HomeMy WebLinkAboutNC0046531_Compliance Evaluation Inspection_20230809ROY COOPER Governor ELIZABETH S. BISER Secretary RICHARD E. ROGERS, JR. Director Zac Hauser, Sr. Manager Terminal Operations Colonial Pipeline Company 7524 Kenstead Circle Charlotte, NC 28208 NORTH CAROLINA Environmental Quality August 9, 2023 SUBJECT: Compliance Evaluation Inspection Colonial Terminals Operating Co., LLC/Lincoln Terminal NPDES Permit No. NCO046531 Mecklenburg County Dear Mr. Hauser: Enclosed is a copy of the Compliance Evaluation Inspection (CEI) Report for the inspection conducted at the subject facility on August 2, 2023, by Mr. Wes Bell of this Office. Please advise all environmental staff of our findings by forwarding the enclosed report. Should you have any questions concerning this report, please do not hesitate to contact Mr. Bell at (704) 235-2192 or at wes.bell@deq.nc. gov. Enclosure: Inspection Report Cc: NPDES Program Files - Laserfiche Sincerely, DocuSigned by: A wNNuft F161 FB69A2D84A3... Andrew H. Pitner, P.G. Regional Supervisor Water Quality Regional Operations Section Mooresville Regional Office Division of Water Resources, NCDEQ North Carolina Department of Environmental Quality I Division of Water Resources Mooresville Regional Office 1 610 East Center Avenue, Suite 301 1 Mooresville, North Carolina 28115 704.663.1699 United States Environmental Protection Agency Form Approved. EPA Washington, D.C. 20460 OMB No. 2040-0057 Water Compliance Inspection Report Approval expires 8-31-98 Section A: National Data System Coding (i.e., PCS) Transaction Code NPDES yr/mo/day Inspection Type Inspector Fac Type 1 IN 1 2 u 3 I NCO046531 111 121 23/08/02 I17 18 LC] I 19 I s I 20L] 21111I I I I I I I II I I I I I I I I I I I I I I I I I I I I I I I II I I I I I r6 Inspection Work Days Facility Self -Monitoring Evaluation Rating B1 QA ---------------------- Reserved ------------------- 67 2.0 70LJ 71 I„ I 72 L71 74 79 I I I I 80 Section B: Facility Data Name and Location of Facility Inspected (For Industrial Users discharging to POTW, also include Entry Time/Date Permit Effective Date POTW name and NPDES Dermit Number) 12:26PM 23/08/02 21/07/01 Lincoln Terminal 7720 Mount Holly Rd Exit Time/Date Permit Expiration Date Charlotte NC 28214 12:47PM 23/08/02 25/05/31 Name(s) of Onsite Representative(s)/Titles(s)/Phone and Fax Number(s) Other Facility Data Maribeth D Hughes//704-458-3993 / Matthew Joseph Brundage/ORC/704-523-4726/ Name, Address of Responsible Official/Title/Phone and Fax Number Contacted Zach Hauser,7720 Mount Holly Rd Charlotte NC 28214//770-876-0247/ No Section C: Areas Evaluated During Inspection (Check only those areas evaluated) Permit 0 Flow Measurement Operations & Maintenar Records/Reports Self -Monitoring Progran 0 Facility Site Review Effluent/Receiving Wate Laboratory Section D: Summary of Finding/Comments (Attach additional sheets of narrative and checklists as necessary) (See attachment summary) Name(s) and Signature(s) of Inspector(s) Agency/Office/Phone and Fax Numbers Date cuSigned by: Wes Bell DWR/MRO WQ/704-663-1699 Ext.2192/ 8/9/2023 Be& E�: 96D90=437... Signature of Man e`n%hV0rR"iewer Agency/Office/Phone and Fax Numbers Date Andrew PitnL—A4-� H P"MR/MRO WQ/704-663-1699 Ext.2180/ 8/9/2023 F161F969A2D84A3... EPA Form 3560-3 (Rev 9-94) Previous editions are obsolete. Page# NPDES yr/mo/day Inspection Type NCO046531 I11 12I 23/08/02 117 18 i c i Section D: Summary of Finding/Comments (Attach additional sheets of narrative and checklists as necessary) Page# Permit: NCO046531 Owner -Facility: Lincoln Terminal Inspection Date: 08/02/2023 Inspection Type: Compliance Evaluation Permit Yes No NA NE (If the present permit expires in 6 months or less). Has the permittee submitted a new ❑ ❑ ■ ❑ application? Is the facility as described in the permit? ■ ❑ ❑ ❑ # Are there any special conditions for the permit? ■ ❑ ❑ ❑ Is access to the plant site restricted to the general public? ■ ❑ ❑ ❑ Is the inspector granted access to all areas for inspection? ■ ❑ ❑ ❑ Comment: Outfall 001 consists of stormwater from the secondary containment structures (ASTs and loading rack area. The stormwater from the loading rack area is treated by an oil/water separator and carbon adsorption system (1 vessel was in service) prior to being discharged into the secondary containment structure that is equipped with a manually activated discharge valve (normally secured closed) The last compliance evaluation inspection at this facility was performed by DWR staff on 2/15/2020. Record Keeping Yes No NA NE Are records kept and maintained as required by the permit? ■ ❑ ❑ ❑ Is all required information readily available, complete and current? ■ ❑ ❑ ❑ Are all records maintained for 3 years (lab. reg. required 5 years)? ■ ❑ ❑ ❑ Are analytical results consistent with data reported on DMRs? ❑ ■ ❑ ❑ Is the chain -of -custody complete? ■ ❑ ❑ ❑ Dates, times and location