Loading...
HomeMy WebLinkAboutWQ0015931_Final Permit_20230817ROY COOPER Governor ELIZABETH S. BISER Secretary RICHARD E. ROGERS, JR. Director CHARLES B. LONG — BACK-UP ORC TNGC CHARLOTTE LLC 120 TRUMP SQUARE MOORESVILLE, NORTH CAROLINA 28117 Dear Mr. Long, NORTH CAROLINA Environmental Quality August 17, 2023 Subject: Permit No. WQ0015931 Trump National Golf Club Charlotte WWTP Reclaimed Water Generation and Dedicated Utilization System Iredell County In response to your permit major modification and renewal request received on August 10, 2022, and subsequent additional information received on December 28, 2022, April 3, 2023, and June 22, 2023, we are forwarding herewith Permit No. WQ0015931 dated August 17, 2023, to TNGC Charlotte LLC for the continued operation of the existing wastewater collection and dedicated utilization facilities, the continued operation and subsequent abandonment of the existing reclaimed water generation facilities, and the construction and operation of the proposed reclaimed water generation facilities. Modifications to the subject permit are as follows: ➢ The Division has approved the replacement of the existing 25,000 gallon per day (GPD) reclaimed water generation facility with a 10,000 GPD reclaimed water generation facility consisting of a flow equalization tank, a primary filter tank, a two -stage polishing filter tank, and an ultraviolet (UV) disinfection system. This permit is effective from the date of issuance through June 30, 2030, replace Permit No. WQ0015931 issued on April 9, 2018, and is subject to the conditions and limitations therein. The Permittee shall submit a renewal application no later than January 1, 2030. Please pay attention to the monitoring requirements listed in Attachments A and B for they may differ from the previous permit issuance. Failure to establish an adequate system for collecting and maintaining the required operational information may result in future non-compliance. D � North Carolina Department of Environmental Quality i Division of Water Resources 512 North Salisbury Street 11617 Mail Service Center I Raleigh, North Carolina 27699-1617 NORTH CAROLINA '.'roMMm 0­; /I 919,707,9000 Mr. Charles B. Long August 17, 2023 Page 2 of 3 The Division has removed the following permit conditions since the last permit issuance dated April 9, 2018: ➢ Old Condition IL14 —The Division has removed this condition because the Permittee owns all of the reclaimed water irrigation sites. ➢ Old Condition IIL2.b — The Division has removed this condition. ➢ Old Condition IIL9 — The Division has removed this condition because it is in Condition II1.18. ➢ Old Condition VL2 — The Division has removed this condition because this permit is not voidable. The following permit conditions and attachment are new or modified since the last permit issuance dated April 9, 2018: ➢ Condition I.1 — The Permittee shall submit an Engineering Certification upon completion of construction and prior to operation of the permitted modifications. The Permittee shall submit the Engineering Certification via the Non -Discharge online portal. ➢ Condition L2 — The Permittee shall notify the Mooresville Regional Office, telephone number (704) 663-1699, at least two business days in advance of the initial operation of the constructed modifications so that the Division can conduct a startup inspection. ➢ Condition L3 — Prior to the operation of the reclaimed water modified facilities, the Permittee shall submit an amended Operation and Maintenance Plan. The Permittee shall submit the amended Operation and Maintenance Plan via the Non -Discharge online portal. ➢ Condition IL14 — The Division has modified Old Condition IL8 to decrease the horizontal distance reclaimed water distribution lines can be located from water lines from 10 feet to 5 feet. ➢ Condition IL15 — The Division has modified Old Condition IL9 to decrease the distance reclaimed water distribution lines can be located from wells from 100 feet to 50 feet. The Division has also removed the phrase "or 50 feet from a public well". ➢ Condition IL 16 — The Division has modified Old Condition IL 10 to reference 15A NCAC 02T .0305 in place of providing sewer line separation distances. ➢ Condition IL 17 — The Division has modified Old Condition IL 15 to correspond to the setbacks at the time of the original permitting or the most recent major modification for each irrigation site and storage/treatment unit. ➢ Condition 111.18 — The Permittee shall test and calibrate metering equipment annually. ➢ Condition IIL20 — The Permittee shall provide continuous online monitoring and recording for turbidity or particle count and flow prior to storage, distribution, or utilization of reclaimed water. ➢ Condition IV.5.f — The Division has modified Old Condition IV.5 to include continuous monthly and year-to-date loadings for any non -hydraulic parameter specifically limited in Attachment B in the reclaimed water irrigation records. Mr. Charles B. Long August 17, 2023 Page 3 of 3 ➢ Condition IV.9.b — The Division has modified Old Condition IV.8 to include the date of irrigation equipment calibration in the maintenance log. ➢ Condition IV. IO.c — The Division has modified Old Condition IV.I I to include any facility failure resulting in a discharge to surface waters in the noncompliance notification. ➢ Condition VL9 — Unless the Division Director grants a variance, the Division shall not renew this permit if the Permittee or any affiliation has not paid an annual fee pursuant to 15A NCAC 02T .0105(e)(2). ➢ Attachment A — The Division has removed the Total Residual Chlorine effluent parameter because the Permittee is abandoning the existing backup tablet chlorinator. The Division has also reduced the sampling frequency for BOD, Fecal Coliform, Ammonia, Total Kjeldahl Nitrogen, Nitrate, Total Nitrogen, Total Phosphorus, and Total Suspended Solids from Monthly to 4 x Year. This permit can be contested as provided in Chapter 150B of the North Carolina General Statutes by filing a Petition for a Contested Case Hearing (Petition) with the North Carolina Office of Administrative Hearings (OAH) within 30 calendar days. Requirements for filing a Petition are set forth in Chapter 150B of the North Carolina General Statutes and Title 26 of the North Carolina Administrative Code. Those