and maintenance of
the collection system.
Wastewater Collection Operators report to Backup ORC (Lemmie Todd Hill), Backup ORC Reports to ORC (Willam Todd
Alley) ORC Reports to Public Utilities Superintendent (Robert Pettitt) who Reports to City Engineer (Benjamin Marion),
who reports to City Manager (T. Scott Barrow) who reports to City Council.
2. Indicate the current designated collection system operators for the collection system per 15A NCAC 08G.0201
Main ORC Name: William Todd Alley
Certification Number: 21708
Back -Up ORC Name: Lemmie Todd Hill
Certification Number: 21718
See the "WQCS Contacts and ORC Report" for a current listing of the ORC(s) the Division has on file for WQCS permit
3. Approximate annual budget for collection system only: $ 5,671,935.00
4. Submit a copy of your current annual budget.
5. Approximate capital improvement budge for the collection system only: $ 3,795,000
6. Submit a copy of your current capital improvement plan.
7. Is this collection system currently a satellite system ❑ Yes or ® No
APPLICATION CSA 04-16 Page 4 of 5
8. Do any satellite systems discharge to this collection system ❑ Yes or ❑ No (If yes complete table below)
Satellite System Contact Information(Name, Address Phone Number
Complete for Satellite Systems that have a flow or capacity greater than 200,000 GPD (Average daily flow)
9. List any agreements or ordinances currently in place to address flows from satellite systems:
VI. COLLECTION SYSTEM COMPLIANCE:
1. Is a Response Action Plan currently in place ® Yes or ❑ No
2. If Yes, submit a copy of the Response Action Plan or see table 6 below.
3. Is a pump station contingency plan currently in place? ® Yes or ❑ No
4. If Yes, submit a copy of the pump station contingency plan or see table 6 below.
5. Is a comprehensive collection system map currently in place? ® Yes or ❑ No
6. Submit a submit a copy of the collection system map (CD or hardcopy) or indicate a schedule for completion
7. Thoroughly read and review the System -Wide Collection System Permit Conditions. Typically compliance schedules
are only offered to NEW permit applicants and NOT permit renewals. Any compliance dates must be included within
the permit prior to issuance or the permit holder will be found in violation upon inspection.
Permit Condition
Current
Compliance?
If no, Indicate a
Compliance
Date
Typical
Compliance
Schedule
I(4) — Grease ordinance with legal authority to inspectlenforce
® Yes ❑ No
12 — 18 mo.
I(5) — Grease inspection and enforcement program
® Yes ❑ No
12 — 18 mo.
I(6) — Three to Live year current Capital Improvement Plan.
® Yes ❑ No
12 — 18 mo.
I(8) — Pump station contingency plan
® Yes ❑ No
3 mo.
I(9) — Pump station identification signs.
® Yes ❑ No
3 mo.
I(11) — Functional and conspicuous audible and visual alarms.
® Yes ❑ No
3 — 6 mo.
II(5) — Spare pumps for any station where one pump cannot
handle peak flows alone (in a duplex station, the 2°d pump is
the spare if pump reliability is met).
® Yes ❑ No
6 — 9 mo.
II(7) — Accessible right-of-ways and easements.
® Yes ❑ No
6 — 12 mo.
II(9) — Response action plan with Items 9 (a — h).
® Yes ❑ No
3 mo.
HI(3) — Comprehensive collection system map
® Yes ❑ No
10% per year
For conditions not listed, compliance dates are not typically offered. List any permit conditions that may be difficult for the
applicant to meet (attach clarification if needed):
APPLICATION CSA 04-16 Page 5 of 5
VII. APPLICANT'S CERTIFICATION per 15A NCAC 02T .0106(b):
I, Benjamin S. Marion
(Signature Authority's Name & Title from Item I.4)
attest that this application for
The City of King
(Facility name from Item I.1)
has been reviewed by me and is accurate and complete to the best of my knowledge. I understand that if all required parts of this
application are not completed and that if all required supporting information and attachments are not included, this application package
will be returned to me as incomplete.
