HomeMy WebLinkAboutWQ0015931_Final Permit_20230817ROY COOPER
Governor
ELIZABETH S. BISER
Secretary
RICHARD E. ROGERS, JR.
Director
CHARLES B. LONG — BACK-UP ORC
TNGC CHARLOTTE LLC
120 TRUMP SQUARE
MOORESVILLE, NORTH CAROLINA 28117
Dear Mr. Long,
NORTH CAROLINA
Environmental Quality
August 17, 2023
Subject: Permit No. WQ0015931
Trump National Golf Club
Charlotte WWTP
Reclaimed Water Generation
and Dedicated Utilization
System
Iredell County
In response to your permit major modification and renewal request received on August 10, 2022,
and subsequent additional information received on December 28, 2022, April 3, 2023, and June 22, 2023,
we are forwarding herewith Permit No. WQ0015931 dated August 17, 2023, to TNGC Charlotte LLC for
the continued operation of the existing wastewater collection and dedicated utilization facilities, the
continued operation and subsequent abandonment of the existing reclaimed water generation facilities, and
the construction and operation of the proposed reclaimed water generation facilities.
Modifications to the subject permit are as follows:
➢ The Division has approved the replacement of the existing 25,000 gallon per day (GPD)
reclaimed water generation facility with a 10,000 GPD reclaimed water generation facility
consisting of a flow equalization tank, a primary filter tank, a two -stage polishing filter tank,
and an ultraviolet (UV) disinfection system.
This permit is effective from the date of issuance through June 30, 2030, replace Permit No.
WQ0015931 issued on April 9, 2018, and is subject to the conditions and limitations therein. The
Permittee shall submit a renewal application no later than January 1, 2030.
Please pay attention to the monitoring requirements listed in Attachments A and B for they may
differ from the previous permit issuance. Failure to establish an adequate system for collecting and
maintaining the required operational information may result in future non-compliance.
D � North Carolina Department of Environmental Quality i Division of Water Resources
512 North Salisbury Street 11617 Mail Service Center I Raleigh, North Carolina 27699-1617
NORTH CAROLINA
'.'roMMm 0; /I 919,707,9000
Mr. Charles B. Long
August 17, 2023
Page 2 of 3
The Division has removed the following permit conditions since the last permit issuance dated
April 9, 2018:
➢ Old Condition IL14 —The Division has removed this condition because the Permittee owns all
of the reclaimed water irrigation sites.
➢ Old Condition IIL2.b — The Division has removed this condition.
➢ Old Condition IIL9 — The Division has removed this condition because it is in Condition II1.18.
➢ Old Condition VL2 — The Division has removed this condition because this permit is not
voidable.
The following permit conditions and attachment are new or modified since the last permit
issuance dated April 9, 2018:
➢ Condition I.1 — The Permittee shall submit an Engineering Certification upon completion of
construction and prior to operation of the permitted modifications. The Permittee shall submit
the Engineering Certification via the Non -Discharge online portal.
➢ Condition L2 — The Permittee shall notify the Mooresville Regional Office, telephone number
(704) 663-1699, at least two business days in advance of the initial operation of the constructed
modifications so that the Division can conduct a startup inspection.
➢ Condition L3 — Prior to the operation of the reclaimed water modified facilities, the Permittee
shall submit an amended Operation and Maintenance Plan. The Permittee shall submit the
amended Operation and Maintenance Plan via the Non -Discharge online portal.
➢ Condition IL14 — The Division has modified Old Condition IL8 to decrease the horizontal
distance reclaimed water distribution lines can be located from water lines from 10 feet to 5
feet.
➢ Condition IL15 — The Division has modified Old Condition IL9 to decrease the distance
reclaimed water distribution lines can be located from wells from 100 feet to 50 feet. The
Division has also removed the phrase "or 50 feet from a public well".
➢ Condition IL 16 — The Division has modified Old Condition IL 10 to reference 15A NCAC 02T
.0305 in place of providing sewer line separation distances.
➢ Condition IL 17 — The Division has modified Old Condition IL 15 to correspond to the setbacks
at the time of the original permitting or the most recent major modification for each irrigation
site and storage/treatment unit.
➢ Condition 111.18 — The Permittee shall test and calibrate metering equipment annually.
➢ Condition IIL20 — The Permittee shall provide continuous online monitoring and recording for
turbidity or particle count and flow prior to storage, distribution, or utilization of reclaimed
water.
➢ Condition IV.5.f — The Division has modified Old Condition IV.5 to include continuous
monthly and year-to-date loadings for any non -hydraulic parameter specifically limited in
Attachment B in the reclaimed water irrigation records.
Mr. Charles B. Long
August 17, 2023
Page 3 of 3
➢ Condition IV.9.b — The Division has modified Old Condition IV.8 to include the date of
irrigation equipment calibration in the maintenance log.
➢ Condition IV. IO.c — The Division has modified Old Condition IV.I I to include any facility
failure resulting in a discharge to surface waters in the noncompliance notification.
➢ Condition VL9 — Unless the Division Director grants a variance, the Division shall not renew
this permit if the Permittee or any affiliation has not paid an annual fee pursuant to 15A NCAC
02T .0105(e)(2).
➢ Attachment A — The Division has removed the Total Residual Chlorine effluent parameter
because the Permittee is abandoning the existing backup tablet chlorinator. The Division has
also reduced the sampling frequency for BOD, Fecal Coliform, Ammonia, Total Kjeldahl
Nitrogen, Nitrate, Total Nitrogen, Total Phosphorus, and Total Suspended Solids from Monthly
to 4 x Year.
This permit can be contested as provided in Chapter 150B of the North Carolina General Statutes
by filing a Petition for a Contested Case Hearing (Petition) with the North Carolina Office of Administrative
Hearings (OAH) within 30 calendar days. Requirements for filing a Petition are set forth in Chapter 150B
of the North Carolina General Statutes and Title 26 of the North Carolina Administrative Code. Those
interested in filing may access additional information regarding the requirements for filing a Petition and
Petition forms at the OAH website or by calling the OAH Clerk's Office at (919) 431-3000. A parry filing
a Petition shall serve a copy of the Petition on the Department of Environmental Quality's Office of General
Counsel at 1601 Mail Service Center, Raleigh, NC 27699-1601. If the parry filing the Petition is not the
Permittee, then the party shall also serve the Permittee pursuant to G.S. 15013-23(a).
Included with this permit are Division -approved plans and specifications. If you need additional
information concerning this permit, please contact Zachary Mega at (919) 707-3658 or
zachary.me ag &deq.nc.gov.
Sincerely,
DocuSigned by:
Naf l� oun tt,l Tu"Wo
D1043082680C483...