interested in filing may access additional information regarding the requirements for filing a Petition and Petition forms at the OAH website or by calling the OAH Clerk's Office at (919) 431-3000. A parry filing a Petition shall serve a copy of the Petition on the Department of Environmental Quality's Office of General Counsel at 1601 Mail Service Center, Raleigh, NC 27699-1601. If the parry filing the Petition is not the Permittee, then the party shall also serve the Permittee pursuant to G.S. 15013-23(a). Included with this permit are Division -approved plans and specifications. If you need additional information concerning this permit, please contact Zachary Mega at (919) 707-3658 or zachary.me ag &deq.nc.gov. Sincerely, DocuSigned by: Naf l� oun tt,l Tu"Wo D1043082680C483... Richard E. Rogers, Jr., Director Division of Water Resources cc: Iredell County Health Department (Electronic Copy) Mooresville Regional Office, Water Quality Regional Operations Section (Electronic Copy) Donald L. Munday, PE — Piedmont Design Associates, P.A. (Electronic Copy) Operator Certification Program (Electronic Copy) Laserfiche File (Electronic Copy) Digital Permit Archive (Electronic Copy) THIS PAGE BLANK NORTH CAROLINA ENVIRONMENTAL MANAGEMENT COMMISSION DEPARTMENT OF ENVIRONMENTAL QUALITY RALEIGH RECLAIMED WATER GENERATION AND DEDICATED UTILIZATION SYSTEM PERMIT Pursuant to the provisions of Article 21 of Chapter 143, General Statutes of North Carolina as amended, and other applicable Laws, Rules, and Regulations PERMISSION IS HEREBY GRANTED TO TNGC Charlotte LLC Iredell County FOR THE operation of a 10,000 gallon per day (GPD) wastewater collection, reclaimed water generation, and dedicated utilization facility consisting of the: continued operation of a wastewater collection system consisting of. approximately 2,250 linear feet (LF) of 8-inch gravity sewer; a 70 gallon per minute (GPM) pump station with duplex pumps and audible/visual high-water alarms; approximately 1,905 LF of 4-inch force main; and all associated piping, valves, controls, and appurtenances; the continued operation and subsequent abandonment of a 25,000 GPD reclaimed water generation facility consisting of. a screening device; a flow splitter; a 6,250 gallon flow equalization basin with two 35 GPM pumps; two 12,500 gallon aeration basins served by two 165 cubic feet per minute (CFM) blowers; two 2,167 gallon clarifiers; an ultraviolet (UV) disinfection system with a backup tablet chlorinator; a 6,250 gallon sludge holding tank; an effluent flow meter; two 15 square foot (fl2) tertiary filters; a 4,800 gallon clearwell with two 225 GPM backwash pumps; a 4,800 gallon backwash return tank with two 26 GPM pumps; a 15 CFM air scour blower; a continuous in -line turbidimeter; and all associated piping, valves, controls, and appurtenances; the construction and operation of a 10,000 GPD reclaimed water generation facility consisting of. a 15,128 gallon flow equalization tank with two 30 GPM pumps; a 15,128 gallon primary filter tank served by three 75 GPM pumps dosing a textile media filter with audible/visual high-water alarms; a two -stage 15,128 gallon polishing filter tank served by one 75 GPM pump mixing a submerged polyethylene media and two 75 GPM pumps dosing a textile media filter with audible/visual high-water alarms; a UV disinfection system consisting of two 40 GPM units in series; a continuous in -line turbidimeter; an effluent flow meter; two 30 GPM discharge pumps; and all associated piping, valves, controls, and appurtenances; the continued operation of. a 125,000 gallon five-day upset pond; a 60 GPM pump station with duplex pumps and audible/visual high-water alarms; a 1,739,610 gallon wet weather storage pond with two 80 GPM irrigation pumps; and all associated piping, valves, controls, and appurtenances; and the continued operation of a dedicated reclaimed water utilization facility consisting of. a 2.10 acre drip irrigation area with six zones and nineteen 200-foot drip lines; a 150 GPM pump rated at 267 feet of total dynamic head (TDH); a 13.39 acre spray irrigation area with 17 zones and a total of 49 spray heads; a soil moisture sensor; and all associated piping, valves, controls, and appurtenances WQ0015931 Version 5.0 Shell Version 230516 Page 1 of 12 to serve the Trump National Golf Club Charlotte WWTP, with no discharge of wastes to surface waters, pursuant to the application received on August 10, 2022, subsequent additional information received on December 28, 2022, April 3, 2023, and June 22, 2023, and in conformity with the Division -approved plans and specifications considered a part of this permit. This permit is effective from the date of issuance through June 30, 2030, shall replace Permit No. WQ0015931 issued on April 9, 2018, and is subject to the following conditions and limitations: I. SCHEDULES Upon completion of construction and prior to operation of the permitted modifications, the Permittee shall submit an engineering certification from a North Carolina licensed Professional Engineer certifying that the permitted facility has been constructed pursuant to G.S. 143-215.1, Administrative Code Title 15A Subchapter 02U, this permit, and the Division -approved plans and specifications. For phased and partially certified facilities, the Permittee shall retain the responsibility to track further construction approved under this permit and shall provide a final engineering certification upon project completion. The Permittee shall submit the Engineering Certification via the Non -Discharge online portal. [15A NCAC 02T .0116(a), 02U .01161 2. The Permittee shall notify the Mooresville Regional Office, telephone number (704) 663-1699, at least two business days in advance of the initial operation of the constructed modifications so that the Division can conduct a startup inspection. [ 15A NCAC 02T .0108(b)(1)(A), 02U .0108] 3. Prior to the operation of the reclaimed water modified facilities, the Permittee shall submit an amended Operation and Maintenance Plan. The Permittee shall submit the amended Operation and Maintenance Plan via the Non -Discharge online portal_ [15A NCAC 02T .0108(b)(1)(B), 02U .0108, 02U .0801(a)] 4. If the permitted facilities change ownership or the Permittee changes its name, the Permittee shall submit a permit