Note: In accordance with NC General Statutes 143-215.6A and 143-215.6B, any person who knowingly makes any false statement,
representation, or certification in any application shall be guilty of a Class 2 misdemeanor which may include a fine not to exceed
$10,000 as well as So penalties up to $25,000 per violation. /
Signature:4 Date: " 03
rov, U V
APPLICATION CSA 04-16 Page 6 of 5
Pump Station list
PumpStation Name
Alternate Name
Location
Near b TributaryCapacity
y
allons
Pump Rate
m
Max PumpRate
(gpm)
R of
Pum s
Pump
HP
PumpManufactor
Pump Info
p
Backup Power Info
p
Communitcatlons Info
Farm Pump Station
Farm Pump Station
229 Rolling Green Lane
Crooked Run Creek
30771
21 W
6300
3
125
Fairbanks Morris
3 on Alternate Running Cycles
30OKW permanent
SCADA, Cellular, Verizon
Littlebrook East
Lower Littlebrook
$99 Lltdebrook on-
Crooked Run Creek
939
60
120
2
5
ABS
2 on Alternate Running Cylces
50KW Portable
None
Utdebrook West
Upper Uttlebrook
101 Uttlebrook Drive
rooked Run Creek & Lilly Lake
1033
60
120
2
5
ABS
2 on Alternate Running Cylces
50KW Portable
None
Trinity Church Road
Trinity Chuuch
249 Trinity Church Road
None
1935
45
90
2
5
ASS
2 on Alternate Running Cylces
5oKW Portable
None
GoffRoad
Danbury Creek
504 Goff Road
Danbury Creek
9959
415
1245
3
75
Fairbanks Morris
3 on Alternate Running Cycles
20DKW permanment
SCADA, Cellular, Verizon
Spainhour Road
Muddy Creek Pump Station
801 Spainhour Road
Muddy Creek
3699
800
law
2
45
Empo
2 on Alternate Running Cylces
20OKW permanment
SCADA, Cellular, Vertzon
Mode lds Pump Statlon
Allegacy Pump Station
109 Carmel Drive
None
3382
40
g0
2
7.5
ABS
2 on Alternate Running Cylces
20DKW permanment
SCADA, Cellular, Verizon
Kensington Pump Station
Billy Kreeger Pump Station
225 Greystone Drive
None
2748
60
120
2
10
ABS
2 on Alternate Running Cylces
50KW Portable
None
Sunset Drive
Sunset
125 Sunset Drive
None
1033
25
SO
2
SABS
2 on Ahemate Running oAces
50KW Portable
None
Woodcreek Pump
Woodcreek
125 Kiser Drive
Muddy Creek
6200
110
600
4
25
Meyers
2 groups of 2 pumps on Alternate Running Cylces
20DKW permanent
SCADA, Cellular, Verizon
Mountain Shadows
Mountain Shados
104 Mountain Shadow lane
None
2495
60
120
2
7.5
Meyers
2 on ANemate Running Mces
50KW Portable
None
Callow. Court
Callow.
126 Callow. Court
None
1248
60
120
2
2
Meyers
ton Alternate Runnln C Ices
SOKW Portable
None
Citv of King High Prioritv Sewer Line List
Line Name
Line Location
Line Length (miles)
Farm Pump Station Force Main
Farm PS to Doral Drive
2.21
Kingsway Outfall
Kingsway Drive to Farm Pump Station
1.27
Pilot Bluff Outfall
Pilot Bluff Subdivision to Winfield Drive
0.37
Jefferson Woods Outfall
Jefferson Woods Subdivision to Muddy Creek PS
0.17
Wastewater Distribution
Expenditures Detailed
2023-24 Annual Budget
Actual
Estimated
Department
Manager
Board
Classification
GL Account #
Actual
Budgeted
Expenditures
Expenditures
Request
Recommend
Approved
FY 21-22
FY 22-23
1/31/2023
FY 22-23
FY 22-23
FY 22-23
FY 22-23
Operating and Maintenance
61-6700-504000
16,067
18,000
2,419
16,000
20,000
18,000
18,000
Professional Services
Telephone
61-6700-511000
2,706
2,300
1,244
2,057
2,300
2,300
