Loading...
HomeMy WebLinkAboutWQ0044653_Application (FTSE)_20230808L�1�D Division of Water Resources State of North Carolina Department of Environmental Quality Division of Water Resources FAST TRACK SEWER SYSTEM EXTENSION APPLICATION FTA 06-21 & SUPPORTING DOCUMENTATION Application Number:wQ)U I l 5 (to be completed by DWR) All items must be completed or the application will be returned I. APPLICANT INFORMATION: l . Applicant's name: Forestar (USA) Real Estate Group, Inc. (company, municipality, HOA, utility, etc.) 2. Applicant type: ❑ Individual ® Corporation ❑ General Partnership ❑ Privately -Owned Public Utility ❑ Federal ❑ State/County ❑ Municipal ❑ Other 3. Signature authority's name: Jason Rivenbark per 15A NCAC 02T .0106(b) Title: VP Real Estate Investments & Development 4. Applicant's mailing address: 8041 Arco Corporate Drive, Suite 1 10 City: Raleigh State: NC Zip: 27617 5. Applicant's contact information: Phone number: (919) 804-7228 Email Address: jasonrivenbark@forestar.com 11. PROJECT INFORMATION: 1. Project name: Brightwood Farm 5A 2. Application/Project status: ® Proposed (New Permit) ❑ Existing Permit/Project If a modification, provide the existing permit number: WQ00 and issued date: , For modifications, also attach a detailed narrative description as described in Item G of the checklist. If new construction, but part of a master plan, provide the existing permit number: WQ00 3. County where project is located: Guilford County 4. Approximate Coordinates (Decimal Degrees): Latitude: 36004'32.4"N Longitude: 79''35'25.8"W 5. Parcel ID (if applicable): 105628, 106281, 106271, and 106272 (or Parcel ID to closest downstream sewer) III. CONSULTANT INFORMATION: 1. Professional Engineer: Tyler Wilson, P.E. License Number: 054712 Firm: BGE, Inc. Mailing address: 5440 Wade Park Boulevard, Suite 102 City: Raleigh State: NC Zip: 27607 Phone number: (984) 300-0521 Email Address: twilson(a bgeinc.com IV. WASTEWATER TREATMENT FACILITY (WWTF) INFORMATION: 1. Facility Name: TZ pS�GPermit Number: N C--f= C)Lf'r'�-3 SL� Owner Name: CI Ty p F Cn f�EE/JS30VLQ) V. RECEIVING DOWNSTREAM SEWER INFORMATION: l . Permit Number(s): WQ-0�0;�-4'1 1 2. Downstream (Receiving) Sewer Information: 13 inch ❑N Gravity ❑ Force Main 3. System Wide Collection System Permit Number(s) (if applicable): WQCS Owner Name(s): FORM: FTA 06-21 Page 1 of 5 Vi. GENERAL REQUIREMENTS I . If the Applicant is a Privately -Owned Public Utility, has a Certificate of Public Convenience and Necessity been attached? ❑ Yes ❑ No ® N/A 2. if the Applicant is a Developer of lots to be sold, has a Developer's Operational Agreement (FORM: DEV) been attached? ❑ Yes ❑ No ❑ N/A 3. if the Applicant is a Home/Property Owners' Association, has an HOA/POA Operational Agreement (FORM: HOA) and supplementary documentation as required by 15A NCAC 02T.01 15(c) been attached? ❑ Yes ❑ No ® N/A 4. Origin of wastewater: (check all that apply): ® Residential (individually Owned) ❑ Retail (stores, centers, malls) ❑ Car Wash ❑ Residential (Leased) ❑ Retail with food preparation/service ❑ Hotel and/or Motels ❑ School / preschool / day care ❑ Medical / dental / veterinary facilities ❑ Swimming Pool/Clubhouse ❑ Food and drink facilities ❑ Church ❑ Swimming Pool/Filter Backwash ❑ Businesses / offices / factories ❑ Nursing Home ❑ Other (Explain in Attachment) 5. Nature of wastewater: 100 % Domestic % Commercial % industrial (See 15A NCAC 02T .0103(20)) if industrial, is there a Pretreatment Program in effect? ❑ Yes❑ No 6. Has a flow reduction been approved under 15A NCAC 02T .01 14(f)? ❑ Yes ® No If yes, provide a copy of flow reduction approval letter with this application 7. Summarize wastewater generated by project: Establishment Type (see 02T.0114(f)) Daily Design Flow a,n No. of Units Flow Residential — 4 Bedrooms 120 gal/day/bedroom (480 gal/day/unit) 140 67,200 GPD gal/ GPD gal/ GPD gal/ GPD gal/ GPD gal/ GPD Tot", 67,200 GPD a See 15A NCAC 02T .01 14(b), (d), (e)(1) and (e)(2) for caveats to wastewater design flow rates (i.e., minimum flow per dwelling; proposed unknown non-residential development uses; public access facilities located near high public use areas; and residential property located south or east of the Atlantic Intracoastal Waterway to be used as vacation rentals as defined in G.S. 42A-4). b Per 15A NCAC 02T .01 14(c), design flow rates for establishments not identified [in table 15A NCAC 02T.01 141 shall be determined using available flow data, water using fixtures, occupancy or operation patterns, and other measured data. 8. Wastewater generated by project: 67,200 GPD (per 15A NCAC 02T .0114) Do not include future flows or previously permitted allocations if permitted flow is zero, please indicate why: ❑ Pump Station/Force Main or Gravity Sewer where flow will be permitted in subsequent permits that connect to this line. Please provide supplementary information indicating the approximate timeframe for permitting upstream sewers with flow. ❑ Flow has already been allocated in Permit Number: Issuance Date: ❑ Rehabilitation or replacement of existing sewers with no new flow expected ❑ Other (Explain): FORM: FTA 06-21 Page 2 of 5 N I I. GRAVITY SEWER DESIGN CRITERIA (If Applicable) - 02T .0305 & MDC (Gravity Sewers): I . Summarize gravity sewer to be permitted: Size (inches) Length (feet) Material 8" 3,125 SDR 35 Y Section II & III of the MDC for Permitting of Gravity Sewers contains information related to design criteria Y Section III contains information related to minimum slopes for gravity sewer(s) Y Oversizing lines to meet minimum slope requirements is not allowed and a violation of the MDC VII1. PUMP STATION DESIGN CRITERIA (if Applicable) — 02T .0305 & MDC (Pump Stations/Force Mains): PROVIDE A SEPARATE COPY OF THIS PAGE FOR EACH PUMP STATION INCLUDED IN THIS PROJECT 1. Pump station number or name: N/A 2. Approximate Coordinates (Decimal Degrees): Latitude: Longitude: - 3. Total number of pumps at the pump station: 3. Design flow of the pump station: millions gallons per day (firm capacity) Y This should reflect the total GPM for the pump station with the largest pump out of service. 4. Operational point(s) per pump(s): gallons per minute (GPM) at feet total dynamic head (TDH) 5. Summarize the force main to be permitted (for this Pump Station): Size (inches) Length (feet) Material If any portion of the force main is less than 4-inches in diameter, please identify the method of solids reduction per MDCPSFM Section 2.01 C.1.b. ❑ Grinder Pump ❑ Mechanical Bar Screen ❑ Other (please specify) 6. Power reliability in accordance with 15A NCAC 02T .0305(h)(1): ❑ Standby power source or ❑ Standby pump y Must have automatic activation and telemetry - 15A NCAC 02T.0305(h)(1)(B): ➢ Required for all pump stations with an average daily flow greater than or equal to 15,000 gallons per day ➢ Must be permanent to facility and may not be portable Or if the pump station has an average daily flow less than 15,000 gallons per day 15A NCACO2T.0305(h)(1)(C): ❑ Portable power source with manual activation, quick -connection receptacle and telemetry - or ❑ Portable pumping unit with plugged emergency pump connection and telemetry: y Include documentation that the portable source is owned or contracted by the applicant and is compatible with the station. If the portable power source or pump is dedicated to multiple pump stations, an evaluation of all the pump stations' storage capacities and the rotation schedule of the portable power source or pump, including travel timeframes, shall be provided as part of this permit application in the case of a multiple station power outage. FORM: FTA 06-21 Page 3 of 5 iX. SETBACKS & SEPARATIONS — (02B .0200 & 15A NCAC 02T.0305(f)): l . Does the project comply with all separations/alternatives found in 15A NCAC 02T .0305(f) & (g)? ® Yes [:]No 15A NCAC 02T.0305(f) contains minimum separations that shall be provided for sewer systems: Setback Parameter* Separation Required Storm sewers and other utilities not listed below (vertical) 18 inches --Water mains (vertical - water over sewer preferred, including in benched trenches) 18 inches '-Water mains (horizontal) 10 feet Reclaimed water lines (vertical - reclaimed over sewer) 18 inches Reclaimed water lines (horizontal - reclaimed over sewer) 2 feet **Any private or public water supply source, including any wells, WS-1 waters of Class i or Class li impounded reservoirs used as a source of drinking water, and associated wetlands. 