Richard E. Rogers, Jr., Director
Division of Water Resources
cc: Iredell County Health Department (Electronic Copy)
Mooresville Regional Office, Water Quality Regional Operations Section (Electronic Copy)
Donald L. Munday, PE — Piedmont Design Associates, P.A. (Electronic Copy)
Operator Certification Program (Electronic Copy)
Laserfiche File (Electronic Copy)
Digital Permit Archive (Electronic Copy)
THIS PAGE BLANK
NORTH CAROLINA
ENVIRONMENTAL MANAGEMENT COMMISSION
DEPARTMENT OF ENVIRONMENTAL QUALITY
RALEIGH
RECLAIMED WATER GENERATION AND DEDICATED UTILIZATION SYSTEM PERMIT
Pursuant to the provisions of Article 21 of Chapter 143, General Statutes of North Carolina as amended,
and other applicable Laws, Rules, and Regulations
PERMISSION IS HEREBY GRANTED TO
TNGC Charlotte LLC
Iredell County
FOR THE
operation of a 10,000 gallon per day (GPD) wastewater collection, reclaimed water generation, and
dedicated utilization facility consisting of the:
continued operation of a wastewater collection system consisting of. approximately 2,250 linear feet (LF)
of 8-inch gravity sewer; a 70 gallon per minute (GPM) pump station with duplex pumps and audible/visual
high-water alarms; approximately 1,905 LF of 4-inch force main; and all associated piping, valves, controls,
and appurtenances; the
continued operation and subsequent abandonment of a 25,000 GPD reclaimed water generation facility
consisting of. a screening device; a flow splitter; a 6,250 gallon flow equalization basin with two 35 GPM
pumps; two 12,500 gallon aeration basins served by two 165 cubic feet per minute (CFM) blowers; two
2,167 gallon clarifiers; an ultraviolet (UV) disinfection system with a backup tablet chlorinator; a 6,250
gallon sludge holding tank; an effluent flow meter; two 15 square foot (fl2) tertiary filters; a 4,800 gallon
clearwell with two 225 GPM backwash pumps; a 4,800 gallon backwash return tank with two 26 GPM
pumps; a 15 CFM air scour blower; a continuous in -line turbidimeter; and all associated piping, valves,
controls, and appurtenances; the
construction and operation of a 10,000 GPD reclaimed water generation facility consisting of. a 15,128
gallon flow equalization tank with two 30 GPM pumps; a 15,128 gallon primary filter tank served by three
75 GPM pumps dosing a textile media filter with audible/visual high-water alarms; a two -stage 15,128
gallon polishing filter tank served by one 75 GPM pump mixing a submerged polyethylene media and two
75 GPM pumps dosing a textile media filter with audible/visual high-water alarms; a UV disinfection
system consisting of two 40 GPM units in series; a continuous in -line turbidimeter; an effluent flow meter;
two 30 GPM discharge pumps; and all associated piping, valves, controls, and appurtenances; the
continued operation of. a 125,000 gallon five-day upset pond; a 60 GPM pump station with duplex pumps
and audible/visual high-water alarms; a 1,739,610 gallon wet weather storage pond with two 80 GPM
irrigation pumps; and all associated piping, valves, controls, and appurtenances; and the
continued operation of a dedicated reclaimed water utilization facility consisting of. a 2.10 acre drip
irrigation area with six zones and nineteen 200-foot drip lines; a 150 GPM pump rated at 267 feet of total
dynamic head (TDH); a 13.39 acre spray irrigation area with 17 zones and a total of 49 spray heads; a soil
moisture sensor; and all associated piping, valves, controls, and appurtenances
WQ0015931 Version 5.0 Shell Version 230516 Page 1 of 12
to serve the Trump National Golf Club Charlotte WWTP, with no discharge of wastes to surface waters,
pursuant to the application received on August 10, 2022, subsequent additional information received on
December 28, 2022, April 3, 2023, and June 22, 2023, and in conformity with the Division -approved plans
and specifications considered a part of this permit.
This permit is effective from the date of issuance through June 30, 2030, shall replace Permit No.
WQ0015931 issued on April 9, 2018, and is subject to the following conditions and limitations:
I. SCHEDULES
Upon completion of construction and prior to operation of the permitted modifications, the Permittee
shall submit an engineering certification from a North Carolina licensed Professional Engineer
certifying that the permitted facility has been constructed pursuant to G.S. 143-215.1, Administrative
Code Title 15A Subchapter 02U, this permit, and the Division -approved plans and specifications. For
phased and partially certified facilities, the Permittee shall retain the responsibility to track further
construction approved under this permit and shall provide a final engineering certification upon project
completion. The Permittee shall submit the Engineering Certification via the Non -Discharge online
portal. [15A NCAC 02T .0116(a), 02U .01161
2. The Permittee shall notify the Mooresville Regional Office, telephone number (704) 663-1699, at least
two business days in advance of the initial operation of the constructed modifications so that the
Division can conduct a startup inspection. [ 15A NCAC 02T .0108(b)(1)(A), 02U .0108]
3. Prior to the operation of the reclaimed water modified facilities, the Permittee shall submit an amended
Operation and Maintenance Plan. The Permittee shall submit the amended Operation and Maintenance
Plan via the Non -Discharge online portal_ [15A NCAC 02T .0108(b)(1)(B), 02U .0108, 02U .0801(a)]
4. If the permitted facilities change ownership or the Permittee changes its name, the Permittee shall
submit a permit modification request on Division -approved forms within 90 days of the change of
ownership. The Permittee shall comply with all terms and conditions of this permit until the Division
transfers the permit to the successor -owner. [G.S. 143-215.1(d3)]
5. The Permittee shall request renewal of this permit on Division -approved forms no later than January 1,
2030. [15A NCAC 02T .0105(b), 02T .0109, 02U .0105, 02U .0109]
IL PERFORMANCE STANDARDS
The Permittee shall operate and maintain the subject reclaimed water generation and dedicated
utilization facilities so there is no discharge to surface waters, nor any contravention of groundwater or
surface water standards. In the event the facilities do not perform as designed, including the creation
of nuisance conditions due to improper operation and maintenance, or failure of the utilization areas to
assimilate the reclaimed water, the Permittee shall take immediate corrective actions, including
Division -required actions, such as the construction of additional or replacement reclaimed water
generation and dedicated utilization facilities. [15A NCAC 02T .0108(b)(1)(A), 02U .0108]
2. This permit shall not relieve the Permittee of its responsibility for contravention of groundwater or
surface water standards resulting from the operation of this facility. [15A NCAC 02T .0108(b)(1)(A),
02U .0108]
WQ0015931 Version 5.0 Shell Version 230516 Page 2 of 12
3. The Permittee shall operate and maintain the permitted wastewater collection facilities pursuant to the
following criteria:
a. The Permittee shall operate and maintain the collection system to prevent discharge to land or
surface waters and to prevent contravention of groundwater or surface water standards.
