HomeMy WebLinkAboutNC0066796_CEI_20230815DocuSign Envelope ID: 69E32EAA-052A-46AB-BB98-54D79E365AD1 ROY COOPER Goeernor ELIZABETH S. B1SER Secrerary RiCHARD E. ROGERS, JR. Director Clark Wyatt, Director Maintenance Buncombe County Schools 175 Bingham Rd Asheville, NC 28806 i NORTH CAROLINA Environmental Quality August 15, 2023 SUBJECT: NOTICE OF DEFICIENCY Tracking Number: NOD-2023-PC-0219 Permit No. NCO066796 Leicester Elementary School Buncombe County Dear Permittee: The North Carolina Division of Water Resources conducted an inspection of the Leicester Elementary School on July 31, 2023. This inspection was conducted to verify that the facility is operating in compliance with the conditions and limitations specified in NPDES WW Permit No. NC0066796. A summary of the findings and comments noted during the inspection are provided in the enclosed copy of the inspection report. The Compliance Evaluation inspection was conducted by Division of Water Resources staff from the Asheville Regional Office. The following deficiency(s) was noted during the inspection: Inspection Area Description of Deficiency Effluent Pipe Effluent pipe could not be found at the time of the inspection. Remedial actions should have already been taken to correct this problem and prevent further occurrences in the future. The Division of Water Resources may pursue enforcement action for this and any additional violations of State law. To prevent further action, carefully review these deficiencies and address the causes of non-compliance to prevent the recurrence of similar situations. If you should have any questions, please do not hesitate to contact Rachel Rose with the Water Quality Regional Operations Section in the Asheville Regional Office at 828-296-4500. Sincerely, CDocuSigned by: ayut,�, �jbSS E397192DABFB4FF... ��- D North lk Rt io Degartc enl0f EnriS Rgh lal Qva1 I Division at rih C Resources M1she'+ilk Regional Office 12090 US -Highway 70 I Swannaraa, North Catalina 28778 62&296.9590 DocuSign Envelope ID: 69E32EAA-052A-46AB-BB98-54D79E365AD1 ATTACHMENTS Ec: Laserfiche Daniel Boss, Assistant Regional Supervisor Water Quality Regional Operations Section Asheville Regional Office Division of Water Resources, NCDEQ D NarrhCaroll�a Degarrmrnl �r E��;.o�m��t�i OvaIhV I NvlsiwofWmer Reno—s Ashr 11k Rr9ional Office 1209O US-RghwW70 I S—n—.North Ca 1hP 28778 Via^ +� 62&296.9590 DocuSign Envelope ID: 69E32EAA-052A-46AB-BB98-54D79E365AD1 United States Environmental Protection Agency Form Approved. EPA Washington, D.C. 20460 OMB No. 2040-0057 Water Compliance Inspection Report Approval expires 8-31-98 Section A: National Data System Coding (i.e., PCS) Transaction Code NPDES yr/mo/day Inspection Type Inspector Fac Type 1 IN 1 2 u 3 I NC0066796 111 121 23/07/31 I17 18 LC] I 19 I s I 20L] 21111I I I I I I I II I I I I I I I I I I I I I I I I I I I I I I I II I I I I I r6 Inspection Work Days Facility Self -Monitoring Evaluation Rating B1 QA ---------------------- Reserved ------------------- 67 I 72 I n, I 71 I 74 79 I I I I I I I80 701 I 71 I LL -1 I I LJ Section B: Facility Data Name and Location of Facility Inspected (For Industrial Users discharging to POTW, also include Entry