100 feet **Waters classified WS (except WS-1 or WS-V), B, SA, ORW, HQW, or SB from normal high water (or tide elevation) and wetlands associated with these waters (see item IX.2) 50 feet **Any other stream, lake, impoundment, or ground water lowering and surface drainage ditches, as well as wetlands associated with these waters or classified as WL. 10 feet Any building foundation (horizontal) 5 feet Any basement (horizontal) 10 feet Top slope of embankment or cuts of 2 feet or more vertical height 10 feet Drainage systems and interceptor drains 5 feet Any swimming pools 10 feet Final earth grade (vertical) j 36 inches ➢ if noncompliance with 02T.0305(f) or (g), see Section X.1 of this application *15A NCAC 02T.0305(g) contains alternatives where separations in 02T.0305(f) cannot be achieved. Please check "yes" above if these alternatives are used and provide narrative information to explain. **Stream classifications can be identified using the Division's NC Surface Water Classifications webpage 2. Does this project comply with the minimum separation requirements for water mains? ® Yes ❑ No ❑ N/A i> if no, please refer to 15A NCAC 18C.0906(f) for documentation requirements and submit a separate document, signed/sealed by an NC licensed PE, verifying the criteria outlined in that Rule. 3. Does the project comply with separation requirements for wetlands? ❑ Yes ❑ No ® N/A ➢ Please provide supplementary information identifying the areas of non-conformance. Y See the Division's draft separation requirements for situations where separation cannot be met. No variance is required if the alternative design criteria specified is utilized in design and construction. 4. Is the project located in a river basin subject to any State buffer rules? ® Yes Basin name: Cape Fear ❑ No if yes, does the project comply with setbacks found in the river basin rules per 15A NCAC 02B .0200? ® Yes ❑ No y This includes Trout Buffered Streams per 15A NCAC 2B.0202 5. Does the project require coverage/authorization under a 404 Nationwide/individual permits ❑ Yes ® No or 401 Water Quality Certifications? Please provide the permit number/permitting status in the cover letter if coverage/authorization is required. 6. Does project comply with 15A NCAC 02T.0 I 05(c)(6) (additional permits/certifications)? ® Yes ❑ No Per 15A NCAC 02T.0105(c)(6), directly related environmental permits or certification applications must be being prepared, have been applied for, or have been obtained. Issuance of this permit is contingent on issuance of dependent permits (erosion and sedimentation control plans, stormwater management plans, etc.). 7. Does this project include any sewer collection lines that are deemed "high -priority?" ❑ Yes ® No Per 15A NCAC 02T.0402, "high -priority sewer" means any aerial sewer, sewer contacting surface waters, siphon, or sewers positioned parallel to streambanks that are subject to erosion that undermines or deteriorates the sewer. Siphons and sewers suspended through interference/conflict boxes require a variance approval. )o if yes, include an attachment with details for each line, including type (aerial line, size, material, and location). High priority lines shall be inspected by the permittee or its representative at least once every six -months and inspections documented per 15A NCAC 02T.0403(a)(5) or the permittee's individual System -Wide Collection permit. FORM: FTA 06-21 Page 4 of 5 N. CERTIFICATIONS: 