HomeMy WebLinkAbout20210053 Ver 1_Riparian Buffer Authorization Request_20230815Original Submittal 8/15/2023
A. Owner/Applicant Information
General Information Q
..........................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................
Primary Contact Email: * sclark@sageecological.com
Please list the contact person's email for questions or payment on this project if needed.
Who is submitting the application?* ❑ Owner
❑ Applicant other than Owner
p Agent
1. Property Owner Information:
1a. Name on Recorded Deed:*
Heritage RMX LLC
1b. Responsible Party:
Robert Defeo
(for Corporations)
1c. Mailing Address:*
Street Address
1017 Exeter Field Circle
Address Line 2
City
State / Province / Region
Raleigh
NC
Postal / Zip Code
Country
27614
USA
1d. Telephone:* 631-404-5839
le. Email Address:*
raddevelopment@yahoo.com
3. Agent Information:
3a. Name:
3b. Company Affiliation:
3c. Mailing Address: Street Address
Address Line 2
City State / Province / Region
Postal / Zip Code Country
3d. Telephone: 3e. Email Address:
3f. Attach a signed and dated copy of the agent Click the upload button or drag and drop files here to attach document
authorization form. PDF only
B. Project Information and Prior Project History
1. Project Information
...........................................................
1 a. Name of Project:* Foundation Drive Apartments
(Subdivision, facility, or establishment name)
1b. Is this a publicly -funded transportation project?*
1d. Subdivision Name:
1e. Nearest Municipality: Wake Forest
1f. Property Size: 5.15
acres
1g. County (or Counties) where the project is located: *
1h. Property ID# Date of Purchase
1749593299
Tax PIN or Parcel id
1 i. Deed Information
Type of Book � � Book# Page#
Deed 18056 651
[Map 12015 1907
1j. Attach a copy of the recorded map that indicates when the lot was last platted.
Click the upload button or drag and drop files here to attach document
Foundation Drive Plat Map.pdf 138.94KB
PDF only
1 k. How would you like to provide the Latitude and Longitude information?
Address Lookup
Manually
Latitude* Longitude*
11. Is the project located in any of North Carolina's twenty coastal counties?* Yes
No
2. Surface Waters
2a. Name of the nearest body of water to proposed project: * Smith Creek
2b. Water Quality Classification of nearest receiving water: C;NSW
2c. List the total estimated linear feet of all existing streams (intermittent and perennial) on the property:
738
(linear feet only)
3. Project Description:
3a. Describe the existing conditions on the site and the general land use in the vicinity of the project at the time of this application:
The majority of the Site is currently undeveloped and wooded. The northern and western portions of the Site contain mature pines
with a relatively open understory. Hardwoods are dominant in the drainage along the eastern boundary. Adjacent parcels to the south
and east have been cleared, and a small portion of the Site was also cleared for access to the other parcels. General land use in the
area includes commercial and residential development.
3b. Attach an 8'/z x 11 excerpt from the most recent version of the USGS topographic map indicating the location of the site.
Click the upload button or drag and drop files here to attach document
07-Figurel - USGS.pdf 6.8MB
PDF only
3c. Attach an 8'/z x 11 excerpt from the most recent version of the published County NRCS Soil Survey Map depicting the project site.
Click the upload button or drag and drop files here to attach document
07-Figure2-NRCS Soils Map.pdf 7.62MB
PDF only
4. Proposed Activity
Provide a detailed description of the proposed activity including its purpose and include the type of equipment to be used:
The purpose of the Project is to construct an apartment development to meet the demand for housing in this part of the county.
Access to the Site will be provided by a connection to Foundation Drive to the southwest. Apartment buildings and associated
attendant features such as parking, sidewalks, and stormwater control measures will be constructed. Impacts to Zone 2 of the riparian
buffer will result from grading for the stormwater pond, grading for the parking area, and installation of an aerial sewerline. Zone 1
impacts will result from the installation of the aerial sewerline.
Sewer and water will tie into existing lines adjacent to the Site. The sewerline connection will cross Smith Creek to the north. The
construction corridor and the maintenance easement will be 40-feet in width.
The Project proposes to tie into existing utilities adjacent to the Site. Typical equipment used in construction and utility projects (i.e.,
backhoes, excavators, dump trucks) will be utilized.
Attach a site plan as applicable to the project:
Click the upload button or drag and drop files here to attach document
C1.0 STREAM BUFFER IMPACT MAP.pdf 2.62MB
PDF only
5. Jurisdictional Determinations
...... ...... ... ...... ...... ..... ..... ...... .... .......
5a. Have jurisdictional wetlands or stream determinations by the Corps or State been requested or obtained for this property/project
(including all prior phases) in the past?*
Yes
No
5b. Who did the determination on the jurisdictional areas?
Who did the determination?IF
List name if known
Date IF
Attach
Agent/Consultant
Sean Clark, Sage Ecological
12/02/2020
Services
pdf only
(Name if known)
Corps
April R. Norton, USACE
05/18/2021
(Name if known)
Preliminary Jurisdictional
832.9KB
Determination for
Foundation Drive in Wake
County (SAW-2021-00426)
(001).pdf
pdf only
*** Please include the date of the determination and upload a copy of the determination.
Comments:
A Neuse River Riparian Buffer Determination was not requested as the presence of riparian buffers on the Site are not contested.
6. Project History
6a. Have permits or certifications been requested or obtained for this project (including all prior phases) in the past?
