HomeMy WebLinkAboutSW6230705_Design Calculations_20230831 (37) SERENTIY 3,4&5 SCM 16 Antiflotation Calculation Input Data Safety Factor: 1.5 Top Width of Riser(ft) 5 Top Length of Riser(ft) 4 Thickness of Riser(ft) 0.5 Thickness of Bottom of Riser(ft) 0.5 Top of Riser(ft) 283.5 Invert of Riser(ft) 279.5 Volume of Riser(cf) 42 Unit Weight Of Concrete(lb/cf) 150 Unit Weight of Water(lb/cf) 62.4 Block Height(ft) 0.5 Block Width(ft) 5 Block Length(ft) 4 Output Fw(Uplift Force,lb) 4992 Fc(Weight of Concrete,lb) 7800 Design Volume(cf) 52 Design Safety Factor 1.56 Volume OK