HomeMy WebLinkAboutNC0050342_Compliance Evaluation Inspection_20230817 (2)United States Environmental Protection Agency
Form Approved.
EPA Washington, D.C. 20460
OMB No. 2040-0057
Water Compliance Inspection Report
Approval expires 8-31-98
Section A: National Data System Coding (i.e., PCS)
Transaction Code NPDES yr/mo/day Inspection Type Inspector Fac Type
1 IN 2 u 3 I NC0050342 111 121 23/07/28 I17 18 L� ] 19 I s I 201
211IIIII 111111III II III III1 I I IIIII IIIIIIIII II r6
Inspection
Work Days Facility Self -Monitoring Evaluation Rating B1 QA ---------------------- Reserved -------------------
67
I 72 I ni I 73 � I 74 79 I I I I I I I80
70 I I 71 I LL -1 I I
LJ
Section B: Facility Data
Name and Location of Facility Inspected (For Industrial Users discharging to POTW, also include
Entry Time/Date
Permit Effective Date
POTW name and NPDES Dermit Number)
10:OOAM 23/07/28
17/09/01
Muddy Creek WWTP
4561 Cooper Rd
Exit Time/Date
Permit Expiration Date
Winston Salem NC 27102
12:30PM 23/07/28
22/06/30
Name(s) of Onsite Representative(s)/Titles(s)/Phone and Fax Number(s)
Other Facility Data
Ozie Keith Jones/ORC/336-397-7679/
Name, Address of Responsible Official/Title/Phone and Fax Number
Contacted
Ozie K Jones,4561 Cooper Rd Winston Salem NC 27127//336-397-7679/3363977667
No
Section C: Areas Evaluated During Inspection (Check only those areas evaluated)
Permit 0 Operations & Maintenar 0 Records/Reports Facility Site Review
Effluent/Receiving Wate
Section D: Summary of Finding/Comments (Attach additional sheets of narrative and checklists as necessary)
(See attachment summary)
Name(s) and Signature(s) of Inspector(s) Agency/Office/Phone and Fax Numbers Date
Gary Hudson DWR/Division of Water Qua Iity/336-776-9694/
ocuSigned by:
FiRas", 8/16/2023
Signa gN ment Q A Reviewer Agency/Office/Phone and Fax Numbers Date
by:
uj,'AA
ocu ig
T. '!5'at- 8/16/2023
EPA Form 3560-3 (Rev 9-94) Previous editions are obsolete.
Page#
NPDES yr/mo/day Inspection Type
NCO050342 I11 12I 23/07/28 117 18 i c i
(Cont.)
Section D: Summary of Finding/Comments (Attach additional sheets of narrative and checklists as necessary)
August 9, 2023 — Inspection Summary — NC0050342
On July 28, 2023, Division of Water Resources staff Gary Hudson conducted a routine compliance
inspection at the Muddy Creek WWTP. Bonnie McKee, Paul Morrison, and Keith Jones were present
during the inspection. A review of the October 2022, and April 2023 eDMR was compared to
laboratory bench sheets. No discrepancies were noted. During the inspection, no violations or items
of concern were noted. The following treatment components were inspected:
Permit:
The current permit became effective on September 1, 2017, and expired June 30, 2022. A new draft
permit has been issued and is pending modifications.
Odor Control:
There are 3 charcoal air scrubbers located at the preliminary treatment building.
Preliminary Treatment:
The Muddy Creek WWTP has 3 mechanical bar screens rated at 50 MGD each, and 2 cyclone grit
chambers.
Primary Treatment:
Primary treatment consists of 4 rectangular primary clarifiers. One of the clarifiers was out of service
during the inspection.
Secondary Treatment:
Secondary treatment consists of 3 activated sludge basins with fine bubble diffusers, 5 blowers, and
5 secondary clarifiers. Sodium hydroxide and lime can be added for pH adjustment if needed.
Final Effluent:
The final effluent is treated with sodium hypochlorite and sodium bisulfite prior the being pumped to
the Yadkin River via the offsite effluent pump station located at Frybridge'
Sludge Digestion:
The Muddy Creek WWTP has 4 floating cover anaerobic digesters.
Sludge Handling and disposal:
All digested sludge goes to the Archie Elledge WWTP to be dried and pelletized.
Page#
Permit: NCO050342 Owner -Facility: Muddy Creek WWTP
Inspection Date: 07/28/2023 Inspection Type: Compliance Evaluation
Permit
Yes
No
NA
NE
(If the present permit expires in 6 months or less). Has the permittee submitted a new
0
❑
❑
❑
application?
Is the facility as described in the permit?
0
❑
❑
❑
# Are there any special conditions for the permit?
❑
0
❑
❑
Is access to the plant site restricted to the general public?
0
❑
❑
❑
Is the inspector granted access to all areas for inspection?
0
❑
❑
❑
Comment: The current permit became effective on September 1, 2017, and expired June 30,
2022. A new draft permit has been issued and is pending modifications.
Record Keeping
Are records kept and maintained as required by the permit?
Is all required information readily available, complete and current?
Are all records maintained for 3 years (lab. reg. required 5 years)?
Are analytical results consistent with data reported on DMRs?
Is the chain -of -custody complete?
Dates, times and location of sampling
Name of individual performing the sampling
Results of analysis and calibration
Dates of analysis
Name of person performing analyses
Transported COCs
Are DMRs complete: do they include all permit parameters?
Has the facility submitted its annual compliance report to users and DWQ?
(If the facility is = or > 5 MGD permitted flow) Do they operate 24/7 with a certified
operator on each shift?
Is the ORC visitation log available and current?