Time/Date Permit Effective Date POTW name and NPDES permit Number) 09:OOAM 23/07/31 21/10/01 Leicester Elementary School NCSR 1615 Gilbert Rd Exit Time/Date Permit Expiration Date Leicester NC 28748 10:30AM 23/07/31 25/12/31 Name(s) of Onsite Representative(s)/Titles(s)/Phone and Fax Number(s) Other Facility Data Robert P Barr/ORC/828-251-1900/ Name, Address of Responsible Official/Title/Phone and Fax Number Contacted Clark Wyatt,175 Bingham Rd Asheville NC 28806/Maintenance Director/828-232-4244/ No Section C: Areas Evaluated During Inspection (Check only those areas evaluated) Permit 0 Flow Measurement Operations & Maintenar 0 Records/Reports Self -Monitoring Progran 0 Facility Site Review Effluent/Receiving Wate Section D: Summary of Finding/Comments (Attach additional sheets of narrative and checklists as necessary) (See attachment summary) Name(s) and Signature(s) of Inspector(s) Agency/Office/Phone and Fax Numbers Date Lauren E Armeni u N� p 16/2023 DWR/ARO WQ/828-296-4500/ 2'B176487707°EB- Rachel Rose DWR/ARO WQ/828-296-4500/ °°`" s d1, 8/16/2023 Signature of Management Q A Reviewer Agency/Office/Phone and Fax Numbers Date E8/21/2023 Vxuutt bass EPA Form 3560-3 (Rev 9-94) Previous editions are obsolete. Page# DocuSign Envelope ID: 69E32EAA-052A-46AB-BB98-54D79E365AD1 NPDES yr/mo/day Inspection Type (Cont.) NCO066796 I11 12I 23/07/31 117 18 ici cJ Section D: Summary of Finding/Comments (Attach additional sheets of narrative and checklists as necessary) Rachel Rose and Lauren Armeni, with the Asheville Regional Office (ARO), met with Robert Barr (ORC) to conduct a Compliance Evaluation Inspection on July 31, 2023 for the Leicester Elementary School WWTP. This inspection was conducted to determine whether the facility is being operated and maintained in compliance with NPDES Permit No. NC0066796. The following item was noted during the inspection: Sand Filter: At the time of the inspection, the sand filter was full of gravel which covered the majority of the piping; however, the ends of the distribution lines were elevated above the gravel (picutres attached). There was no flow from the distribution lines at the time of the inspection. There was some vegetation on top of the gravel, but not enough to hinder the functionality. Effluent Pipe: The effluent pipe could not be found due to excessive vegetation alnog the bank of the creek. The following deficiency was noted at the time of the inspection: Effluent Pipe: At the time of the inspection, the effluent pipe was not able to be evaluated because it could not be found. There was high overgrowth of vegetation making it too difficult for the ORC and the inspectors to find the effluent pipe. Page# DocuSign Envelope ID: 69E32EAA-052A-46AB-BB98-54D79E365AD1 Permit: NCO066796 Inspection Date: 07/31/2023 Owner -Facility: Leicester Elementary School Inspection Type: Compliance Evaluation Permit (If the present permit expires in 6 months or less). Has the permittee submitted a new application? Is the facility as described in the permit? # Are there any special conditions for the permit? Is access to the plant site restricted to the general public? Is the inspector granted access to all areas for