Yes
No
7. Future Project Plans
7a. Is this project a phased project?*
C. Proposed Impacts Inventory
Buffer Impacts
Project is in which protected Basin?*
Neuse River Basin (15A NCAC 02B.0233)
Catawba River Basin (15A NCAC 02B.0243)
Randleman Lake Watershed (15A NCAC 026.0250)
Tar -Pamlico River Basin (15A NCAC 02B.0259)
Jordan Lake Watershed (15A NCAC 02B.0267)
O Goose Creek Watershed (15A NCAC 0213.0606 & 15A NCAC 02B.0607)
Individually list all buffer impacts below. If any impacts require mitigation, then you MUST fill out Section D of this form.
Site# - Reason Stream Name Buffer Impact* Impact Type Zone 1 Zone 2
Impact 1 - Grading, SCM
SA
Permanent (P)
Allowable
0.00
3,471.00
Map label (e.g. Road Crossing 1)
Perm or Temp
Square Feet
Square Feet
Impact 2 - Grading, Parking
SA
Permanent (P)
Allowable
0.00
1,520.00
Map label (e.g. Road Crossing 1)
Perm or Temp
Square Feet
Square Feet
Impact 3 - Sewerline
Smith Creek (offsite)
Permanent (P)
Allowable
1,590.00
755.00
Construction
Perm or Temp
Square Feet
Square Feet
Map label (e.g. Road Crossing 1)
Total Zone 1 Impacts: 1,590.00
Total Zone 2 Impacts: 5,746.00
Total Buffer Impacts: 7,336.00
Comments:
Proposed Zone 1 impacts total 1,590 SF for installation of a sewerline to connect to existing adjacent sewer lines. Zone 2 impacts
total 755 SF for sewerline installation. Zone 2 impacts will result from grading for the SCM pond (3,471 SF) and from grading for a
parking lot (1,520 SF).
D. Impact Justification and Mitigation
1. Avoidance and Minimization
n
....................
1a. Specifically describe measures taken to avoid or minimize the proposed impacts in designing the project.
A stream and wetland delineation was performed to identify environmentally sensitive areas on the Site. No impacts to jurisdictional
Waters of the US are proposed. Steeper slopes are proposed adjacent to the outer zones of the riparian buffer to minimize grading
impacts in Zone 2. Construction fencing will be used to define the construction corridor and prevent any accidental additional impacts.
Silt fencing and appropriate sediment and erosion control devices will be installed to provide additional protection from stormwater
runoff.
1 b. Specifically describe measures taken to avoid or minimize the proposed impacts through construction techniques.
General techniques include the use of construction fencing to define the construction corridor and prevent any accidental additional
impacts. Equipment will be parked and cleaned in uplands away from jurisdictional areas. Work within jurisdictional areas will be
conducted during periods when dry weather is predicted, and large bare areas of soil will be reseeded and protected as soon as
practicable. Silt fencing and sediment basins will also be used to prevent sediment runoff into the stream and wetland areas.
E. Diffuse Flow Plan
1a. What type of SCM are you providing?*
Level Spreader
Vegetated Conveyance (lower SHWT)
Wetland Swale (higher SHWT)
Proposed project will not create concentrated stormwater flow through the buffer
Other SCM that removed minimum of 30% nitrogen
1 b. Describe how diffuse flow will be maintained: *
One stormwater wet pond is proposed in the northeastern corner of the Site. The stormwater management plan will be approved by
the local delegated authority.
1 c. Diffuse Flow Documentation Click the upload button or drag and drop files here to attach document
C1.0 STREAM BUFFER IMPACT MAP.pdf 2.62MB
PDF only
F. Supplementary Information
Environmental Documentation
1a. Does the project involve an expenditure of public (federal/state/local) funds or the use of public (federal/state) land?
Yes
No
Violations
2a. Is the site in violation of DWR Wetland Rules (15A NCAC 02H .0500), Isolated Wetland Rules (15A NCAC 02H .1300), DWR Surface
Water or Wetland Standards, or Riparian Buffer Rules (15A NCAC 02B .0200)?
2b. Is this an after -the -fact buffer authorization application?
Yes
No
G. Additional Information
Please upload any additional information you would like the Division to consider during application review.
Additional Attachments: Click the upload button or drag and drop files here to attach document
Foundation Drive Apartments Riparian Buffer
Application - Wake County - Neuse RB - Sage 3.85MB
#2020.100. pdf
PDF only
Additional Comments:
Attachments:
Agent Authorization Form
Tax Map Information
Figure 1 — USGS Site Vicinity Map
Figure 2 — Soil Survey Site Vicinity Map
Figure 3 — PJD Sketch Map
Impact Maps
H. Sign and Submit
By digitally signing below, I certify that:
o I have given true, accurate, and complete information on this form;
o I agree that submission of this form is a "transaction" subject to Chapter 66, Article 40 of the NC General Statutes (the "Uniform Electronic Transactions
Act)
o I agree to conduct this transaction by electronic means pursuant to Chapter 66, Article 40 of the NC General Statutes (the "Uniform Electronic
Transactions Act');
• I understand that an electronic signature has the same legal effect and can be enforced in the same way as a written signature; AND
o I intend to electronically sign and submit the application form."
Print Name:' Kimberly Hamlin
Signature
Submission Date: (Auto populated field)
Initial Review
Is this accepted into the review process?*
Is this project a public transportation project?*
ID#*
Version:
Select Reviewer:
Select Reviewing Office*
Has payment been received?*
Yes No
Yes
No
20210053
1
Chem Smith: Cherri.Smith
Raleigh Regional Office - (919) 791-4200
No Payment Needed
Fee Received
Need Fee - send electronic notification