b. The Permittee shall develop and maintain a map of the collection system.
c. The Permittee shall develop, implement, and maintain an operation and maintenance plan.
d. The Permittee shall inspect pump stations not connected to a telemetry system every day unless the
Division approves otherwise. The Permittee shall inspect pump stations connected to a telemetry
system once per week.
e. The Permittee shall inspect high -priority sewers once every six months.
f. The Permittee shall conduct a general observation of the entire collection system once per year.
g. The Permittee shall report overflows and bypasses to the Mooresville Regional Office pursuant to
15A NCAC 02B .0506(a) and the Permittee shall provide public notice as required by G.S. 143-
215.1C.
h. The Permittee shall develop, implement, and maintain a grease control program.
i. The Permittee shall maintain rights -of -way and easements.
j. The Permittee shall maintain documentation of compliance with the above requirements for three
years, except for the map, which the Permittee shall maintain for the life of the system.
[ 15A NCAC 02T .0403(a)]
4. Reclaimed water quality shall not exceed the limitations specified in Attachment A. [15A NCAC 02U
.0301]
5. The Permittee shall not utilize generated reclaimed water in exceedance of the hydraulic and agronomic
rates specified in Attachment B. [15A NCAC 02U .0401(a)]
6. The Permittee shall tag or label all reclaimed water valves, storage facilities, and outlets to warn the
public or employees that the reclaimed water is not for drinking. [ 15A NCAC 02U .0403(b)]
7. The Permittee shall color -code, tape, or otherwise mark all reclaimed water piping, valves, outlets, and
other appurtenances to identify the source of the water as reclaimed water as follows:
a. All reclaimed water piping and appurtenances shall be either colored purple (Pantone 522 or
equivalent) and embossed or integrally stamped or marked "CAUTION: RECLAIMED WATER -
DO NOT DRINK" or installed with a purple (Pantone 522 or equivalent) identification tape or
polyethylene vinyl wrap. The warning shall be on opposite sides of the pipe and repeated every
three feet or less.
b. Identification tape shall be at least three inches wide and have white or black lettering on a purple
(Pantone 522 or equivalent) field stating "CAUTION: RECLAIMED WATER - DO NOT
DRINK." The Permittee shall install identification tape on top of reclaimed water pipelines
fastened at least every 10 feet to each pipe length and run continuously the entire length of the pipe.
c. The Permittee shall tape or otherwise identify existing underground distribution systems retrofitted
for conveying reclaimed water as described in Paragraphs a. and b. above. The Permittee shall
perform this identification within 10 feet of any potable water supply line or sanitary sewer line
crossing a reclaimed water line. The Permittee does not need to perform this identification for the
entire length of the distribution system.
[ 15A NCAC 02U .0403(c)1
8. The Permittee shall secure all reclaimed water valves and outlets such that only Permittee-authorized
personnel can operate them. [15A NCAC 02U .0403(d)]
WQ0015931 Version 5.0 Shell Version 230516 Page 3 of 12
9. The Permittee shall place hose bibs in locked, below -grade vaults and label them non -potable. The
Permittee may place hose bibs above ground and label them non -potable if the hose bibs require a tool
to operate. [15A NCAC 02U .0403(e)]
10. There shall be no direct cross -connections between the reclaimed water and potable water systems
unless such connection is Department -approved pursuant to 15A NCAC 18C .0406. [15A NCAC 02U
.0403
11. For reclaimed water irrigation fields permitted prior to September 1, 2006, the Division has established
the compliance and review boundaries at the property boundary. Any exceedance of groundwater
standards at or beyond the compliance boundary shall require the Permittee to take corrective action.
The Division shall note any Division -approved relocation of the compliance boundary in Attachment
B. The Division shall consider multiple contiguous properties under common ownership and permitted
for use as a disposal system as a single property regarding the determination of a compliance boundary.
[15A NCAC 02H .0219(k)(1)(C)(i)(III), 02L .0106(e), 02L .0107(c), 02L .0107(fl, 02T .0105(h)1
12. The Permittee shall notify the Division of any sale or transfer of property affecting a compliance
boundary (i.e., parcel subdivision). [15A NCAC 02L .0107(1)]
13. The Permittee or any landowner who owns land within the compliance boundary shall not construct
any water supply wells within the compliance boundary. [ 15A NCAC 02L .0107(i)]
14. Reclaimed water distribution lines shall be at least five feet horizontally from and 18 inches below any
water line if practicable. If these separation distances cannot be met, the piping and integrity testing
procedures shall meet water main standards pursuant to 15A NCAC 18C. [ 15A NCAC 02U .0403(a),
02U .0403(h)]
15. Reclaimed water distribution lines shall not be less than 50 feet from a well unless the piping and
integrity testing procedures meet water main standards pursuant to 15A NCAC 18C, but in no case
shall they be less than 25 feet from a private well. [15A NCAC 02U .0403(a), 02U .0403(i)]
16. Reclaimed water distribution lines shall meet the separation distances to sewer lines pursuant to 15A
NCAC 02T .0305. [15A NCAC 02U .0403(g), 02U .0403(j)]
17. The Permittee shall operate and maintain the permitted facilities pursuant to the following setbacks:
a. The Division originally permitted the reclaimed water irrigation sites on February 9,1999, and May
17, 2005, with applications received on September 28, 1998, and April 21, 2005, respectively. The
setbacks for spray and drip reclaimed water irrigation sites originally permitted or modified with
an application received from June 1, 1996, through August 31, 2006, are as follows (all distances
in feet):
i. Surface waters classified SA: 100
ii. Surface waters not classified SA: 25
In. Each water supply well: 100
iv. Each non -potable well: 10
v. Each swimming pool: 25
[15A NCAC 02H .0219(k)(1)(C)(i)]
WQ0015931 Version 5.0 Shell Version 230516 Page 4 of 12
b. The Division originally permitted the 125,000 gallon five-day upset pond and the 1,739,610 gallon
wet weather storage pond on February 9, 1999, with an application received on September 28,
1998. The setbacks for treatment and storage units originally permitted or modified with an
application received from June 1, 1996, through August 31, 2006, are as follows (all distances in
feet):
I.
Each habitable residence or place of assembly under separate ownership:
100,
ii.
Each private or public water supply source:
100
iii.
Surface waters:
50
iv.
Each well with exception of monitoring wells:
100
v.
Each property line:
50
vi.