inspection? Comment: Operations & Maintenance Is the plant generally clean with acceptable housekeeping? Does the facility analyze process control parameters, for ex: MLSS, MCRT, Settleable Solids, pH, DO, Sludge Judge, and other that are applicable? Yes No NA NE ❑ ❑ ■ ❑ ■ ❑ ❑ ❑ ❑ ■ ❑ ❑ ■ ❑ ❑ ❑ ■ ❑ ❑ ❑ Yes No NA NE ■ ❑ ❑ ❑ ■ ❑ ❑ ❑ Comment: The process controls analyzed are using a sludge fudge to measure the sludge blanket in the septic tank in order to evaluate when the tank needs to be pumped. Record Keeping Yes No NA NE Are records kept and maintained as required by the permit? ■ ❑ ❑ ❑ Is all required information readily available, complete and current? ■ ❑ ❑ ❑ Are all records maintained for 3 years (lab. reg. required 5 years)? ■ ❑ ❑ ❑ Are analytical results consistent with data reported on DMRs? ■ ❑ ❑ ❑ Is the chain -of -custody complete? ■ ❑ ❑ ❑ Dates, times and location of sampling ■ Name of individual performing the sampling ■ Results of analysis and calibration ■ Dates of analysis ■ Name of person performing analyses ■ Transported COCs ■ Are DMRs complete: do they include all permit parameters? ■ ❑ ❑ ❑ Has the facility submitted its annual compliance report to users and DWQ? ❑ ❑ ■ ❑ (If the facility is = or > 5 MGD permitted flow) Do they operate 24/7 with a certified ❑ ❑ ■ ❑ operator on each shift? Is the ORC visitation log available and current? ■ ❑ ❑ ❑ Is the ORC certified at grade equal to or higher than the facility classification? ■ ❑ ❑ ❑ Is the backup operator certified at one grade less or greater than the facility ■ ❑ ❑ ❑ classification? Page# 3 DocuSign Envelope ID: 69E32EAA-052A-46AB-BB98-54D79E365AD1 Permit: NCO066796 Inspection Date: 07/31/2023 Record Keeping Owner -Facility: Leicester Elementary School Inspection Type: Compliance Evaluation Is a copy of the current NPDES permit available on site? Facility has copy of previous year's Annual Report on file for review? Comment: Septic Tank (If pumps are used) Is an audible and visual alarm operational? Is septic tank pumped on a schedule? Are pumps or syphons operating properly? Are high and low water alarms operating properly? Yes No NA NE ■ ❑ ❑ ❑ ❑ ❑ M ❑ Yes No NA NE ❑ ❑ ■ ❑ ❑ ❑ ❑ ❑ ❑ ■ ❑ ❑ ❑ ■ ❑ Comment: The tank is pumped about once per year or less, depending on the results from the sludge fudge. The dosing tank is gravity fed. The tank was last pumped on August 17, 2022 by Mike's Septic Tank Service. Sand Filters (Low rate) Yes No NA NE (If pumps are used) Is an audible and visible alarm Present and operational? ❑ ❑ ■ ❑ Is the distribution box level and watertight? ❑ ❑ ❑ ■ Is sand filter free of ponding? 0 ❑ ❑ ❑ Is the sand filter effluent re -circulated at a valid ratio? ❑ ❑ 0 ❑ # Is the sand filter surface free of algae or excessive vegetation? ■ ❑ ❑ ❑ # Is the sand filter effluent re -circulated at a valid ratio? (Approximately 3 to 1) ❑ ❑ ■ ❑ Comment: At the time of the inspection, the sand bed was full of gravel which covered the maiorit of the piping; however, the ends of the distribution lines were elevated above the gravel. There was no flow from the distribution lines at the time of the inspection. The sand was last changed 15-20 years ago. There was some vegetation on top of the gravel, but not enough to hinder the functionality. See summary for details. Disinfection -Tablet Yes No NA NE Are tablet chlorinators operational? 