2,300
Utilities
61-6700-513100
58,990
63,983
34,228
56,988
68,000
68,000
68,000
Equipment Repairs/Maintenance
61-6700-516200
285
2,500
0
1,000
2,500
2,500
2,500
Departmental Supplies/Materials
61-6700-533000
0
5,000
1,505
5,000
5,000
5,000
5,000
Contracted Services
61-6700-545000
1,462,163
1,639,863
822,079
1,803,620
1,639,863
1,558,138
1,558,138
Miscellaneous
61-6700-557000
50
100
0
0
Subtotal Operating
75
1,884,664
1,737,663,
Other
61-6700-573100
0
0
0
0
0
Capital -General Improvements
Capital -Equipment
61-6700-574100
0
0
0
0
0
u tota ter
otas
5
, 5,
Wastewater Maintenance
Expenditures Detailed
2023-24 Annual Budget
Actual
Estimated
Department
Manager
oard
Classification
GL Account #
Actual
Budgeted
Expenditures
Expenditures
Request
Recommend
Approved
FY 21-22
FY 22-23
1/31/2023
FY 22-23
FY 23-24
FY 23-24
FY 23-24
Personnel
61-6800-502000
$76,545
$78,815
$56,007
$90,222
$83,711
$89,571
$89,571
Salaries
OT Salaries
61-6800-503200
5,808
8,000
10,070
16,718
8,000
$8,000
$8,000
FICA tax expense
61-6800-505000
6,252
6,641
4,764
8,181
7,016
7,464
7,464
Employer Group Insurance Expense
61-6800-506000
18,622
19,937
14,677
20,546
20,287
20,287
20,287
Employee Wellness Benefit
61-6800-506100
275
600
100
300
400
300
300
Employer LGERS Expense
61-6800-507100
9,339
10,505
8,028
12,940
11,785
12,577
12,577
Employer 401 (k) Expense
61-6800-509100
4,096
4,341
3,304
5,347
4,586
4,879
4,879
Subtotal ersonne
Operating and Maintenance
61-6800-504000
548,310
664,221
142,313
664,221
664,221
20,549
20,549
Professional Services
Employee Training
61-6800-510000
1,140
1,000
0
1,000
1,000
1,000
1,000
Travel Expenses/Employees
61-6800-514000
0
700
0
400
700
700
700
Equipment Repairs/Maintenance
61-6800-516200
3,201
15,000
1,305
12,000
15,000
15,000
15,000
Vehicle Repairs
61-6800-517000
164
2,000
564
2,000
2,000
2,000
2,000
Permit Expense
61-6800-525500
2,258
2,900
1,443
2,900
3,000
3,000
3,000
Departmental Supplies/Materials
61-6800-533000
11,184
10,000
4,178
8,500
10,000
10,000
10,000
Chemicals
61-6800-534200
14,862
16,000
8,873
17,746
20,000
20,000
20,000
Uniforms
61-6800-536000
115
1,000
110
1,000
1,100
1,100
1,100
Data Processing
61-6800-544900
5,502
5,220
2,460
5,220
5,220
5,220
5,220
Contracted Services
61-6800-545000
24,980
75
0
0
0
0
Dues and Subscriptions
61-6800-553100
392
950
300
950
950
950
950
Miscellaneous
61-6800-557000
638
250
144
400
400
400
400
Subtotal peratmg
612,747
Other
61-6800-573100
32,406
37,500
18,178
37,500
37,500
37,500
37,500
Capital - General Improvements
Sewer Line Improvements
61-6800-573101
51,598
82,423
66,850
90,000
37,500
37,500
37,500
Capital - Kensington Pump Station
61-6800-572900
5,600
0
0
0
0
0
Capital - Miuddy Creek Pump Station
226,603
3,100,000
33,969
100,000
3,720,000
3,720,000
u tota t er
7,
5,---T795,000
ota s
5
7
PROJECT DESCRIPTION
2023-24
2024-25r$2.5OO.00O
25-26
2026.27
2027-28
TOTAL
Total Cost of Pro ct
FundingSo—
MET
UNMET
PROP.
UNMET
UNMET
PROP.
UNMET
PROP.
UNMET
PROP.
t
5287.500
$287.500
EF
EF
$37.500
$37.500
$250.000
$250,000
$50,000
$50.000
$200,000
$200,000
$150,000
$150.000
$75.000
$75,000
$75,000
E75.900
$75.000
$75,000
E287.500
$287 500
$7500,000
500
0.