modification request on Division -approved forms within 90 days of the change of ownership. The Permittee shall comply with all terms and conditions of this permit until the Division transfers the permit to the successor -owner. [G.S. 143-215.1(d3)] 5. The Permittee shall request renewal of this permit on Division -approved forms no later than January 1, 2030. [15A NCAC 02T .0105(b), 02T .0109, 02U .0105, 02U .0109] IL PERFORMANCE STANDARDS The Permittee shall operate and maintain the subject reclaimed water generation and dedicated utilization facilities so there is no discharge to surface waters, nor any contravention of groundwater or surface water standards. In the event the facilities do not perform as designed, including the creation of nuisance conditions due to improper operation and maintenance, or failure of the utilization areas to assimilate the reclaimed water, the Permittee shall take immediate corrective actions, including Division -required actions, such as the construction of additional or replacement reclaimed water generation and dedicated utilization facilities. [15A NCAC 02T .0108(b)(1)(A), 02U .0108] 2. This permit shall not relieve the Permittee of its responsibility for contravention of groundwater or surface water standards resulting from the operation of this facility. [15A NCAC 02T .0108(b)(1)(A), 02U .0108] WQ0015931 Version 5.0 Shell Version 230516 Page 2 of 12 3. The Permittee shall operate and maintain the permitted wastewater collection facilities pursuant to the following criteria: a. The Permittee shall operate and maintain the collection system to prevent discharge to land or surface waters and to prevent contravention of groundwater or surface water standards. b. The Permittee shall develop and maintain a map of the collection system. c. The Permittee shall develop, implement, and maintain an operation and maintenance plan. d. The Permittee shall inspect pump stations not connected to a telemetry system every day unless the Division approves otherwise. The Permittee shall inspect pump stations connected to a telemetry system once per week. e. The Permittee shall inspect high -priority sewers once every six months. f. The Permittee shall conduct a general observation of the entire collection system once per year. g. The Permittee shall report overflows and bypasses to the Mooresville Regional Office pursuant to 15A NCAC 02B .0506(a) and the Permittee shall provide public notice as required by G.S. 143- 215.1C. h. The Permittee shall develop, implement, and maintain a grease control program. i. The Permittee shall maintain rights -of -way and easements. j. The Permittee shall maintain documentation of compliance with the above requirements for three years, except for the map, which the Permittee shall maintain for the life of the system. [ 15A NCAC 02T .0403(a)] 4. Reclaimed water quality shall not exceed the limitations specified in Attachment A. [15A NCAC 02U .0301] 5. The Permittee shall not utilize generated reclaimed water in exceedance of the hydraulic and agronomic rates specified in Attachment B. [15A NCAC 02U .0401(a)] 6. The Permittee shall tag or label all reclaimed water valves, storage facilities, and outlets to warn the public or employees that the reclaimed water is not for drinking. [ 15A NCAC 02U .0403(b)] 7. The Permittee shall color -code, tape, or otherwise mark all reclaimed water piping, valves, outlets, and other appurtenances to identify the source of the water as reclaimed water as follows: a. All reclaimed water piping and appurtenances shall be either colored purple (Pantone 522 or equivalent) and embossed or integrally stamped or marked "CAUTION: RECLAIMED WATER - DO NOT DRINK" or installed with a purple (Pantone 522 or equivalent) identification tape or polyethylene vinyl wrap. The warning shall be on opposite sides of the pipe and repeated every three feet or less. b. Identification tape shall be at least three inches wide and have white or black lettering on a purple (Pantone 522 or equivalent) field stating "CAUTION: RECLAIMED WATER - DO NOT DRINK." The Permittee shall install identification tape on top of reclaimed water pipelines fastened at least every 10 feet to each pipe length and run continuously the entire length of the pipe. c. The Permittee shall tape or otherwise identify existing underground distribution systems retrofitted for conveying reclaimed water as described in Paragraphs a. and b. above. The Permittee shall perform this identification within 10 feet of any potable water supply line or sanitary sewer line crossing a reclaimed water line. The Permittee does not need to perform this identification for the entire length of the distribution system. [ 15A NCAC 02U .0403(c)1 8. The Permittee shall secure all reclaimed water valves and outlets such that only Permittee-authorized personnel can operate them. [15A NCAC 02U .0403(d)] WQ0015931 Version 5.0 Shell Version 230516 Page 3 of 12 9. The Permittee shall place hose bibs in locked, below -grade vaults and label them non -potable. The Permittee may place hose bibs above ground and label them non -potable if the hose bibs require a tool to operate. [15A NCAC 02U .0403(e)] 10. There shall be no direct cross -connections between the reclaimed water and potable water systems unless such connection is Department -approved pursuant to 15A NCAC 18C .0406. [15A NCAC 02U .0403 11. For reclaimed water irrigation fields permitted prior to September 1, 2006, the Division has established the compliance and review boundaries at the property boundary. Any exceedance of groundwater standards at or beyond the compliance boundary shall require the Permittee to take corrective action. The Division shall note any Division -approved relocation of the compliance boundary in Attachment B. The Division shall consider multiple contiguous properties under common ownership and permitted for use as a disposal system as a single property regarding the determination of a compliance boundary. [15A NCAC 02H .0219(k)(1)(C)(i)(III), 02L .0106(e), 02L .0107(c), 02L .0107(fl, 02T .0105(h)1 12. The Permittee shall notify the Division of any sale or transfer of property affecting a compliance boundary (i.e., parcel subdivision). [15A NCAC 02L .0107(1)] 13. The Permittee or any landowner who owns land within the compliance boundary