HomeMy WebLinkAboutGW1--04973_Well Construction - GW1_20230807 WELL CONSTRUCTION RECORD(GW-1) For Internal Use Only:
1.Well Contractor Information:
Chris C Russell 14.WATER ZONES '
Well Contractor Name FROM TO DESCRIPTION
3254 A 40 ft- 825 ft-
ft. .ft.
NC Well Contractor Certification Number 15.OUTER CASING(for multi-cased wells)OR LINER(if ap licable)
Russell Well Drilling, Inc. FROM TO DIAMETER THICKNESS MATERIAL
0 ft. 32 ft. 6.25 in. SDSR21 PVC
Company Name
327083 16.INNER CASING OR TUBING(geothermal closed-loop)
2.Well Construction Permit#: FROM TO DIAMETER THICKNESS MATERIAL
List all applicable well construction permits(i.e.U/C,County,State,Variance,etc.) ft. ft. in.
3.Well Use(check well use): ft. ft in.
Water Supply Well: 17.SCREEN
FROM TO DIAMETER SLOT SIZE THICKNESS MATERIAL
❑Agricultural ❑Municipal/Public ft ft. in.
❑Geothermal(Heating/Cooling Supply) l lResidential Water Supply(single) ft. rt in.
❑Industrial/Commercial ❑Residential Water Supply(shared) 18.GROUT
❑Irrigation ❑Wells>100,000 GPD FROM TO MATERIAL EMPLACEMENT METHOD&AMOUNT
Non-Water Supply Well: 0 ft. 20 ft- Grout Poured
❑Monitoring ❑Recovery ft. ft.
Injection Well:
ft. ft.
❑Aquifer Recharge ❑Groundwater Remediation
19.SAND/GRAVEL PACK(if applicable)
❑Aquifer Storage and Recovery ❑Salinity Barrier FROM TO MATERIAL EMPLACEMENT METHOD
❑Aquifer Test ❑Stormwater Drainage ft. ft
❑Experimental Technology OSubsidence Control ft. ft.
❑Geothermal(Closed Loop) ❑Tracer 20.DRILLING LOG(attach additional sheets if necessary)
FROM TO DESCRIPTION(color,hardness,soil/rock type,grain size,etc.)
❑Geothermal(Heating/Cooling Return) ❑Other(explain under#21 Remarks)
0 ft. 29 et Dirt
4.Date Well(s)Completed: 6-1-2023 Well ID# 29 ft 825 ft. Rock -
5a.Well Location: ft. ft. r, '.- �' t�% R_`„
Chris McClemments Sedgewick Homes ft. ft. A AUG 0 s 2023
Facility/Owner Name Facility ID#(if applicable)
ft. ft.
124 Oak Point Ln, StonyPoint, NC 28678 ft. ft. .:. •'• �1:-
Inv;C.I.Z .:1t .�.�
Physical Address,City,and Zip ft. ft. 1;�' j1
Iredell 21.REMARKS ,
County Parcel Identification No.(PIN)
5b.Latitude and longitude in degrees/minutes/seconds or decimal degrees:
(if well field,one lat/long is sufficient) 22.C tification:
35.776.45' N 81 .093.46' W AI��� ,��- 7/28/2023
6.Is(are)the well(s): lPermanent or ❑Temporary tore of Certified Well c ntractor Date
By signing this form,I hereby certifr that the well(s)was(were)constructed in accordance with
7.Is this a repair to an existing well: ❑Yes or I'JNo 15A NCAC 02C.0100 or 15A NCAC 02C.0200 Well Construction Standards and that a copy
If this is a repair,fill out known well construction information and explain the nature of the of this record has been provided to the well owner.
repair under#21 remarks section or on the back of this form.
23.Site diagram or additional well details:
8.For Geoprobe/DPT or Closed-Loop Geothermal Wells having the same You may use the back of this page to provide additional well construction info
construction,only 1 GW-1 is needed. Indicate TOTAL NUMBER of wells (add'See Over'in Remarks Box).You may also attach additional pages if necessary.
drilled: 24.SUBMITTAL INSTRUCTIONS
9.Total well depth below land surface: 825 (ft) Submit this GW-1 within 30 days of well completion per the following:
For multiple wells list all depths if different(example-3@200'and 2@l00')
4024a. For All Wells: Original form to Division of Water Resources (DWR),
10.Static water level below top of casing: (ft) Information Processing Unit,1617 MSC,Raleigh,NC 27699-1617
If water level is above casing,use"+"
11.Borehole diameter: 6.25 (in.) 24b.For Injection Wells:Copy to DWR,Underground Injection Control(IUC)
Program,1636 MSC,Raleigh,NC 27699-1636
12.Well construction method: Air Drilled
24c.For Water Supply and Open-Loop Geothermal Return Wells:Copy to the
(i.e.auger,rotary,cable,direct push,etc.) county environmental health department of the county where installed
FOR WATER SUPPLY WELLS ONLY: 24d.For Water Wells producing over 100,000 GPD:Copy to DWR,CCPCUA
13a.Yield(gpm) 2 Method of test:Air
Permit Program,1611 MSC,Raleigh,NC 27699-1611
13b.Disinfection type: HTC Amount: 2 1/3 cups
Form GW-1 North Carolina Department of Environmental Quality-Division of Water Resources Revised 6-6-2018