EF
EF
_
I
r $37.500
$37.500
$7500,000
$250.000
$260000
$50.000
$50.000
$7.600.000
$200.000
$200,090
$5,000000
$150,000
$150,000
$2,500,000
$75000
$75000
$2500_000
_ E75,000
$75,000
$2.500,000
$75,000
$75,000
__-
$7,500000$287
f287 500$287.500
$287,500
_
$260000
0
$250.000
$100 000
$160.000
$250,000
$3000000
$3000000
0
O
$3,000000
$3,000,000
$3.000,000
$3.000.000
$3,000.000
$3,000,000
. $3.000.000
$3,000,000
___$3.000,000
$3,000,000
$3000000
0
S3.Ofi0000
$3,000,000
f3000000
$3,000,000
14-4k00$_
_
=.
al zro sou ti a3.zrosou a3.zro: al.zro,xu ai,nosou a�rzro.xu ar.uosou
Pimtecle too Parch Raad to Donnaha Rd & Trinit Church Rtl $3 326400 G S3,326AW $3.326, $3,326.400 PM -I- IME3,326.400 $3.326.400 E3,326,400
Waterl Sewer Right of We cl n contr l $34_�_000 EF... $340000 $85, 000 $255 $85,000 $170000 $850001 $85000 E85000 $340000
Total Cost of Equipment
Fundin source
MET
UNMET
PROP.
UNMET
PROP.
UNMET
PROP.
UNMET
PROP.
UNMET
PROP.
UNMET
Public Utilities R' W-Wa and In ru Truck
$40 500
EF
$40 500
$40 500
$40 500
$40 500
PUDIic Utlitiles Service Trucks 4x4 crew ceb inventor, air com re metk a strobe lights, rack
$200 000
EF
$200 9
$100 000
' $700 0
$100 000
E200 000
Public Utilites Dum Bed Truck
S55 000
EF
_
$55
$55
$55 000
$55 0D0
$55,000
$55 000
Public Utilties Flat Bed Truck
545 000
EF
$45,0
$45.000
$45,0D0
$45,000
$45.000
$45 000
Vac All Sewer Vaccum Truck W/ Jeltw
$575 000
L
$575 000
$575 000
$575 000
$575,000
$575 000
Se is Pum Truck Wl Japer 8 F—h Water Tenk
$169 600
EF
_ _
$169 500
E169 500
4100 BS Beckhoe w/ exlenda boom,.thumb ucik bucket changeout 4nl front bucket
$135 000 -
L
$135 0
$135 000
$135 000
Mini Ezcavalor w/ thumb aM ucik cha a bucket
$65 000
EF
_
$65,
$65,0
$65 000
f65 000
Stor Area for neretors m and ul ment
0 000
EF
$200
$200 0
$200,000
$200 000
$200 000
E200 000
GRAND TOTAL $7,831,789 $77.869.2901 $1.885.0001 $75.984.2901 S19.205.5001 $56.778.790 $14.045.000 $42.733.7901 $8.250.0001 $34,283,790 Ml 217,289 $34, 283, 790
FUNDINGl Ultl'F: LF.CEN11
SNF- 5'1 ATE NEVOI.VINO FUND LOAN 4 LOAN/FINANCED EF- ENTk:RPR15F.F'UND
CITY OF KING
WASTEWATER COLLECTION
SYSTEM Permit#: WQCS00350
Response Action & Contingency Plan
TABLE OF CONTENTS
Pump Failure Contingency Plan
Sewer Pump Station Contingency Plan
Wastewater Emergency Spill Response Plan
Emergency Contact List
Pump Station Information
CITY OF KING
PUMP FAILURE CONTINGENCY PLAN
In accordance with the Collection System Permit Section 1-7, the following is a contingency
plan for pump failure at all Sanitary Sewer pump stations:
• The maintenance personnel shall determine the nature of the pump failure and
determine the extent of repairs needed.
• If necessary, emergency equipment will be mobilized and set up to ensure that a SSO
does not occur.
• If it is determined that the pump/controls can be repaired on -site, or if the pump must
be removed to determine the nature of the failure, then the pump and controls shall
be locked and tagged out at the motor control panel before repairs/removal is begun.
• Minor repairs, such as debris removal or minor part replacement, will be completed
by maintenance personnel.
• Major work, such as bearing or seal replacement or motor repair, will be completed by
a local contractor in a timely manner.
There are a small number of spare parts and equipment that are maintained at the
maintenance shop such as:
• Replacement Impellers
• Mechanical seals
• Cutter rings and star blades
• Packing
• Floats
• Portable Generators
• Various electrical control devices
• Some spare pumps
• Level transducers if available
CITY OF KING
SEWER PUMP STATION CONTINGENCY PLAN
The City of King has 8 duplex pump stations, 2 triplex pump stations and 1 quadplex pump
station. The City would respond to each pump failure at each pump station in a similar way.