shall not construct any water supply wells within the compliance boundary. [ 15A NCAC 02L .0107(i)] 14. Reclaimed water distribution lines shall be at least five feet horizontally from and 18 inches below any water line if practicable. If these separation distances cannot be met, the piping and integrity testing procedures shall meet water main standards pursuant to 15A NCAC 18C. [ 15A NCAC 02U .0403(a), 02U .0403(h)] 15. Reclaimed water distribution lines shall not be less than 50 feet from a well unless the piping and integrity testing procedures meet water main standards pursuant to 15A NCAC 18C, but in no case shall they be less than 25 feet from a private well. [15A NCAC 02U .0403(a), 02U .0403(i)] 16. Reclaimed water distribution lines shall meet the separation distances to sewer lines pursuant to 15A NCAC 02T .0305. [15A NCAC 02U .0403(g), 02U .0403(j)] 17. The Permittee shall operate and maintain the permitted facilities pursuant to the following setbacks: a. The Division originally permitted the reclaimed water irrigation sites on February 9,1999, and May 17, 2005, with applications received on September 28, 1998, and April 21, 2005, respectively. The setbacks for spray and drip reclaimed water irrigation sites originally permitted or modified with an application received from June 1, 1996, through August 31, 2006, are as follows (all distances in feet): i. Surface waters classified SA: 100 ii. Surface waters not classified SA: 25 In. Each water supply well: 100 iv. Each non -potable well: 10 v. Each swimming pool: 25 [15A NCAC 02H .0219(k)(1)(C)(i)] WQ0015931 Version 5.0 Shell Version 230516 Page 4 of 12 b. The Division originally permitted the 125,000 gallon five-day upset pond and the 1,739,610 gallon wet weather storage pond on February 9, 1999, with an application received on September 28, 1998. The setbacks for treatment and storage units originally permitted or modified with an application received from June 1, 1996, through August 31, 2006, are as follows (all distances in feet): I. Each habitable residence or place of assembly under separate ownership: 100, ii. Each private or public water supply source: 100 iii. Surface waters: 50 iv. Each well with exception of monitoring wells: 100 v. Each property line: 50 vi. Nitrification field: 20 ' Habitable residences or places of assembly under separate ownership constructed after the Division originally permitted or subsequently modified the facilities are exempt from this setback. 2 Setbacks to property lines are not applicable when the Permittee, or the entity from which the Permittee is leasing, owns both parcels separated by the property line. [ 15A NCAC 02H .0219(i)(5)] c. The Division permitted modifications to the treatment units on August 17, 2023, with an application received on August 10, 2022. The setbacks for treatment and storage units originally permitted or modified with an application received on or after September 1, 2018, are as follows (all distances in feet): I. Each habitable residence or place of assembly under separate ownership: 1001 ii. Each private or public water supply source: 100 iii. Surface waters: 50 iv. Each well with exception of monitoring wells: 100 v. Each property line: 50 2 ' Habitable residences or places of assembly under separate ownership constructed after the Division originally permitted or subsequently modified the facilities are exempt from this setback. 2 Setbacks to property lines are not applicable when the Permittee, or the entity from which the Permittee is leasing, owns both parcels separated by the property line. [15A NCAC 02T .0506(b), 02U .0701(a), 02U .0701(h), 02U .0701(i)] WQ0015931 Version 5.0 Shell Version 230516 Page 5 of 12 III. OPERATION AND MAINTENANCE 1. The Permittee shall operate and maintain the subject facilities as anon -discharge system. [15A NCAC 02U .0101] 2. The Permittee shall maintain an Operation and Maintenance Plan, which shall include: a. A description of the operation of the system in sufficient detail to show what operations are necessary for the system to function and who shall conduct the operations. b. A description of the anticipated maintenance of the system. c. Provisions for safety measures, including restriction of access to the site and equipment. d. Spill control provisions that include response to upsets and bypasses, including control, containment, and remediation; and contact information for personnel, emergency responders, and regulatory agencies. f 15A NCAC 02U .0801(a)] 3. Upon the Water Pollution Control System Operators Certification Commission's (WPCSOCC) classification of the subject non -discharge facilities, the Permittee shall designate and employ a certified Operator in Responsible Charge (ORC), and one or more certified operators as Back-up ORCs. The ORC or its Back-up shall operate and visit the facilities as required pursuant to 15A NCAC 08G .0204 and 08G .0205. [ 15A NCAC 02T .0117, 02U .0117] 4. An operator certified by the Water Pollution Control System Operators Certification Commission (WPCSOCC) of a grade equivalent or greater than the facility classification shall be on call 24 hours per day. [ 15A NCAC 02U .0401(e)] 5. The Permittee shall maintain a year-round vegetative cover on the irrigation area such that crop health is optimal and allows even reclaimed water distribution and inspection of the irrigation system. [15A NCAC 02U .0801(b)] 6. The Permittee shall take measures to prevent reclaimed water ponding in or runoff from the irrigation area. [ 15A NCAC 02U .0801(c)1 7. The Permittee shall not irrigate generated reclaimed water during inclement weather or when the soil is in a condition that will cause ponding or runoff. [ 15A NCAC 02U .0401(k)] 8. The Permittee shall test and calibrate the irrigation equipment once per permit cycle. [ 15A NCAC 02U .0801 d 9. The Permittee shall only irrigate reclaimed water generated from the Trump National Golf Club Charlotte WWTP onto the sites listed in Attachment B. [ 15A NCAC 02U .0101] 10. The Permittee shall not allow vehicles or heavy machinery on the irrigation area, except during equipment installation or maintenance activities. [ 15A NCAC 02U .0801(e)1 11. The Permittee shall prohibit public access to the reclaimed water generation and storage facilities. [15A NCAC 02T .0108(b)(1)(A), 02U .0108] 12. The Permittee shall control public access to reclaimed water utilization sites during active site use. [15A NCAC 02U .0501(a)(2)] 13. The Permittee shall dispose of or utilize generated residuals in a Division -approved manner. [15A NCAC 02T .1101, 02U .08021. 