Nitrification field:
20
' Habitable residences or places of assembly under separate ownership constructed after the
Division originally permitted or subsequently modified the facilities are exempt from this
setback.
2 Setbacks to property lines are not applicable when the Permittee, or the entity from which the
Permittee is leasing, owns both parcels separated by the property line.
[ 15A NCAC 02H .0219(i)(5)]
c. The Division permitted modifications to the treatment units on August 17, 2023, with an application
received on August 10, 2022. The setbacks for treatment and storage units originally permitted or
modified with an application received on or after September 1, 2018, are as follows (all distances
in feet):
I. Each habitable residence or place of assembly under separate ownership:
1001
ii. Each private or public water supply source:
100
iii. Surface waters:
50
iv. Each well with exception of monitoring wells:
100
v. Each property line:
50 2
' Habitable residences or places of assembly under separate ownership constructed after the
Division originally permitted or subsequently modified the facilities are exempt from this
setback.
2 Setbacks to property lines are not applicable when the Permittee, or the entity from which the
Permittee is leasing, owns both parcels separated by the property line.
[15A NCAC 02T .0506(b), 02U .0701(a), 02U .0701(h), 02U .0701(i)]
WQ0015931 Version 5.0 Shell Version 230516 Page 5 of 12
III. OPERATION AND MAINTENANCE
1. The Permittee shall operate and maintain the subject facilities as anon -discharge system. [15A NCAC
02U .0101]
2. The Permittee shall maintain an Operation and Maintenance Plan, which shall include:
a. A description of the operation of the system in sufficient detail to show what operations are
necessary for the system to function and who shall conduct the operations.
b. A description of the anticipated maintenance of the system.
c. Provisions for safety measures, including restriction of access to the site and equipment.
d. Spill control provisions that include response to upsets and bypasses, including control,
containment, and remediation; and contact information for personnel, emergency responders, and
regulatory agencies.
f 15A NCAC 02U .0801(a)]
3. Upon the Water Pollution Control System Operators Certification Commission's (WPCSOCC)
classification of the subject non -discharge facilities, the Permittee shall designate and employ a certified
Operator in Responsible Charge (ORC), and one or more certified operators as Back-up ORCs. The
ORC or its Back-up shall operate and visit the facilities as required pursuant to 15A NCAC 08G .0204
and 08G .0205. [ 15A NCAC 02T .0117, 02U .0117]
4. An operator certified by the Water Pollution Control System Operators Certification Commission
(WPCSOCC) of a grade equivalent or greater than the facility classification shall be on call 24 hours
per day. [ 15A NCAC 02U .0401(e)]
5. The Permittee shall maintain a year-round vegetative cover on the irrigation area such that crop health
is optimal and allows even reclaimed water distribution and inspection of the irrigation system. [15A
NCAC 02U .0801(b)]
6. The Permittee shall take measures to prevent reclaimed water ponding in or runoff from the irrigation
area. [ 15A NCAC 02U .0801(c)1
7. The Permittee shall not irrigate generated reclaimed water during inclement weather or when the soil
is in a condition that will cause ponding or runoff. [ 15A NCAC 02U .0401(k)]
8. The Permittee shall test and calibrate the irrigation equipment once per permit cycle. [ 15A NCAC 02U
.0801 d
9. The Permittee shall only irrigate reclaimed water generated from the Trump National Golf Club
Charlotte WWTP onto the sites listed in Attachment B. [ 15A NCAC 02U .0101]
10. The Permittee shall not allow vehicles or heavy machinery on the irrigation area, except during
equipment installation or maintenance activities. [ 15A NCAC 02U .0801(e)1
11. The Permittee shall prohibit public access to the reclaimed water generation and storage facilities. [15A
NCAC 02T .0108(b)(1)(A), 02U .0108]
12. The Permittee shall control public access to reclaimed water utilization sites during active site use.
[15A NCAC 02U .0501(a)(2)]
13. The Permittee shall dispose of or utilize generated residuals in a Division -approved manner. [15A
NCAC 02T .1101, 02U .08021.
14. The Permittee shall not divert or bypass untreated or partially treated reclaimed water from the subject
facilities. [15A NCAC 02U .0402(g)]
WQ0015931 Version 5.0 Shell Version 230516 Page 6 of 12
15. The Permittee shall maintain a freeboard of not less than two feet in the 125,000 gallon five-day upset
pond and the 1,739,610 gallon wet weather storage pond. [15A NCAC 02U .0401(h)]
16. The Permittee shall provide gauges to monitor freeboard levels in the 125,000 gallon five-day upset
pond and the 1,739,610 gallon wet weather storage pond. These gauges shall have readily visible
permanent markings, at inch or tenth of foot increments, indicating the following elevations: the
maximum liquid level at the top of the temporary liquid storage volume, the minimum liquid level at
the bottom of the temporary liquid storage volume, and the lowest point on top of the dam. [ 15A NCAC
02U .0801(fl]
17. The Permittee shall establish and maintain a protective vegetative cover on all berms, pipe runs, erosion
control areas, surface water diversions, and earthen embankments (i.e., the outside toe of the
embankment to the maximum allowable temporary storage elevation on the inside of the embankment).
