Loading...
HomeMy WebLinkAboutNCGNE1630_NE Denial Report_20230811 Compliance Inspection Report Permit:NCGNE1630 Effective: Expiration: Owner: Braven Environmental LLC SOC: Effective: Expiration: Facility: Braven Environmental, LLC County: Wake 517 N Industrial Dr Region: Raleigh Wendell NC 27591 Contact Person:Christopher Serrati Title: Phone: 501-628-4793 Directions to Facility: System Classifications: Primary ORC: Certification: Phone: Secondary ORC(s): On-Site Representative(s): Related Permits: Inspection Date: 08/11/2023 Entry Time 12:OOPM Exit Time: 01:OOPM Primary Inspector:Thaddeus W Valentine Phone: Secondary Inspector(s): Reason for Inspection: Routine Inspection Type: Compliance Evaluation Permit Inspection Type: Stormwater Discharge, No Exposure Certificate Facility Status: ❑ Compliant Not Compliant Question Areas: Miscellaneous Questions Misc (See attachment summary) Page 1 of 3 Permit: NCGNE1630 Owner-Facility:Braven Environmental LLC Inspection Date: 08/11/2023 Inspection Type:Compliance Evaluation Reason for Visit: Routine Inspection Summary: The facility has numerious poly totes located outside, containing petroleum typed fluids, without secondary containment. Two of the 250 gallon totes filled with fluid were located next to a stormdrain drop inlet. All containers located outside should be within a secondary containment and covered if not in use There are opened containers outside exposed to stormwater that should be covered and stored inside when not in use There are pallets outside exposed to stormwater that should be stored out of the weather The concrete secondary containment area has contaminated water built up inside that should be disposed of properly. Any water pumped from the secondary containment should be tested before being released. The product buildup and the visable sheen on the water in the secondary containment indicates the water must be disposed of off site at approved facility. Any water with a visable sheen must be disposed of properly There is an aboveground Oil Water Seperator(OWS)on site that was reportedly for water removal from secondary containment. OWS can only function if water is gravity feed to it(not pumped)and the OWS has been designed to handle the particular rate of flow that will be discharged to it. It should also only be used as a backup for unintentional discharges of water containing heavy oils and should never be used for contaminatated water remediation disposal devise from secondary containment Any water with a sheen should be considered contaminated and disposed of properly I confirmed with Waste Management(Autumn Romanski)that they did not approve this OWS for that reason For the reasons stated , the No Exposure apllied for is Denied Page 2 of 3 Permit: NCGNE1630 Owner-Facility:Braven Environmental LLC Inspection Date: 08/11/2023 Inspection Type:Compliance Evaluation Reason for Visit: Routine MISc Yes No NA NE Is the facility compliant? ❑ 0 ❑ ❑ Comment: The facility diesn't qualify for the no exposure due to outside exposures Page 3 of 3