0 ❑ ❑ ❑ Are the tablets the proper size and type? 0 ❑ ❑ ❑ Number of tubes in use? 2 Is the level of chlorine residual acceptable? ❑ ❑ ❑ Is the contact chamber free of growth, or sludge buildup? 0 ❑ ❑ ❑ Is there chlorine residual prior to de -chlorination? ❑ ❑ ❑ Comment: Page# 4 DocuSign Envelope ID: 69E32EAA-052A-46AB-BB98-54D79E365AD1 Permit: NCO066796 Owner -Facility: Inspection Date: 07/31/2023 Inspection Type: Leicester Elementary School Compliance Evaluation De -chlorination Yes No NA NE Type of system ? Tablet Is the feed ratio proportional to chlorine amount (1 to 1)? ❑ ❑ 0 ❑ Is storage appropriate for cylinders? 0 ❑ ❑ ❑ # Is de -chlorination substance stored away from chlorine containers? 0 ❑ ❑ ❑ Comment: Are the tablets the proper size and type? ■ ❑ ❑ ❑ Are tablet de -chlorinators operational? 0 ❑ ❑ ❑ Number of tubes in use? 2 Comment: Flow Measurement - Effluent Yes No NA NE # Is flow meter used for reporting? ❑ ❑ 0 ❑ Is flow meter calibrated annually? ❑ ❑ 0 ❑ Is the flow meter operational? ❑ ❑ 0 ❑ (If units are separated) Does the chart recorder match the flow meter? ❑ ❑ MEI Comment: Flow is estimated by the ORC at the weir between the chlorination and de -chlorination chambers. The usual effluent flow is between 1,000 and 3,000 gallons per day during the school year. Effluent Pipe Is right of way to the outfall properly maintained? Are the receiving water free of foam other than trace amounts and other debris? If effluent (diffuser pipes are required) are they operating properly? Yes No NA NE ❑ ■ ❑ ❑ ❑ ❑ ❑ ■ ❑ ❑ ■ ❑ Comment: Effluent pipe could not be found at the time of the inspection. The creek had overgrowth of vegetation along the bank, making it too difficult to find the effluent pipe. See summary for details. Effluent Sampling Yes No NA NE Is composite sampling flow proportional? ❑ ❑ 0 ❑ Is sample collected below all treatment units? M ❑ ❑ ❑ Is proper volume collected? ❑ ❑ 0 ❑ Is the tubing clean? ❑ ❑ 0 ❑ # Is proper temperature set for sample storage (kept at less than or equal to 6.0 ❑ ❑ ■ ❑ degrees Celsius)? Page# 5 DocuSign Envelope ID: 69E32EAA-052A-46AB-BB98-54D79E365AD1 Permit: NC0066796 Owner -Facility: Leicester Elementary School Inspection Date: 07/31/2023 Inspection Type: Compliance Evaluation Effluent Sampling Yes No NA NE Is the facility sampling performed as required by the permit (frequency, sampling type 0 ❑ ❑ ❑ representative)? Comment: Grab samples are collected after the de -chlorination chambers. Standby Power Is automatically activated standby power available? Is the generator tested by interrupting primary power source? Is the generator tested under load? Was generator tested & operational during the inspection? Do the generator(s) have adequate capacity to operate the entire wastewater site? Is there an emergency agreement with a fuel vendor for extended run on back-up power? Is the generator fuel level monitored? Yes No NA NE Comment: No power is needed to operate the facility since it is completely run by gravity. ❑ ❑ ■ ❑ ❑ ❑ ■ ❑ ❑ ❑ ■ ❑ ❑ ❑ ■ ❑ ❑ ❑ ■ ❑ ❑ ❑ ■ ❑ ❑ ❑ ■ ❑ Page# 6 r . . . P. 1t r 5 1' 5 {* ' 'lld+,,r { F. - ' Y ido ,� �� �'r : rr * r • # R 4y � LL '� t � y ' •• r di % w �r ' , - , + - rr• 1 +r •+ IF i AN ' ,� + + ,� i ` r 1, i - � { � 5 _ #a� � +� a Lir' J r, �, � }� i, + � r �#y • rf i 7 Lk Apa. T. r s _ • r��■!