The Permittee shall remove all trees, shrubs, and other woody vegetation from earthen dikes and
embankments. The Permittee shall keep all earthen embankments mowed or otherwise controlled and
accessible. [15A NCAC 02U .0801(a)]
18. The Permittee shall test and calibrate metering equipment annually. [15A NCAC 02U .0801(d)]
19. The Permittee shall provide an automatically activated standby power source or other means to prevent
improperly treated wastewater from entering the storage, distribution, or utilization system. If the
Permittee employs a generator as an alternate power supply, the Permittee shall test it weekly. [15A
NCAC 02U .0401(d)]
20. The Permittee shall provide continuous online monitoring and recording for turbidity or particle count
and flow prior to storage, distribution, or utilization of reclaimed water. [ 15A NCAC 02U .0401(b)]
21. If the generated reclaimed water exceeds 10 nephelometric turbidity units (NTUs) or the pathogen
limits in Attachment A, the Permittee shall route all generated reclaimed water to the 125,000 gallon
five-day upset pond until the Permittee corrects all problems associated with the reclaimed water
generation system. The Permittee shall pump all water in the 125,000 gallon five-day upset pond back
to the treatment plant headworks for re -treatment or treat the water in the 125,000 gallon five-day upset
pond prior to utilization. [ 15A NCAC 02U .0402(d)]
22. The Permittee shall provide notification to the public and its employees about the use of reclaimed
water and that reclaimed water is not for drinking. The Permittee shall provide notification to
employees in a language they understand. [15A NCAC 02U .0501(a)(2)]
23. The Permittee shall develop and implement an education program to inform users and its employees
about the proper use of reclaimed water. The Permittee shall provide educational material to all
residents and/or other facilities provided with reclaimed water. The Permittee shall make all
educational materials available to the Division upon request. [15A NCAC 02U .0501(a)(4)]
IV. MONITORING AND REPORTING
1. The Permittee shall conduct and report any Division -required monitoring, including the monitoring of
groundwater, surface water or wetlands, waste, reclaimed water, residuals, soil, treatment processes,
lagoon or storage ponds, and plant tissue, if necessary to evaluate this facility's impact on groundwater
and surface water. [ 15A NCAC 02T .0108(c), 02U .01081
2. A Division -certified laboratory shall conduct all analyses for the required parameters specified in
Attachment A. Parameters measured on -site with in -line metering equipment are exempt from a
Division -certified laboratory analysis. [15A NCAC 02H .0805]
WQ0015931 Version 5.0 Shell Version 230516 Page 7 of 12
The Permittee shall continuously monitor flow through the treatment facility and report daily flow
values on Form NDMR. Facilities with a permitted flow of less than 10,000 GPD may estimate its
flow from water usage records provided the water source has a metering device. [15A NCAC 02T
.0105 k , 02T .0108(c), 02U .0105, 02U .0108]
4. The Permittee shall monitor the generated reclaimed water at the frequencies and locations for the
parameters specified in Attachment A. [15A NCAC 02T .0105(k), 02T .0108(c), 02U .0105, 02U
.0108]
The Permittee shall maintain records tracking the amount of reclaimed water irrigated, which shall
include the following information for each irrigation site listed in Attachment B:
a. Date of irrigation.
b. Volume of effluent irrigated.
c. Site irrigated.
d. Length of site irrigation time.
e. Continuous weekly, monthly, and year-to-date hydraulic (inches/acre) loadings.
£ Continuous monthly and year-to-date loadings for any non -hydraulic parameter specifically
limited in Attachment B.
g. Weather conditions.
h. Maintenance of cover crops.
[ 15A NCAC 02T .0108(c), 02U .0108]
6. The Permittee shall measure and record weekly to the nearest inch or tenth of a foot of freeboard (Le.,
the waste level to the lowest embankment elevation) in the 125,000 gallon five-day upset pond and the
1,739,610 gallon wet weather storage pond. The Permittee shall maintain the weekly freeboard records
for eight years and shall make them available to the Division upon request. [ 15A NCAC 02T .0108(c),
02U .0108]
7. On or before the last day of the month following the previous month's sampling, the Permittee shall
submit monitoring data (as specified in Conditions IV.3. and IVA.) on Form NDMR for each PPI and
operation and disposal records (as specified in Conditions IV.S. and IV.6.) on Form NDAR-1 for every
site in Attachment B. If no activities occurred during the monitoring month, the Permittee shall still
submit monitoring reports documenting the absence of the activity. The Permittee shall submit the
reports via the Non -Discharge monitoring report portal. [15A NCAC 02T .0105(1), 02U .0105]
8. The Permittee shall maintain records of all residuals removed from this facility. The Permittee shall
maintain these records for eight years and shall make them available to the Division upon request.
These records shall include:
a. Name of the residuals hauler.
b. Non -Discharge permit number authorizing the residuals disposal, or a letter from a municipality
agreeing to accept the residuals.
c. Residuals hauling date.
d. Volume of residuals removed.
15A NCAC 02U .0802
9. The Permittee shall keep a log of all maintenance done at this facility. The Permittee shall maintain
this log for eight years and shall make it available to the Division upon request. This log shall include:
a. Date of flow measurement device calibration.
b. Date of irrigation equipment calibration.
c. Date of turbidimeter calibration.
d. Visual observations of the plant and plant site.
e. Record of preventative maintenance (e.g., changing of equipment, adjustments, testing,
inspections, cleanings, etc.).
f. Date and results of the alternate power supply testing.
WQ0015931 Version 5.0 Shell Version 230516 Page 8 of 12
g. Record of all discharges of reclaimed water to surface waters or the land surface, including the date
of occurrence, estimated volume, and corrective action taken.
[ 15A NCAC 02U .0801(h)]
10. Noncompliance Notification:
The Permittee shall report to the Mooresville Regional Office, telephone number (704) 663-1699,
within 24 hours of first knowledge of the following:
a. Treatment of wastes abnormal in quantity or characteristic, including the known passage of a
hazardous substance.
b. Any process unit failure (e.g., mechanical, electrical, structural, etc.) that makes the facility
incapable of adequate reclaimed water generation.
c. Any facility failure resulting in a discharge to surface waters.
d. Any time self -monitoring indicates the facility has gone out of compliance with its permit
limitations.
e. Ponding in or runoff from the irrigation sites.
f. Any failure resulting in a discharge of reclaimed water directly to surface waters or any release of
reclaimed water to land surface greater than or equal to 5,000 gallons. The Permittee shall
document releases less than 5,000 gallons to land surface pursuant to Condition IV.9.g. but does
not require Regional Office notification.
Emergencies requiring reporting outside normal business hours shall call the Division's Emergency
Response personnel at the telephone number (800) 858-0368. All noncompliance notifications shall
file a written report to the Mooresville Regional Office within five days of first knowledge of the
occurrence, and this report shall outline the actions proposed or taken to ensure the problem does not
recur. [15A NCAC 02T .0108(b)(1)(A), 02U .0108]
V. INSPECTIONS
1. The Permittee shall perform inspections and maintenance to ensure proper operation of the reclaimed
water generation and dedicated utilization facilities. [15A NCAC 02U .0801(i)1
2. The Permittee shall inspect the reclaimed water generation and dedicated utilization facilities to prevent
malfunctions, facility deterioration, and operator errors that may result in discharges of wastes to the
environment, threats to human health, or public nuisances. The Permittee shall maintain an inspection
log that includes the date and time of inspection, observations made, and maintenance, repairs, or
corrective actions taken. The Permittee shall maintain this inspection log for eight years from the date
of the inspection and shall make this log available to the Division upon request. [15A NCAC 02U
.0801 h , 02U .0801(i)]
Division -authorized representatives may, upon presentation of credentials, enter and inspect any
property, premises, or place related to the permitted reclaimed water generation and dedicated
utilization facilities at any reasonable time for determining compliance with this permit. Division -
authorized representatives may inspect or copy records maintained under the terms and conditions of
this permit and may collect influent, treatment process water, generated reclaimed water, residual, soil,
plant tissue, groundwater, or surface water samples. [G.S. 143-215.3(a)(2)]
WQ0015931 Version 5.0 Shell Version 230516 Page 9 of 12
Vl. GENERAL
1. The Permittee's failure to comply with this permit's conditions and limitations may subject the
Permittee to a Division enforcement action. [G.S. 143-215.6A, 143-215.6B, 143-215.6C]
2. This permit is effective only for the nature and volume of wastes described in the permit application
and Division -approved plans and specifications. [G.S. 143-215.1(d)1
3. There are no variances to administrative codes or general statutes governing the construction or
operation of the permitted facilities unless the Permittee specifically requested a variance in the
application and the Division approved the variance as noted in this permit's facility description. [15A
NCAC 02T .0105(b), 02U .0105]
4. This permit does not exempt the Permittee from complying with all statutes, rules, regulations, or
ordinances that other jurisdictional government agencies (e.g., local, state, and federal) may require.