Is the ORC certified at grade equal to or higher than the facility classification?
Is the backup operator certified at one grade less or greater than the facility
classification?
Is a copy of the current NPDES permit available on site?
Facility has copy of previous year's Annual Report on file for review?
Yes No NA NE
• ❑ ❑ ❑
• ❑ ❑ ❑
■ ❑ ❑ ❑
• ❑ ❑ ❑
• ❑ ❑ ❑
■ ❑ ❑ ❑
• ❑ ❑ ❑
• ❑ ❑ ❑
■ ❑ ❑ ❑
■ ❑ ❑ ❑
■ ❑ ❑ ❑
■ ❑ ❑ ❑
■ ❑ ❑ ❑
Comment: Ms. McKee, Mr. Morrison, Mr. Jones and the rest of the staff do a very qood lob with
keeping
records.
A review of the October 2022, and April 2023 eDMR was compared to laboratory bench
sheets. No discrepancies were noted.
Page# 3
Permit: NCO050342
Inspection Date: 07/28/2023
Record Keeping
Owner -Facility: Muddy Creek WWTP
Inspection Type: Compliance Evaluation
Yes No NA NE
Operations & Maintenance Yes No NA NE
Is the plant generally clean with acceptable housekeeping? 0 ❑ ❑ ❑
Does the facility analyze process control parameters, for ex: MLSS, MCRT, Settleable ❑ ❑ ❑
Solids, pH, DO, Sludge Judge, and other that are applicable?
Comment: The WWTP appeared to be well operated and maintained. No discrepancies were
noted during the inspection.
Bar Screens
Type of bar screen
a.Manual
b.Mechanical
Are the bars adequately screening debris?
Is the screen free of excessive debris?
Is disposal of screening in compliance?
Is the unit in good condition?
Yes No NA NE
• ❑ ❑ ❑
• ❑ ❑ ❑
• ❑ ❑ ❑
• ❑ ❑ ❑
Comment: The Muddy Creek WWTP has 3 mechanical bar screens rated at 50 MGD each, and 2
cyclone grit chambers.
Grit Removal
Type of grit removal
Yes No NA NE
a.Manual
❑
b.Mechanical
Is the grit free of excessive organic matter?
0
❑
❑
❑
Is the grit free of excessive odor?
■
❑
❑
❑
# Is disposal of grit in compliance?
0
❑
❑
❑
Comment: There are 3 charcoal air scrubbers located at the
preliminary treatment building.
Primary Clarifier
Yes
No
NA
NE
Is the clarifier free of black and odorous wastewater?
0
❑
❑
❑
Is the site free of excessive buildup of solids in center well of circular clarifier?
0
❑
❑
❑
Are weirs level?
0
❑
❑
❑
Is the site free of weir blockage?
■
❑
❑
❑
Is the site free of evidence of short-circuiting?
0
❑
❑
❑
Page# 4
Permit: NCO050342
Inspection Date: 07/28/2023
Owner -Facility: Muddy Creek WWTP
Inspection Type: Compliance Evaluation
Primary Clarifier
Yes
No
NA
NE
Is scum removal adequate?
0
❑
❑
❑
Is the site free of excessive floating sludge?
0
❑
❑
❑
Is the drive unit operational?
0
❑
❑
❑
Is the sludge blanket level acceptable?
❑
❑
❑
Is the sludge blanket level acceptable? (Approximately'/4
of the sidewall depth) ❑
❑
❑
Comment: Primary treatment consists of 4 rectangular primary clarifiers. One of the clarifiers was
out of service during the inspection.
Aeration Basins
Mode of operation
Type of aeration system
Is the basin free of dead spots?
Are surface aerators and mixers operational?
Are the diffusers operational?
Is the foam the proper color for the treatment process?
Does the foam cover less than 25% of the basin's surface?
Is the DO level acceptable?
Is the DO level acceptable?(1.0 to 3.0 mg/1)
Yes No NA NE
■ ❑ ❑ ❑
❑ ❑ ■ ❑
■ ❑ ❑ ❑
■ ❑ ❑ ❑
■ ❑ ❑ ❑
❑ ❑ ❑ ■
❑ ❑ ❑ ■
Comment: Secondary treatment consists of 3 activated sludge basins with fine bubble diffusers,
5
blowers, and 5 secondary clarifiers. Sodium hydroxide and lime can be added for
PH
adjustment if needed.
Secondary Clarifier
Yes
No
NA
NE
Is the clarifier free of black and odorous wastewater?
■
❑
❑
❑
Is the site free of excessive buildup of solids in center well of circular clarifier?
■
❑
❑
❑
Are weirs level?
0
❑
❑
❑
Is the site free of weir blockage?
0
❑
❑
❑
Is the site free of evidence of short-circuiting?
■
❑
❑
❑
Is scum removal adequate?
■
❑
❑
❑
Is the site free of excessive floating sludge?
0
❑
❑
❑
Is the drive unit operational?
0
❑
❑
❑
Is the return rate acceptable (low turbulence)?
0
❑
❑
❑
Is the overflow clear of excessive solids/pin floc?
■
❑
❑
❑
Is the sludge blanket level acceptable? (Approximately'/4 of the sidewall depth)
❑
❑
❑
Page# 5
Permit: NC0050342
Inspection Date: 07/28/2023
Secondary Clarifier
Owner -Facility: Muddy Creek WWTP
Inspection Type: Compliance Evaluation
Yes No NA NE
Comment: The final effluent is treated with sodium hypochlorite and sodium bisulfite prior the
being pumped to the Yadkin River via the offsite effluent pump station located at
Frybridge'
Page#