HomeMy WebLinkAboutWQ0002284_Notice of Violation_20000913EV State of North Carolina Department of Environment and Natural Resources Division of Water Quality Washington Regional Office James B. Hunt, Jr., Governor Bill Holman, Secretary Kerr T. Stevens, Director NCDENR NORTH CAROuNA DEPARTMENT oR ENVIRONMENT AND NAruRAL RESOURCES September 13, 2000 CERTIFIED MAIL Return Receipt Requested Mr. C. Wayne Kinser Outer Banks Beach Club, Inc. Post Office Box 6319 Asheville, North Carolina 28816 Subject: NOTICE OF VIOLATION Non -Discharge Compliance Inspection Outer Banks Beach Club — Kill Devil Hills Wastewater Rotary Distributor Facilities Permit No. WQ0002829 Dare County Dear Mr. Kinser: Enclosed please find a copy of the Non -Discharge Compliance Inspection Report from the inspection conducted on July 10, 2000. The Compliance Inspection was conducted by Ms. Kim Cole of the Washington Regional Office. Mr. Bill Freed's assistance during the inspection was helpful and is greatly appreciated. The treatment facility was found to be in violation of permit WQ0002829 for the following: 1) Review of the self -monitoring reports for July 1999 through July 2000 revealed violations of the following monthly average limits: Date Parameter RMgrted Value/Unit MonthLimit Value/Unit November 1999 Fecal Coliform 30 colonies/100 mL 14 colonies/100 mL June 2000 NH3 17.20 m 4 m June 2000 NH3 17.24 m 4 m July 2000 Fecal Coliform 15 colonies/ 100 mL 14 colonies/ 100 mL 2) Review of the self monitoring reports for July 1999 through July 2000 revealed violations of the following daily maximum limits: Month Parameter Re rted Value/Unit 2aily Max Limit Value/Unit December 9 1999 BOD 16 m 15 m June 16 2000 NH3 8.56 m 6 June 16 2000 NH3 &48 m 6 June 22 2000 NH3 25.92 m 6 m June 22 2000 NH3 25.92 m 6 June 22,2000 Fecal Coliform 430 colonies/100 mL 43 colonies/100 mL June 22 2000 Fecal Coliform .64 colonies/100 mL 43 colonies/100 mL July 13 2000 1 NH3 6.13m 6 943 Washington Square Mall, Washington, North Carolina 27889 Telephone (252) 946-6481 FAX (252) 975-3716 An Equal Opportunity Affirmative Action Employer 50% recycled/] 0% post -consumer paper 3) "TNTC" was reported on the July NDMR form for July 27, 1999 Fecal Coliform results. The Division of Water Quality Regulation 15A NCAC 2B .0506 (b) (3) (1) states that "Only numeric values will be accepted in reporting results of fecal coliform testing. The reporting of "too numerous to count" TNTC as a value will constitute a violation." 4) Permit No. WQ0014306 requires composite samples for BOD5, NH3, and TSS. The definition of composite sample is found on page I of North Carolina Administrative Code 15A: 02B .500 (copy enclosed). Unless effluent flows vary less than 15 percent and the method has been approved by the director, composite samples must be flow proportional using one of the following methods: (a) Continuous (b) Constant time/variable volume (c) Variable time/constant volume Please notify the Washington Regional Office in writing within 15 working days how the subject facility presently collects BOD5, NH3, and TSS. 5) Review of records reveals that the influent flowmeter for the Aeromod plant was not operational during the months of October and November 1999 and January, February, and March 2000. 6) At the time of the inspection, the effluent was unacceptable. "'The effluent was not clear and free of solids. The steel plant was at 60.5% of its treatment capacity and the Aeromod plant was at 40.1% capacity for July 2000 and should produce a high quality effluent. These plants should be inspected closely to determine the cause of this unacceptable effluent. Other items observed during the site inspection: • All aeration basins had a good healthy color at the time of inspection. • The rotary distributor fields were well maintained with no evidence of ponding or excessive vegetative growth. • Several of the rotary distributors were not operational at the time of the inspection and should be repaired. You should carefully review these violations and deficiencies and respond in writing to this office within fifteen (1.5) working day of receipt of this letter. You should address the causes of noncompliance and all actions taken to prevent the recurrence of similar situations. Future compliance will be monitored closely and continued noncompliance may result in an enforcement action. If you should have any questions, please do not hesitate to contact Kim Cole at (252) 946-6481 ext. 317. Sincerely, 00'_� Ur_ -'XI Aa� Jim MulliganJ Water Quality Regional Supervisor Washington Region Division of Water Quality Cc: Mr. Bill Freed, Enviro-Tech, Inc., Post Office Box 511 Corolla, NC 27927 WQ Central Files WaR_O aR0 Enforcement NDCEU State of North Carolina Department of Environment and Natural Resources Division of Water Quality James B. Hunt, Jr., Governor Bill Holman, Secretary Kerr T. Stevens, Director NCDENR - EW:;OhNGfTANC NIW.FL4LF;r_r1rIJRCCL Non -Discharge Compliance Inspection WQ Permit Number W00002829 County DARE Permittee OUTER BNKS BCH CLB-KILL DEVIL Npdes Number(s) Issuance Date 1013/97 Expiration Date 