� r r 1 a 1 do I ILL Lb _ r. a 1` IL r• } # ti - .ram 4 �,' L '� a r r., '+ y 4� + Apr i Sra77 M' ■ ■�j '• '.i:�+. R' Jrl rvY `'fY �� ■JF k `i p of ob + + }JIIIIII f �r Imo' _ r r'7 rcl ' F� f` #._� r *}{ i' •� y i ry �}"~F +-ram# * L } �{r mart■ ,+r� bibb, !T # ■ft ML %!9 F■ r y• =�' +' •i �-a r4 r' it rt t + �f_3:r '!r ;-* tip} P `_# _;f ■" 4 r Y • y� �tjpd •� r k 4' II rt _ ' � tph ��. y _� . + • ; �� • : i '+ + �:, T# i $16_ i _ .7 f. r �■{l, L ,� r * 'S•S + 'i' �+✓'- - AP JMr •' ~� +' L t i ' { * * T -4 i f • 4 �it.�r.,l � + �' ti . , k+ may Y R `i" ter` "� - - h � r'{� `• �+ { : h� • +; ,'{ rt f .+'�k •_ ; `,..■ '� t' y T 1L}may: # d. y+Lf a�;' `k J`+i ryy r J.--. �Z -s {� - t,T +i+ F !�F - ti •i_41 r PFL 'r - f+ ;.#'''�`-Y •- �!ti T� �L+ r yr 47f dt e4 ! 'I;■• _ �J aL T �i F y �' 'r *+ _ r FP III Alp: r bob _ ' } L JF� _ate i+ / 3 Yt A% F.-r+R; �+ � � r M# "'- ■ ti % {RP ;+ w t 1'*�ti� +air=_ ��'��� `* _ # � y '�1 +�'ti +"�, +� + fir' ' ' rf • a at� a L .ay, • • .- : Slf + R ~ 4�. #w�- ti =ti �yrIFa,_A 4h .. ; • _ !+� _ `y r r L+ x`'+' IL _lw# �� - t .:;F , J ' r• #E r ' IF r' - � �'fk !�� 'ram .�4 � _ • � ■'-'''�_� _ �� 7 ' -, '� ��� j 11 a a r r �� + P L, T NL f T Lp_TT - tiK tit -ram#,+ ■�*� i i' k 1 __t� zJ� f r� r r� ti r w ter: rh JL+T�. ,* - hti �.#! ;.� } '{ J+ f•� �; of '� _ * j �7 �'—• -# �• _ • t �r f ti ` a i fit• •��� - •r i°#• y� }-�''J }' S +jam F +���Yr r yT��1'y'1 ' �• i # ray.:` + ��• 1 # � . 91P TM i .fit �j� a +} +,••F� ~ = f r f*4 JF s- #■_ i� ram, a * { �= i:� 'r-. • �r' -�Y .t +�6r J {40 _ 4 K. gly 411 4b A 91. Z. ` �7r t4 y r - . f{! ;l r - y •'' �. •' T + _ ti• �r�y_ • �'' i. r �,�+��` f r • 'yla r , F � � t • L I' *i �# �i� i/ - + f r !�• ytiti art, t ;i' ':■ - �s IMP b ;y ' : ��•� yr� : • I / r r _ f �, - `~ } + ha 4 F `- • f � AI ^ L� x �r dp�f F R 4 j~ rr �} �IIII� er = r� •� ., �+ �,��Y r: �:�+J`��r�titi� 4 1 + LIP 4 SI! :r + { + :fir; • y _ a_� }. _ ,■f MI t 3 _ •�, - + +t{ tiiR` y, pp �� .*%00 S _ J �, ',# r �� + 11 jr III. 6r., ��a /-` ' •• ` yr { } �L - �.,. motP. , • # { 5 AL dr IF ti 'a MI Lr �� ry'� r a'� ;fit ` � ,� .f ' 4 ' %m OF �f NIP 6A ,�.KL �r y;, "y - P. �% a f , 1� � _ '�ti, +� �• y� ti i, Jr # /y •.} ; I y� , +t�'` }t _ �` Y M1 -Ilk Jw Jig Aw 9j 4c, 91 drr Iw Rr r� -r _. + . y v h � �y■�r t ilrrl'S ' • r�Y* y r y Y � k I * •IP i ' • ' yr•k. - f + M1lor S a MI- tv i r 11#f ' R�4+ r , F� 5 j"t �f ' R 4 ri�� t ' �■`7�a� R •'� + k � #� _FARP 16 t • ti rr - jr * _i �l Zak# Ill 4v 4+ � ■ r � , , � t � v- +'� r•f r �� i' #. �.'ti . � Lr VPI .01 JK_ r . % I hr " + % ' + r , Imo• k ' i+ ` r # a ' + ; f i r a -A �{ 111% Nj Y t 1 = + ids• L ' ' ' ti y i _,� ` rMS. le r L • a r - + 1 f �..: r+ 3 ;+ ?� w, a4 ■AL % k. I +lJ. + - ; �, 4 . ti ,y r ♦ r*i fir.+ '46 * r#5 it L+'4r - #'r ti�k� s �►• ~~ L , �V; +'��' TIL ti.Y, +, ..i- a' 41Nr .E } F , � • j a . rl * r r it * ti ram+ r t a h dlIt i ; ~ F 1 ~# 9 1p 94 IL 4t L ; •• y ij��' ■ w y kL L■