[15A NCAC 02T .0108(b)(1)(A), 02U .01081
5. The Permittee shall retain this permit and the Division -approved plans and specifications for the life of
the permitted facilities. [15A NCAC 02T .0105(o), 02T .0116(d), 02U .0105, 02U .0116]
6. The Permittee shall comply with all permit conditions and requirements until the proper closure of the
permitted facilities, or until another appropriate authority permits the facilities. [15A NCAC 02T
.0105 , 02U .0105]
7. This permit is subject to revocation or modification upon 60-day notice from the Division Director in
whole or part for:
a. Violation of any terms or conditions of this permit or 15A NCAC 02U.
b. Obtaining a permit by misrepresentation or failure to disclose all relevant facts.
c. The Permittee's refusal to allow authorized Department employees upon presentation of
credentials:
I. To enter the Permittee's premises where a system is located or where the Permittee keeps any
Division -required records under the terms and conditions of this permit.
ii. To have access to any permit -required documents and records.
iii. To inspect any monitoring equipment or method as required in this permit.
iv. To sample any pollutants.
d. The Permittee's failure to pay the annual fee for administering and compliance monitoring.
e. A Division determination that the conditions of this permit conflict with the North Carolina
Administrative Code or General Statutes.
[ 15A NCAC 02T .0110, 02U .0110]
WQ0015931 Version 5.0 Shell Version 230516 Page 10 of 12
8. Unless the Division determines that the Permittee needs a permit modification for the construction of
facilities to resolve non-compliance with any environmental statute or rule, or the Division Director
grants a variance, expansion of the permitted facilities shall not occur if any of the following apply:
a. The Permittee or any parent, subsidiary, or other affiliate of the Permittee has been convicted of
environmental crimes under G.S. 143-215.6B or under Federal law that would otherwise be
prosecuted under G.S. 143-215.6B, and the Permittee or any parent, subsidiary, or other affiliate of
the Permittee has abandoned or exhausted all appeals of this conviction.
b. The Permittee or any parent, subsidiary, or other affiliate of the Permittee has previously abandoned
a wastewater treatment facility without properly closing the facility in accordance with its permit
or 15A NCAC 02U.
c. The Permittee or any parent, subsidiary, or other affiliate of the Permittee has not paid a civil
penalty, and the Permittee or any parent, subsidiary, or other affiliate of the Permittee has
abandoned or exhausted all appeals of this penalty.
d. The Permittee or any parent, subsidiary, or other affiliate of the Permittee is currently not compliant
with any compliance schedule in a permit, settlement agreement, or order.
e. The Permittee or any parent, subsidiary, or other affiliate of the Permittee has not paid an annual
fee pursuant to 15A NCAC 02T .0105(e)(2) via 15A NCAC 02U .0105.
[ 15A NCAC 02T .0120(b), 02T .0120(d), 02U .0120]
9. Unless the Division Director grants a variance, the Division shall not renew this permit if the Permittee
or any affiliation has not paid an annual fee pursuant to 15A NCAC 02T .0105(e)(2). [15A NCAC 02T
.0120 c , 02T .0120(d), 02U .0105, 02U .0120]
10. The Permittee shall pay an annual fee for each year of the term of this permit pursuant to the schedule
in G.S. 143-215.31)(a). The Permittee shall continue to pay annual fees for any facility operating on
an expired permit that the Division has not rescinded or revoked. [15A NCAC 02T .0105(e)(2), 02U
.0105]
Permit issued this the 17t1i day of August 2023
NORTH CAROLINA ENVIRONMENTAL MANAGEMENT COMMISSION
DocuSigned by:
N t T1,6"Wo
D1043082680C483...
Richard E. Rogers, Jr., Director
Division of Water Resources
By Authority of the Environmental Management Commission
Permit Number WQ0015931
WQ0015931 Version 5.0 Shell Version 230516 Page 11 of 12
Permit No. WQ0015931 Reclaimed Water Generation and Dedicated Utilization
System
TNGC Charlotte LLC August 17, 2023
Trump National Golf Club Charlotte WWTP Iredell County
ENGINEERING CERTIFICATION
❑ Partial ❑ Final
I, , as a duly licensed North Carolina Professional
Engineer, having ❑ periodically / ❑ fully observed the construction of the permitted modifications, do
hereby state to the best of my abilities that the facility was constructed in compliance with G.S. 143-215.1,
Administrative Code Title 15A Subchapter 02U, this permit, and the Division -approved plans and
specifications.
Documentation of any variation to this permit, and the Division -approved plans and specifications, is in the
attached as -built drawings.
Description of variations:
Professional Engineer's Name
Firm Name
Firm No.
Address
City
State
Zip Code
Telephone
Email
Seal, Signature, and Date��j
THE PERMITTEE SHALL SUBMIT THE COMPLETED ENGINEERING CERTIFICATION, INCLUDING
ALL SUPPORTING DOCUMENTATION, VIA THE NON -DISCHARGE ONLINE PORTAL.