14. The Permittee shall not divert or bypass untreated or partially treated reclaimed water from the subject facilities. [15A NCAC 02U .0402(g)] WQ0015931 Version 5.0 Shell Version 230516 Page 6 of 12 15. The Permittee shall maintain a freeboard of not less than two feet in the 125,000 gallon five-day upset pond and the 1,739,610 gallon wet weather storage pond. [15A NCAC 02U .0401(h)] 16. The Permittee shall provide gauges to monitor freeboard levels in the 125,000 gallon five-day upset pond and the 1,739,610 gallon wet weather storage pond. These gauges shall have readily visible permanent markings, at inch or tenth of foot increments, indicating the following elevations: the maximum liquid level at the top of the temporary liquid storage volume, the minimum liquid level at the bottom of the temporary liquid storage volume, and the lowest point on top of the dam. [ 15A NCAC 02U .0801(fl] 17. The Permittee shall establish and maintain a protective vegetative cover on all berms, pipe runs, erosion control areas, surface water diversions, and earthen embankments (i.e., the outside toe of the embankment to the maximum allowable temporary storage elevation on the inside of the embankment). The Permittee shall remove all trees, shrubs, and other woody vegetation from earthen dikes and embankments. The Permittee shall keep all earthen embankments mowed or otherwise controlled and accessible. [15A NCAC 02U .0801(a)] 18. The Permittee shall test and calibrate metering equipment annually. [15A NCAC 02U .0801(d)] 19. The Permittee shall provide an automatically activated standby power source or other means to prevent improperly treated wastewater from entering the storage, distribution, or utilization system. If the Permittee employs a generator as an alternate power supply, the Permittee shall test it weekly. [15A NCAC 02U .0401(d)] 20. The Permittee shall provide continuous online monitoring and recording for turbidity or particle count and flow prior to storage, distribution, or utilization of reclaimed water. [ 15A NCAC 02U .0401(b)] 21. If the generated reclaimed water exceeds 10 nephelometric turbidity units (NTUs) or the pathogen limits in Attachment A, the Permittee shall route all generated reclaimed water to the 125,000 gallon five-day upset pond until the Permittee corrects all problems associated with the reclaimed water generation system. The Permittee shall pump all water in the 125,000 gallon five-day upset pond back to the treatment plant headworks for re -treatment or treat the water in the 125,000 gallon five-day upset pond prior to utilization. [ 15A NCAC 02U .0402(d)] 22. The Permittee shall provide notification to the public and its employees about the use of reclaimed water and that reclaimed water is not for drinking. The Permittee shall provide notification to employees in a language they understand. [15A NCAC 02U .0501(a)(2)] 23. The Permittee shall develop and implement an education program to inform users and its employees about the proper use of reclaimed water. The Permittee shall provide educational material to all residents and/or other facilities provided with reclaimed water. The Permittee shall make all educational materials available to the Division upon request. [15A NCAC 02U .0501(a)(4)] IV. MONITORING AND REPORTING 1. The Permittee shall conduct and report any Division -required monitoring, including the monitoring of groundwater, surface water or wetlands, waste, reclaimed water, residuals, soil, treatment processes, lagoon or storage ponds, and plant tissue, if necessary to evaluate this facility's impact on groundwater and surface water. [ 15A NCAC 02T .0108(c), 02U .01081 2. A Division -certified laboratory shall conduct all analyses for the required parameters specified in Attachment A. Parameters measured on -site with in -line metering equipment are exempt from a Division -certified laboratory analysis. [15A NCAC 02H .0805] WQ0015931 Version 5.0 Shell Version 230516 Page 7 of 12 The Permittee shall continuously monitor flow through the treatment facility and report daily flow values on Form NDMR. Facilities with a permitted flow of less than 10,000 GPD may estimate its flow from water usage records provided the water source has a metering device. [15A NCAC 02T .0105 k , 02T .0108(c), 02U .0105, 02U .0108] 4. The Permittee shall monitor the generated reclaimed water at the frequencies and locations for the parameters specified in Attachment A. [15A NCAC 02T .0105(k), 02T .0108(c), 02U .0105, 02U .0108] The Permittee shall maintain records tracking the amount of reclaimed water irrigated, which shall include the following information for each irrigation site listed in Attachment B: a. Date of irrigation. b. Volume of effluent irrigated. c. Site irrigated. d. Length of site irrigation time. e. Continuous weekly, monthly, and year-to-date hydraulic (inches/acre) loadings. £ Continuous monthly and year-to-date loadings for any non -hydraulic parameter specifically limited in Attachment B. g. Weather conditions. h. Maintenance of cover crops. [ 15A NCAC 02T .0108(c), 02U .0108] 6. The Permittee shall measure and record weekly to the nearest inch or tenth of a foot of freeboard (Le., the waste level to the lowest embankment elevation) in the 125,000 gallon five-day upset pond and the 1,739,610 gallon wet weather storage pond. The Permittee shall maintain the weekly freeboard records for eight years and shall make them available to the Division upon request. [ 15A NCAC 02T .0108(c), 02U .0108] 7. On or before the last day of the month following the previous month's sampling, the Permittee shall submit monitoring data (as specified in Conditions IV.3. and IVA.) on Form NDMR for each PPI and operation and disposal records (as specified in Conditions IV.S. and IV.6.) on Form NDAR-1 for every site in Attachment B. If no activities occurred during the monitoring month, the Permittee shall still submit monitoring reports documenting the absence of the activity. The Permittee shall submit the reports via the Non -Discharge monitoring report portal. [15A NCAC 02T .0105(1), 02U .0105] 8. The Permittee shall maintain records of all residuals removed from this facility. The Permittee shall maintain these records for eight years and shall make them available to the Division upon request. These records shall include: a. Name of the residuals hauler. b. Non -Discharge permit number authorizing the residuals disposal, or a letter from a municipality agreeing to accept the residuals. c. Residuals hauling date. d. Volume of residuals removed. 