1. Does the submitted system comply with 15A NCAC 02T, the Minimum Design Criteria for the Permitting of Pump Stations and Force Mains (latest version), and the Gravity Sewer Minimum Design Criteria (latest version) as applicable? ® Yes ❑ No if no, for projects requiring a single variance, complete and submit the Variance/Alternative Design Request application (VADC 10-14) and supporting documents for review to the Central Office. Approval of the request will be issued concurrently with the approval of the permit, and projects requiring a variance approval may be subject to longer review times. For projects requiring two or more variances or where the variance is determined by the Division to be a significant portion of the project, the full technical review is required. 2. Professional Engineer's Certification: i, _Tyler Wilson, P.E. , attest that this application for Brightwood Farm 5A (Professional Engineer's name from Application Item iiT.1.) (Project Name from Application Item 11.1 ) has been reviewed by me and is accurate, complete and consistent with the information supplied in the plans, specifications, engineering calculations, and all other supporting documentation to the best of my knowledge. I further attest that to the best of my knowledge the proposed design has been prepared in accordance with the applicable regulations, Minimum Design Criteria for Gravity Sewers (latest version), and the Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains (latest version). Although other professionals may have developed certain portions of this submittal package, inclusion of these materials under my signature and seal signifies that i have reviewed this material and have judged it to be consistent with the proposed design. NOTE — in accordance with General Statutes 143-215.6A and 143-215.613, any person who knowingly makes any false statement, representation, or certification in any application package shall be guilty of a Class 2 misdemeanor, which may include a fine not to exceed $10,000, as well as civil penalties up to $25,000 per violation. Misrepresentation of the application information, including failure to disclose any design non-compliance with the applicable Rules and design criteria, may subject the North Carolina -licensed Professional Engineer to referral to the licensing board. (21 NCAC 56.0701) North Carolina Professional Engineer's seal, signature, and date: ,``�C�q,ry^,I- 3 3. Applicant's Certification per 15A NCAC 02T .0106(b): i, Jason Rivenbark attest that this application for Brightwood Farm 5A (Signature Authority Name fi-om Application item 1.3.) (Project Name from Application Item 11.1) attest that this application has been reviewed by me and is accurate and complete to the best of my knowledge. 1 understand that if all required parts of this application are not completed and that if all required supporting documentation and attachments are not included, this application package is subject to being returned as incomplete. i understand that any discharge of wastewater from this non -discharge system to surface waters or the land will result in an immediate enforcement action that may include civil penalties, injunctive relief, and/or criminal prosecution. i will make no claim against the Division of Water Resources should a condition of this permit be violated. i also understand that if all required parts of this application package are not completed and that if all required supporting information and attachments are not included, this application package will be returned to me as incomplete. NOTE — in accordance with General Statutes 143-215.6A and 143-215.6B, any person who knowingly makes any false statement, representation, or certification in any application package shall be guilty of a Class 2 misdemeanor, which may include a fine not to exceed $10,000 as well as civil penalties up to $25,000 per violation. Signature: Date: 05/17/2023 FORM: FTA 06-21 Page 5 of 5 State of North Carolina Department of Environment and Natural Resources DWR Division of Water Resources Division of Water Resotjrcf.