WQ0015931 Version 5.0 Shell Version 230516 Page 12 of 12
ATTACHMENT A — LIMITATIONS AND MONITORING REQUIREMENTS
TNGC Charlotte LLC
PPI 001— Reclaimed Water Generation System Effluent
Certification Date: August 17, 2023
Permit Number: WQ0015931 Version: 5.0
EFFLUENT CHARACTERISTICS
EFFLUENT LIMITS
MONITORING REQUIREMENTS
PCs
Code
Parameter Description
Units of
Measure
Monthly
Average
Monthly
Geometric Mean
Daily Minimum
Daily Maximum
Measurement
Frequency
Sample
Type
00310
BOD, 5-Day (20 °C)
mg/L
10
15
4 x Year'
Grab
31616
Coliform, Fecal MF, M-FC Broth, 44.5 °C
#/100 mL
14
25
4 x Year'
Grab
50050
Flow, in Conduit or thru Treatment Plant
GPD
10,000
Continuous
Recorder
00610
Nitrogen, Ammonia Total (as N)
mg/L
4
6
4 x Year'
Grab
00625
Nitrogen, Kjeldahl, Total (as N)
mg/L
4 x Year 1
Grab
00620
Nitrogen, Nitrate Total (as N)
mg/L
4 x Year'
Grab
00600
Nitrogen, Total (as N)
mg/L
4 x Year I
Grab
00400
pH
su
5 x Week
Grab
00665
Phosphorus, Total (as P)
mg/L
4 x Year 1
Grab
00530
Solids, Total Suspended
mg/L
5
10
4 x Year 1
Grab
00076
Turbidity, HCH Turbidimeter
NTU
10
Continuous
Recorder
1. The Permittee shall conduct 4 x Year sampling in March, June, September, and December.
WQ0015931 Version 5.0 Attachment A Page 1 of 1
THIS PAGE BLANK
ATTACHMENT B - APPROVED LAND APPLICATION SITES AND LIMITATIONS
TNGC Charlotte LLC
Certification Date: August 17, 2023
Permit Number: WQ0015931 Version: 5.0
IRRIGATION AREA INFORMATION
APPLICATION LEMTATIONS
Field
Field
Owner
Parcel No.
County
Latitude
Longitude
Net
Acreage
Dominant
Soil Series
Parameter
Hourly
Rate
Yearly
Max
Units
D-1
Charlotte LLC
4625-84-8012
Iredell
35.532958'
-80.921448'
0.35
Cecil
01284 - Non -Discharge Application Rate
0.12
52.0
inches
D-2
TNGC Charlotte LLC
4625-84-8012
Iredell
35.533012'
-80.921775'
0.35
Cecil
01284 - Non -Discharge Application Rate
0.12
52.0
inches
D-3
TNGC Charlotte LLC
4625-84-8012
Iredell
35.532305'
-80.922206'
0.35
Cecil
01284 - Non -Discharge Application Rate
0.12
52.0
inches
D-8
TNGC Charlotte LLC
4625-84-8012
Iredell
35.530762'
-80.921067'
0.35
Cecil
01284 - Non -Discharge Application Rate
0.12
52.0
inches
D-9
TNGC Charlotte LLC
4625-84-8012
Iredell
35.531304'
-80.920719'
0.35
Cecil
01284 - Non -Discharge Application Rate
0.12
52.0
inches
D-10
TNGC Charlotte LLC
4625-84-8012
Iredell
35.531769'
-80.920413'
0.35
Cecil
01284 - Non -Discharge Application Rate
0.12
52.0
inches
S-1
TNGC Charlotte LLC
4625-84-8012
Iredell
35.531113'
-80.921819'
0.34
Cecil
01284 - Non -Discharge Application Rate
0.33
52.0
inches
S-2
TNGC Charlotte LLC
4625-84-8012
Iredell
35.531909'
-80.920960'
0.71
Cecil
01284 - Non -Discharge Application Rate
0.33
52.0
inches
S-3
TNGC Charlotte LLC
4625-84-8012
Iredell
35.532559'
-80.920295'
1.03
Cecil
01284 - Non -Discharge Application Rate
0.33
52.0
inches
S-4
TNGC Charlotte LLC
4625-84-8012
Iredell
35.532909'
-80.920295'
0.77
Cecil
01284 - Non -Discharge Application Rate
0.33
52.0
inches
S-5
TNGC Charlotte LLC
4625-84-8012
Iredell
35.531478'
-80.921623'
0.44
Cecil
01284 - Non -Discharge Application Rate
0.33
52.0
inches
S-6
TNGC Charlotte LLC
4625-84-8012
Iredell
35.532057'
-80.921317'
0.74
Cecil
01284 - Non -Discharge Application Rate
0.33
52.0
inches
S-7
TNGC Charlotte LLC
4625-84-8012
Iredell
35.532847'
-80.920804'
1.06
Cecil
01284 - Non -Discharge Application Rate
0.33
52.0
inches
S-8
TNGC Charlotte LLC
4625-84-8012
Iredell
35.533061'
-80.920085'
0.22
Cecil
01284 - Non -Discharge Application Rate
0.33
52.0
inches
S-9
TNGC Charlotte LLC
4625-84-8012
Iredell
35.531201'
-80.921374'
0.66
Cecil
01284 - Non -Discharge Application Rate
0.33
52.0
inches
S-10
TNGC Charlotte LLC
4625-84-8012
Iredell
35.532328'
-80.921155'
0.81
Cecil
01284 - Non -Discharge Application Rate
0.33
52.0
inches
S-11
TNGC Charlotte LLC
4625-84-8012
Iredell
35.532629'
-80.920472'
0.97
Cecil
01284 - Non -Discharge Application Rate
0.33
52.0
inches
S-12
TNGC Charlotte LLC
4625-84-8012
Iredell
35.531474'
-80.921228'
0.91
Cecil
01284 - Non -Discharge Application Rate
0.33
52.0
inches
S-13
TNGC Charlotte LLC
4625-84-8012
Iredell
35.532192'
-80.920862'
1.01
Cecil
01284 - Non -Discharge Application Rate
0.33
52.0
inches
S-14
TNGC Charlotte LLC
4625-84-8012
Iredell
35.533073'
-80.920579'
1.06
Cecil
01284 - Non -Discharge Application Rate
0.33
52.0
inches
S-15
TNGC Charlotte LLC
4625-84-8012
Iredell
35.531756'
-80.921223'
0.91
Cecil
01284 - Non -Discharge Application Rate
0.33
52.0
inches
S-16
TNGC Charlotte LLC
4625-84-8012
Iredell
35.532352'
-80.920654'
0.71
Cecil
01284 - Non -Discharge Application Rate
0.33
52.0
inches
S-17
TNGC Charlotte LLC
4625-84-8012
Iredell
35.533143'
-80.920886'
1.04
Cecil
01284 - Non -Discharge Application Rate
0.33
52.0
inches
Total:
15.49
WQ0015931 Version 5.0 Attachment B Page 1 of 1
FIGURE 1 — SITE MAP
TNGC Charlotte LLC
Permit Number: WQ0015931 Version: 5.0
ISO
zs
TREE RD.
OLE
LO
ry
9
m ;:
T
5f?........_ �
VICINITY MAP N.T.S.
OUXE POWER GOMPANY
08 338 PG 328
08 318 PG 74
08 338 PG 326
fI�
0
GOMDAW
LO75 1. 3_8
M9 7 PG 29
EX. WELL SM '
CRESCENT RE591FRCE5, WC.