15A NCAC 02U .0802 9. The Permittee shall keep a log of all maintenance done at this facility. The Permittee shall maintain this log for eight years and shall make it available to the Division upon request. This log shall include: a. Date of flow measurement device calibration. b. Date of irrigation equipment calibration. c. Date of turbidimeter calibration. d. Visual observations of the plant and plant site. e. Record of preventative maintenance (e.g., changing of equipment, adjustments, testing, inspections, cleanings, etc.). f. Date and results of the alternate power supply testing. WQ0015931 Version 5.0 Shell Version 230516 Page 8 of 12 g. Record of all discharges of reclaimed water to surface waters or the land surface, including the date of occurrence, estimated volume, and corrective action taken. [ 15A NCAC 02U .0801(h)] 10. Noncompliance Notification: The Permittee shall report to the Mooresville Regional Office, telephone number (704) 663-1699, within 24 hours of first knowledge of the following: a. Treatment of wastes abnormal in quantity or characteristic, including the known passage of a hazardous substance. b. Any process unit failure (e.g., mechanical, electrical, structural, etc.) that makes the facility incapable of adequate reclaimed water generation. c. Any facility failure resulting in a discharge to surface waters. d. Any time self -monitoring indicates the facility has gone out of compliance with its permit limitations. e. Ponding in or runoff from the irrigation sites. f. Any failure resulting in a discharge of reclaimed water directly to surface waters or any release of reclaimed water to land surface greater than or equal to 5,000 gallons. The Permittee shall document releases less than 5,000 gallons to land surface pursuant to Condition IV.9.g. but does not require Regional Office notification. Emergencies requiring reporting outside normal business hours shall call the Division's Emergency Response personnel at the telephone number (800) 858-0368. All noncompliance notifications shall file a written report to the Mooresville Regional Office within five days of first knowledge of the occurrence, and this report shall outline the actions proposed or taken to ensure the problem does not recur. [15A NCAC 02T .0108(b)(1)(A), 02U .0108] V. INSPECTIONS 1. The Permittee shall perform inspections and maintenance to ensure proper operation of the reclaimed water generation and dedicated utilization facilities. [15A NCAC 02U .0801(i)1 2. The Permittee shall inspect the reclaimed water generation and dedicated utilization facilities to prevent malfunctions, facility deterioration, and operator errors that may result in discharges of wastes to the environment, threats to human health, or public nuisances. The Permittee shall maintain an inspection log that includes the date and time of inspection, observations made, and maintenance, repairs, or corrective actions taken. The Permittee shall maintain this inspection log for eight years from the date of the inspection and shall make this log available to the Division upon request. [15A NCAC 02U .0801 h , 02U .0801(i)] Division -authorized representatives may, upon presentation of credentials, enter and inspect any property, premises, or place related to the permitted reclaimed water generation and dedicated utilization facilities at any reasonable time for determining compliance with this permit. Division - authorized representatives may inspect or copy records maintained under the terms and conditions of this permit and may collect influent, treatment process water, generated reclaimed water, residual, soil, plant tissue, groundwater, or surface water samples. [G.S. 143-215.3(a)(2)] WQ0015931 Version 5.0 Shell Version 230516 Page 9 of 12 Vl. GENERAL 1. The Permittee's failure to comply with this permit's conditions and limitations may subject the Permittee to a Division enforcement action. [G.S. 143-215.6A, 143-215.6B, 143-215.6C] 2. This permit is effective only for the nature and volume of wastes described in the permit application and Division -approved plans and specifications. [G.S. 143-215.1(d)1 3. There are no variances to administrative codes or general statutes governing the construction or operation of the permitted facilities unless the Permittee specifically requested a variance in the application and the Division approved the variance as noted in this permit's facility description. [15A NCAC 02T .0105(b), 02U .0105] 4. This permit does not exempt the Permittee from complying with all statutes, rules, regulations, or ordinances that other jurisdictional government agencies (e.g., local, state, and federal) may require. [15A NCAC 02T .0108(b)(1)(A), 02U .01081 5. The Permittee shall retain this permit and the Division -approved plans and specifications for the life of the permitted facilities. [15A NCAC 02T .0105(o), 02T .0116(d), 02U .0105, 02U .0116] 6. The Permittee shall comply with all permit conditions and requirements until the proper closure of the permitted facilities, or until another appropriate authority permits the facilities. [15A NCAC 02T .0105 , 02U .0105] 7. This permit is subject to revocation or modification upon 60-day notice from the Division Director in whole or part for: a. Violation of any terms or conditions of this permit or 15A NCAC 02U. b. Obtaining a permit by misrepresentation or failure to disclose all relevant facts. c. The Permittee's refusal to allow authorized Department employees upon presentation of credentials: I. To enter the Permittee's premises where a system is located or where the Permittee keeps any Division -required records under the terms and conditions of this permit. ii. To have access to any permit -required documents and records. iii. To inspect any monitoring equipment or method as required in this