- Flow Tracking/Acceptance for Sewer Extension Permit Applications (FTSE 10-18) Enity Requesting Allocation City of Burlington Project Name for which flow is being requested: Brightwood Farm Phase 5A More than one FTSF,-10107 may be requiredfor a single project if the owner of the IdJUP is not responsible for al/pump stations along the route of the proposed wastewater flow. 1. Complete this section only if you are the owner of the wastewater treatment plant. a. WWTP Facility Name: City of Burlington Collection System b. WWTP Facility Permit #: WQCS00008 All flows are in MGPD c. WWTP facility's permitted flow Allocation from Greensboro 0.900 d. Estimated obligated flow not yet tributary to the WWTP 0.122 e. WWTP facility's actual avg. flow 0.185 f. Total flow for this specific request 0.067 g. Total actual and obligated flows to the facility 0.374 h. Percent of permitted flow used 41.6% II. Complete this section for each pump station you are responsible for along the route of this List pump stations located between the project connection point and the WWTP : None (A) (B) (C) (D)=(B+C) (E)=(A-D) Obligated, Total Design Approx. Not Yet Current Flow Firm Average Daily Current Avg. Tributary Plus Pump Station Capacity, * Flow** Daily Flow, Daily Flow, Obligated Available Name GPD (Firm/pf), GPD GPD GPD Flow Capacity*** None * The Firm Capacity of any pump station is defined as the maximum pumped flow that can be achieved with the largest pump taken out of service. ** Design Average Daily Flow is the firm capacity of the pumpstation divided by a peaking factor (pf) not less than 2.5. *** A Planning Assessment Addendum shall be attached for each pump station located between the project connection point and the WWTP where the Available Capacity 5 0. Downstream Facility Name (Sewer) : Brightwood Farms Phase 4A, Sec 2D-3D Downstream Permit Number: WQ0042491 Page 1 of 2 FTSE 10-18 Certification Statement: I, W. Todd Lambert, P.E. certify to the best of my knowledge that the addition of the volume of wastewater to be permitted in this project has been evaluated along the route to the receiving wastewater treatment facility and that the flow from this project is not anticipated to cause any capacity related sanitary sewer overflows or overburden any downstream pump station en route to the receiving treatment plant under normal circumstances, given the implementation of the planned improvements identified in the planning asseessment where applicable. This analysis has been performed in accordance with local established policies and procedures using the best available data. This certification applies to those items listed above in Sections I and I1 plus all attached planning assessment addendums for which I am the responsible party. Signature of this form certifies that the receiving collection system or treatment works has adequate capacity to transport and treat the proposed new wastewater. Signing Official Signature City Engineer Title of Signing Official Date Page 2 of 2 FTSE 10-18 City of Greensboro Water Resources Department Ar_ Engineering Division 2602 S. Elm -Eugene Street Greensboro, NC 27406 Flow Tracking/Acceptance Request for GREENSBORO Sewer Extension Permit Applications Project Applicant's Name: City of Burlington Project Name: Brightwood Farms Phase 5A Project Address: Preakness Parkway (SR 5307 Applicant's Contact Information: Phone #: (336) 222-5050 Signing Official Name & Title: Todd Lambert, City Engineer Mailing Address: City Burlington 425 S Lexington Ave Email engineering@burlingtonnc.gov State NC TRC Plan # N/A Email: engineering@burlingtonnc.gov Zip 27215 Phone (336) 222-5050 Signature: —7) Date: Engineer Contact Information: Name: Tyler Wilson, PE- BGE, Inc. Email: TWilson@bgeinc.com Phone: 984-300-0521 Has this project been approved through TRC: No Yes TRC Project # Project is: New