9/30/2002 Soc Issuance Date Soc ExpirationDate Permittee Contact C. WAYNE KINSER Phone Permittee Contact ORC Certification # ORC Name William G. Freed Phone ORC (252) 453-9284 24hr Contact Name William G. Freed Phone 24hr (252) 453-9284 Reason For Inspection (Select One) 10 Routine p Complaint Q Follow -Up p Other... Type Of Inspection (Select One) 10 Collection System 0 Spray Irrigation Q Residual Inspection Summary Inspector's Name Phone Inspector Inspection Date Kimberly H. Cole Y, CA 9/13Inspectors Title Environmental Specialist II (252) 946-6481 / Q Fax Inspector (252) 946-9215 July 10, 2000 page 1 Non Discharge Compliance Spray Irrigation Inspection Permittee OUTER BNKS BCH CLB4ULL Permit Number FJMk2829 Inspection Date Puly 10, 2000 Tvae _ O REUSE (Golf Courses) Q ACTIVATED SLUDGE SPRAY, HR O INFILTRATION SYSTEM O RECYCLE/REUSE O ACTIVATED SLUDGE DRIP, LR . O LAGOON SPRAY, LR O SINGLE FAMILY SPRAY, LR O ACTIVATED SLUDGE SPRAY, LR O SINGLE FAMILY DRIP Treatment Are Treatment facilities consistent with those outlined in the current permit? * Yes O No Do all treatment units appear to be operational, if no note below?* Yes O No List any action items necessary per unit. Construction has not begun on the additional 200,000 GPD system. Lagoons Primary (check any unit present) ❑ Influent structure, (free of obstructions) ❑ Banks/berms (are there signs of seepage or erosion) ❑ Vegetation, (is there excessive vegetation on the lagoon bank that makes Inspection difficult) ❑ Liner (if visible is it tact) ❑ Baffles/curtains, (in need of repair) ❑ Freeboard, (>2 feet from overtopping) ❑ Evidence of overflow, (vegetation discolored or laying down/broken) 0 Unusual color, (very black, textile colors) ❑ Foam,( are antifoam agents used) ❑ Floating mats (sludge, plants) ❑ Excessive solids buildup (from bottom) ❑ If present are aerators/mNers operational ❑ Effluent Structure (free of obstructions. easily accessible) , Secondary (check any unit present) ❑ Influent structure, (free of obstructions) ❑ Banks/berms (are there signs of seepage or erosion) ❑ Vegetation, (is there excessive vegetation on the lagoon bank that makes Inspection difficult) ❑ Liner (If visible is it tact) ❑ Baffles/curtains, (in need of repair) ❑ Freeboard, (>2 feet from overtopping) ❑ Evidence of overflow, (vegetation discolored or laying down/broken) ❑ Unusual color, (very black, textile colors) ❑ Foam,( are antifoam agents used) ❑ Floating mats (sludge, plants) ❑ Excessive solids buildup (from bottom) ❑ If present are aerators/mixers operational ❑ Effluent Structure (free of obstructions. easily accessible) Influent pump station Are all pumps present? * Yes O No Bypass line or structure 'present 10 Yes* No rump 9 page 2 Non Discharge Compliance Spray Irrigation Inspection Permittee PUTER BNKS BCH CLB-KILL Permit Number PJ&k2829 Inspection Date Puly 10, 2000 Barscreen maintained QQ Yes Q No Free of excessive debris* Yes Q No Bars evenly spaced 0 Yes Q No Bars excessively corroded 10 Yes j No Aeration Basin aeration pattern even across surface of unit QQ Yes Q No Easily accessed 0 Yes Q No Clarifiers weirs level Q Yes Q. No Scum rack operational -- — - - --- QQ Yes Q No Easily accessed 0 Yes Q No Return Pumps in, place QQ Yes Q No Operational* Yes Q No Fllters media present Air scour operational Clear well free of excessive solids 14) Yes Q No Yes Q No Q Yes No Sludge Storage/ Treatment Aeration operational * Yes Q No Good pattern * Yes Q No If required are Sanitary 7s" present in tankage? 10 Yes Q No Disinfection If gas Is storage safe 0 Yes Q No Is dual feed system 10 Yes Q No How do you know it is working QQ Yes Q No ff tablets: Are tablets present? 10 Yes Q No Storage ❑ Lagoon ❑ AST ❑ UST ❑ Septic Tank ❑ Drying Beds ❑ Concrete Storage Pads Number of months storage? Spill control plan on site? 10 Yes Q No ff Applicable: Is lagoon.lined? 10 Yes Q No Above Ground Tank ❑ Aerated ❑ Mixed Aerated Hp: Mixed Hp: Under Ground Tank JE1 Aerated ❑ Mixed Aerated Hp: Mixed Hp: page 3 Non Discharge. Compliance Spray Irrigation Inspection Permittee LITER BNKS BCH CLB4ULL Permit Number 2829 Inspection Date Puly 10, 2000 Record KeeDin Copy of current permit available?O Yes Q No Are monitoring reports present NDMR * Yes Q No NDAR * Yes Q No Are operational logs present? QQ Yes Q No Are lab sheets availiable for review? Qi Yes Q No Do lab sheets support data represented on NDMR or NDAR? Yes Q No Are annual soil reports available? 10 Yes Q No Are Operation and Manintance records present?O Yes Q No l Are Operation and Manintance records Complete?O Yes Q No Has permittee received any public compliants in the last 12 months?Q Yes Q No Disposal Buffers Adequate? Qi Yes Q No Cover Crop Type Specified in Permit? 0 Yes Q No Site Condition adequate (improvement)? QQ Yes Q No Signs of runoff / ponding? Q Yes 0 No Is the average specified in the permit being utilized?O Yes Q No Is application equipment present and operational? Q Yes 0 No .Are there any limiting slopes on disposal field? 10 Yes 0 No Are monitoring wells called for in permit? * Yes Q No Access restrictions and / or signage?O Yes Q No