TAX MAP NO. 2F-A..-7
481--U
LAKE NORMAN
IHE f i/' FSOR
LAKE NORMAN
LAKE NORMAN
LOSS 27,2B.29
MCI 21 PG 4D
LDTS 20.21.22
u8 25 PG 113
SEC 6 -- LOT $69D
M$ 18 PG 55
CHANGE ORDER 4: REWSED DRIP F7ELDSIMME MAIN BDS
5
11112198
CHANGE ORDER 3 REVISED SEWER LINE 2
BDS
4
11110198
REVISED BLOOER BLAG
BDS
3
2
11109198
10 19/98
ADDED WA7ER METER AND SFP ASSEMBLY
CHANGE ORDER 2.• REVISED SAN. SEWER
BDS
BDS
1
10115198
CHANGE ORDER 1: REVISED SAM, SEWER
BDS
NO.
DATE
REVISION
BY
� 5liEEi isrl.f PRP3fCr 110. 8802pp pp ..••11
9
COMPOSITE SITE PLAN SCA1k: 1 „ 500,I
Da 1;±
SEPT. 1998
Prlo3ecr UitA1?F j3Y
THE VILLAGE BD5
'ls ss1 Fi11 rf777' 011eCKM 9r
, a� AT THE POINT ,tAME DCSI
CRESCENT RESOURCES 1REDEEE CO. COMPOSITE
_ OiiAK1NG Nii
SEAL
6988 - -T• l
Desian
'�� �[`•` ENGINEERING SERVICES INC.
7�ttt+ftiltsssss��s z � 1700 EAST BOULEVARD CHARLOTTE. NC 28203 2-OF �SH"rS
jjj PHONE(704) 376- 7777 FAx(704) 376 -8235
corn posi Le.dwg 111,598 J1 J38
y
FIGURE 4 -PROPOSED FACILITY SITE MAP (TRUMP NATIONAL GOLF CLUB CHARLOTTE WWTP)
SURVEY INFORMATION PROVIDED BY:
LDSI, Inc.
201 WEST 29TH STREET
CHARLOTTE, NC 28206
704-337-8329
CONTRACTOR TO INSTALL NEW FIBERGLASS BASIN
WITH NEW SIMPLEX GRINDER PUMP PACKAGE
TO HANDLE WASTE FLOW FROM EX. OFFICE
RESTROO M .
PROPOSED CONTROL PANEL UNIT FOR
PUMPS, UV, TUBIDIMETER & TELEMETRY.
ENCLOSURE TO BE NEMA 4X
PROPOSED NEW FENCE AROUND
TREATMENT AREA AND PONDS.
REPLACE WITH LIKE KIND.
I NGC Charlotte LLU
BB 2168-1361
PB 32-13
Line Legend:
Svmbol Description
FM
ONKPI
— I,rI+M
UC0111
WAN
UNKII
R/w
FM
Fence Line
Water Line
Esc Force Main Sewer
Gravity Sewer
Underground Electric
Underground Communication
Unknown Utility
Compressed Air
Right -of -Way
Prop. Forcemain Sewer
PROPOSED TURBIDITY CHAMBER
SEE DETAIL ON SHEET U-7
Pry ve 12 �Ft 1Ni.:AII :.
p:., ---- - ---- -- ---
- Meat ier A ct s `Drive-
_ . Textile Filter #2 (Future) r
} •.: _ - - - - - - - ,, Stage II Polishing Filter
I _ _
40,
Textile Filter # 1
1 _Tca
j
- - --� - - - - - Generator
hi -u� u� Ilr � LC --�• 1E� �JE - - LE � 11E� � LIE
]C jF Lf `r 'JE r fE -&�'F �, -. Ill.l l�•1 lli llfl - II�rOr-1 -
Existing Transformer Pad I PROPOSED TEXTILE FILTER
NO SEE SHEET U-6 FOR DETAILS
f
9 N
Existing Office Electrical Panels
& Blvwel r Building _ � g` FILTER MAINTENANCE BYPASS
w� ��t+r'GotLined Upset Pond
EXISTING WWTF TO BE ABANDONED ONCE CONTRACTOR TO INSTALL SEDIMENT FENCING
' - NEW FACILITY IS PERMITTED, INSTALLED AROUND EXISTING UPSET POND AND WET WEATHER
+' AND CERTIFIED TO BE PLACED IN OPERATIION. y o
I STORAGE POND DURING CONSTRUCTION TO PROTECT I
SEE SHEET DEMO-1 FOR DETAILS. '
+I
1
U
n
�
II
I
I
I
r
I
I
I
I
I
I
UNITS FROM STORMWATER RUNOFF/SEDIMENTATION.
F
a _�' PROPOSED SEPTIC/FLOW EQUALIZATION
I �. TANK. SEE SHEET U-4 FOR DETAILS.
I• + �
.41
I
i� rMto
I
In IPL
±22 LF OF 4-INCH RESTRAINED JOINT
PVC PIPE.
I 1 I I
N
Fk 6 - -
7P _
I ! UL - UE +,�E — UE 4 IIE UE L14
0
ll
CUT IN NEW 4-IN. TEE WITH NEW
4- IN■ G.V. S & W OFF NEW TEE
T
TIE IN PLANT DISCHARGE INTO EX. 6-IN
DIP PIPE OUTSIDE LIMITS OF EX. POND LINER.
lE HF
VICINITY MAP
No SCALE
WIN
PROPOSED (2) UV UNITS IN
SERIES & SAMPLE PORT, SEE SHEET
U-6 FOR DETAILS
PROPOSED POLISHING FILTER
SEE SHEET U-6 FOR DETAILS
Existing Wet Weather
Lined Storage Pond
I r1 I [I- I' I-, - �
RZ
8�1
Know what's below.
Call before you dig.
GRAPHIC SCALE
0 5 10 20
1 inch = 10 feet
z
O
...moo❑
o
-.�
U� XJ
�
•v�iwH
.
A <
map
pit
a
0
V) v
a
� N
00
�N
02
CW 00
C
C6
COJz�
o
0 C/2 0
N�
a
o
Q L
Ld
af
v
co
o �U
�.C-)
ssl�
4-4 r� ;_4
P,
M c�
f'1
o E� .�
W
a
Ei v
REVISIONS
BY
REV. PER COMM24TS BY
DEQ - HDPU L PLUMMER
DMD
(12/20/22)
REV. PER COMMENTS BY
DEQ - HDPU L PLMMER
€]MD
(3/31/23)
REV. PER COMMENTS BY
DEQ - NOPU Z MEGA
DMD
Date- 6/16/22
Scale: 1=10 Ft
1 n Contours
—
Drown: DMA]
Checked: DEM
Project- 2019-03-17-EC
.lob: 2019-03-17-EC
Sheet
U
6/1/23
ZN
7 Sheets