Each pump station has a primary and a secondary pump. Failure of the primary, secondary, or
both pumps shall initiate this contingency plan with the goal of replacing the failing pump as
soon as possible, unless the station has triplex or quadplex pumps.
If both pumps fail to activate, alarms will be activated. The alarms will contact the water
plant. The ORC will then be called to investigate to determine the reason for the backup or
overflow.
The City of King can do some minor pump repairs on site; however, it is in the best interest of
the City to contract most pump repairs. The City will contract with a local contractor in the
event of pump failure in order to replace or repair the pump as soon as possible.
The City will keep specific details for each pump on site in to expedite pump replacement.
If a pump failure occurs, the ORC will check first for any sanitary sewer overflow. If an
overflow has or is occurring, the ORC will begin containment procedures for the
SSO. Containment is to be in compliance with the Sanitary Sewer Overflow procedures
contained within the Collection System Program. If an S S O is not or has not occurred,
then the ORC will begin diagnosis of the pump failure. If the source is not obvious or is
beyond the City's capabilities to repair, then the ORC will contact a local contractor to
expedite the repair.
Vendor Name
Issue
Contact Name
Phone Number
Carolina Generator
Back Power System
Brad Harrison
336-930-3360
T/K's Electrical
Electrical System
Max Angel
336-391-1201
Material Technology Solutions
TS
Electrical System
Chris Lankford
336408-5965
Lingle Electric
Pumps
702-663-7242
Sunbelt Rentals
Pump Rental
Anthony Horton
980-213-7007
Affordable Septic & Grease
Cleaning
Septic Pumping
Tommy Neal
336462-6228
Septic 911
1 Septic Pumping
1
1 336490-5844
CITY OF KING
WASTEWATER EMERGENCY SPILL RESPONSE PLAN
1. We have a 24/7 emergency number that is to our Water Treatment Plant. The
number is 336-924-8363. For all emergencies after call is made to the water plant,
they then dispatch on call personnel and the ORC's will be contacted of the
emergency and the location.
2. Once the call is made, personnel are dispatched, and they respond as soon as
they are contacted.
3. Sewer equipment list and supplies:
A. Sewer jet trailer/washer and sewer camera
B. Repair supplies are kept at the city maintenance shop.
C. Portable generators for smaller stations, larger stations are equipped with
generators.
D. Pumps are available for smaller stations.
E. Cutters and ceramic seals are available on hand for pumps.
F. Pressure washers, sewer jet and floats are on hand.
4. The wastewater maintenance department in the city budget has allocated funds
for unexpected emergencies.
5. Site sanitation: hydrated lime is used to treat overflow and chlorine tabs are used
in the event wastewater reaches surface waters.
6. Spill overflows are reported immediately to NCDENR, then if the overflow is over
a certain amount and reaches surface waters it is reported to the proper
newspapers and television station if this becomes necessary.
7. The City has a bypass pump around system for two of our stations which are
located at our Spainhour Road station and our Goff Road station. For the other
stations without a bypass pump around system we call in pump trucks to handle
the situation.
City of King
Wastewater
Emergency Contact List
Name
Title
Phone Number
Todd Alley
Collections System ORC
336403-7885
Todd Hill
Collections System Back Up ORC
336403-7887
Robert Pettitt
Water & Wastewater Superintendent
336403-7884
Jeremy Cook
Wastewater Maintenance Operator
336-403-5461
Robbie Boles
Wastewater Maintenance Operator
336403-5730
Ben Marion
City Engineer
336416-0351
City of King Water Treatment Facility
After Hours 24/7 Emergency Line
336-924-8363
City of King Public Utilities Maintenance
Shop
336-9834832
City of King City Hall
336-983-8265
City of King Collections/ Billing
336-985-1100
?R
N °
Dalton L/jotj AI
DANBURY �Gtak
CREEK, uo-
�" GOFF ROAD
I y% r .4
iter'' eykj ♦:
1 ' URCH RO DRIVEc.
1
W° f
1
I OW
1 T
1
1 NK
1 "CREEK-
LITTLEBROOK
r �
I i �
1 . _ — — — — — — — —
TobaceoviTle
Fs
nm�a
x�
,=� Meeetee Y
4n View
0 0.250.5 1 1.5 2
Miles
Town Ferk
Gook
a
CREEK
Legend
t oYitr
RD' 46 _W Pump Station
— GravityMain - -
,,;,m ke - Force Main
s 1 S
y
Rural Hall
Sanitary Sewer System Map
City of King
King, North Carolina