of sampling ■ Name of individual performing the sampling ■ Results of analysis and calibration ■ Dates of analysis ■ Name of person performing analyses ■ Transported COCs ■ Are DMRs complete: do they include all permit parameters? ■ ❑ ❑ ❑ Has the facility submitted its annual compliance report to users and DWQ? ❑ ❑ ■ ❑ (If the facility is = or > 5 MGD permitted flow) Do they operate 24/7 with a certified ❑ ❑ ■ ❑ operator on each shift? Is the ORC visitation log available and current? ■ ❑ ❑ ❑ Is the ORC certified at grade equal to or higher than the facility classification? ■ ❑ ❑ ❑ Is the backup operator certified at one grade less or greater than the facility ■ ❑ ❑ ❑ classification? Is a copy of the current NPDES permit available on site? ■ ❑ ❑ ❑ Facility has copy of previous year's Annual Report on file for review? ❑ ❑ ■ ❑ Page# 3 Permit: NCO046531 Inspection Date: 08/02/2023 Record Keeping Owner -Facility: Lincoln Terminal Inspection Type: Compliance Evaluation Yes No NA NE Comment: The records reviewed durinq the inspection were organized and well maintained Discharge Monitoring Reports (eDMRs) were reviewed for the period July 2022 through June 2023. No limit and/or monitoring violations were reported. The facility staff will review and revise all applicable eDMRs starting in January 2022 to correct several transcription errors including units of measurement, flow values, ORC and/Backup ORC visitation dates/times and EPA Method 625 and toxicity results. Facility staff must ensure all eDMRs are accurate and complete prior to submittal. Laboratory Yes No NA NE Are field parameters performed by certified personnel or laboratory? ❑ ❑ 0 ❑ Are all other parameters(excluding field parameters) performed by a certified lab? 0 ❑ ❑ ❑ # Is the facility using a contract lab? ■ ❑ ❑ ❑ # Is proper temperature set for sample storage (kept at less than or equal to 6.0 ❑ ❑ 0 ❑ degrees Celsius)? Incubator (Fecal Coliform) set to 44.5 degrees Celsius+/- 0.2 degrees? ❑ ❑ 0 ❑ Incubator (BOD) set to 20.0 degrees Celsius +/- 1.0 degrees? ❑ ❑ 0 ❑ Comment: Pace Analytical Services and ETT Environmental, Inc. (toxicity) have been contracted to perform permit -required analyses. S&ME staff are contracted to collect effluent samples. Facility staff should notify the contracted laboratory to analyze future effluent total recoverable phenolics samples at a lower detection limit (5 ug/L instead of 40 uq/L). Analytical methods shall be in accordance with 40 CFR Part 136 and shall be sufficiently sensitive to determine whether parameters are present in concentrations greater than applicable standards and criteria. Effluent Sampling Yes No NA NE Is composite sampling flow proportional? ❑ ❑ 0 ❑ Is sample collected below all treatment units? 0 ❑ ❑ ❑ Is proper volume collected? 0 ❑ ❑ ❑ Is the tubing clean? ❑ ❑ 0 ❑ # Is proper temperature set for sample storage (kept at less than or equal to 6.0 ❑ ❑ ■ ❑ degrees Celsius)? Is the facility sampling performed as required by the permit (frequency, sampling type ■ ❑ ❑ ❑ representative)? Comment: The subject permit requires effluent grab samples. Facilitv staff must ensure that the effluent is collected directly into the oil & arease sample container (no intermediate sample containers/devices). Operations & Maintenance Yes No NA NE Is the plant generally clean with acceptable housekeeping? 0 ❑ ❑ ❑ Page# 4 Permit: NCO046531 Inspection Date: 08/02/2023 Owner -Facility: Lincoln Terminal Inspection Type: Compliance Evaluation Operations & Maintenance Yes No NA NE Does the facility analyze process control parameters, for ex: MLSS, MCRT, Settleable ❑ ❑ ❑ Solids, pH, DO, Sludge Judge, and other that are applicable? Comment: The NPDES facilities appeared to be properly operated and well maintained. The entire facility (including NPDES facilities) is inspected on a daily basis by the on -site staff. STAT, Inc. has been contracted to remove and dispose of the free product from the oil/water separator. Calgon has been contracted to perform maintenance on the carbon adsorption system. Spent carbon vessels are disposed at a permitted landfill. Flow Measurement - Effluent # Is flow meter used for reporting? Is flow meter calibrated annually? Is the flow meter operational? (If units are separated) Does the chart recorder match the flow meter? Yes No NA NE • ❑ ❑ ❑ • ❑ ❑ ❑ ■ ❑ ❑ ❑ ❑ ❑ ■ ❑ Comment: The calculated flows for Outfall 001 is based on the Rational Equation criteria (area of drainage area, total rainfall, etc.). The facility staff must ensure all effluent discharges are measured and reported on the eDMRs. Effluent Pipe Yes No NA NE Is right of way to the outfall properly maintained? 0 ❑ ❑ ❑ Are the receiving water free of foam other than trace amounts and other debris? 0 ❑ ❑ ❑ If effluent (diffuser pipes are required) are they operating properly? ❑ ❑ ■ ❑ Comment: Outfall 001 was not discharging at the time of the inspection. Page# 5