permit. iv. To sample any pollutants. d. The Permittee's failure to pay the annual fee for administering and compliance monitoring. e. A Division determination that the conditions of this permit conflict with the North Carolina Administrative Code or General Statutes. [ 15A NCAC 02T .0110, 02U .0110] WQ0015931 Version 5.0 Shell Version 230516 Page 10 of 12 8. Unless the Division determines that the Permittee needs a permit modification for the construction of facilities to resolve non-compliance with any environmental statute or rule, or the Division Director grants a variance, expansion of the permitted facilities shall not occur if any of the following apply: a. The Permittee or any parent, subsidiary, or other affiliate of the Permittee has been convicted of environmental crimes under G.S. 143-215.6B or under Federal law that would otherwise be prosecuted under G.S. 143-215.6B, and the Permittee or any parent, subsidiary, or other affiliate of the Permittee has abandoned or exhausted all appeals of this conviction. b. The Permittee or any parent, subsidiary, or other affiliate of the Permittee has previously abandoned a wastewater treatment facility without properly closing the facility in accordance with its permit or 15A NCAC 02U. c. The Permittee or any parent, subsidiary, or other affiliate of the Permittee has not paid a civil penalty, and the Permittee or any parent, subsidiary, or other affiliate of the Permittee has abandoned or exhausted all appeals of this penalty. d. The Permittee or any parent, subsidiary, or other affiliate of the Permittee is currently not compliant with any compliance schedule in a permit, settlement agreement, or order. e. The Permittee or any parent, subsidiary, or other affiliate of the Permittee has not paid an annual fee pursuant to 15A NCAC 02T .0105(e)(2) via 15A NCAC 02U .0105. [ 15A NCAC 02T .0120(b), 02T .0120(d), 02U .0120] 9. Unless the Division Director grants a variance, the Division shall not renew this permit if the Permittee or any affiliation has not paid an annual fee pursuant to 15A NCAC 02T .0105(e)(2). [15A NCAC 02T .0120 c , 02T .0120(d), 02U .0105, 02U .0120] 10. The Permittee shall pay an annual fee for each year of the term of this permit pursuant to the schedule in G.S. 143-215.31)(a). The Permittee shall continue to pay annual fees for any facility operating on an expired permit that the Division has not rescinded or revoked. [15A NCAC 02T .0105(e)(2), 02U .0105] Permit issued this the 17t1i day of August 2023 NORTH CAROLINA ENVIRONMENTAL MANAGEMENT COMMISSION DocuSigned by: N t T1,6"Wo D1043082680C483... Richard E. Rogers, Jr., Director Division of Water Resources By Authority of the Environmental Management Commission Permit Number WQ0015931 WQ0015931 Version 5.0 Shell Version 230516 Page 11 of 12 Permit No. WQ0015931 Reclaimed Water Generation and Dedicated Utilization System TNGC Charlotte LLC August 17, 2023 Trump National Golf Club Charlotte WWTP Iredell County ENGINEERING CERTIFICATION ❑ Partial ❑ Final I, , as a duly licensed North Carolina Professional Engineer, having ❑ periodically / ❑ fully observed the construction of the permitted modifications, do hereby state to the best of my abilities that the facility was constructed in compliance with G.S. 143-215.1, Administrative Code Title 15A Subchapter 02U, this permit, and the Division -approved plans and specifications. Documentation of any variation to this permit, and the Division -approved plans and specifications, is in the attached as -built drawings. Description of variations: Professional Engineer's Name Firm Name Firm No. Address City State Zip Code Telephone Email Seal, Signature, and Date��j THE PERMITTEE SHALL SUBMIT THE COMPLETED ENGINEERING CERTIFICATION, INCLUDING ALL SUPPORTING DOCUMENTATION, VIA THE NON -DISCHARGE ONLINE PORTAL. WQ0015931 Version 5.0 Shell Version 230516 Page 12 of 12 ATTACHMENT A — LIMITATIONS AND MONITORING REQUIREMENTS TNGC Charlotte LLC PPI 001— Reclaimed Water Generation System Effluent Certification Date: August 17, 2023 Permit Number: WQ0015931 Version: 5.0 EFFLUENT CHARACTERISTICS EFFLUENT LIMITS MONITORING REQUIREMENTS PCs Code Parameter Description Units of Measure Monthly Average Monthly Geometric Mean Daily Minimum Daily Maximum Measurement Frequency Sample Type 00310 BOD, 5-Day (20 °C) mg/L 10 15 4 x Year' Grab 31616 Coliform, Fecal MF, M-FC Broth, 44.5 °C #/100 mL 14 25 4 x Year' Grab 50050 Flow, in Conduit or thru Treatment Plant GPD 10,000 Continuous Recorder 00610 Nitrogen, Ammonia Total (as N) mg/L 4 6 4 x Year' Grab 00625 Nitrogen, Kjeldahl, Total (as N) mg/L 4 x Year 1 Grab 00620 Nitrogen, Nitrate Total (as N) mg/L 4 x Year' Grab 00600 Nitrogen, Total (as N) mg/L 4 x Year I Grab 00400 pH su 5 x Week Grab 00665 Phosphorus, Total (as P) mg/L 4 x Year 1 Grab 00530 Solids, Total Suspended mg/L 5 10 4 x Year 1 Grab 00076 Turbidity, HCH Turbidimeter NTU 10 Continuous Recorder 1. The Permittee shall conduct 4 x Year sampling in March, June, September, and December. WQ0015931 Version 5.0 Attachment A Page 1 of 1 THIS PAGE BLANK ATTACHMENT B - APPROVED LAND APPLICATION SITES AND LIMITATIONS TNGC Charlotte LLC Certification Date: August 17, 2023 Permit Number: WQ0015931 Version: 5.0 IRRIGATION AREA INFORMATION APPLICATION LEMTATIONS Field Field Owner Parcel No. County Latitude Longitude Net Acreage Dominant Soil Series Parameter Hourly Rate Yearly Max Units D-1 Charlotte LLC 4625-84-8012 Iredell 35.532958' -80.921448' 0.35 Cecil 01284 - Non -Discharge Application Rate 0.12 52.0 inches D-2 TNGC Charlotte LLC 4625-84-8012 Iredell 35.533012' -80.921775' 0.35 Cecil 01284 - Non -Discharge Application Rate 0.12 52.0 inches D-3 TNGC Charlotte LLC 4625-84-8012 Iredell 35.532305' -80.922206' 0.35 Cecil 01284 - Non -Discharge Application Rate 0.12 52.0 inches D-8 TNGC Charlotte LLC 4625-84-8012 Iredell 35.530762' -80.921067' 0.35 Cecil 01284 - Non -Discharge Application Rate 0.12 52.0 inches D-9 TNGC Charlotte LLC 4625-84-8012 Iredell 35.531304' -80.920719' 0.35 Cecil 01284 - Non -Discharge Application Rate 0.12 52.0 inches D-10 TNGC Charlotte LLC 4625-84-8012 Iredell 35.531769' -80.920413' 0.35 Cecil 01284 - Non -Discharge Application Rate 0.12 52.0 inches S-1 TNGC Charlotte LLC 4625-84-8012 Iredell 35.531113' -80.921819' 0.34 Cecil 01284 - Non -Discharge Application Rate 