Modification Brief description of project (Include overall site plan if available): 140 4-bedroom townhomes Type of Flow (circle majority): Residential Commercial Industrial If any Industrial flow, have you submitted a SIU permit? Yes No Significant Industrial User Permit Information I Greensboro, NC (greensboro-nc.gov) FORM: COG-FTAR-08/2022 Page 1 of 2 Provide the wastewater flow calculations used in determining the permitted flow in accordance with 15A NCAC 2T .0114 or the design flow for line in the space below. Values other than that in 15A NCAC 2T .0114 (b) and (c) must be supported with actual water or wastewater use data in accordance with 15A NCAC 2T .0114 (f). Attach additional sheets if necessary. 140 units @ 120 gal/day/bdrm (480 gal/day/unit)= 67,200 gpd WWTP Facility where flow will be tributary: X❑ T.Z. Osborne NCO047384 ❑ High Point NCO024210 New Lift Station (all new lift stations must be preapproved by Water Resources:) Public (sized for basin): Yes Private: Yes Complete this section if a new pump station will transport wastewater flows as a part of this project. Proposed Pump Station Firm Capacity Force Main Discharge Point (GPM) (Size/Len--th) M( HID#) For City of Greensboro Water Resource Use Only: Does the flow transmit through a public lift station? Yes No If so which pump stations: FORM: COG-FTAR-08/2022 Page 2 of 2 State of North Carolina Department of Environmental Quality Division of Water Resources Flow Tracking for Sewer Extension Applications (FTSE 10-18) Entity Requesting Allocation: City of Burlington Project Name for which flow is being requested: Brightwood Fanns Phase 5A Afore than one FTSE may be required for a single project if the owner of the WTVTP is not responsible for all pump stations along the route of the proposed wastewater flow. 1. Complete this section only if you are the owner of the wastewater treatment plant. a. WWTP Facility Name: _ b. WWTP Facility Permit # T.Z. Osborne NCO047384 c. WWTP facility's permitted flow d. Estimated obligated flow not yet tributary to the WWTP e. WWTP facility's actual avg. flow f. Total flow for this specific request g. Total actual and obligated flows to the facility h. Percent of permitted flow used All flows are in MGD 56.0 6.537 33.110 0.0672 41.066 73.3% II. Complete this section for each pump station you are responsible for along the route of this proposed wastewater flow. List pump stations located between the project connection point and the WWTP: (A) (B) (C) (D)=(B+C) (E)=(A-D) Design Obligated, Pump Pump Average Approx. Not Yet Total Current Station Station Firm Daily Flow** Current Tributary Flow Plus (Name or Permit Capacity, * (Firm / p0, Avg. Daily Daily Flow, Obligated Available Number) No. MGD MGD Flow, MGD MGD Flow Capacity*** Rock 37034 4.32 1.728 1.056 0.5103 1.5663 0.1617 Stewart 38555 10.224 5.0614 1.8317 0.3348 2.1665 2.8949 * The Firm Capacity (design flow) of any pump station is defined as the maximum pumped flow that can be achieved with the largest pump taken out of service. ** Design Average Daily Flow is the firm capacity of the pump station divided by a peaking factor (pf) not less than 2.5, per Section 2.02(A)(4)(c) of the Minimum Design Criteria. *** A Planning Assessment Addendum shall be attached for each pump station located between the project connection point and the WWTP where the Available Capacity is < 0. Downstream Facility Name (Sewer): City of Greenboro T.Z. Osborne Downstream Permit Number: NC047384 Page 1 of 6 FTSE;..