0.33 52.0 inches S-2 TNGC Charlotte LLC 4625-84-8012 Iredell 35.531909' -80.920960' 0.71 Cecil 01284 - Non -Discharge Application Rate 0.33 52.0 inches S-3 TNGC Charlotte LLC 4625-84-8012 Iredell 35.532559' -80.920295' 1.03 Cecil 01284 - Non -Discharge Application Rate 0.33 52.0 inches S-4 TNGC Charlotte LLC 4625-84-8012 Iredell 35.532909' -80.920295' 0.77 Cecil 01284 - Non -Discharge Application Rate 0.33 52.0 inches S-5 TNGC Charlotte LLC 4625-84-8012 Iredell 35.531478' -80.921623' 0.44 Cecil 01284 - Non -Discharge Application Rate 0.33 52.0 inches S-6 TNGC Charlotte LLC 4625-84-8012 Iredell 35.532057' -80.921317' 0.74 Cecil 01284 - Non -Discharge Application Rate 0.33 52.0 inches S-7 TNGC Charlotte LLC 4625-84-8012 Iredell 35.532847' -80.920804' 1.06 Cecil 01284 - Non -Discharge Application Rate 0.33 52.0 inches S-8 TNGC Charlotte LLC 4625-84-8012 Iredell 35.533061' -80.920085' 0.22 Cecil 01284 - Non -Discharge Application Rate 0.33 52.0 inches S-9 TNGC Charlotte LLC 4625-84-8012 Iredell 35.531201' -80.921374' 0.66 Cecil 01284 - Non -Discharge Application Rate 0.33 52.0 inches S-10 TNGC Charlotte LLC 4625-84-8012 Iredell 35.532328' -80.921155' 0.81 Cecil 01284 - Non -Discharge Application Rate 0.33 52.0 inches S-11 TNGC Charlotte LLC 4625-84-8012 Iredell 35.532629' -80.920472' 0.97 Cecil 01284 - Non -Discharge Application Rate 0.33 52.0 inches S-12 TNGC Charlotte LLC 4625-84-8012 Iredell 35.531474' -80.921228' 0.91 Cecil 01284 - Non -Discharge Application Rate 0.33 52.0 inches S-13 TNGC Charlotte LLC 4625-84-8012 Iredell 35.532192' -80.920862' 1.01 Cecil 01284 - Non -Discharge Application Rate 0.33 52.0 inches S-14 TNGC Charlotte LLC 4625-84-8012 Iredell 35.533073' -80.920579' 1.06 Cecil 01284 - Non -Discharge Application Rate 0.33 52.0 inches S-15 TNGC Charlotte LLC 4625-84-8012 Iredell 35.531756' -80.921223' 0.91 Cecil 01284 - Non -Discharge Application Rate 0.33 52.0 inches S-16 TNGC Charlotte LLC 4625-84-8012 Iredell 35.532352' -80.920654' 0.71 Cecil 01284 - Non -Discharge Application Rate 0.33 52.0 inches S-17 TNGC Charlotte LLC 4625-84-8012 Iredell 35.533143' -80.920886' 1.04 Cecil 01284 - Non -Discharge Application Rate 0.33 52.0 inches Total: 15.49 WQ0015931 Version 5.0 Attachment B Page 1 of 1 FIGURE 1 — SITE MAP TNGC Charlotte LLC Permit Number: WQ0015931 Version: 5.0 ISO zs TREE RD. OLE LO ry 9 m ;: T 5f?........_ � VICINITY MAP N.T.S. OUXE POWER GOMPANY 08 338 PG 328 08 318 PG 74 08 338 PG 326 fI� 0 GOMDAW LO75 1. 3_8 M9 7 PG 29 EX. WELL SM ' CRESCENT RE591FRCE5, WC. TAX MAP NO. 2F-A..-7 481--U LAKE NORMAN IHE f i/' FSOR LAKE NORMAN LAKE NORMAN LOSS 27,2B.29 MCI 21 PG 4D LDTS 20.21.22 u8 25 PG 113 SEC 6 -- LOT $69D M$ 18 PG 55 CHANGE ORDER 4: REWSED DRIP F7ELDSIMME MAIN BDS 5 11112198 CHANGE ORDER 3 REVISED SEWER LINE 2 BDS 4 11110198 REVISED BLOOER BLAG BDS 3 2 11109198 10 19/98 ADDED WA7ER METER AND SFP ASSEMBLY CHANGE ORDER 2.• REVISED SAN. SEWER BDS BDS 1 10115198 CHANGE ORDER 1: REVISED SAM, SEWER BDS NO. DATE REVISION BY � 5liEEi isrl.f PRP3fCr 110. 8802pp pp ..••11 9 COMPOSITE SITE PLAN SCA1k: 1 „ 500,I Da 1;± SEPT. 1998 Prlo3ecr UitA1?F j3Y THE VILLAGE BD5 'ls ss1 Fi11 rf777' 011eCKM 9r , a� AT THE POINT ,tAME DCSI CRESCENT RESOURCES 1REDEEE CO. COMPOSITE _ OiiAK1NG Nii SEAL 6988 - -T• l Desian '�� �[`•` ENGINEERING SERVICES INC. 7�ttt+ftiltsssss��s z � 1700 EAST BOULEVARD CHARLOTTE. NC 28203 2-OF �SH"rS jjj PHONE(704) 376- 7777 FAx(704) 376 -8235 corn posi Le.dwg 111,598 J1 J38 y FIGURE 4 -PROPOSED FACILITY SITE MAP (TRUMP NATIONAL GOLF CLUB CHARLOTTE WWTP) SURVEY INFORMATION PROVIDED BY: LDSI, Inc. 201 WEST 29TH STREET CHARLOTTE, NC 28206 704-337-8329 CONTRACTOR TO INSTALL NEW FIBERGLASS BASIN WITH NEW SIMPLEX GRINDER PUMP PACKAGE TO HANDLE WASTE FLOW FROM EX. OFFICE RESTROO M . PROPOSED CONTROL PANEL UNIT FOR PUMPS, UV, TUBIDIMETER & TELEMETRY. ENCLOSURE TO BE NEMA 4X PROPOSED NEW FENCE AROUND TREATMENT AREA AND PONDS. REPLACE WITH LIKE KIND. I NGC Charlotte LLU BB 2168-1361 PB 32-13 Line Legend: Svmbol Description FM ONKPI — I,rI+M UC0111 WAN UNKII R/w FM Fence Line Water Line Esc Force Main Sewer Gravity Sewer Underground Electric Underground Communication Unknown Utility Compressed Air Right -of -Way Prop. Forcemain Sewer PROPOSED TURBIDITY CHAMBER SEE DETAIL ON SHEET U-7 Pry ve 12 �Ft 1Ni.:AII :. p:., ---- - ---- -- --- - Meat ier A ct s `Drive- _ . Textile Filter #2 (Future) r } •.: _ - - - - - - - ,, Stage II Polishing Filter I _ _ 40, Textile Filter # 1 1 _Tca j - - --� - - - - - Generator hi -u� u� Ilr � LC --�• 1E� �JE - - LE � 11E� � LIE ]C jF Lf `r 'JE r fE -&�'F �, -. Ill.l l�•1 lli llfl - II�rOr-1 - Existing Transformer Pad I PROPOSED TEXTILE FILTER NO SEE SHEET U-6 FOR DETAILS f 9 N Existing Office Electrical Panels & Blvwel r Building _ � g` FILTER MAINTENANCE BYPASS w� ��t+r'GotLined Upset Pond EXISTING WWTF TO BE ABANDONED ONCE CONTRACTOR TO INSTALL SEDIMENT FENCING ' - NEW FACILITY IS PERMITTED, INSTALLED AROUND EXISTING UPSET POND AND WET WEATHER +' AND CERTIFIED TO BE PLACED IN OPERATIION. y o I STORAGE POND DURING CONSTRUCTION TO PROTECT I SEE SHEET DEMO-1 FOR DETAILS. ' +I 1 U n � II I I I r I I I I I I UNITS FROM STORMWATER RUNOFF/SEDIMENTATION. F a _�' PROPOSED SEPTIC/FLOW EQUALIZATION I �. TANK. SEE SHEET U-4 FOR DETAILS. I• + � .41 I i� rMto I In IPL ±22 LF OF 4-INCH RESTRAINED JOINT PVC PIPE. I 1 I I N Fk 6 - - 7P _ I ! UL - UE +,�E — UE 4 IIE UE L14 0 ll CUT IN NEW 4-IN. TEE WITH NEW 4- IN■ G.V. S & W OFF NEW TEE T TIE IN PLANT DISCHARGE INTO EX. 6-IN DIP PIPE OUTSIDE LIMITS OF EX. POND LINER. lE HF VICINITY MAP No SCALE WIN PROPOSED (2) UV UNITS IN SERIES & SAMPLE PORT, SEE SHEET U-6 FOR DETAILS PROPOSED POLISHING FILTER SEE SHEET U-6 FOR DETAILS Existing Wet Weather Lined Storage Pond I r1 I [I- I' I-, - � RZ 8�1 Know what's below. Call before you dig. GRAPHIC SCALE 0 5 10 20 1 inch = 10 feet z O ...moo❑ o -.� U� XJ � •v�iwH . A < map pit a 0 V) v a � N 00 �N 02 CW 00 C C6 COJz� o 0 C/2 0 N� a o Q L Ld af v co o �U �.C-) ssl­� 4-4 r� ;_4 P, M c� f'1 o E� .� W a Ei v REVISIONS BY REV. PER COMM24TS BY DEQ - HDPU L PLUMMER DMD (12/20/22) REV. PER COMMENTS BY DEQ - HDPU L PLMMER €]MD (3/31/23) REV. PER COMMENTS BY DEQ - NOPU Z MEGA DMD Date- 6/16/22 Scale: 1=10 Ft 1 n Contours — Drown: DMA] Checked: DEM Project- 2019-03-17-EC .lob: 2019-03-17-EC Sheet U 6/1/23 ZN 7 Sheets