>>: III. Certification Statement: I Wendy Messer certify to the best of my knowledge that the addition of the volume of wastewater to be permitted in this project has been evaluated along the route to the receiving wastewater treatment facility and that the flow from this project is not anticipated to cause any capacity related sanitary sewer overflows or overburden any downstream pump station en route to the receiving treatment plant under normal circumstances, given the implementation of the planned improvements identified in the planning assessment where applicable. This analysis has been performed in accordance with local established policies and procedures using the best available data. This certification applies to those items listed above in Sections I and II plus all attached planning assessment addendums for which I am the responsible party. Signature of this form certifies that the receiving collection system or treatment works has adequate capacity to transport and treat the proposed new wastewater. Signing Official Sthature -eal " S-d� Titleof Si ing Official Di3d Ily d by Wendy Messer ON JS='& Wendy M e s s e r E hd phrey nessxr@greensbom nc gov, O:. G1y A Greensboro, GN=Wendy Messer Di19 ' J 13, 07 13 99 5121-04'00' Date Page 2 of 6 FTS E 10-18 U(�(�(� U.S. DEPARTMENT OF THE INTERIOR ,,,,� GIBSONVILLE QUADRANGLE J�]J U.S. GEOLOGIUL SURVEY S� NORTH UROLINA „yyy�y ►.r US Topo ),6NJNIxtE SERIES m to ;x 21� E » 26 .i 'd t9 t0 t� 5! Il to tV 98 9) 1 �z- O FLIT\' I;IIINII\\III I'. n PROJECT LOCATION .92 1 _ > vl V ............. hh 1 M .: < It e2 v J F ��i •_ "i����7� , .��2 � itJ .t yi�7 t _.1��-�'r� : 1 ( �r IS i s �..... - _ 24 25 26 - 21 - -- 18 39 )0 )t 32 13 l4 "S'^^E umm cewq 1 surrey l` SCALE 1:3N 000 sw9 cuss = m�ia- .. rc... e.r-..aeM-. � •x�uaa 1 ew _ o rmo � •....w..ra� _, r�.� L w.. r.... � IN .mom -...� �.., m ....�..tm. Ta�.t..>e.., u..••...«..t.�..*�.wwex.. �.�-,.< 6�' ' ,..moo GIBSONVILLE, NC July 26, 2023 Winston-Salem Regional Office — Water Quality Section 450 W. Hanes Mill Road Suite 300 Winston-Salem, North Carolina 27105 (336) 776-9800 Re: Brightwood Farm — Phase 5A — Fast Track Sewer System Extension To whom it may concern, BGE inc., on behalf of Forestar (USA) Real Estate Group Inc., submit this Fast Track Sewer System Extension Application for the Brightwood Farm — Phase 5A project. The project is located at 6816 Preakness Parkway, Whitsett, Guilford County, NC 23229 and consists of 140, 4-bedroom, townhome units and associated infrastructure. There is 3,125 LF of 8" SDR sewer proposed to serve the community and tie into the existing sewer system within the Brightwood Farm development. Included in this submittal are application for acceptance from the City of Burlington and the City of Greensboro. This is because the sewer lines are owned by the City of Burlington, but the treatment is by the City of Greensboro. The following items are included in the submittal: l . DWR - Fast Track Sewer System Extension Application 2. Cover Letter 3. Check for $480.00 4. Flow Tracking/Acceptance for Sewer Extension Permit Application — City of Burlington 5. Flow Tracking/Acceptance Request for Sewer Extension Permit Application - City of Greensboro 6. Flow Tracking for Sewer Extension Application - City of Greensboro 7. Site Maps 8. Developer's Operational Agreement Sincerely, Tyler Wilson, P.E. Project Engineer Land/Site — Raleigh BGE, Inc. • 5440 Wade Park Boulevard Suite 102 • Raleigh, NC 27607 • 919-276-01 1 1 Environmental duality Received AUG 0 8 2023 Winston-Salem Regional Office Date: July 26, 2023 To: Winston-Salem Regional Office — Water Quality Section 450 W. Hanes Mill Road Suite 300 Winston-Salem, North Carolina 27105 (336) 776-9800 From: Tyler Wilson, P.E. BGE, Inc. 5440 Wade Park Blvd., Suite 102 Raleigh, NC 27607 Reference: Brightwood Farm — Phase 5A — Fast Track Sewer System Extension Item No. 1 Number of Copies 2 Description DWR - Fast Track Sewer System Extension Application 2 1 Cover Letter 3 l Check for $480.00 4 1 Flow Tracking/Acceptance for Sewer Extension Permit Application — City of Burlington 5 1 Flow Tracking/Acceptance Request for Sewer Extension Permit Application - City of Greensboro 6 1 Flow Tracking for Sewer Extension Application - City of Greensboro 7 1 Site Maps 8 1 Developer's Operational Agreement Comments: If there are any questions, please call Tyler Wilson at 984-300-0521 or TWilson@bgeinc.com. Thank you. Serving. Leading. Solving.'